summaryrefslogtreecommitdiffstats
path: root/VNFs/DPPD-PROX/helper-scripts/rapid/deploycentostools.sh
AgeCommit message (Collapse)AuthorFilesLines
2021-11-02Create combined image and add helm chartYury Kylulin1-1/+8
Changes in this commit: 1) Create self contained image, rapid scripts can be executed from the management pod and create other testing pods in the cluster. 2) Helm chart to automate rapid deployment and proper service account configuration to be able to start management pod. 3) Fix for migration to paramiko. Signed-off-by: Yury Kylulin <yury.kylulin@intel.com> Change-Id: I0281871cce392b3003e0274602a5c90c29af9b23
2021-06-08fix container image and use latest codeLuc Provoost1-10/+4
The container image was not containing a working prox executable any more. Also took out the commit id, so we always have the latest prox code in the latest container image Change-Id: I4336e06031d5bf5b3f08f4bc32b76703fde34040 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2021-03-15Fix the tuned optimizationsLuc Provoost1-3/+3
tuned-adm is now run through check_prox_system_setup.sh at the first system startup/reboot. This will result in the correct grub cmdline parameters. We are also coying the default rapid_rsa_key in the authorized_keys of the rapid user, which is now the default user to run the tests. Fixed also an issue in handle_mirror.c: using now ETYPE_IPv4. Changed deploycentostools.sh to reflect the changes done when building the image with disk-image-create. Change-Id: I5933d21faef9fe02b56c01d0b96e2c143cc5476d Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2021-01-29Add rapid script sources in the imageYury Kylulin1-17/+21
Make image more universal and add rapid scripts for mgmt from the container. Signed-off-by: Yury Kylulin <yury.kylulin@intel.com> Change-Id: Ia46a8e147f978dd64bfe6c7b44f7dff92e241855
2020-09-29New PROX version, background traffic reportingLuc Provoost1-2/+2
deploycentostools.sh is now installing a recent PROX version. When using background traffic, the tool is also reporting the total traffic that was handled by the NFVi stack, including foreground & background traffic. The use of the prox_socket and prox_launch_exit was also broken in a previous release and is now fixed. When setting prox_socket to false for a PROX instance, we will not create a socket connection to control that PROX instance. Setting this option to false is not meaningful for the generator PROX instances since we would not be able to control the behavior of the PROX generator during the test. You could use the generator against another non-PROX instance and then set prox_socket to false for that non-PROX instance. Default is true. prox_launch_exit is used to start and stop the PROX program inside the instance. Default is true. This is useful in case you want to start PROX manually to be able to inspect the PROX UI, but at the same time, let the rapid scripts control the testing. Change-Id: Ib5aa809f4be201859542769f5f55f4989dad97ef Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-09-07deploycentostools.sh to use latest PROXLuc Provoost1-1/+1
Rapid scripts are communicating to the PROX instances. Rapid scripts will not work with every PROX version sice sometime we change the interface between the scripts and PROX. Hence we have a commit ID in deploycentostools.sh to make sure we have a version of PROX that we can work with. This change will now ensure we have a recent PROX version when we use deploycentostools.sh to build an image. Change-Id: Ia634f61a2dc8f49188cec6697ebf5f980d35ce7d Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-07-05Adding vdev support and vfioLuc Provoost1-26/+17
Using vfio in stead of igb_uio. DPDK 2020.5 is NOT compiling the igb_uio driver by default any more. For the l3 mode, we are now using the new PROX vdev feature. This is achieved by adding the vdev parameter in the port section of the PROX config files. One of the advantages is that we can now ping a port managed by PROX: the requests will be forwarded by PROX to the LINUX stack, who will reply to the ping. A tap device is being created by PROX to support this feature. Installing old version of nasm since latest causes some issues. If not pushgateway is being used, it should be commented out in the config_file. vfio is now loaded by specifying the module in /etc/modules-load.d There is also an after_boot.sh script that will be run by check_prox_system_setup.sh, which can be used for further configuration of the instance after boot. There is now also a file created /opt/rapid/system_ready_for_rapid by the check_prox_system_setup.sh script. This file is created once all configuration is done. The runrapid.py script will wait till this file is created before executing any tests. Change-Id: Ic5c41af82642066af42134c3323297f5a06f6f72 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-06-03Fix for containers to use /opt/rapidYury Kylulin1-4/+4
