Age | Commit message (Collapse) | Author | Files | Lines |
|
JIRA: YARDSTICK-1105
Running a vPE test ends up with up to 25% drooped packets.
This is due to tolerated loss being incorrectly configured,
test duration was too short and test interval was too
short.
Note This is due to the fact that vPE use case have by
default a tolerated loss of 100%, Now changed to 0.001,
same as L2FWD
Also: Grafan dashboard has been updated to show all SUT
CPUS Utilization in 1 panel. And LINE rate MIN, MAX & TEST
Rate have been added
Change-Id: I7adae2199b3f656fe460705b6aeb3aa69c767d50
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
|
|
JIRA: YARDSTICK-1221
In order to increase accuracy of result the following are done :-
- Improve Measurement Accuracy (YARDSTICK-1212)
- Improve Sampling Interval (YARDSTICK-1219)
- Allow 4 PROX ports to be read simultaneously (YARDSTICK-1220)
This change does the following :-
- Stores LINE Rate statistics of Sample
- Requires a confirmation retry before deciding to increase or
decrease this is configurable.
- Allows the user to disable Sampling or specify a sample interval
- Added Code Coverage of ProxDurationRunner based on YARDSTICK-1199
Change-Id: I27242ac1849c9a2712866385b5fbc05977c71516
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
The uplink and downlink interfaces for the 4 port
test cases were inconsistent and fixed in this commit.
This affects all the 4 port PROX test cases.
Tested on: Heat L2fwd-4 and L3fwd-4 test case.
JIRA: YARDSTICK-1185
Change-Id: Ia2ce7ed0dc395b812f84ede94e259b42dc833579
Signed-off-by:Abhijit Sinha <abhijit.sinha@intel.com>
|
|
|
|
JIRA: YARDSTICK-1211
Change-Id: I0899d470ca5a0ec7d42d36a9ff9c39cc7369310c
Signed-off-by: Xavier Simonart <xavier.simonart@intel.com>
|
|
|
|
Add PROX and vFW scale out TCs with availability zone
configuration. To be able to specify the availability
zone for specific VNF or TG the following example of
command line option shoud be used:
yardstick -d task start --task-args='{
"num_vnfs": 2, "availability_zone":
{
"vnf_0": "az_0", "tg_0": "az_0",
"vnf_1": "az_1", "tg_1": "az_1",
... }}' <SCALE-OUT-TC-FILE>
The steps to run new scale-out TCs is documented in the
userguide.
JIRA: YARDSTICK-1203
Change-Id: Ib3878485c5483981fe9b48ab02995712bcc31ae5
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
The Prox L2-fwd test case has a bad packet, which fails
the test case to run in OpenStack context as it's dropped
by the neutron.
This fix is needed to successfully run the L2fwd 2 and
4 port test cases in heat based test cases.
Change-Id: I86df31a6df1eaa6f968e46af159ac6a0157f402c
JIRA: YARDSTICK-1164
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
|
|
JIRA: YARDSTICK-1037
NSB PROX L3FWD was incorrect. The routing table (ipv4.lua) was incorrect.
Also a specific ipv4 for 2 port configuration is required.
Change-Id: I3a5fd1ea1d1ddf74cbdd6a5d9e7ced42d3c1d6e9
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
JIRA: YARDSTICK-1035
Do not hardcode NIC/interface speed in PROX test. Test assumes
NIC used is 10Gbps. This is incorrect. It could support 1Gbps,
10Gbps, 25Gbps, 40Gbps or something else.
This is used to calculate pps (Packets Per Second)
In Baremetal the NIC speed could be extracted. however when
run on a virtual machine this is not possible.
Solution:
Add in options section of test file.
eg.
Options:
interface_speed_gbps: 10
Where 10 refers to a 10Gbps. In a setup where multiple interfaces
are used. This will refer to the speed of the slowest connection.
Change-Id: I89ab16479a2cdd1d79e52cbcc5a972762c60d057
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
These scale-up TCs replace PROX static TCs which will be removed
by separate commit once those new TCs are merged.
Change-Id: I892a81c4bfd199782fb561faccc11e70a49675ae
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
JIRA: YARDSTICK-1036
This stores a number of extra counters in influxdb for Prox test cases.
It also stores existing counters with a "succcess_" tag.
Previously throughput where stored without success or failure indication.
Also "Result_" counters are also stored.
These can now be used by Grafana to graph output.
Change-Id: Ie5636c14ecbab1b53a988bdfbd47ddd1fcdbd695
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
The "context:file" of tc_prox_baremetal_lw_aftr
has an incorrect path, compaired to all other
prox test cases.
