diff options
author | Qiaowei Ren <qiaowei.ren@intel.com> | 2018-01-04 13:43:33 +0800 |
---|---|---|
committer | Qiaowei Ren <qiaowei.ren@intel.com> | 2018-01-05 11:59:39 +0800 |
commit | 812ff6ca9fcd3e629e49d4328905f33eee8ca3f5 (patch) | |
tree | 04ece7b4da00d9d2f98093774594f4057ae561d4 /src/ceph/doc/rbd/iscsi-initiator-esx.rst | |
parent | 15280273faafb77777eab341909a3f495cf248d9 (diff) |
initial code repo
This patch creates initial code repo.
For ceph, luminous stable release will be used for base code,
and next changes and optimization for ceph will be added to it.
For opensds, currently any changes can be upstreamed into original
opensds repo (https://github.com/opensds/opensds), and so stor4nfv
will directly clone opensds code to deploy stor4nfv environment.
And the scripts for deployment based on ceph and opensds will be
put into 'ci' directory.
Change-Id: I46a32218884c75dda2936337604ff03c554648e4
Signed-off-by: Qiaowei Ren <qiaowei.ren@intel.com>
Diffstat (limited to 'src/ceph/doc/rbd/iscsi-initiator-esx.rst')
-rw-r--r-- | src/ceph/doc/rbd/iscsi-initiator-esx.rst | 36 |
1 files changed, 36 insertions, 0 deletions
diff --git a/src/ceph/doc/rbd/iscsi-initiator-esx.rst b/src/ceph/doc/rbd/iscsi-initiator-esx.rst new file mode 100644 index 0000000..18dd583 --- /dev/null +++ b/src/ceph/doc/rbd/iscsi-initiator-esx.rst @@ -0,0 +1,36 @@ +---------------------------------- +The iSCSI Initiator for VMware ESX +---------------------------------- + +**Prerequisite:** + +- VMware ESX 6.0 or later + +**iSCSI Discovery and Multipath Device Setup:** + +#. From vSphere, open the Storage Adapters, on the Configuration tab. Right click + on the iSCSI Software Adapter and select Properties. + +#. In the General tab click the "Advanced" button and in the "Advanced Settings" + set RecoveryTimeout to 25. + +#. If CHAP was setup on the iSCSI gateway, in the General tab click the "CHAP…" + button. If CHAP is not being used, skip to step 4. + +#. On the CHAP Credentials windows, select “Do not use CHAP unless required by target”, + and enter the "Name" and "Secret" values used on the initial setup for the iSCSI + gateway, then click on the "OK" button. + +#. On the Dynamic Discovery tab, click the "Add…" button, and enter the IP address + and port of one of the iSCSI target portals. Click on the "OK" button. + +#. Close the iSCSI Initiator Properties window. A prompt will ask to rescan the + iSCSI software adapter. Select Yes. + +#. In the Details pane, the LUN on the iSCSI target will be displayed. Right click + on a device and select "Manage Paths". + +#. On the Manage Paths window, select “Most Recently Used (VMware)” for the policy + path selection. Close and repeat for the other disks. + +Now the disks can be used for datastores. |