blob: 48462b80bf037e350375a48a6f91614248433408 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
|
#!/bin/bash
##############################################################################
# Copyright (c) 2015 Ericsson AB and others.
#
# All rights reserved. This program and the accompanying materials
# are made available under the terms of the Apache License, Version 2.0
# which accompanies this distribution, and is available at
# http://www.apache.org/licenses/LICENSE-2.0
##############################################################################
# yardstick-img-modify - download and modify a Ubuntu cloud image
#
# The actual customization is done by a script passed with an absolute path as
# the only single argument. The command needs to be invoked as sudo
#
# Example invocation:
# yardstick-img-modify /home/yardstick/tools/ubuntu-server-cloudimg-modify.sh
#
# Warning: the script will create files by default in:
# /tmp/workspace/yardstick
# the files will be owned by root!
#
# TODO: image resize is needed if the base image is too small
#
set -e
die() {
echo "error: $1" >&2
exit 1
}
test $# -eq 1 || die "no image specific script as argument"
test $(id -u) -eq 0 || die "should invoke using sudo"
cmd=$1
test -x $cmd
mountdir="/mnt/yardstick"
workspace=${WORKSPACE:-"/tmp/workspace/yardstick"}
host=${HOST:-"cloud-images.ubuntu.com"}
release=${RELEASE:-"trusty"}
image_path="${release}/current/${release}-server-cloudimg-amd64-disk1.img"
image_url=${IMAGE_URL:-"https://${host}/${image_path}"}
md5sums_path="${release}/current/MD5SUMS"
md5sums_url=${MD5SUMS_URL:-"https://${host}/${md5sums_path}"}
imgfile="${workspace}/yardstick-${release}-server.img"
raw_imgfile="${workspace}/yardstick-${release}-server.raw"
filename=$(basename $image_url)
# download and checksum base image, conditionally if local copy is outdated
download() {
test -d $workspace || mkdir -p $workspace
cd $workspace
rm -f MD5SUMS # always download the checksum file to a detect stale image
wget $md5sums_url
test -e $filename || wget -nc $image_url
grep $filename MD5SUMS | md5sum -c ||
if [ $? -ne 0 ]; then
rm $filename
wget -nc $image_url
grep $filename MD5SUMS | md5sum -c
fi
qemu-img convert $filename $raw_imgfile
cd -
}
# mount image
setup() {
mkdir -p $mountdir
for i in $(seq 0 9); do
[ -a /dev/loop$i ] || mknod -m 660 /dev/loop$i b 7 $i
done
loopdevice=$(kpartx -l $raw_imgfile | head -1 | cut -f1 -d ' ')
kpartx -a $raw_imgfile
mount /dev/mapper/$loopdevice $mountdir
cp $cmd $mountdir/$(basename $cmd)
}
# modify image running a script using in a chrooted environment
modify() {
# resolv.conf does not exist in base image, pass nameserver value from host
nameserver_ip=$(grep -m 1 '^nameserver' \
/etc/resolv.conf | awk '{ print $2 '})
chroot $mountdir /$(basename $cmd) $nameserver_ip
umount $mountdir
qemu-img convert -c -o compat=0.10 -O qcow2 $raw_imgfile $imgfile
}
# cleanup (umount) the image
cleanup() {
# designed to be idempotent
mount | grep $mountdir && umount $mountdir
if [ -f $raw_imgfile ]; then
kpartx -d $raw_imgfile || true
fi
rm -f $raw_imgfile
rm -rf $mountdir
}
set -x
main() {
cleanup
download
setup
modify
cleanup
echo "the modified image is found here: $imgfile"
}
main
|