diff options
author | Martin Klozik <martin.klozik@tieto.com> | 2018-06-05 10:12:49 +0200 |
---|---|---|
committer | Martin Klozik <martin.klozik@tieto.com> | 2018-06-05 10:12:49 +0200 |
commit | 89018d21b6383f853a01c57a2270153d266fe087 (patch) | |
tree | cbedb55d5b6d5fdd1c61d71abdfe90a6c0ab55be /docs | |
parent | 3daf5942e2ede8088898a9589d41b797e27b6d4e (diff) |
ovs: Change default bridge names
Default names of OVS bridges used by vsperf were changed
to avoid accidental collision with 3rd party bridges
(e.g. linux bridges) already configured at DUT.
Step driven testcases, which extend existing deployment
scenarios, were updated to use appropriate configuration
options instead of hardcoded bridge names.
JIRA: VSPERF-580
Change-Id: I8c7eee6d8f6532485ec3a2cc06f26515e665fb7e
Signed-off-by: Martin Klozik <martin.klozik@tieto.com>
Reviewed-by: Al Morton <acmorton@att.com>
Reviewed-by: Christian Trautman <ctrautma@redhat.com>
Reviewed-by: Sridhar Rao <sridhar.rao@spirent.com>
Reviewed-by: Richard Elias <richard.elias@tieto.com>
Diffstat (limited to 'docs')
-rw-r--r-- | docs/testing/user/userguide/integration.rst | 4 | ||||
-rw-r--r-- | docs/testing/user/userguide/teststeps.rst | 14 | ||||
-rw-r--r-- | docs/testing/user/userguide/trafficcapture.rst | 8 |
3 files changed, 13 insertions, 13 deletions
diff --git a/docs/testing/user/userguide/integration.rst b/docs/testing/user/userguide/integration.rst index 2b2246db..9d847fd8 100644 --- a/docs/testing/user/userguide/integration.rst +++ b/docs/testing/user/userguide/integration.rst @@ -69,8 +69,8 @@ the following variables in you user_settings.py file: VTEP_IP2_SUBNET = '192.168.240.0/24' # Bridge names - TUNNEL_INTEGRATION_BRIDGE = 'br0' - TUNNEL_EXTERNAL_BRIDGE = 'br-ext' + TUNNEL_INTEGRATION_BRIDGE = 'vsperf-br0' + TUNNEL_EXTERNAL_BRIDGE = 'vsperf-br-ext' # IP of br-ext TUNNEL_EXTERNAL_BRIDGE_IP = '192.168.240.1/24' diff --git a/docs/testing/user/userguide/teststeps.rst b/docs/testing/user/userguide/teststeps.rst index 3f91a9d2..cb627bc5 100644 --- a/docs/testing/user/userguide/teststeps.rst +++ b/docs/testing/user/userguide/teststeps.rst @@ -798,20 +798,20 @@ and available in both csv and rst report files. }, }, "TestSteps": [ - ['vswitch', 'add_vport', 'br0'], - ['vswitch', 'add_vport', 'br0'], + ['vswitch', 'add_vport', '$VSWITCH_BRIDGE_NAME'], + ['vswitch', 'add_vport', '$VSWITCH_BRIDGE_NAME'], # priority must be higher than default 32768, otherwise flows won't match - ['vswitch', 'add_flow', 'br0', + ['vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '1', 'actions': ['output:#STEP[-2][1]'], 'idle_timeout': '0', 'dl_type':'0x0800', 'nw_proto':'17', 'tp_dst':'0', 'priority': '33000'}], - ['vswitch', 'add_flow', 'br0', + ['vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '2', 'actions': ['output:#STEP[-2][1]'], 'idle_timeout': '0', 'dl_type':'0x0800', 'nw_proto':'17', 'tp_dst':'0', 'priority': '33000'}], - ['vswitch', 'add_flow', 'br0', {'in_port': '#STEP[-4][1]', 'actions': ['output:1'], + ['vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '#STEP[-4][1]', 'actions': ['output:1'], 'idle_timeout': '0'}], - ['vswitch', 'add_flow', 'br0', {'in_port': '#STEP[-4][1]', 'actions': ['output:2'], + ['vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '#STEP[-4][1]', 'actions': ['output:2'], 'idle_timeout': '0'}], - ['vswitch', 'dump_flows', 'br0'], + ['vswitch', 'dump_flows', '$VSWITCH_BRIDGE_NAME'], ['vnf1', 'start'], ] }, diff --git a/docs/testing/user/userguide/trafficcapture.rst b/docs/testing/user/userguide/trafficcapture.rst index fa09bfed..8a224dcb 100644 --- a/docs/testing/user/userguide/trafficcapture.rst +++ b/docs/testing/user/userguide/trafficcapture.rst @@ -92,9 +92,9 @@ An example of Traffic Capture in VM test: }, TestSteps: [ # replace original flows with vlan ID modification - ['!vswitch', 'add_flow', 'br0', {'in_port': '1', 'actions': ['mod_vlan_vid:4','output:3']}], - ['!vswitch', 'add_flow', 'br0', {'in_port': '2', 'actions': ['mod_vlan_vid:4','output:4']}], - ['vswitch', 'dump_flows', 'br0'], + ['!vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '1', 'actions': ['mod_vlan_vid:4','output:3']}], + ['!vswitch', 'add_flow', '$VSWITCH_BRIDGE_NAME', {'in_port': '2', 'actions': ['mod_vlan_vid:4','output:4']}], + ['vswitch', 'dump_flows', '$VSWITCH_BRIDGE_NAME'], # verify that received frames have modified vlan ID ['VNF0', 'execute_and_wait', 'tcpdump -i eth0 -c 5 -w dump.pcap vlan 4 &'], ['trafficgen', 'send_traffic',{}], @@ -199,7 +199,7 @@ An example of Traffic Capture for testing NICs with HW offloading test: ['tools', 'exec_shell_background', 'tcpdump -i [2][device] -c 5 -w capture.pcap ' 'ether src [l2][srcmac]'], ['trafficgen', 'send_traffic', {}], - ['vswitch', 'dump_flows', 'br0'], + ['vswitch', 'dump_flows', '$VSWITCH_BRIDGE_NAME'], ['vswitch', 'dump_flows', 'br1'], # there must be 5 captured frames... ['tools', 'exec_shell', 'tcpdump -r capture.pcap | wc -l', '|^(\d+)$'], |