Fix scripts and build procedure to use /opt/rapid as a main directory for binaries and config files. Signed-off-by: Yury Kylulin <yury.kylulin@intel.com> Change-Id: Icb38c37a85a78a6f2de2e751df5fafd624b4f1b3
2020-06-02Using /opt/rapid to run proxLuc Provoost1-4/+4
All config files are now copied into /opt/rapid. We are not using the home directory any more. The prox executable is now also copied into the same /opt/rapid. Change-Id: I838636167f370bf8a855a3cfb0796c659e27a3ad Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-05-29Fix for container .env file and small updatesLuc Provoost1-1/+1
Since runrapid.py is now supporting more than 1 dataplane interface, we need to use a port index in the rapid.env file for the dataplane ports. In k8sdeployment.py, we only support 1 dataplane port, but we are writing dp_ip1 and dp_mac1 in the environment file. The copyright dates are also updated. Some references to VM have also been changed to instance. Change-Id: Ie1d036c13ef5d6f0aa1f35aa068a9760a1cfc2a9 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-05-28IPV6 testing & minor changes and fixesLuc Provoost1-19/+12
IPV6 test has been added. The generator will now generate IPV6 packets using NDP to resolve MAC addresses. The hex IP addresses in the inline definition of the packets in the cfg files is now calculated by a lua function called in parameters.lua. The hard-coded path /home/centos has been replaced by ~. An error in the speed calculations has been fixed. See the RapidTest class for details. The actual number of generated flows is now reported. If the requested number of flows is not a power of 2, the lowest power of 2 that is larger than the requested number of flows will be used and reported. Change-Id: I36b8d345b4a03c2cf358c19ec353ca8ad2831293 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-05-15Support for imix packet sizesLuc Provoost1-2/+6
All packet size in the *.test files have been replaces with imix sizes. imix is now a list of packet sizes. If you want to run with only a pakcet size of 64, you need to specify a list containing only 1 size: [64]. You can also specify multiple imix values by specifying a list of list of sizes. The keyworkds in the test files are now imix & imixs. Change-Id: Iea47c0266b022133b7bbfc9a6811e3199ae41521 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-05-15createrapid.py is now using heat templates yamlLuc Provoost1-1/+13
yaml files have been added to the repo as an example. Please check the README explaining the output section reqs for this yaml file. There is also a new file (config_file): it also specifies which yaml files to use. multiple dataplane interfaces per VM can now be specified and will appear in the <STACK>.env file. An error in setting the packet size has been fixed (see set_udp_packet_size for packet size setting details) Change-Id: Ie89a4940521dac7dd3652acca477739abb9f5497 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-01-31Add support for kubernetes deployment in rapid scripts.Yury Kylulin1-31/+181
In case of kubernetes based deployments procedure for test environment creation is different. Please refer to README.k8s file for more details. Dockerfile and dockerimage.sh files can be used to create a docker image with prox. There is separate createrapidk8s.py script which is used to create appropriate number of PODs for testing based on the rapid.pods configuration. port_info is a helper application to identify port MAC address. Change-Id: I73611f066ac54260aa11dd17c173379df06f46a5 Signed-off-by: Yury Kylulin <yury.kylulin@intel.com> Signed-off-by: Patrice Buriez <patrice.buriez@intel.com>
2020-01-31New PROX commit ID and bug fixLuc Provoost1-1/+1
Updated deploycentos.sh with latest PROX commit ID and took another code review comment into account. Change-Id: Iedfa695be7496459d990f36e2dc00c8890b19fb3 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-01-29code review comments and PROX commit IDLuc Provoost1-4/+3
Implemented the code review comments I got on previous commits and using commit ID 2cd03b7 to select the PROX version that will be installed in the VMs through deploycentostools.sh Change-Id: Ifc4c18c657a8bd57c68a7fc9d885c75ffdcb7b5d Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2020-01-23Fix run_iteration when not using the sut_sockLuc Provoost1-1/+6
When no sut_sock monitoring the swap, the while loop would never come to an end. Also added heartbeat timeout in the generator config files. Change-Id: I3c36991c65b9b826faf3d051a1354ca7eb34c24e Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2019-11-26rapid november release combining changesLuc Provoost1-17/+16
