diff options
Diffstat (limited to 'nfvbenchvm/dib/elements/nfvbenchvm/static/etc')
8 files changed, 436 insertions, 110 deletions
diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modprobe.d/vfio.conf b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modprobe.d/vfio.conf new file mode 100644 index 0000000..f32633f --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modprobe.d/vfio.conf @@ -0,0 +1 @@ +options vfio enable_unsafe_noiommu_mode=1 diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modules-load.d/vfio-pci.conf b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modules-load.d/vfio-pci.conf new file mode 100644 index 0000000..7ce4214 --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/modules-load.d/vfio-pci.conf @@ -0,0 +1 @@ +vfio-pci diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/openstack/clouds.yaml b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/openstack/clouds.yaml new file mode 100644 index 0000000..cb1130f --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/openstack/clouds.yaml @@ -0,0 +1 @@ +# clouds.yaml file
\ No newline at end of file diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/profile.d/nfvbench.sh b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/profile.d/nfvbench.sh new file mode 100644 index 0000000..a9bf588 --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/profile.d/nfvbench.sh @@ -0,0 +1 @@ +#!/bin/bash diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local deleted file mode 100644 index caf3142..0000000 --- a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local +++ /dev/null @@ -1,110 +0,0 @@ -#!/bin/bash - -touch /var/lock/subsys/local - -# Waiting for cloud-init to generate $TESTPMD_CONF, retry 60 seconds -NFVBENCH_CONF=/etc/nfvbenchvm.conf -retry=30 -until [ $retry -eq 0 ]; do - if [ -f $NFVBENCH_CONF ]; then break; fi - retry=$[$retry-1] - sleep 2 -done -if [ ! -f $NFVBENCH_CONF ]; then - exit 0 -fi - -# Parse and obtain all configurations -echo "Generating configurations for forwarder..." -eval $(cat $NFVBENCH_CONF) -touch /nfvbench_configured.flag -NICS=`lspci -D | grep Ethernet | cut -d' ' -f1 | xargs` -PCI_ADDRESS_1=`echo $NICS | awk '{ print $1 }'` -PCI_ADDRESS_2=`echo $NICS | awk '{ print $2 }'` -CPU_CORES=`grep -c ^processor /proc/cpuinfo` -CPU_MASKS=0x`echo "obase=16; 2 ^ $CPU_CORES - 1" | bc` -WORKER_CORES=`expr $CPU_CORES - 1` - -# CPU isolation optimizations -echo 1 > /sys/bus/workqueue/devices/writeback/cpumask -echo 1 > /sys/devices/virtual/workqueue/cpumask -echo 1 > /proc/irq/default_smp_affinity -for irq in `ls /proc/irq/`; do - echo 1 > /proc/irq/$irq/smp_affinity -done -tuna -c $(seq -s, 1 1 $WORKER_CORES) --isolate - -# Sometimes the interfaces on the loopback VM will use different drivers, e.g. -# one from vswitch which is virtio based, one is from SRIOV VF. In this case, -# we have to make sure the forwarder uses them in the right order, which is -# especially important if the VM is in a PVVP chain. -SWAP_FLAG=0 -if [ $INTF_MAC1 ] && [ $INTF_MAC2 ]; then - NET_PATH=/sys/class/net - EXP_INTF_1=$(for f in $(ls $NET_PATH/); do if grep -q "$INTF_MAC1" $NET_PATH/$f/address; then echo $f; break; fi; done) - EXP_PCI_ADDRESS_1=$(ethtool -i $EXP_INTF_1 | grep "bus-info" | awk -F' ' '{ print $2 }') - EXP_INTF_2=$(for f in $(ls $NET_PATH/); do if grep -q "$INTF_MAC2" $NET_PATH/$f/address; then echo $f; break; fi; done) - EXP_PCI_ADDRESS_2=$(ethtool -i $EXP_INTF_2 | grep "bus-info" | awk -F' ' '{ print $2 }') - if [ "$PCI_ADDRESS_1" == "$EXP_PCI_ADDRESS_2" ] && [ "$PCI_ADDRESS_2" == "$EXP_PCI_ADDRESS_1" ]; then - # Interfaces are not coming in the expected order: - # (1) Swap the traffic generator MAC in the case of testpmd; - # (2) Swap the interface configs in the case of VPP; - SWAP_FLAG=1 - fi -fi - -# Configure the forwarder -if [ -z "`lsmod | grep igb_uio`" ]; then - modprobe uio - insmod /dpdk/igb_uio.ko -fi -if [ "$FORWARDER" == "testpmd" ]; then - echo "Configuring testpmd..." - if [ $SWAP_FLAG -eq 1 ]; then - TEMP=$TG_MAC1; TG_MAC1=$TG_MAC2; TG_MAC2=$TEMP - fi - # Binding ports to DPDK - /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_1 - /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_2 - screen -dmSL testpmd /dpdk/testpmd \ - -c $CPU_MASKS \ - -n 4 \ - -- \ - --burst=32 \ - --txd=256 \ - --rxd=1024 \ - --eth-peer=0,$TG_MAC1 \ - --eth-peer=1,$TG_MAC2 \ - --forward-mode=mac \ - --nb-cores=$WORKER_CORES \ - --max-pkt-len=9000 \ - --cmdline-file=/dpdk/testpmd_cmd.txt -else - echo "Configuring vpp..." - cp /vpp/startup.conf /etc/vpp/startup.conf - cp /vpp/vm.conf /etc/vpp/vm.conf - - sed -i "s/{{PCI_ADDRESS_1}}/$PCI_ADDRESS_1/g" /etc/vpp/startup.conf - sed -i "s/{{PCI_ADDRESS_2}}/$PCI_ADDRESS_2/g" /etc/vpp/startup.conf - sed -i "s/{{WORKER_CORES}}/$WORKER_CORES/g" /etc/vpp/startup.conf - service vpp start - sleep 10 - - INTFS=`vppctl show int | grep Ethernet | xargs` - INTF_1=`echo $INTFS | awk '{ print $1 }'` - INTF_2=`echo $INTFS | awk '{ print $4 }'` - if [ $SWAP_FLAG -eq 1 ]; then - TEMP=$INTF_1; INTF_1=$INTF_2; INTF_2=$TEMP - fi - sed -i "s/{{INTF_1}}/${INTF_1//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{INTF_2}}/${INTF_2//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{VNF_GATEWAY1_CIDR}}/${VNF_GATEWAY1_CIDR//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{VNF_GATEWAY2_CIDR}}/${VNF_GATEWAY2_CIDR//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_MAC1}}/${TG_MAC1}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_MAC2}}/${TG_MAC2}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_NET1}}/${TG_NET1//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_NET2}}/${TG_NET2//\//\/}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_GATEWAY1_IP}}/${TG_GATEWAY1_IP}/g" /etc/vpp/vm.conf - sed -i "s/{{TG_GATEWAY2_IP}}/${TG_GATEWAY2_IP}/g" /etc/vpp/vm.conf - service vpp restart -fi diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.generator b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.generator new file mode 100644 index 0000000..9ac23a3 --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.generator @@ -0,0 +1,122 @@ +#!