aboutsummaryrefslogtreecommitdiffstats
path: root/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local
diff options
context:
space:
mode:
authorahothan <ahothan@cisco.com>2019-05-13 10:34:15 -0700
committerahothan <ahothan@cisco.com>2019-05-16 16:21:57 -0700
commit7439c895c0ad2960712910ab6b72042884ce2a41 (patch)
treef1f03915eec5389d34b6180457e259b94212bf9b /nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local
parent82c15f5063f51104830ac111b392887486377655 (diff)
NFVBENCH-134 Support multiple idle interfaces per test VM
Enhance test VM to support auto-selection of PCI addresses based on MAC address Enhance syslog reporting in test VM Increase test VM version to 0.7 Add new properties to cfg.defaults.yaml to support idle interfaces Enhance cleanup to support idle networks and ports Change-Id: Ia89a2a1bee9eb5fb56f7adde074bdcec09cb0a3f Signed-off-by: ahothan <ahothan@cisco.com>
Diffstat (limited to 'nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local')
-rw-r--r--nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local164
1 files changed, 98 insertions, 66 deletions
diff --git a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local
index caf3142..94fbd74 100644
--- a/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local
+++ b/nfvbenchvm/dib/elements/nfvbenchvm/static/etc/rc.d/rc.local
@@ -18,9 +18,8 @@ fi
echo "Generating configurations for forwarder..."
eval $(cat $NFVBENCH_CONF)
touch /nfvbench_configured.flag
-NICS=`lspci -D | grep Ethernet | cut -d' ' -f1 | xargs`
-PCI_ADDRESS_1=`echo $NICS | awk '{ print $1 }'`
-PCI_ADDRESS_2=`echo $NICS | awk '{ print $2 }'`
+
+
CPU_CORES=`grep -c ^processor /proc/cpuinfo`
CPU_MASKS=0x`echo "obase=16; 2 ^ $CPU_CORES - 1" | bc`
WORKER_CORES=`expr $CPU_CORES - 1`
@@ -30,81 +29,114 @@ echo 1 > /sys/bus/workqueue/devices/writeback/cpumask
echo 1 > /sys/devices/virtual/workqueue/cpumask
echo 1 > /proc/irq/default_smp_affinity
for irq in `ls /proc/irq/`; do
- echo 1 > /proc/irq/$irq/smp_affinity
+ if [ -f /proc/irq/$irq/smp_affinity ]; then
+ echo 1 > /proc/irq/$irq/smp_affinity
+ fi
done
tuna -c $(seq -s, 1 1 $WORKER_CORES) --isolate
+NET_PATH=/sys/class/net
+
+get_pci_address() {
+ # device mapping for CentOS Linux 7:
+ # lspci:
+ # 00.03.0 Ethernet controller: Red Hat, Inc. Virtio network device
+ # 00.04.0 Ethernet controller: Red Hat, Inc. Virtio network device
+ # /sys/class/net:
+ # /sys/class/net/eth0 -> ../../devices/pci0000:00/0000:00:03.0/virtio0/net/eth0
+ # /sys/class/net/eth1 -> ../../devices/pci0000:00/0000:00:04.0/virtio1/net/eth1
+
+ mac=$1
+ for f in $(ls $NET_PATH/); do
+ if grep -q "$mac" $NET_PATH/$f/address; then
+ pci_addr=$(readlink $NET_PATH/$f | cut -d "/" -f5)
+ # some virtual interfaces match on MAC and do not have a PCI address
+ if [ "$pci_addr" -a "$pci_addr" != "N/A" ]; then
+ break
+ else
+ pci_addr=""
+ fi
+ fi;
+ done
+ if [ -z "$pci_addr" ]; then
+ echo "ERROR: Cannot find pci address for MAC $mac" >&2
+ logger "NFVBENCHVM ERROR: Cannot find pci address for MAC $mac"
