diff options
Diffstat (limited to 'foreman')
-rwxr-xr-x | foreman/ci/deploy.sh | 68 |
1 files changed, 68 insertions, 0 deletions
diff --git a/foreman/ci/deploy.sh b/foreman/ci/deploy.sh index 5746e10..5216c48 100755 --- a/foreman/ci/deploy.sh +++ b/foreman/ci/deploy.sh @@ -1121,11 +1121,79 @@ start_virtual_nodes() { fi } +##check to make sure nodes are powered off +##this function does nothing if virtual +##params: none +##usage: check_baremetal_nodes() +check_baremetal_nodes() { + if [ $virtual ]; then + echo "${blue}Skipping Baremetal node power status check as deployment is virtual ${reset}" + else + echo "${blue}Checking Baremetal nodes power state... ${reset}" + if [ ! -z "$base_config" ]; then + # Install ipmitool + # Major version is pinned to force some consistency for Arno + if ! yum list installed | grep -i ipmitool; then + echo "${blue}Installing ipmitool...${reset}" + if ! yum -y install ipmitool-1*; then + echo "${red}Failed to install ipmitool!${reset}" + exit 1 + fi + fi + + ###find all the bmc IPs and number of nodes + node_counter=0 + output=`grep bmc_ip $base_config | grep -Eo '[0-9]+.[0-9]+.[0-9]+.[0-9]+'` + for line in ${output} ; do + bmc_ip[$node_counter]=$line + ((node_counter++)) + done + + max_nodes=$((node_counter-1)) + + ###find bmc_users per node + node_counter=0 + output=`grep bmc_user $base_config | sed 's/\s*bmc_user:\s*//'` + for line in ${output} ; do + bmc_user[$node_counter]=$line + ((node_counter++)) + done + + ###find bmc_pass per node + node_counter=0 + output=`grep bmc_pass $base_config | sed 's/\s*bmc_pass:\s*//'` + for line in ${output} ; do + bmc_pass[$node_counter]=$line + ((node_counter++)) + done + + for mynode in `seq 0 $max_nodes`; do + echo "${blue}Node: ${bmc_ip[$mynode]} ${bmc_user[$mynode]} ${bmc_pass[$mynode]} ${reset}" + ipmi_output=`ipmitool -I lanplus -P ${bmc_pass[$mynode]} -U ${bmc_user[$mynode]} -H ${bmc_ip[$mynode]} chassis status \ + | grep "System Power" | cut -d ':' -f2 | tr -d [:blank:]` + if [ "$ipmi_output" == "on" ]; then + echo "${red}Error: Node is powered on: ${bmc_ip[$mynode]} ${reset}" + echo "${red}Please run clean.sh before running deploy! ${reset}" + exit 1 + elif [ "$ipmi_output" == "off" ]; then + echo "${blue}Node: ${bmc_ip[$mynode]} is powered off${reset}" + else + echo "${red}Warning: Unable to detect node power state: ${bmc_ip[$mynode]} ${reset}" + fi + done + else + echo "${red}base_config was not provided for a baremetal install! Exiting${reset}" + exit 1 + fi + fi +} + ##END FUNCTIONS main() { parse_cmdline "$@" disable_selinux + check_baremetal_nodes install_EPEL install_vbox install_ansible |