summaryrefslogtreecommitdiffstats
path: root/docs/labs
diff options
context:
space:
mode:
authorTrevor Cooper <trevor.cooper@intel.com>2016-01-22 13:27:04 -0800
committerChristopherPrice <christopher.price@ericsson.com>2016-01-28 18:31:24 +0100
commit6a28ba866d3c0cd05041d9196c3bb0e2340bd2e7 (patch)
treea765c18b6975e5d6fc19bcd226ca7c28a8915095 /docs/labs
parentc4e926c285db44a5ec5ba4a895c8d3889e3358c0 (diff)
Removed old lab description template and replaced with new template.
Updates for ... 1) Lab description 2) POD description 3) Examples of lab tolpology and POD topology diagrams. These files were created using ideas from existing lab/POD descriptions and lab experience for rls B. (cp) provided some tidying up and random spelling fixes for the toolchain. Change-Id: I72a34be9e1c1509fd310b43562bf6d5aa1c459e7 Signed-off-by: Trevor Cooper <trevor.cooper@intel.com>
Diffstat (limited to 'docs/labs')
-rw-r--r--docs/labs/Dell.rst735
-rw-r--r--docs/labs/huawei-us-lab/huawei-us-lab.pngbin0 -> 947340 bytes
-rw-r--r--docs/labs/huawei-us-lab/huawei-us-lab.rst107
-rw-r--r--docs/labs/huawei-us-lab/index.rst19
-rw-r--r--docs/labs/huawei-us-lab/pod-network.pngbin0 -> 28059 bytes
-rw-r--r--docs/labs/spirent.rst18
6 files changed, 491 insertions, 388 deletions
diff --git a/docs/labs/Dell.rst b/docs/labs/Dell.rst
index c0c47506..f5916b8e 100644
--- a/docs/labs/Dell.rst
+++ b/docs/labs/Dell.rst
@@ -1,378 +1,357 @@
-Dell OPNFV Testlab
-==================================================
-
-Overview
-------------------
-
-Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
-
-
-The Dell Testlab consists of 2 PODs
- * POD1 for Fuel
- * POD2 for Foreman
-
-.. image:: images/Dell_Overview.jpg
- :height: 553
- :width: 449
- :alt: Dell Testlab Overiew
- :align: left
-
-Each of the 2 PODs consists of 6 servers that consist of
- * 1 Jump Server
- * 3 Servers for Control Nodes
- * 2 Servers for Compute Nodes
-
-
-
-Hardware details
------------------
-
-All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:
-
-
-
-**POD1-Fuel**
-
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname | Model | Memory | Storage | Processor | Socket |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-
-
-
-
-**POD2-Foreman**
-
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname | Model | Memory | Storage | Processor | Socket |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-
-
-
-
-
-Software
----------
-
-The Jump servers in the Testlab are pre-provisioned with the following softwares:
-
- * Fuel-Jump Server:
-
- 1. OS: Ubuntu 14.04
-
-
- * Foreman-Jump Server:
-
- 1. OS: CentOS7
-
-
-
-
-
-Networks
-----------
-
-
-
-**POD1-Fuel**
-
-.. image:: images/Dell_POD1.jpg
- :height: 647
- :width: 821
- :alt: POD1-Fuel Overview
- :align: left
-
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname | NIC Model | Ports|MAC | BW | Roles |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-
-
-
-**POD2-Foreman**
-
-.. image:: images/Dell_POD2.jpg
- :height: 721
- :width: 785
- :alt: POD2-Foreman Overview
- :align: left
-
-
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname | NIC Model | Ports|MAC | BW | Roles |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-
-
-
-
-
-
-**Subnet allocations**
-
-+-------------------+----------------+-------------------+---------------+----------+
-| Network name | Address | Mask | Gateway | VLAN id |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-
-
-**Lights out Network**
-
-**POD1**
-
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname | Lights-out address | MAC | Username | Password |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-
-**POD2**
-
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname | Lights-out address | MAC | Username | Password |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-
-
-
-
-
-
-Remote access infrastructure
------------------------------
-
-The Dell OPNFV testlab is free to use for the OPNFV community.
-
-A VPN is used to provide access to the Dell Testlab.
-
-To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
- * Name
- * Email
- * Designation
- * Organization
- * Purpose of using the lab
-
- Processing the request can take 2-3 business days.
