summaryrefslogtreecommitdiffstats
path: root/docs/labs/zte-sh-lab/pod2_description.rst
diff options
context:
space:
mode:
Diffstat (limited to 'docs/labs/zte-sh-lab/pod2_description.rst')
-rw-r--r--docs/labs/zte-sh-lab/pod2_description.rst126
1 files changed, 76 insertions, 50 deletions
diff --git a/docs/labs/zte-sh-lab/pod2_description.rst b/docs/labs/zte-sh-lab/pod2_description.rst
index 1931ba56..961aa2a0 100644
--- a/docs/labs/zte-sh-lab/pod2_description.rst
+++ b/docs/labs/zte-sh-lab/pod2_description.rst
@@ -47,65 +47,91 @@ POD2 share the same **Deploy Server** with POD1.
+-----------+--------+-------+---------------+-----------+--------+-----------+--------------------+------------------+-------+
-**Compute Nodes**
-
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node1 | ZTE | E9000 | 281498500141 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.9 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:ea | 3c:da:2a:e8:01:ed | 3c:da:2a:e9:02:dc | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:de | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node2 | ZTE | E9000 | 281498500179 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.10 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:02:49 | 3c:da:2a:e8:02:4c | 3c:da:2a:e9:02:d0 | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:d2 | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node3 | ZTE | E9000 | 281498500008 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.11 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:a4 | 3c:da:2a:e8:01:a7 | 3c:da:2a:e9:02:ec | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:ee | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node4 | ZTE | E9000 | 281498500157 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.12 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:c7 | 3c:da:2a:e8:01:ca | 3c:da:2a:e9:02:d4 | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:d6 | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
-| node5 | ZTE | E9000 | 281498500119 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.13 | enp129s0f0: | enp2s0f0: | |
-| | | | | | | | 3c:da:2a:e8:01:b3 | 3c:da:2a:e8:01:b6 | 3c:da:2a:e9:02:ac | |
-| | | | | | | | zteroot/superuser | vlan 500/PXE | vlan 500/ public | |
-| | | | | | | | | vlan 501/management | vlan 503/ private | |
-| | | | | | | | | | enp132s0f0: | |
-| | | | | | | | | | 3c:da:2a:e9:02:ae | |
-| | | | | | | | | | vlan 502/ storage | |
-+----------+--------+-------+---------------+-----------+--------+-----------+---------------------+---------------------+-------------------+-------+
+**Nodes/Servers**
+
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node1 | ZTE | E9000 | 701763100114 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.106 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cd:6f | 74:4a:a4:00:cd:72 | 74:4a:a4:00:b0:e9 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:ea | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:b0:eb | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:b0:ec | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node2 | ZTE | E9000 | 701360500105 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.107 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ca:c9 | 74:4a:a4:00:ca:cc | 74:4a:a4:00:d6:a3 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a4 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:99 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9a | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node3 | ZTE | E9000 | 701360500026 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.108 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cd:0f | 74:4a:a4:00:cd:12 | 74:4a:a4:00:d6:9d | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:9e | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d3:15 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d3:16 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node4 | ZTE | E9000 | 701763100099 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.109 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:cf:3d | 74:4a:a4:00:cf:40 | 74:4a:a4:00:d6:a5 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a6 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a7 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d6:a8 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+| node5 | ZTE | E9000 | 701763100018 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.110 | ens4f0: | ens12f0: | |
+| | | | | | | | 74:4a:a4:00:ce:d1 | 74:4a:a4:00:ce:d4 | 74:4a:a4:00:d2:c3 | |
+| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | |
+| | | | | | | | | | ens12f1: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c4 | |
+| | | | | | | | | | vlan 172/ storage | |
+| | | | | | | | | | ens44f0: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c1 | |
+| | | | | | | | | | vlan 1130/ private | |
+| | | | | | | | | | ens44f1: | |
+| | | | | | | | | | 74:4a:a4:00:d2:c2 | |
+| | | | | | | | | | vlan 173/ public | |
++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+
+
**Subnet allocations**
+----------------+--------------+----------------+------------+-----------------+
| Network name | Address | Mask | Gateway | VLAN id |
+----------------+--------------+----------------+------------+-----------------+
-| Public | 172.30.0.0 | 255.255.255.0 | 172.30.0.1 | Untagged |
+| Public | 172.70.0.0 | 255.255.255.0 | 172.70.0.1 | 173 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Admin | 10.20.1.0 | 255.255.255.0 | 10.20.1.1 | native vlan 500 |
+| Fuel Admin | 10.20.7.0 | 255.255.255.0 | 10.20.7.1 | native vlan 170 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Mangement | 192.168.30.0 | 255.255.255.0 | | 501 |
+| Fuel Mangement | 192.168.71.0 | 255.255.255.0 | | 171 |
+----------------+--------------+----------------+------------+-----------------+
-| Fuel Storage | 192.168.31.0 | 255.255.255.0 | | 502 |
+| Fuel Storage | 192.168.72.0 | 255.255.255.0 | | 172 |
+----------------+--------------+----------------+------------+-----------------+