diff --git a/docs/labs/orange-paris-lab/orange_paris_pod1_description.rst b/docs/labs/orange-paris-lab/orange_paris_pod1_description.rst
deleted file mode 100644
index 75dcfdd5..00000000
--- a/docs/labs/orange-paris-lab/orange_paris_pod1_description.rst
+++ /dev/null
@@ -1,129 +0,0 @@
-.. This work is licensed under a Creative Commons Attribution 4.0 International License.
-.. http://creativecommons.org/licenses/by/4.0
-
-**************************
-POD Specification Template
-**************************
-
-Introduction
-------------
-
-Orange is hosting an OPNFV test lab at Chatillon (near Paris) facility. The test lab would host 4
-(1 controller and 3 computes) baremetal servers for the use of OPNFV community as part of the OPNFV
-Pharos Project.
-
-Version: Brahmaputra
-Installer: Fuel (with Ceph)
-
-Additional Requirements
------------------------
-
-Server Specifications
----------------------
-
-**Switch**
-
-+-----------+----------+---------+---------------+-------+--------+---------+---------------------+------------------+------------------+----------+
-| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+-----------+----------+---------+---------------+-------+--------+---------+---------------------+------------------+------------------+----------+
-| pod1- | JUNIPER | EX-4550 | 750-045407 | | | | 172.31.2.254 | | | 32 ports |
-| switch | | | | | | | CC:E1:7F:86:38:80 | | | |
-| | | | | | | | | | | |
-+-----------+----------+---------+---------------+-------+--------+---------+---------------------+------------------+------------------+----------+
-
-**Jump Host**
-
-+-----------+---------+----------+---------------+----------------+--------+-----------+---------------------+------------------+------------------+-------+
-| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+-----------+---------+----------+---------------+----------------+--------+-----------+---------------------+------------------+------------------+-------+
-| pod1- | DELL | Proliant | CZJ40901PV | Intel Xeon | 16 GB | 300GB SAS | | IF0: 172.31.13.5 | | |
-| jump-host | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | | | |
-| | | Gen8 | | 2,5Ghz 24 core | | | | | | |
-+-----------+---------+----------+---------------+----------------+--------+-----------+---------------------+------------------+------------------+-------+
-
-**Firewall**
-
-+-----------+---------+------------+---------------+-------------+--------+-----------+---------------------+--------------------+------------------+-------+
-| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+-----------+---------+------------+---------------+-------------+--------+-----------+---------------------+--------------------+------------------+-------+
-| pod1- | IBM | @Server | | Intel Xeon | 4 GB | 36GB SATA | | IF0: 161.105.211.2 | | |
-| firewall | | xSerie 336 | KKTVY4M | | | 36GB SATA | | | | |
-| | | | | | | | | | | |
-+-----------+---------+------------+---------------+-------------+--------+-----------+---------------------+--------------------+------------------+-------+
-
-**Controller Node**
-
-+------------+---------+-----------+---------------+---------------+--------+-----------+---------------------+------------------------+------------------+-------+
-| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+------------+---------+-----------+---------------+---------------+--------+-----------+---------------------+------------------------+------------------+-------+
-| pod1-ctrl1 | HP | Proliant | CZJ40901PT | Intel Xeon | 16GB | 300GB SAS | | IF0: 9C:B6:54:95:E4:74 | | |
-| | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | Admin | | |
-| | | Gen8 | | 2,5Ghz | | | | IF1: 9C:B6:54:95:E4:75 | | |
-| | | | | 24 core | | | | 18: Public | | |
-| | | | | | | | | 1500: Storage | | |
-| | | | | | | | | 17: Management | | |
-| | | | | | | | | 1502: Private | | |
-+------------+---------+-----------+---------------+---------------+--------+-----------+---------------------+------------------------+------------------+-------+
-
-**Compute Nodes**
-
-+------------+---------+-----------+---------------+---------------+----------+------------+---------------------+------------------------+------------------+-------+
-| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
-| Hostname | Vendor | Model | Serial Number | CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
-+------------+---------+-----------+---------------+---------------+----------+------------+---------------------+------------------------+------------------+-------+
-| pod1-node1 | DELL | R730 | 8F3J642 | Intel Xeon | 128GB | 250GB SATA | | IF0: EC:F4:BB:CB:62:9C | | |
-| | | | | E5-2603 v3 | (8x16GB) | 480GB SSD | | Admin | | |
-| | | | | 1,6Ghz | 1600Mhz | 480GB SSD | | IF1: EC:F4:BB:CB:62:9A | | |
-| | | | | 12 core | | | | 18: Public | | |
-| | | | | | | | | 1500: Storage | | |
-| | | | | | | | | 17: Management | | |
-| | | | | | | | | 1502: Private | | |
-+------------+---------+-----------+---------------+---------------+----------+------------+---------------------+------------------------+------------------+-------+
-| pod1-node2 | HP | Proliant | CZJ40901PS | Intel Xeon | 16GB | 300GB SAS | | IF0: 9C:B6:54:95:D4:F0 | | |
-| | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | Admin | | |
-| | | Gen8 | | 2,5Ghz | | | | IF1: 9C:B6:54:95:D4:F1 | | |
-| | | | | 24 core | | | | 18: Public | | |
-| | | | | | | | | 1500: Storage | | |
-| | | | | | | | | 17: Management | | |
-| | | | | | | | | 1502: Private | | |
-+------------+---------+-----------+---------------+---------------+----------+------------+---------------------+------------------------+------------------+-------+
-| pod1-node3 | DELL | R730 | FG3J642 | Intel Xeon | 128GB | 256GB SATA | | IF0: EC:F4:BB:CB:62:E4 | | |
-| | | | | E5-2603 v3 | (8x16GB) | 480GB SSD | | Admin | | |
-| | | | | 1,6Ghz | 1600Mhz | 480GB SSD | | IF1: EC:F4:BB:CB:62:E2 | | |
-| | | | | 12 core | | | | 18: Public | | |
-| | | | | | | | | 1500: Storage | | |
-| | | | | | | | | 17: Management | | |
-| | | | | | | | | 1502: Private | | |
-+------------+---------+-----------+---------------+---------------+----------+------------+---------------------+------------------------+------------------+-------+
-
-Users
------
-
-+------+-------+---------+------+-------+
-| Name | Email | Company | Role | Notes |
-+------+-------+---------+------+-------+
-| | | | | |
-+------+-------+---------+------+-------+
-
-Firewall Rules
---------------
-
-+------------+------------+------+
-| Port(s) | Service | Note |
-+------------+------------+------+
-| 22, 43, 80 | Jenkins CI | |
-+------------+------------+------+
-
-POD Topology
-------------
-
-Provide a diagram showing the network topology of the POD. Any security sensitive details should not
-be exposed publically and can be stored in the secure Pharos repo. The following diagram is an
-example only.
-
-.. image:: ./images/orange_paris_pod1.jpg
- :alt: POD diagram not found