summaryrefslogtreecommitdiffstats
path: root/docs/labs
diff options
context:
space:
mode:
authorJack Morgan <jack.morgan@intel.com>2016-08-24 12:39:48 +0000
committerGerrit Code Review <gerrit@172.30.200.206>2016-08-24 12:39:48 +0000
commit9d7fafb4b3b80fbf0028ea03e66773cce65bcea0 (patch)
tree70a7387f89345e8e023d8b77b116dc7d4f3da266 /docs/labs
parent8b19eb63a99014cc1c59d05efe2e1fbe5f98a379 (diff)
parent03d8ab9673dee6e8bbedf073ea790cfc0af14344 (diff)
Merge "Due to migration, update zte-pod1 and zte-pod2 info."
Diffstat (limited to 'docs/labs')
-rw-r--r--docs/labs/zte-sh-lab/pod1_description.rst135
-rw-r--r--docs/labs/zte-sh-lab/pod1_inventory.yaml23
-rw-r--r--docs/labs/zte-sh-lab/pod2_description.rst126
-rw-r--r--docs/labs/zte-sh-lab/pod2_inventory.yaml23
4 files changed, 176 insertions, 131 deletions
diff --git a/docs/labs/zte-sh-lab/pod1_description.rst b/docs/labs/zte-sh-lab/pod1_description.rst
index 27666308..7ec53a82 100644
--- a/docs/labs/zte-sh-lab/pod1_description.rst
+++ b/docs/labs/zte-sh-lab/pod1_description.rst
@@ -48,64 +48,89 @@ POD1 share the same **Jump Host** in the lab.
**Nodes/Servers**
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node1 | ZTE | E9000 | 281498500141 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.101 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 4c:09:b4:b2:59:84 | 4c:09:b4:b2:59:87 | 4c:09:b4:b1:de:38 | |
-| | | | | | | | zteroot/superuser | vlan 1/PXE | vlan 1/ public | |
-| | | | | | | | | vlan 101/management | vlan 103/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 4c:09:b4:b1:de:3a | |
-| | | | | | | | | | vlan 102/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node2 | ZTE | E9000 | 281498500179 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.22 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 4c:09:b4:b2:59:f9 | 4c:09:b4:b2:59:fc | 4c:09:b4:b1:de:40 | |
-| | | | | | | | zteroot/superuser | vlan 1/PXE | vlan 1/ public | |
-| | | | | | | | | vlan 101/management | vlan 103/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 4c:09:b4:b1:de:42 | |
-| | | | | | | | | | vlan 102/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node3 | ZTE | E9000 | 281498500008 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.3 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 4c:09:b4:b2:59:9f | 4c:09:b4:b2:59:a2 | 4c:09:b4:b1:de:1c | |
-| | | | | | | | zteroot/superuser | vlan 1/PXE | vlan 1/ public | |
-| | | | | | | | | vlan 101/management | vlan 103/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 4c:09:b4:b1:de:1e | |
-| | | | | | | | | | vlan 102/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node4 | ZTE | E9000 | 281498500157 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.4 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 4c:09:b4:b2:59:d5 | 4c:09:b4:b2:59:d8 | 4c:09:b4:b1:de:18 | |
-| | | | | | | | zteroot/superuser | vlan 1/PXE | vlan 1/ public | |
-| | | | | | | | | vlan 101/management | vlan 103/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 4c:09:b4:b1:de:1a | |
-| | | | | | | | | | vlan 102/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node5 | ZTE | E9000 | 281498500119 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.5 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 4c:09:b4:b2:59:72 | 4c:09:b4:b2:59:75 | 4c:09:b4:b1:de:48 | |
-| | | | | | | | zteroot/superuser | vlan 1/PXE | vlan 1/ public | |
-| | | | | | | | | vlan 101/management | vlan 103/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 4c:09:b4:b1:de:4a | |
-| | | | | | | | | | vlan 102/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node1 | ZTE | E9000 | 701763100025 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.101 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cf:d9 | 74:4a:a4:00:cf:dc | 74:4a:a4:00:b0:e1 | |
+| | | | | | | | zteroot/superuser | native vlan 160/PXE | vlan 161/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:e2 | |
+| | | | | | | | | | vlan 162/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:b0:dd | |
+| | | | | | | | | | vlan 1120/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:de | |
+| | | | | | | | | | vlan 163/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node2 | ZTE | E9000 | 701763100224 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.102 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ce:cb | 74:4a:a4:00:ce:ce | 74:4a:a4:00:d6:ad | |
+| | | | | | | | zteroot/superuser | native vlan 160/PXE | vlan 161/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:ae | |
+| | | | | | | | | | vlan 162/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a9 | |
+| | | | | | | | | | vlan 1120/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:aa | |
+| | | | | | | | | | vlan 163/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node3 | ZTE | E9000 | 701763100064 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.103 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cf:55 | 74:4a:a4:00:cf:58 | 74:4a:a4:00:d6:ab | |