+ return 1
+ fi
+ echo $pci_addr
+ return 0
+}
+
# Sometimes the interfaces on the loopback VM will use different drivers, e.g.
# one from vswitch which is virtio based, one is from SRIOV VF. In this case,
# we have to make sure the forwarder uses them in the right order, which is
# especially important if the VM is in a PVVP chain.
-SWAP_FLAG=0
if [ $INTF_MAC1 ] && [ $INTF_MAC2 ]; then
- NET_PATH=/sys/class/net
- EXP_INTF_1=$(for f in $(ls $NET_PATH/); do if grep -q "$INTF_MAC1" $NET_PATH/$f/address; then echo $f; break; fi; done)
- EXP_PCI_ADDRESS_1=$(ethtool -i $EXP_INTF_1 | grep "bus-info" | awk -F' ' '{ print $2 }')
- EXP_INTF_2=$(for f in $(ls $NET_PATH/); do if grep -q "$INTF_MAC2" $NET_PATH/$f/address; then echo $f; break; fi; done)
- EXP_PCI_ADDRESS_2=$(ethtool -i $EXP_INTF_2 | grep "bus-info" | awk -F' ' '{ print $2 }')
- if [ "$PCI_ADDRESS_1" == "$EXP_PCI_ADDRESS_2" ] && [ "$PCI_ADDRESS_2" == "$EXP_PCI_ADDRESS_1" ]; then
- # Interfaces are not coming in the expected order:
- # (1) Swap the traffic generator MAC in the case of testpmd;
- # (2) Swap the interface configs in the case of VPP;
- SWAP_FLAG=1
- fi
+ PCI_ADDRESS_1=$(get_pci_address $INTF_MAC1)
+ PCI_ADDRESS_2=$(get_pci_address $INTF_MAC2)
+else
+ echo "ERROR: VM MAC Addresses missing in $NFVBENCH_CONF"
+ logger "NFVBENCHVM ERROR: VM MAC Addresses missing in $NFVBENCH_CONF"
fi
-# Configure the forwarder
-if [ -z "`lsmod | grep igb_uio`" ]; then
- modprobe uio
- insmod /dpdk/igb_uio.ko
-fi
-if [ "$FORWARDER" == "testpmd" ]; then
- echo "Configuring testpmd..."
- if [ $SWAP_FLAG -eq 1 ]; then
- TEMP=$TG_MAC1; TG_MAC1=$TG_MAC2; TG_MAC2=$TEMP
+if [ $PCI_ADDRESS_1 ] && [ $PCI_ADDRESS_2 ]; then
+ logger "NFVBENCHVM: Using pci $PCI_ADDRESS_1 ($INTF_MAC1)"
+ logger "NFVBENCHVM: Using pci $PCI_ADDRESS_2 ($INTF_MAC2)"
+ # Configure the forwarder
+ if [ -z "`lsmod | grep igb_uio`" ]; then
+ modprobe uio
+ insmod /dpdk/igb_uio.ko
fi
- # Binding ports to DPDK
- /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_1
- /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_2
- screen -dmSL testpmd /dpdk/testpmd \
- -c $CPU_MASKS \
- -n 4 \
- -- \
- --burst=32 \
- --txd=256 \
- --rxd=1024 \
- --eth-peer=0,$TG_MAC1 \
- --eth-peer=1,$TG_MAC2 \
- --forward-mode=mac \
- --nb-cores=$WORKER_CORES \
- --max-pkt-len=9000 \
- --cmdline-file=/dpdk/testpmd_cmd.txt
-else
- echo "Configuring vpp..."
- cp /vpp/startup.conf /etc/vpp/startup.conf
- cp /vpp/vm.conf /etc/vpp/vm.conf
+ if [ "$FORWARDER" == "testpmd" ]; then
+ echo "Configuring testpmd..."