-
-*Accessing the Teslab*
------------------------
-
-* POD1 JumpServer
-
- IP: 172.18.0.67
-
- User: opnfv
-
- Passwd: d3ll1234
-
-
-
-* POD2 JumpServer
-
- IP: 172.18.0.11
-
- User: opnfv
-
- Passwd: d3ll1234
-
+Dell OPNFV Testlab
+==================================================
+
+Overview
+------------------
+
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers
+for the use of OPNFV community as part of the OPNFV Pharos Project
+
+
+The Dell Testlab consists of 2 PODs
+ * POD1 for Fuel
+ * POD2 for Foreman
+
+.. image:: images/Dell_Overview.jpg
+ :height: 553
+ :width: 449
+ :alt: Dell Testlab Overiew
+ :align: left
+
+Each of the 2 PODs consists of 6 servers that consist of
+ * 1 Jump Server
+ * 3 Servers for Control Nodes
+ * 2 Servers for Compute Nodes
+
+
+
+Hardware details
+-----------------
+
+All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the
+following specifications:
+
+POD1-Fuel
+^^^^^^^^^
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+POD2-Foreman
+^^^^^^^^^^^^
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+Software
+---------
+
+The Jump servers in the Testlab are pre-provisioned with the following softwares:
+
+ * Fuel-Jump Server:
+
+ 1. OS: Ubuntu 14.04
+
+
+ * Foreman-Jump Server:
+
+ 1. OS: CentOS7
+
+Networks
+----------
+
+POD1-Fuel
+^^^^^^^^^
+.. image:: images/Dell_POD1.jpg
+ :height: 647
+ :width: 821
+ :alt: POD1-Fuel Overview
+ :align: left
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+POD2-Foreman
+^^^^^^^^^^^^
+
+.. image:: images/Dell_POD2.jpg
+ :height: 721
+ :width: 785
+ :alt: POD2-Foreman Overview
+ :align: left
+
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+Subnet allocations
+^^^^^^^^^^^^^^^^^^
+
++-------------------+----------------+-------------------+---------------+----------+
+| Network name | Address | Mask | Gateway | VLAN id |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+
+
+Lights out Network
+^^^^^^^^^^^^^^^^^^
+
+**POD1**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+**POD2**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+
+Remote access infrastructure
+-----------------------------
+
+The Dell OPNFV testlab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Dell Testlab.
+
+To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
+ * Name
+ * Email
+ * Designation
+ * Organization
+ * Purpose of using the lab
+
+Processing the request can take 2-3 business days.
+
+*Accessing the Teslab*
+----------------------
+
+POD1 JumpServer
+^^^^^^^^^^^^^^^
+
+ IP: 172.18.0.67
+ User: opnfv
+ Passwd: d3ll1234
+
+
+POD2 JumpServer
+^^^^^^^^^^^^^^^
+ IP: 172.18.0.11
+ User: opnfv
+ Passwd: d3ll1234
+
diff --git a/docs/labs/huawei-us-lab/huawei-us-lab.png b/docs/labs/huawei-us-lab/huawei-us-lab.png
new file mode 100644
index 00000000..26bd5092
--- /dev/null
+++ b/docs/labs/huawei-us-lab/huawei-us-lab.png
Binary files differ
diff --git a/docs/labs/huawei-us-lab/huawei-us-lab.rst b/docs/labs/huawei-us-lab/huawei-us-lab.rst
new file mode 100644
index 00000000..48b34ba7
--- /dev/null
+++ b/docs/labs/huawei-us-lab/huawei-us-lab.rst
@@ -0,0 +1,107 @@
+Introduction
+============
+
+Huawei's lab located in Santa Clara, CA will provide 1 full POD for baremetal deployment environment, 2
+standalone server for virtual deployment, and 1 server with 6 executors for project's building and gate-testing.
+All the resources have been attached to Jenkins master, you can view the slaves below
+in https://build.opnfv.org/ci/:
+
+* huawei-us-build-1
+* huawei-us-deploy-vm-1
+* huawei-us-deploy-vm-2
+* huawei-us-deploy-bare-1
+
+Overall Description
+===================
+
+Hardware
+--------
+
+* 9 Huawei RH2285H V2 Rack Servers (128 GB RAM , 4.7 TB SATA SSDs, two Intel Xeon E5-2400 v2 series processors)
+* 1 Huawei S9300 10G switch for storage, management and public traffic - 2x10GE to each server.
+* 1 Huawei S5300 1G switch for installing and Lights+out management traffic - 2x1GE to each server.
+* 1 VPN concentrator for remote access and management.
+* 1 Huawei firewall and router for public network secure access.
+
+
+Hosting Topology
+----------------
+.. image:: ./huawei-us-lab.png
+ :height: 1000
+ :width: 900
+ :alt: OPNFV
+ :align: left
+
+|
+|
+
+Figure 1: Huawei US lab OPNFV hosting environment overview
+
+
+POD Network
+-----------
+Below you'll find a topological view of the hosting set-up:
+
+.. image:: ./pod-network.png
+ :height: 950
+ :width: 900
+ :alt: OPNFV
+ :align: left
+
+|
+|
+
+Figure 2: Full Pod network configuration
+
+
+How to use our resources?