+| | | | | | | | zteroot/superuser | native vlan 160/PXE | vlan 161/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:ac | |
+| | | | | | | | | | vlan 162/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:af | |
+| | | | | | | | | | vlan 1120/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:b0 | |
+| | | | | | | | | | vlan 163/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node4 | ZTE | E9000 | 289842100103 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.104 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:49:81 | 74:4a:a4:00:49:84 | 74:4a:a4:00:b1:a5 | |
+| | | | | | | | zteroot/superuser | native vlan 160/PXE | vlan 161/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:b1:a6 | |
+| | | | | | | | | | vlan 162/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:b1:b1 | |
+| | | | | | | | | | vlan 1120/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:b1:b2 | |
+| | | | | | | | | | vlan 163/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node5 | ZTE | E9000 | 701763100220 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.105 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ce:bf | 74:4a:a4:00:ce:c2 | 74:4a:a4:00:d6:8d | |
+| | | | | | | | zteroot/superuser | native vlan 160/PXE | vlan 161/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:8e | |
+| | | | | | | | | | vlan 162/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9b | |
+| | | | | | | | | | vlan 1120/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9c | |
+| | | | | | | | | | vlan 163/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
**Subnet allocations**
-+----------------+--------------+----------------+------------+---------------+
-| Network name | Address | Mask | Gateway | VLAN id |
-+----------------+--------------+----------------+------------+---------------+
-| Public | 172.10.0.0 | 255.255.255.0 | 172.10.0.1 | untagged |
-+----------------+--------------+----------------+------------+---------------+
-| Fuel Admin/PXE | 10.20.0.0 | 255.255.255.0 | 10.20.0.2 | native vlan 1 |
-+----------------+--------------+----------------+------------+---------------+
-| Fuel Mangement | 192.168.10.0 | 255.255.255.0 | | 101 |
-+----------------+--------------+----------------+------------+---------------+
-| Fuel Storage | 192.168.11.0 | 255.255.255.0 | | 102 |
-+----------------+--------------+----------------+------------+---------------+
++----------------+--------------+----------------+------------+-----------------+
+| Network name | Address | Mask | Gateway | VLAN id |
++----------------+--------------+----------------+------------+-----------------+
+| Public | 172.60.0.0 | 255.255.255.0 | 172.60.0.1 | 163 |
++----------------+--------------+----------------+------------+-----------------+
+| Fuel Admin/PXE | 10.20.6.0 | 255.255.255.0 | 10.20.6.2 | native vlan 160 |
++----------------+--------------+----------------+------------+-----------------+
+| Fuel Mangement | 192.168.61.0 | 255.255.255.0 | | 161 |
++----------------+--------------+----------------+------------+-----------------+
+| Fuel Storage | 192.168.62.0 | 255.255.255.0 | | 162 |
++----------------+--------------+----------------+------------+-----------------+
VPN Users
diff --git a/docs/labs/zte-sh-lab/pod1_inventory.yaml b/docs/labs/zte-sh-lab/pod1_inventory.yaml
index 5ceb0dbd..3414bc12 100644
--- a/docs/labs/zte-sh-lab/pod1_inventory.yaml
+++ b/docs/labs/zte-sh-lab/pod1_inventory.yaml
@@ -2,48 +2,45 @@ nodes:
- name: node1
tags: control #optional param, other valid value "compute"
arch: "x86_64"
- mac_address: "4c:09:b4:b2:59:87" #pxe boot interface mac
+ mac_address: "74:4A:A4:00:CF:DC" #pxe boot interface mac
power:
type: ipmi
- address: 129.5.1.101
+ address: 192.168.1.101
user: zteroot
pass: superuser
- name: node2
tags: control
arch: "x86_64"
- mac_address: "4c:09:b4:b2:59:fc"
+ mac_address: "74:4A:A4:00:CE:CE"
power:
type: ipmi
- address: 129.5.1.22
+ address: 192.168.1.102
user: zteroot
pass: superuser
- name: node3
tags: control
arch: "x86_64"
- mac_address: "4c:09:b4:b2:59:a2"
+ mac_address: "74:4A:A4:00:CF:58"
power:
type: ipmi
- address: 129.5.1.3
+ address: 192.168.1.103
user: zteroot
pass: superuser
-
- name: node4
tags: compute
arch: "x86_64"
- mac_address: "4c:09:b4:b2:59:d8"
+ mac_address: "74:4A:A4:00:49:84"
power:
type: ipmi
- address: 129.5.1.4
+ address: 192.168.1.104
user: zteroot
pass: superuser
-
- name: node5
tags: compute
arch: "x86_64"
- mac_address: "4c:09:b4:b2:59:75"
+ mac_address: "74:4A:A4:00:CE:C2"
power:
type: ipmi
- address: 129.5.1.5
+ address: 192.168.1.105
user: zteroot
pass: superuser
-
diff --git a/docs/labs/zte-sh-lab/pod2_description.rst b/docs/labs/zte-sh-lab/pod2_description.rst
index 1931ba56..961aa2a0 100644
--- a/docs/labs/zte-sh-lab/pod2_description.rst
+++ b/docs/labs/zte-sh-lab/pod2_description.rst
@@ -47,65 +47,91 @@ POD2 share the same **Deploy Server** with POD1.