+ # Binding ports to DPDK
+ /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_1
+ /dpdk/dpdk-devbind.py -b igb_uio $PCI_ADDRESS_2
+ screen -dmSL testpmd /dpdk/testpmd \
+ -c $CPU_MASKS \
+ -n 4 \
+ -- \
+ --burst=32 \
+ --txd=256 \
+ --rxd=1024 \
+ --eth-peer=0,$TG_MAC1 \
+ --eth-peer=1,$TG_MAC2 \
+ --forward-mode=mac \
+ --nb-cores=$WORKER_CORES \
+ --max-pkt-len=9000 \
+ --cmdline-file=/dpdk/testpmd_cmd.txt
+ echo "testpmd running in screen 'testpmd'"
+ logger "NFVBENCHVM: testpmd running in screen 'testpmd'"
+ else
+ echo "Configuring vpp..."
+ cp /vpp/startup.conf /etc/vpp/startup.conf
+ cp /vpp/vm.conf /etc/vpp/vm.conf
- sed -i "s/{{PCI_ADDRESS_1}}/$PCI_ADDRESS_1/g" /etc/vpp/startup.conf
- sed -i "s/{{PCI_ADDRESS_2}}/$PCI_ADDRESS_2/g" /etc/vpp/startup.conf
- sed -i "s/{{WORKER_CORES}}/$WORKER_CORES/g" /etc/vpp/startup.conf
- service vpp start
- sleep 10
+ sed -i "s/{{PCI_ADDRESS_1}}/$PCI_ADDRESS_1/g" /etc/vpp/startup.conf
+ sed -i "s/{{PCI_ADDRESS_2}}/$PCI_ADDRESS_2/g" /etc/vpp/startup.conf
+ sed -i "s/{{WORKER_CORES}}/$WORKER_CORES/g" /etc/vpp/startup.conf
+ service vpp start
+ sleep 10
- INTFS=`vppctl show int | grep Ethernet | xargs`
- INTF_1=`echo $INTFS | awk '{ print $1 }'`
- INTF_2=`echo $INTFS | awk '{ print $4 }'`
- if [ $SWAP_FLAG -eq 1 ]; then
- TEMP=$INTF_1; INTF_1=$INTF_2; INTF_2=$TEMP
+ INTFS=`vppctl show int | grep Ethernet | xargs`
+ INTF_1=`echo $INTFS | awk '{ print $1 }'`
+ INTF_2=`echo $INTFS | awk '{ print $4 }'`
+ sed -i "s/{{INTF_1}}/${INTF_1//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{INTF_2}}/${INTF_2//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{VNF_GATEWAY1_CIDR}}/${VNF_GATEWAY1_CIDR//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{VNF_GATEWAY2_CIDR}}/${VNF_GATEWAY2_CIDR//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_MAC1}}/${TG_MAC1}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_MAC2}}/${TG_MAC2}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_NET1}}/${TG_NET1//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_NET2}}/${TG_NET2//\//\/}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_GATEWAY1_IP}}/${TG_GATEWAY1_IP}/g" /etc/vpp/vm.conf
+ sed -i "s/{{TG_GATEWAY2_IP}}/${TG_GATEWAY2_IP}/g" /etc/vpp/vm.conf
+ service vpp restart
+ logger "NFVBENCHVM: vpp service restarted"
fi
- sed -i "s/{{INTF_1}}/${INTF_1//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{INTF_2}}/${INTF_2//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{VNF_GATEWAY1_CIDR}}/${VNF_GATEWAY1_CIDR//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{VNF_GATEWAY2_CIDR}}/${VNF_GATEWAY2_CIDR//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_MAC1}}/${TG_MAC1}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_MAC2}}/${TG_MAC2}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_NET1}}/${TG_NET1//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_NET2}}/${TG_NET2//\//\/}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_GATEWAY1_IP}}/${TG_GATEWAY1_IP}/g" /etc/vpp/vm.conf
- sed -i "s/{{TG_GATEWAY2_IP}}/${TG_GATEWAY2_IP}/g" /etc/vpp/vm.conf
- service vpp restart
+else
+ echo "ERROR: Cannot find PCI Address from MAC"
+ echo "$INTF_MAC1: $PCI_ADDRESS_1"
+ echo "$INTF_MAC2: $PCI_ADDRESS_2"
+ logger "NFVBENCHVM ERROR: Cannot find PCI Address from MAC"
fi