aboutsummaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
authorrexlee8776 <limingjiang@huawei.com>2018-04-12 06:53:17 +0000
committerRex Lee <limingjiang@huawei.com>2018-04-16 01:48:39 +0000
commit8014b2cb82136874795e7c1d819e0bb395499676 (patch)
tree9c2e8c235adac1a41c2762870e9354a70a601651 /docs
parent408ea589283fa8181679d5d0b999bcd6785e6086 (diff)
Bugfix: interface down HA tc050 attack and monitor logistic wrong
1. simplify the attack to be one interface 2. move monitor step before attack 3. update rst doc to match JIRA: YARDSTICK-1120 Change-Id: Icfa21d58e7ccdbeaca8a9a1a3098cceb21c981c3 Signed-off-by: rexlee8776 <limingjiang@huawei.com> (cherry picked from commit af7f0bea3a0d24bdf084622acc9932ccd261e42e)
Diffstat (limited to 'docs')
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc050.rst52
1 files changed, 25 insertions, 27 deletions
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
index 8890c9d53..82a491b72 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
@@ -34,23 +34,20 @@ Yardstick Test Case Description TC050
| | 2) host: which is the name of a control node being attacked. |
| | 3) interface: the network interface to be turned off. |
| | |
-| | There are four instance of the "close-interface" monitor: |
-| | attacker1(for public netork): |
-| | -fault_type: "close-interface" |
-| | -host: node1 |
-| | -interface: "br-ex" |
-| | attacker2(for management netork): |
-| | -fault_type: "close-interface" |
-| | -host: node1 |
-| | -interface: "br-mgmt" |
-| | attacker3(for storage netork): |
-| | -fault_type: "close-interface" |
-| | -host: node1 |
-| | -interface: "br-storage" |
-| | attacker4(for private netork): |
-| | -fault_type: "close-interface" |
-| | -host: node1 |
-| | -interface: "br-mesh" |
+| | The interface to be closed by the attacker can be set by the |
+| | variable of "{{ interface_name }}" |
+| | |
+| | attackers: |
+| | - |
+| | fault_type: "general-attacker" |
+| | host: {{ attack_host }} |
+| | key: "close-br-public" |
+| | attack_key: "close-interface" |
+| | action_parameter: |
+| | interface: {{ interface_name }} |
+| | rollback_parameter: |
+| | interface: {{ interface_name }} |
+| | |
+--------------+--------------------------------------------------------------+
|monitors | In this test case, the monitor named "openstack-cmd" is |
| | needed. The monitor needs needs two parameters: |
@@ -61,17 +58,17 @@ Yardstick Test Case Description TC050
| | |
| | There are four instance of the "openstack-cmd" monitor: |
| | monitor1: |
-| | -monitor_type: "openstack-cmd" |
-| | -command_name: "nova image-list" |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "nova image-list" |
| | monitor2: |
-| | -monitor_type: "openstack-cmd" |
-| | -command_name: "neutron router-list" |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "neutron router-list" |
| | monitor3: |
-| | -monitor_type: "openstack-cmd" |
-| | -command_name: "heat stack-list" |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "heat stack-list" |
| | monitor4: |
-| | -monitor_type: "openstack-cmd" |
-| | -command_name: "cinder list" |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "cinder list" |
+--------------+--------------------------------------------------------------+
|metrics | In this test case, there is one metric: |
| | 1)service_outage_time: which indicates the maximum outage |
@@ -109,9 +106,9 @@ Yardstick Test Case Description TC050
+--------------+--------------------------------------------------------------+
|step 2 | do attacker: connect the host through SSH, and then execute |
| | the turnoff network interface script with param value |
-| | specified by "interface". |
+| | specified by "{{ interface_name }}". |
| | |
-| | Result: Network interfaces will be turned down. |
+| | Result: The specified network interface will be down. |
| | |
+--------------+--------------------------------------------------------------+
|step 3 | stop monitors after a period of time specified by |
@@ -133,3 +130,4 @@ Yardstick Test Case Description TC050
| | execution problem. |
| | |
+--------------+--------------------------------------------------------------+
+