/bin/bash + +touch /var/lock/subsys/local + +# Waiting for cloud-init to generate $NFVBENCH_CONF, retry 60 seconds +NFVBENCH_CONF=/etc/nfvbenchvm.conf +retry=30 +until [ $retry -eq 0 ]; do + if [ -f $NFVBENCH_CONF ]; then break; fi + retry=$[$retry-1] + sleep 2 +done +if [ ! -f $NFVBENCH_CONF ]; then + exit 0 +fi + +# Parse and obtain all configurations +echo "Generating configurations for NFVbench and TRex..." +eval $(cat $NFVBENCH_CONF) +touch /nfvbench_configured.flag + +# Add DNS entry +if [ $DNS_SERVERS ]; then + IFS="," read -a dns <<< $DNS_SERVERS + for d in "${dns[@]}"; do + echo "nameserver $d" >> /etc/resolv.conf + done +fi + +# CPU isolation optimizations +echo 1 > /sys/bus/workqueue/devices/writeback/cpumask +echo 1 > /sys/devices/virtual/workqueue/cpumask +echo 1 > /proc/irq/default_smp_affinity +for irq in `ls /proc/irq/`; do + if [ -f /proc/irq/$irq/smp_affinity ]; then + echo 1 > /proc/irq/$irq/smp_affinity + fi +done + +NET_PATH=/sys/class/net + +get_eth_port() { + # device mapping for CentOS Linux 7: + # lspci: + # 00.03.0 Ethernet controller: Red Hat, Inc. Virtio network device + # 00.04.0 Ethernet controller: Red Hat, Inc. Virtio network device + # /sys/class/net: + # /sys/class/net/eth0 -> ../../devices/pci0000:00/0000:00:03.0/virtio0/net/eth0 + # /sys/class/net/eth1 -> ../../devices/pci0000:00/0000:00:04.0/virtio1/net/eth1 + + mac=$1 + for f in $(ls $NET_PATH/); do + if grep -q "$mac" $NET_PATH/$f/address; then + eth_port=$(readlink $NET_PATH/$f | cut -d "/" -f8) + # some virtual interfaces match on MAC and do not have a PCI address + if [ "$eth_port" -a "$eth_port" != "N/A" ]; then + # Found matching interface + logger "NFVBENCHVM: found interface $f ($eth_port) matching $mac" + break + else + eth_port="" + fi + fi; + done + if [ -z "$eth_port" ]; then + echo "ERROR: Cannot find eth port for MAC $mac" >&2 + logger "NFVBENCHVM ERROR: Cannot find eth port for MAC $mac" + return 1 + fi + echo $eth_port + return 0 +} + +# Set VM MANAGEMENT port up and running +if [ $INTF_MGMT_CIDR ] && [ $INTF_MGMT_IP_GW ]; then + if [ $INTF_MAC_MGMT ]; then + ETH_PORT=$(get_eth_port $INTF_MAC_MGMT) + elif [ "$CLOUD_DETAIL" ] && [ "$PORT_MGMT_NAME" ]; then + $INTF_MAC_MGMT=$(openstack --os-cloud $CLOUD_DETAIL port list | grep $PORT_MGMT_NAME | grep -o -Ei '([a-fA-F0-9:]{17}|[a-fA-F0-9]{12}$)' | head -1) + ETH_PORT=$(get_eth_port $INTF_MAC_MGMT) + else + ETH_PORT="" + fi + if [ -z "$ETH_PORT" ]; then + echo "ERROR: Cannot find eth port for management port" >&2 + logger "NFVBENCHVM ERROR: Cannot find eth port for management port" + return 1 + fi + + # By default, configure the MTU of the management interface to the + # conservative value of 1500: this will reduce the risk to get an + # unmanageable VM in some setups. + # + # To set the MTU to a different value, configure the INTF_MGMT_MTU variable + # in /etc/nfvbenchvm.conf. If INTF_MGMT_MTU is set to the special value + # "auto", the MTU will not be