+-----------+--------+-------+---------------+-----------+--------+-----------+--------------------+------------------+-------+
-**Compute Nodes**
-
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node1 | ZTE | E9000 | 281498500141 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.9 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:ea | 3c:da:2a:e8:01:ed | 3c:da:2a:e9:02:dc | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:de | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node2 | ZTE | E9000 | 281498500179 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.10 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:02:49 | 3c:da:2a:e8:02:4c | 3c:da:2a:e9:02:d0 | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:d2 | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node3 | ZTE | E9000 | 281498500008 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.11 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:a4 | 3c:da:2a:e8:01:a7 | 3c:da:2a:e9:02:ec | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:ee | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node4 | ZTE | E9000 | 281498500157 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.12 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:c7 | 3c:da:2a:e8:01:ca | 3c:da:2a:e9:02:d4 | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:d6 | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node5 | ZTE | E9000 | 281498500119 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.13 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:b3 | 3c:da:2a:e8:01:b6 | 3c:da:2a:e9:02:ac | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:ae | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
+**Nodes/Servers**
+
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node1 | ZTE | E9000 | 701763100114 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.106 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cd:6f | 74:4a:a4:00:cd:72 | 74:4a:a4:00:b0:e9 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:ea | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:b0:eb | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:ec | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node2 | ZTE | E9000 | 701360500105 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.107 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ca:c9 | 74:4a:a4:00:ca:cc | 74:4a:a4:00:d6:a3 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a4 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:99 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9a | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node3 | ZTE | E9000 | 701360500026 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.108 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cd:0f | 74:4a:a4:00:cd:12 | 74:4a:a4:00:d6:9d | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9e | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d3:15 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d3:16 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node4 | ZTE | E9000 | 701763100099 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.109 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cf:3d | 74:4a:a4:00:cf:40 | 74:4a:a4:00:d6:a5 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a6 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a7 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a8 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node5 | ZTE | E9000 | 701763100018 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.110 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ce:d1 | 74:4a:a4:00:ce:d4 | 74:4a:a4:00:d2:c3 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c4 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c1 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c2 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+
**Subnet allocations**
+----------------+--------------+----------------+------------+-----------------+
| Network name | Address | Mask | Gateway | VLAN id |
+----------------+--------------+----------------+------------+-----------------+
-| Public | 172.30.0.0 | 255.255.255.0 | 172.30.0.1 | Untagged |
+| Public | 172.70.0.0 | 255.255.255.0 | 172.70.0.1 | 173 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Admin | 10.20.1.0 | 255.255.255.0 | 10.20.1.1 | native vlan 500 |
+| Fuel Admin | 10.20.7.0 | 255.255.255.0 | 10.20.7.1 | native vlan 170 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Mangement | 192.168.30.0 | 255.255.255.0 | | 501 |
+| Fuel Mangement | 192.168.71.0 | 255.255.255.0 | | 171 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Storage | 192.168.31.0 | 255.255.255.0 | | 502 |
+| Fuel Storage | 192.168.72.0 | 255.255.255.0 | | 172 |
+----------------+--------------+----------------+------------+-----------------+
diff --git a/docs/labs/zte-sh-lab/pod2_inventory.yaml b/docs/labs/zte-sh-lab/pod2_inventory.yaml
index c060a78f..a49ac190 100644
--- a/docs/labs/zte-sh-lab/pod2_inventory.yaml
+++ b/docs/labs/zte-sh-lab/pod2_inventory.yaml
@@ -2,48 +2,45 @@ nodes:
- name: node1
tags: control #optional param, other valid value "compute"
arch: "x86_64"
- mac_address: "3c:da:2a:e8:01:ed" #pxe boot interface mac
+ mac_address: "74:4A:A4:00:CD:72" #pxe boot interface mac
power:
type: ipmi
- address: 129.5.1.9
+ address: 192.168.1.106
user: zteroot
pass: superuser
- name: node2
tags: control
arch: "x86_64"
- mac_address: "3c:da:2a:e8:02:4c"
+ mac_address: "74:4A:A4:00:CA:CC"
power:
type: ipmi
- address: 129.5.1.10
+ address: 192.168.1.107
user: zteroot
pass: superuser
- name: node3
tags: control
arch: "x86_64"
- mac_address: "3c:da:2a:e8:01:a7"
+ mac_address: "74:4A:A4:00:CD:12"
power:
type: ipmi
- address: 129.5.1.11
+ address: 192.168.1.108
user: zteroot
pass: superuser
-
- name: node4
tags: compute
arch: "x86_64"
- mac_address: "3c:da:2a:e8:01:ca"
+ mac_address: "74:4A:A4:00:CF:40"
power:
type: ipmi
- address: 129.5.1.12
+ address: 192.168.1.109
user: zteroot
pass: superuser
-
- name: node5
tags: compute
arch: "x86_64"
- mac_address: "3c:da:2a:e8:01:b6"
+ mac_address: "74:4A:A4:00:CE:D4"
power:
type: ipmi
- address: 129.5.1.13
+ address: 192.168.1.110
user: zteroot
pass: superuser
-