+=========================
+
+Build Resource
+^^^^^^^^^^^^^^
+
+You can see the slaves named "huawei-us-build-[digit]" or "huawei-build-[digit]" in https://build.opnfv.org/ci/
+
+These resources are dedicated to CI. If you want to use Huawei resource to run some automated jobs, you do
+not need to apply for the credentials, just specify the node as "huawei-build" . For other purposes, please
+contact: [[weidong.shao@huawei.com]]
+
+
+Deployment Resource
+^^^^^^^^^^^^^^^^^^^
+
+You can see the slaves named "huawei-us-deploy-vm/bare-[digit]" or "huawei-deploy-vm/bare-[digit]" in
+https://build.opnfv.org/ci/
+
+We have two types of deployment resources, virtual deployment environment and baremetal deployment environment.
+Both can be deployed by any types of installer, and provide the same testbed for testing and the same
+infrastructure for VNF.
+
+You can access our deployment resources by applying for the VPN credentials, please see the section below
+for details.
+
+
+Access
+======
+
+This environment is free to use by any OPNFV contributor or committer for the purpose of OPNFV approved
+activities, you just need to obtain VPN credentials to access.
+
+Access to this environment can be granted by sending a e-mail to:
+ * [[weidong.shao@huawei.com]]
+ * [[opnfv-helpdesk@rt.linuxfoundation.org]]
+
+Following information should be provided in the request:
+ * subject: opnfv_huawei_access
+ * Full name
+ * e-mail
+ * Phone
+ * Organization
+ * OPNFV Contributor/Committer name :
+ * OPNFV Project(s) Association:
+ * LF ID:
+ * Recommended by:
+ * PGP public key (preferably registered with a PGP PKI server)
+ * SSH public key
+
+Granting access normally takes 3-5 business days.
diff --git a/docs/labs/huawei-us-lab/index.rst b/docs/labs/huawei-us-lab/index.rst
new file mode 100644
index 00000000..34549b95
--- /dev/null
+++ b/docs/labs/huawei-us-lab/index.rst
@@ -0,0 +1,19 @@
+Introduction of Huawei's lab located in Santa Clara
+===================================================
+
+Contents:
+
+.. toctree::
+ :numbered:
+ :maxdepth: 8
+
+ documentation-example.rst
+
+Indices and tables
+==================
+
+* :ref:`search`
+
+Revision: _sha1_
+
+Build date: |today|
diff --git a/docs/labs/huawei-us-lab/pod-network.png b/docs/labs/huawei-us-lab/pod-network.png
new file mode 100644
index 00000000..8be1cf33
--- /dev/null
+++ b/docs/labs/huawei-us-lab/pod-network.png
Binary files differ
diff --git a/docs/labs/spirent.rst b/docs/labs/spirent.rst
index 4ec987bd..d5804ac6 100644
--- a/docs/labs/spirent.rst
+++ b/docs/labs/spirent.rst
@@ -1,7 +1,8 @@
Spirent Virtual Cloud Test Lab
===============================
-A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight, OpenStack, OPNFV projects.
+A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight,
+OpenStack, OPNFV projects.
**Spirent VCT Lab** is currently working on 3 different **OpenStack** environments each one of them deployed on different hardware configuration:
@@ -22,8 +23,12 @@ There are a number of different networks referenced in the VPTC Design Blueprint
These can be added or removed as specified by the test methodology.
There are 8 x 10 gige SFP+ ports available on a typical C100MP used for Avalanche Layer 4-7 testing.
The N4U offers 2 x 40 gige QSFP+ ports with the MX-2 Spirent Test Center Layer 2-3 testing.
-There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10 gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports.
-Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical traffic generators at the same time. Assuming a 10 to 1 oversubscription ratio we could handle 80 community users with the current environment.
+There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10
+gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports.
+Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical
+traffic generators at the same time. Assuming a 10 to 1 oversubscription ratio we could handle 80 community
+users with the current environment.
+
For example:
* An 80 Gbps test would need 4 port pairs of 10 gige each and require 8 mission networks.
@@ -32,10 +37,3 @@ For example:
* Stand-alone DUT servers using STCv and AVv traffic generators could easily scale to hundreds of servers as needed.
.. image:: iamges/spirent_vptc-public-drawing.png
-
-**Documentation tracking**
-
-Revision: _sha1_
-
-Build date: _date_
-