configured and it will keep the value set by + # the hypervisor ("legacy" nfvbenchvm behavior). If INTF_MGMT_MTU is unset, + # the MTU will be set to 1500. In other cases, the MTU will be set to the + # value of INTF_MGMT_MTU. + # + if [[ -z "$INTF_MGMT_MTU" ]]; then + ip link set $ETH_PORT mtu 1500 + elif [[ "$INTF_MGMT_MTU" != "auto" ]]; then + ip link set $ETH_PORT mtu $INTF_MGMT_MTU + fi + + ip addr add $INTF_MGMT_CIDR dev $ETH_PORT + ip link set $ETH_PORT up + ip route add default via $INTF_MGMT_IP_GW dev $ETH_PORT +else + echo "INFO: VM management IP Addresses missing in $NFVBENCH_CONF" +fi + +/nfvbench/configure-nfvbench.sh + +if [ $ACTION ]; then + /nfvbench/start-nfvbench.sh $ACTION +else + /nfvbench/start-nfvbench.sh +fi + +exit 0 diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.loopvm b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.loopvm new file mode 100644 index 0000000..181ff2a --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local.loopvm @@ -0,0 +1,298 @@ +#!/bin/bash + +touch /var/lock/subsys/local + +# Waiting for cloud-init to generate $NFVBENCH_CONF, retry 60 seconds +NFVBENCH_CONF=/etc/nfvbenchvm.conf +retry=30 +until [ $retry -eq 0 ]; do + if [ -f $NFVBENCH_CONF ]; then break; fi + retry=$[$retry-1] + sleep 2 +done +if [ ! -f $NFVBENCH_CONF ]; then + exit 0 +fi + +# Parse and obtain all configurations +echo "Generating configurations for forwarder..." +eval $(cat $NFVBENCH_CONF) +touch /nfvbench_configured.flag + +# WE assume there are at least 2 cores available for the VM +CPU_CORES=$(grep -c ^processor /proc/cpuinfo) + +# We need at least 1 admin core. +if [ $CPU_CORES -le 2 ]; then + ADMIN_CORES=1 +else + # If the number of cores is even we + # reserve 2 cores for admin (second being idle) so the number of + # workers is either 1 (if CPU_CORES is 2) or always even + if (( $CPU_CORES % 2 )); then + ADMIN_CORES=1 + else + ADMIN_CORES=2 + fi +fi +# 2 vcpus: AW (core 0: Admin, core 1: Worker) +# 3 vcpus: AWW (core 0: Admin, core 1,2: Worker) +# 4 vcpus: AWWU (core 0: Admin, core 1,2: Worker, core 3: Unused) +# 5 vcpus: AWWWW +# 6 vcpus: AWWWWU +WORKER_CORES=$(expr $CPU_CORES - $ADMIN_CORES) +# worker cores are all cores except the admin core (core 0) and the eventual unused core +# AW -> 1 +# AWW -> 1,2 +# AWWU -> 1,2 +WORKER_CORE_LIST=$(seq -s, $ADMIN_CORES $WORKER_CORES) +# always use all cores +CORE_MASK=0x$(echo "obase=16; 2 ^ $CPU_CORES - 1" | bc) + +logger "NFVBENCHVM: CPU_CORES=$CPU_CORES, ADMIN_CORES=$ADMIN_CORES, WORKER_CORES=$WORKER_CORES ($WORKER_CORE_LIST)" + +# CPU isolation optimizations +echo 1 > /sys/bus/workqueue/devices/writeback/cpumask +echo 1 > /sys/devices/virtual/workqueue/cpumask +echo 1 > /proc/irq/default_smp_affinity +for irq in `ls /proc/irq/`; do + if [ -f /proc/irq/$irq/smp_affinity ]; then + echo 1 > /proc/irq/$irq/smp_affinity + fi +done + +# Isolate all cores that are reserved for workers +tuna -c $WORKER_CORE_LIST --isolate + +NET_PATH=/sys/class/net + +get_pci_address() { + # device mapping for