diff options
author | Jaume Devesa <devvesa@gmail.com> | 2016-01-20 14:07:28 +0000 |
---|---|---|
committer | Jaume Devesa <devvesa@gmail.com> | 2016-01-20 15:11:03 +0100 |
commit | 9d13f73a75e5a7a21bab3db8d7191ff1a66c8f5d (patch) | |
tree | f0bd08b49047e406aec80e9de9cef627f6ee862b /network/config | |
parent | a2300bc50e4675bbd6d892d40dd14221ebbf0c5d (diff) |
Create linux bridge vlans environments
Define environments to create VLANs attached to a single physical nic as
'single-nic-vlans' does, but using linux_bridge instead of ovs_bridge
Change-Id: I8c6fe9ec7028178f783e7d9c0a1cc67a1517eb3d
Diffstat (limited to 'network/config')
6 files changed, 626 insertions, 0 deletions
diff --git a/network/config/single-nic-linux-bridge-vlans/README.md b/network/config/single-nic-linux-bridge-vlans/README.md new file mode 100644 index 00000000..b7ded049 --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/README.md @@ -0,0 +1,19 @@ +This directory contains Heat templates to help configure +Vlans on a single NICs for each Overcloud role. + +Configuration +------------- + +To make use of these templates create a Heat environment that looks +something like this: + + resource\_registry: + OS::TripleO::BlockStorage::Net::SoftwareConfig: network/config/single-nic-linux-bridge-vlans/cinder-storage.yaml + OS::TripleO::Compute::Net::SoftwareConfig: network/config/single-nic-linux-bridge-vlans/compute.yaml + OS::TripleO::Controller::Net::SoftwareConfig: network/config/single-nic-linux-bridge-vlans/controller.yaml + OS::TripleO::ObjectStorage::Net::SoftwareConfig: network/config/single-nic-linux-bridge-vlans/swift-storage.yaml + OS::TripleO::CephStorage::Net::SoftwareConfig: network/config/single-nic-linux-bridge-vlans/ceph-storage.yaml + +Or use this Heat environment file: + + environments/net-single-nic-linux-bridge-with-vlans.yaml diff --git a/network/config/single-nic-linux-bridge-vlans/ceph-storage.yaml b/network/config/single-nic-linux-bridge-vlans/ceph-storage.yaml new file mode 100644 index 00000000..a46d7e20 --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/ceph-storage.yaml @@ -0,0 +1,106 @@ +heat_template_version: 2015-04-30 + +description: > + Software Config to drive os-net-config to configure VLANs for the + ceph storage role. + +parameters: + ControlPlaneIp: + default: '' + description: IP address/subnet on the ctlplane network + type: string + ExternalIpSubnet: + default: '' + description: IP address/subnet on the external network + type: string + InternalApiIpSubnet: + default: '' + description: IP address/subnet on the internal API network + type: string + StorageIpSubnet: + default: '' + description: IP address/subnet on the storage network + type: string + StorageMgmtIpSubnet: + default: '' + description: IP address/subnet on the storage mgmt network + type: string + TenantIpSubnet: + default: '' + description: IP address/subnet on the tenant network + type: string + StorageNetworkVlanID: + default: 30 + description: Vlan ID for the storage network traffic. + type: number + StorageMgmtNetworkVlanID: + default: 40 + description: Vlan ID for the storage mgmt network traffic. + type: number + ControlPlaneSubnetCidr: # Override this via parameter_defaults + default: '24' + description: The subnet CIDR of the control plane network. + type: string + ControlPlaneDefaultRoute: # Override this via parameter_defaults + description: The default route of the control plane network. + type: string + DnsServers: # Override this via parameter_defaults + default: [] + description: A list of DNS servers (2 max for some implementations) that will be added to resolv.conf. + type: comma_delimited_list + EC2MetadataIp: # Override this via parameter_defaults + description: The IP address of the EC2 metadata server. + type: string + +resources: + OsNetConfigImpl: + type: OS::Heat::StructuredConfig + properties: + group: os-apply-config + config: + os_net_config: + network_config: + - + type: linux_bridge + name: br-storage + use_dhcp: false + dns_servers: {get_param: DnsServers} + addresses: + - + ip_netmask: + list_join: + - '/' + - - {get_param: ControlPlaneIp} + - {get_param: ControlPlaneSubnetCidr} + routes: + - + ip_netmask: 169.254.169.254/32 + next_hop: {get_param: EC2MetadataIp} + - + default: true + next_hop: {get_param: ControlPlaneDefaultRoute} + members: + - + type: interface + name: nic1 + # force the MAC address of the bridge to this interface + primary: true + - + type: vlan + vlan_id: {get_param: StorageNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageMgmtNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageMgmtIpSubnet} + +outputs: + OS::stack_id: + description: The OsNetConfigImpl resource. + value: {get_resource: OsNetConfigImpl} diff --git a/network/config/single-nic-linux-bridge-vlans/cinder-storage.yaml b/network/config/single-nic-linux-bridge-vlans/cinder-storage.yaml new file mode 100644 index 00000000..08613a3b --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/cinder-storage.yaml @@ -0,0 +1,117 @@ +heat_template_version: 2015-04-30 + +description: > + Software Config to drive os-net-config to configure VLANs for the + cinder storage role. + +parameters: + ControlPlaneIp: + default: '' + description: IP address/subnet on the ctlplane network + type: string + ExternalIpSubnet: + default: '' + description: IP address/subnet on the external network + type: string + InternalApiIpSubnet: + default: '' + description: IP address/subnet on the internal API network + type: string + StorageIpSubnet: + default: '' + description: IP address/subnet on the storage network + type: string + StorageMgmtIpSubnet: + default: '' + description: IP address/subnet on the storage mgmt network + type: string + TenantIpSubnet: + default: '' + description: IP address/subnet on the tenant network + type: string + InternalApiNetworkVlanID: + default: 20 + description: Vlan ID for the internal_api network traffic. + type: number + StorageNetworkVlanID: + default: 30 + description: Vlan ID for the storage network traffic. + type: number + StorageMgmtNetworkVlanID: + default: 40 + description: Vlan ID for the storage mgmt network traffic. + type: number + ControlPlaneSubnetCidr: # Override this via parameter_defaults + default: '24' + description: The subnet CIDR of the control plane network. + type: string + ControlPlaneDefaultRoute: # Override this via parameter_defaults + description: The default route of the control plane network. + type: string + DnsServers: # Override this via parameter_defaults + default: [] + description: A list of DNS servers (2 max for some implementations) that will be added to resolv.conf. + type: comma_delimited_list + EC2MetadataIp: # Override this via parameter_defaults + description: The IP address of the EC2 metadata server. + type: string + +resources: + OsNetConfigImpl: + type: OS::Heat::StructuredConfig + properties: + group: os-apply-config + config: + os_net_config: + network_config: + - + type: linux_bridge + name: br-storage + use_dhcp: false + dns_servers: {get_param: DnsServers} + addresses: + - + ip_netmask: + list_join: + - '/' + - - {get_param: ControlPlaneIp} + - {get_param: ControlPlaneSubnetCidr} + routes: + - + ip_netmask: 169.254.169.254/32 + next_hop: {get_param: EC2MetadataIp} + - + default: true + next_hop: {get_param: ControlPlaneDefaultRoute} + members: + - + type: interface + name: nic1 + # force the MAC address of the bridge to this interface + primary: true + - + type: vlan + vlan_id: {get_param: InternalApiNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: InternalApiIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageMgmtNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageMgmtIpSubnet} + +outputs: + OS::stack_id: + description: The OsNetConfigImpl resource. + value: {get_resource: OsNetConfigImpl} diff --git a/network/config/single-nic-linux-bridge-vlans/compute.yaml b/network/config/single-nic-linux-bridge-vlans/compute.yaml new file mode 100644 index 00000000..b6522c67 --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/compute.yaml @@ -0,0 +1,118 @@ +heat_template_version: 2015-04-30 + +description: > + Software Config to drive os-net-config to configure VLANs for the + compute role. + +parameters: + ControlPlaneIp: + default: '' + description: IP address/subnet on the ctlplane network + type: string + ExternalIpSubnet: + default: '' + description: IP address/subnet on the external network + type: string + InternalApiIpSubnet: + default: '' + description: IP address/subnet on the internal API network + type: string + StorageIpSubnet: + default: '' + description: IP address/subnet on the storage network + type: string + StorageMgmtIpSubnet: + default: '' + description: IP address/subnet on the storage mgmt network + type: string + TenantIpSubnet: + default: '' + description: IP address/subnet on the tenant network + type: string + InternalApiNetworkVlanID: + default: 20 + description: Vlan ID for the internal_api network traffic. + type: number + StorageNetworkVlanID: + default: 30 + description: Vlan ID for the storage network traffic. + type: number + TenantNetworkVlanID: + default: 50 + description: Vlan ID for the tenant network traffic. + type: number + ControlPlaneSubnetCidr: # Override this via parameter_defaults + default: '24' + description: The subnet CIDR of the control plane network. + type: string + ControlPlaneDefaultRoute: # Override this via parameter_defaults + description: The default route of the control plane network. + type: string + DnsServers: # Override this via parameter_defaults + default: [] + description: A list of DNS servers (2 max for some implementations) that will be added to resolv.conf. + type: comma_delimited_list + EC2MetadataIp: # Override this via parameter_defaults + description: The IP address of the EC2 metadata server. + type: string + +resources: + OsNetConfigImpl: + type: OS::Heat::StructuredConfig + properties: + group: os-apply-config + config: + os_net_config: + network_config: + - + type: linux_bridge + name: {get_input: bridge_name} + use_dhcp: false + dns_servers: {get_param: DnsServers} + addresses: + - + ip_netmask: + list_join: + - '/' + - - {get_param: ControlPlaneIp} + - {get_param: ControlPlaneSubnetCidr} + routes: + - + ip_netmask: 169.254.169.254/32 + next_hop: {get_param: EC2MetadataIp} + - + ip_netmask: 0.0.0.0/0 + default: true + next_hop: {get_param: ControlPlaneDefaultRoute} + members: + - + type: interface + name: {get_input: interface_name} + # force the MAC address of the bridge to this interface + primary: true + - + type: vlan + vlan_id: {get_param: InternalApiNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: InternalApiIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: StorageIpSubnet} + - + type: vlan + vlan_id: {get_param: TenantNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: TenantIpSubnet} + +outputs: + OS::stack_id: + description: The OsNetConfigImpl resource. + value: {get_resource: OsNetConfigImpl} diff --git a/network/config/single-nic-linux-bridge-vlans/controller.yaml b/network/config/single-nic-linux-bridge-vlans/controller.yaml new file mode 100644 index 00000000..72105481 --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/controller.yaml @@ -0,0 +1,149 @@ +heat_template_version: 2015-04-30 + +description: > + Software Config to drive os-net-config to configure VLANs for the + controller role. + +parameters: + ControlPlaneIp: + default: '' + description: IP address/subnet on the ctlplane network + type: string + ExternalIpSubnet: + default: '' + description: IP address/subnet on the external network + type: string + InternalApiIpSubnet: + default: '' + description: IP address/subnet on the internal API network + type: string + StorageIpSubnet: + default: '' + description: IP address/subnet on the storage network + type: string + StorageMgmtIpSubnet: + default: '' + description: IP address/subnet on the storage mgmt network + type: string + TenantIpSubnet: + default: '' + description: IP address/subnet on the tenant network + type: string + ExternalNetworkVlanID: + default: 10 + description: Vlan ID for the external network traffic. + type: number + InternalApiNetworkVlanID: + default: 20 + description: Vlan ID for the internal_api network traffic. + type: number + StorageNetworkVlanID: + default: 30 + description: Vlan ID for the storage network traffic. + type: number + StorageMgmtNetworkVlanID: + default: 40 + description: Vlan ID for the storage mgmt network traffic. + type: number + TenantNetworkVlanID: + default: 50 + description: Vlan ID for the tenant network traffic. + type: number + ExternalInterfaceDefaultRoute: + default: '10.0.0.1' + description: default route for the external network + type: string + ControlPlaneSubnetCidr: # Override this via parameter_defaults + default: '24' + description: The subnet CIDR of the control plane network. + type: string + DnsServers: # Override this via parameter_defaults + default: [] + description: A list of DNS servers (2 max for some implementations) that will be added to resolv.conf. + type: comma_delimited_list + EC2MetadataIp: # Override this via parameter_defaults + description: The IP address of the EC2 metadata server. + type: string + ControlPlaneDefaultRoute: # Override this via parameter_defaults + description: The default route of the control plane network. + type: string + +resources: + OsNetConfigImpl: + type: OS::Heat::StructuredConfig + properties: + group: os-apply-config + config: + os_net_config: + network_config: + - + type: linux_bridge + name: {get_input: bridge_name} + use_dhcp: false + dns_servers: {get_param: DnsServers} + addresses: + - + ip_netmask: + list_join: + - '/' + - - {get_param: ControlPlaneIp} + - {get_param: ControlPlaneSubnetCidr} + routes: + - + ip_netmask: 169.254.169.254/32 + next_hop: {get_param: EC2MetadataIp} + - + ip_netmask: 0.0.0.0/0 + default: true + next_hop: {get_param: ControlPlaneDefaultRoute} + members: + - + type: interface + name: {get_input: interface_name} + # force the MAC address of the bridge to this interface + primary: true + - + type: vlan + vlan_id: {get_param: ExternalNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: ExternalIpSubnet} + routes: + - + ip_netmask: 0.0.0.0/0 + default: true + next_hop: {get_param: ExternalInterfaceDefaultRoute} + - + type: vlan + vlan_id: {get_param: InternalApiNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: InternalApiIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: StorageIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageMgmtNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: StorageMgmtIpSubnet} + - + type: vlan + vlan_id: {get_param: TenantNetworkVlanID} + device: {get_input: bridge_name} + addresses: + - + ip_netmask: {get_param: TenantIpSubnet} + +outputs: + OS::stack_id: + description: The OsNetConfigImpl resource. + value: {get_resource: OsNetConfigImpl} diff --git a/network/config/single-nic-linux-bridge-vlans/swift-storage.yaml b/network/config/single-nic-linux-bridge-vlans/swift-storage.yaml new file mode 100644 index 00000000..962b9890 --- /dev/null +++ b/network/config/single-nic-linux-bridge-vlans/swift-storage.yaml @@ -0,0 +1,117 @@ +heat_template_version: 2015-04-30 + +description: > + Software Config to drive os-net-config to configure VLANs for the + swift storage role. + +parameters: + ControlPlaneIp: + default: '' + description: IP address/subnet on the ctlplane network + type: string + ExternalIpSubnet: + default: '' + description: IP address/subnet on the external network + type: string + InternalApiIpSubnet: + default: '' + description: IP address/subnet on the internal API network + type: string + StorageIpSubnet: + default: '' + description: IP address/subnet on the storage network + type: string + StorageMgmtIpSubnet: + default: '' + description: IP address/subnet on the storage mgmt network + type: string + TenantIpSubnet: + default: '' + description: IP address/subnet on the tenant network + type: string + InternalApiNetworkVlanID: + default: 20 + description: Vlan ID for the internal_api network traffic. + type: number + StorageNetworkVlanID: + default: 30 + description: Vlan ID for the storage network traffic. + type: number + StorageMgmtNetworkVlanID: + default: 40 + description: Vlan ID for the storage mgmt network traffic. + type: number + ControlPlaneSubnetCidr: # Override this via parameter_defaults + default: '24' + description: The subnet CIDR of the control plane network. + type: string + ControlPlaneDefaultRoute: # Override this via parameter_defaults + description: The default route of the control plane network. + type: string + DnsServers: # Override this via parameter_defaults + default: [] + description: A list of DNS servers (2 max for some implementations) that will be added to resolv.conf. + type: comma_delimited_list + EC2MetadataIp: # Override this via parameter_defaults + description: The IP address of the EC2 metadata server. + type: string + +resources: + OsNetConfigImpl: + type: OS::Heat::StructuredConfig + properties: + group: os-apply-config + config: + os_net_config: + network_config: + - + type: linux_bridge + name: br-storage + use_dhcp: false + dns_servers: {get_param: DnsServers} + addresses: + - + ip_netmask: + list_join: + - '/' + - - {get_param: ControlPlaneIp} + - {get_param: ControlPlaneSubnetCidr} + routes: + - + ip_netmask: 169.254.169.254/32 + next_hop: {get_param: EC2MetadataIp} + - + default: true + next_hop: {get_param: ControlPlaneDefaultRoute} + members: + - + type: interface + name: nic1 + # force the MAC address of the bridge to this interface + primary: true + - + type: vlan + vlan_id: {get_param: InternalApiNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: InternalApiIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageIpSubnet} + - + type: vlan + vlan_id: {get_param: StorageMgmtNetworkVlanID} + device: br-storage + addresses: + - + ip_netmask: {get_param: StorageMgmtIpSubnet} + +outputs: + OS::stack_id: + description: The OsNetConfigImpl resource. + value: {get_resource: OsNetConfigImpl} |