summaryrefslogtreecommitdiffstats
path: root/fuel/docs/src/tmp/INSTALL/README
diff options
context:
space:
mode:
Diffstat (limited to 'fuel/docs/src/tmp/INSTALL/README')
-rw-r--r--fuel/docs/src/tmp/INSTALL/README154
1 files changed, 0 insertions, 154 deletions
diff --git a/fuel/docs/src/tmp/INSTALL/README b/fuel/docs/src/tmp/INSTALL/README
deleted file mode 100644
index 456e26d..0000000
--- a/fuel/docs/src/tmp/INSTALL/README
+++ /dev/null
@@ -1,154 +0,0 @@
-##############################################################################
-# Copyright (c) 2015 Ericsson AB and others.
-# stefan.k.berg@ericsson.com
-# jonas.bjurel@ericsson.com
-# All rights reserved. This program and the accompanying materials
-# are made available under the terms of the Apache License, Version 2.0
-# which accompanies this distribution, and is available at
-# http://www.apache.org/licenses/LICENSE-2.0
-##############################################################################
-
-
-This README file describes how to install the OPNFV BGS Stack
-=============================================================
-1.1 Install Fuel Server
------------------------
-1. Mount the built .iso file (release/opnfv-<version>.iso) as a bootdevice to the fuel server.
-
-2. Reboot the fuel server.
- The system now boots from the ISO image.
-
-3. Change the grub boot params
- When Press Tab to edit . is shown press Tab.
- Change showmenu=no to showmenu=yes.
- Change netmask=255.255.255.0 to netmask=255.255.0.0.
- Press Enter.
-
-4 Wait until screen Fuel setup . is shown.
- Note: This takes about 30 minutes.
-
-5. Select PXE Setup and change the following fields to appropriate values (example below):
- Static Pool Start 10.20.0.3
- Static Pool End 10.20.0.254
- DHCP Pool Start 10.20.128.3
- DHCP Pool End 10.20.128.254
-
-6. Select DNS & Hostname and change the following fields to appropriate values:
- Hostname <CEE Region name>-fuel
- Domain <Domain Name>
- Search Domain <Search Domain Name>
- Hostname to test DNS <Hostname to test DNS>
-
-7. Select Time Sync and change the following fields to appropriate values:
- NTP Server 1 <Customer NTP server 1>
- NTP Server 2 <Customer NTP server 2>
- NTP Server 3<Customer NTP server 3>
- Note: This step is only to pass the network test, the actual ntp parameters will be set with the pre_deply script.
-
-8. Start the installation.
- Select Quit Setup and press Save and Quit.
- Installation starts, wait until a screen with logon credentials is shown.
- Note: This takes about 15 minutes.
-
-10. Enable PXE Booting and put it first in the bios boot order menu.
-
-11. Reboot the controller- and compute blades.
-
-12. Connect to Fuel wit a browser towards port 8000
-
-13. Create and name a new OpenStack environment, to be installed.
-
-14. Select Icehouse on Ubuntu . in field OpenStack Release.
-
-15. Select deployment mode.
- Select the Multi-node with HA.
-
-16. Select compute node mode.
- Select KVM as hypervisor.
-
-17. Select network mode.
- Select Neutron with VLAN segmentation.
-
-18. Select Storage Backends.
- Select Ceph for Cinder and default for glance.
-
-
-19. Select additional services.
- Check option Install Celiometer (OpenStack Telemetry).
-
-20. Create the new environment.
-
-21. Wait for availability nodes.
- Wait until all nodes are displayed in top right in <total number of server> TOTAL NODES and <total number of servers> UNALLOCATED NODES.
-
-22. Open the created environment.
-
-23. Open the networks tab.
-
-24. Update the public configuration.
- Change the following fields to appropriate values:
- IP Range Start to <Public IP Address start>
- IP Range End to <Public IP Address end>
- CIDR to <CIDR for Public IP Addresses>
- Gateway to <Gateway for Public IP Addresses>
- Check VLAN tagging.
- Set appropriate VLAN id.
-
-25. Update the management configuration.
- Set CIDR to 172.16.255.128/25.
- Check VLAN tagging.
- Set appropriate VLAN id.
-
-26. Update the storage configuration.
- Set CIDR to the appropriate value
- Check VLAN tagging.
- Set appropriate VLAN id.
-
-27. Update the Neutron L2 configuration.
- Set VLAN ID range.
-
-28. Update the Neutron L3 configuration.
- Set Internal network CIDR to an appropriate value
- Set Internal network gateway to an appropriate value
- Set Floating IP ranges.
- Set DNS Servers
-
-29. Save Settings.
-
-30. Click "verify network" to check the network set-up
-
-31. Update storage configuration.
-
-32. Open the nodes tab.
-
-33. Assign roles.
- Check Controller and Telemetry . MongoDB.
- Check three nodes to be installed as Controller in pane Assign Role.
- Click Apply Changes.
- Check Compute.
- Check nodes to be installed as Compute nodes in pane Assign Role.
- Click Apply Changes.
-
-34. Configure interfaces.
- Check Select All to select all nodes with Control, Telemetry . MongoDB and Compute node roles.
- Click Configure Interfaces.
- Screen Configure interfaces on number of <number of nodes> nodes is shown.
- Assign interfaces (bonded) for mgmt-, admin-, private-, public- and storage networks
-
-35. Run the pre-deploy script.
- Log on as root to the Fuel node.
- Print Fuel environment Id (fuel env)
- #> id | status | name | mode | release_id | changes <id>| new | <CEE Region name>| ha_compact | 2 | <ite specific information>
-
-36. Run the pre-deployment script (/opt/opnfv/pre-deploy.sh <id>)
- As prompted for-, set the DNS servers to go into /etc/resolv.conf.
- As prompted for-, set any Hosts file additions for controllers and compute nodes. You will be prompted for name, FQDN and IP for each entry. Press return when prompted for a name when you have completed your input.
- As prompted for-, set NTP upstream configuration for controllers. You will be prompted for a NTP server each entry. Press return when prompted for a NTP server when you have completed your input.
-
-37. Deploy the environment.
- In the Fuel GUI, click Deploy Changes.
-
-38 Verify the OpenStack Environment
- Open the Health Check tab .
- Select Select All.
- Click Run tests.