CentOS Linux 7: + # lspci: + # 00.03.0 Ethernet controller: Red Hat, Inc. Virtio network device + # 00.04.0 Ethernet controller: Red Hat, Inc. Virtio network device + # /sys/class/net: + # /sys/class/net/eth0 -> ../../devices/pci0000:00/0000:00:03.0/virtio0/net/eth0 + # /sys/class/net/eth1 -> ../../devices/pci0000:00/0000:00:04.0/virtio1/net/eth1 + + mac=$1 + for f in $(ls $NET_PATH/); do + if grep -q "$mac" $NET_PATH/$f/address; then + pci_addr=$(readlink $NET_PATH/$f | cut -d "/" -f5) + # some virtual interfaces match on MAC and do not have a PCI address + if [ "$pci_addr" -a "$pci_addr" != "N/A" ]; then + # Found matching interface + logger "NFVBENCHVM: found interface $f ($pci_addr) matching $mac" + break + else + pci_addr="" + fi + fi; + done + if [ -z "$pci_addr" ]; then + echo "ERROR: Cannot find pci address for MAC $mac" >&2 + logger "NFVBENCHVM ERROR: Cannot find pci address for MAC $mac" + return 1 + fi + echo $pci_addr + return 0 +} + +get_eth_port() { + # device mapping for CentOS Linux 7: + # lspci: + # 00.03.0 Ethernet controller: Red Hat, Inc. Virtio network device + # 00.04.0 Ethernet controller: Red Hat, Inc. Virtio network device + # /sys/class/net: + # /sys/class/net/eth0 -> ../../devices/pci0000:00/0000:00:03.0/virtio0/net/eth0 + # /sys/class/net/eth1 -> ../../devices/pci0000:00/0000:00:04.0/virtio1/net/eth1 + + mac=$1 + for f in $(ls $NET_PATH/); do + if grep -q "$mac" $NET_PATH/$f/address; then + eth_port=$(readlink $NET_PATH/$f | cut -d "/" -f8) + # some virtual interfaces match on MAC and do not have a PCI address + if [ "$eth_port" -a "$eth_port" != "N/A" ]; then + # Found matching interface + logger "NFVBENCHVM: found interface $f ($eth_port) matching $mac" + break + else + eth_port="" + fi + fi; + done + if [ -z "$eth_port" ]; then + echo "ERROR: Cannot find eth port for MAC $mac" >&2 + logger "NFVBENCHVM ERROR: Cannot find eth port for MAC $mac" + return 1 + fi + echo $eth_port + return 0 +} + +# Set VM MANAGEMENT port up and running +if [ $INTF_MGMT_CIDR ] && [ $INTF_MGMT_IP_GW ]; then + if [ $INTF_MAC_MGMT ]; then + ETH_PORT=$(get_eth_port $INTF_MAC_MGMT) + else + ETH_PORT="eth0" + fi + + # By default, configure the MTU of the management interface to the + # conservative value of 1500: this will reduce the risk to get an + # unmanageable VM in some setups. + # + # To set the MTU to a different value, configure the INTF_MGMT_MTU variable + # in /etc/nfvbenchvm.conf. If INTF_MGMT_MTU is set to the special value + # "auto", the MTU will not be configured and it will keep the value set by + # the hypervisor ("legacy" nfvbenchvm behavior). If INTF_MGMT_MTU is unset, + # the MTU will be set to 1500. In other cases, the MTU will be set to the + # value of INTF_MGMT_MTU. + # + if [[ -z "$INTF_MGMT_MTU" ]]; then + ip link set $ETH_PORT mtu 1500 + elif [[ "$INTF_MGMT_MTU" != "auto" ]]; then + ip link set $ETH_PORT mtu $INTF_MGMT_MTU + fi + + ip addr add $INTF_MGMT_CIDR dev $ETH_PORT + ip link set $ETH_PORT up + ip route add default via $INTF_MGMT_IP_GW