-Renamed monitorswap.test into corestats.test. This is a more generic test case that can monitor the core statistics of all PROX instances -New portstats.test which can monitor the port statistics of all PROX instances -Removed the tasks parameter in the [DEFAULT] section of the *.test files. Runrapid.py is now scaning the PROX configuration files to automatically detect the PROX tasks that are being used. -There is now an option to add the PushGateway parameter in the [Default] section of some *.test files. This will push the measurements to the Gateway, so they can be used by tools like Grafana. The logging of the data in a csv file has also been improved. Results can now be found on the screen, in the RUN*.log files, in the *.csv files and are being pushed to the PushGateway. -In the *.test files, replaced the swapcores, irqcores and impaircores by the cores parameter since they are not treated differently by the code. For a generator, we are still using the gencores and latcores parameters since we need to treat them differently in runrapid.py -devbind.sh is removed from the repository since this file is now created by runrapid.py -renamed the rapidVMs.vms file into rapid.vms -image is now built without ssh access for root. Only using centos user. runrapid.py is now using centos user for ssh sessions. PROX tools are strted using sudo -using new DPDK, mb_lib and PROX versions as defined in deploycentostools.sh -installing missing yum-utils package in image -added flowsize parameter to the impairtest -added list of flowsizes to the fixed_rate testing (l3framerate.test) -the irqtest can now loop through multiple Test Machines in stead of only checking the irq of one. Note that we should have the same cores parameter for all Test machines -changes in prox_ctrl.py to support setting the speed of a generator on a combination of mulitple cores and tasks. Also added the multi_port_stats function to support the new portstats.test -Updated version to 19.11.21 -Fixed some power of 2 in the flow table Change-Id: Ia14543bf3195a2b1bd4184b455da6940f1777fc9 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2019-07-05Some fixes after code reviewLuc Provoost1-1/+0
Taking into account comments from Patrice and Xavier Change-Id: Ifdabd1945e074c9ee97b059956f107901392c020 Signed-off-by: Luc Provoost <luc.provoost@intel.com>
2019-06-30Multiple changes for June releaseLuc Provoost1-0/+148
- Change inittest in warmuptest. This has now a warmuptime, warmupspeed, packet size and flow size. - Change in centos.json. This will now also copy deploycentostools.sh during image building so that it can be used to re-compile prox in the VM by typing "./deploycentostools.sh compile" - runrapid.py parameters needing a file name, need to be complete file names: no extensions will be added any more by the scripts. - Changes in createrapid.py to handel the openstack CLI output in a simpler way. - The management interface of the VMs can now also be an SRIOV interface. We have now an extra optional parameter in the VM sections of the rapiVMs.vms file: SRIOV_mgmt_port - Changed the name of some sections and keys in the environment file since runrapid.py will not always communicate to OpenStack VMs. This could be containers or any other (virtual) machine. - The previous MachineMap.cfg has been renamed to machine.map - A new test has been added: monitorswap is just showing the statistics of a swap (virtual) machine, without generating any packets. This is useful in situations where an external tester is used. - Latency and core statistics can now be measured even if there are multiple PROX cores and tasks running. A new parameter has been added in the test files with following default value: tasks=[0]. During the collection of statistics, all tasks in this list will be queried. It is ok to have a non-existing task in such a query since it will be ignored. - A --screenlog parameter was added for runrapid.py allowing for more detailed output on the screen during debugging. No need to check the log file. - Previous tests to run multiple packet size with a given flow size and to run multiple flow size, with a given packet size are now combined by specifiying 2 lists: packetsizes & flows - The screen output of this test has also been reworked with more meaningful column names and the test result is now in the field "core received". This allows also for faster termination of the test: When the all packets sent by Gen NIC are received by the cores within the thresholds for packet loss and latency, the test is now stopped, even we were requesting more packets to be sent. Change-Id: I3307e7a972f2140e739f376f146fe875df0303e6 Signed-off-by: Luc Provoost <luc.provoost@intel.com>