dev $ETH_PORT +else + echo "INFO: VM management IP Addresses missing in $NFVBENCH_CONF" +fi + +# Set dynamically interfaces mac values, if VM is spawn without using NFVBench +# and management interface is used on eth0 +if [ -z "$INTF_MAC1" ] && [ -z "$INTF_MAC2" ]; then + INTF_MAC1=$(ip l show eth1 | grep -o -Ei '([a-fA-F0-9:]{17}|[a-fA-F0-9]{12}$)' | head -1) + INTF_MAC2=$(ip l show eth2 | grep -o -Ei '([a-fA-F0-9:]{17}|[a-fA-F0-9]{12}$)' | head -1) +fi + + +# Sometimes the interfaces on the loopback VM will use different drivers, e.g. +# one from vswitch which is virtio based, one is from SRIOV VF. In this case, +# we have to make sure the forwarder uses them in the right order, which is +# especially important if the VM is in a PVVP chain. +if [ $INTF_MAC1 ] && [ $INTF_MAC2 ]; then + PCI_ADDRESS_1=$(get_pci_address $INTF_MAC1) + PCI_ADDRESS_2=$(get_pci_address $INTF_MAC2) +else + echo "ERROR: VM MAC Addresses missing in $NFVBENCH_CONF" + logger "NFVBENCHVM ERROR: VM MAC Addresses missing in $NFVBENCH_CONF" +fi + +wait_vpp_service() { + # Wait for at most wait_max=$1 seconds until VPP service is ready. Exit + # with code 1 if timeout is reached. + # + # Because VPP systemd unit has Type=simple, systemctl will report the + # service to be active has soon as it is forked. This does not mean that + # the service is ready, and actually it takes some times before vppctl can + # succesfully connect to VPP client socket /run/vpp/cli.sock. + local wait_max=$1 + + local wait_time=0 + while ! vppctl show int; do + if [[ $wait_time -ge $wait_max ]]; then + # Log error to both system log and standard error output + logger -s "NFVBENCHVM ERROR: VPP service still not ready after $wait_max seconds." \ + "Exiting $(basename $0)." + exit 1 + fi + sleep 1 + wait_time=$(( wait_time + 1 )) + done +} + +if [ $PCI_ADDRESS_1 ] && [ $PCI_ADDRESS_2 ]; then + logger "NFVBENCHVM: Using pci $PCI_ADDRESS_1 ($INTF_MAC1)" + logger "NFVBENCHVM: Using pci $PCI_ADDRESS_2 ($INTF_MAC2)" + # active uio_pci_generic driver + modprobe uio_pci_generic + # Configure the forwarder + if [ "$FORWARDER" == "testpmd" ]; then + echo "Configuring testpmd..." + mkdir /dpdk + echo "set promisc all off" > /dpdk/testpmd_cmd.txt + # Binding ports to DPDK VFIO or UIO + dpdk-devbind -b vfio-pci $PCI_ADDRESS_1 || dpdk-devbind -b uio_pci_generic $PCI_ADDRESS_1 + dpdk-devbind -b vfio-pci $PCI_ADDRESS_2 || dpdk-devbind -b uio_pci_generic $PCI_ADDRESS_2 + screen -dmSL testpmd testpmd \ + -c $CORE_MASK \ + -n 4 \ + -- \ + --nb-ports=2 \ + --burst=32 \ + --txd=256 \ + --rxd=1024 \ + --eth-peer=0,$TG_MAC1 \ + --eth-peer=1,$TG_MAC2 \ + --forward-mode=mac \ + --nb-cores=$WORKER_CORES \ + --txq=$VIF_MQ_SIZE \ + --rxq=$VIF_MQ_SIZE \ + --max-pkt-len=9000 \ + --cmdline-file=/dpdk/testpmd_cmd.txt + echo "testpmd running in screen 'testpmd'" + logger "NFVBENCHVM: testpmd running in screen 'testpmd'" + elif [ "$FORWARDER" == "vpp" ]; then + echo "Configuring vpp..." + cp /vpp/startup.conf /etc/vpp/startup.conf + cp /vpp/vm.conf /etc/vpp/vm.conf + + sed -i "s/{{PCI_ADDRESS_1}}/$PCI_ADDRESS_1/g" /etc/vpp/startup.conf + sed -i "s/{{PCI_ADDRESS_2}}/$PCI_ADDRESS_2/g" /etc/vpp/startup.conf + sed -i "s/{{WORKER_CORES}}/$WORKER_CORES/g" /etc/vpp/startup.conf + sed -i "s/{{VIF_MQ_SIZE}}/${VIF_MQ_SIZE}/g" /etc/vpp/startup.conf + sed -i "s/{{NUM_MBUFS}}/${NUM_MBUFS}/g" /etc/vpp/startup.conf + systemctl start vpp + # Wait until VPP service is ready for at most 30 seconds + wait_vpp_service 30 + + VPPCTL_OUTPUT=$(vppctl show int) + INTFS=$(echo "$VPPCTL_OUTPUT" | grep Ethernet | xargs) + INTF_1=$(echo $INTFS | awk '{ print $1 }') + INTF_2=$(echo $INTFS | awk '{ print $4 }') + if [[ -z "$INTF_1" ]] || [[ -z "$INTF_2" ]]; then + # Log error to both system log and standard error output + logger -s "NFVBENCHVM DEBUG: \"vppctl show int\" output:" + logger -s "NFVBENCHVM DEBUG: $VPPCTL_OUTPUT" + logger -s "NFVBENCHVM ERROR: vppctl does not show the two Ethernet interfaces we expect." \ + "Exiting $(basename $0)." + exit 1 + fi + if [ -z "${TG_MAC1}" ]; then + # vm.conf does not support lines commented with #, so + # we need to remove the line to set the static ARP entry. + sed -i "/{{TG_MAC1}}/d" /etc/vpp/vm.conf + else + sed -i "s/{{TG_MAC1}}/${TG_MAC1}/g" /etc/vpp/vm.conf + fi + if [ -z "${TG_MAC2}" ]; then + sed -i "/{{TG_MAC2}}/d" /etc/vpp/vm.conf + else + sed -i "s/{{TG_MAC2}}/${TG_MAC2}/g" /etc/vpp/vm.conf + fi + sed -i "s/{{INTF_1}}/${INTF_1//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{INTF_2}}/${INTF_2//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{VNF_GATEWAY1_CIDR}}/${VNF_GATEWAY1_CIDR//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{VNF_GATEWAY2_CIDR}}/${VNF_GATEWAY2_CIDR//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{TG_NET1}}/${TG_NET1//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{TG_NET2}}/${TG_NET2//\//\/}/g" /etc/vpp/vm.conf + sed -i "s/{{TG_GATEWAY1_IP}}/${TG_GATEWAY1_IP}/g" /etc/vpp/vm.conf + sed -i "s/{{TG_GATEWAY2_IP}}/${TG_GATEWAY2_IP}/g" /etc/vpp/vm.conf + systemctl restart vpp + logger "NFVBENCHVM: vpp service restarted" + else + echo "ERROR: Unknown forwarder value. Accepted values: testpmd or vpp" + exit 1 + fi +else + echo "ERROR: Cannot find PCI Address from MAC" + echo "$INTF_MAC1: $PCI_ADDRESS_1" + echo "$INTF_MAC2: $PCI_ADDRESS_2" + logger "NFVBENCHVM ERROR: Cannot find PCI Address from MAC" +fi + +exit 0 diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/systemd/system/nfvbench.service b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/systemd/system/nfvbench.service new file mode 100644 index 0000000..e952070 --- /dev/null +++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/systemd/system/nfvbench.service @@ -0,0 +1,12 @@ +[Unit] +Description=nfvbench service +After=network.target + +[Service] +Type=forking +User=root +RemainAfterExit=yes +ExecStart=/bin/bash -a -c "source /etc/profile.d/nfvbench.sh && /usr/bin/screen -dmSL nfvbench /usr/local/bin/nfvbench -c /etc/nfvbench/nfvbench.conf --server" + +[Install] +WantedBy=multi-user.target |