Change-Id: Id24e74905f36bc84fdf93d1a2966211ecad55c8b
Signed-off-by: Xavier Simonart <xavier.simonart@intel.com>
|
|
JIRA: YARDSTICK-1003
- There are redundant files for Prox vnf descriptors
tg and vnf for 1, 2 and 4 port set-up.
- We can use one vnf descriptor file per prox tg and prox vnf,
reducing the number of redundant files.
- Tested on Prox BM L2fwd 2 and 4 port test case.
Change-Id: I4c61fd11725121f19392443460ac2ad39c934e2d
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
JIRA: YARDSTICK-965
Removed the redundant files and directory from
Prox test folder.
Change-Id: I6167f0a4ccdd581153dad3ec9f5eaaf2619aacbd
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
YARDSTICK-839
In a scale-up test the VNF number can start from
0 to MAX (num_vnf-1)
The NSB PROX BM test nodes are currently marked as:
tg__0: trafficgen_1.yardstick
vnf__0: vnf.yardstick
They need to be changed to the below:
tg__0: tg_0.yardstick
vnf__0: vnf_0.yardstick
Changes done are:
- All BM Prox test cases have tg_0 and vnf_0 as default
test nodes
- The prox-baremetal-1/2/4.yaml sample pod file
- Cleaned Up some unused Prox test/config files
Change-Id: I819011bcb35eda62b17dd3e1035918918c582b13
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
|
|
Changed Copyright notice on tuples.lua from "Intel Copyright" to Apache 2.0
Change-Id: I85e6f9eb86c116d552f86cddf05b3b368b32f776
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
JIRA: YARDSTICK-802
Addition of PROX LW_AFTR basked on PROX/DATS v037 test_104_lw_aftr.py
- This support BM and Openstack Heat
- This supports 4 Ports ONLY
- Grafana Dashboards included
- Code Coverage / Unit testing
Change-Id: If2170ab458bf687256d5f1a1e840a3b9d2788ef7
Signed-off-by: Daniel MArtin Buckley <daniel.m.buckley@intel.com>
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
As per defect:
- the "context:" stanza of every tc_prox_baremetal*.yaml"
file has an incorrect pathname for the config file
- tc_prox_baremetal_binsearch.yaml and
tc_prox_baremetal_ramp.yaml refer to
"prox-baremetal.yml", which idoes not exist
- incorrect prox bin path
Resolution:
- Unify the pod file name and path for all BM tests
- Prox bin path changed to "/opt/nsb_bin/prox"
Change-Id: I16b25189104ad5585ddc1c2c0dd71b3c4c2aecd3
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
JIRA: YARDSTICK-802
Generator was incorrectly configured to generated traffic for p0, p1 (twice), and p3
Should be p0, p1, p2 and p3
Change-Id: Ib62a3c6523b1eda635b8c727c36e140fd480003e
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
JIRA: YARDSTICK-802
Addition of Prox vPE test case
- The tests supports BM, Openstack Heat
- Supports 4 ports
- Grafana dashboards included
- Added support for parameters.lua
for prox additional files
- Unit tests for code coverage
Change-Id: I5cccb351dacba88a293ae4b8aba1f0a803d62e6d
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
Signed-off-by: Daniel MArtin Buckley <daniel.m.buckley@intel.com>
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
JIRA: YARDSTICK-802
Updated the handle config for l3fwd 2 port test
The tx and rx descripters is removed as they
were not there in original DATS config.
The BM test was dropping packets beacuse of this.
Change-Id: I40d113267cbb3376a772b5a5aaecf74bea9d06fb
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
Change-Id: Iff39fa5b90d1ae5534ce1fff31dfb84c1e47340c
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
JIRA: YARDSTICK-802
Added Prox BNG and BNG-QoS Test
- The tests supports BM, Openstack Heat
- Supports 4 ports
- Test added for BNG traffic profile
- Fixed the Prox heat test cases with
proper upstream and downstream links
- Grafana Dashboard for BNG & BNG-QoS added
- Increased the test Duration to 300
TODO:
- Test does not Terminate correctly
Update:
Added new helper class for run_test: Genric, MPLS
and BNG tests.
Change-Id: Ib40811bedb45a3c3030643943f32679a4044e076
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
Signed-off-by: Edward MacGillivray <edward.s.macgillivray@intel.com>
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
Since we increased the images size the 4G is not sufficient anymore.
Change-Id: Iae25cf4cfb7a6cc69c8d28771c183a2342ac38d0
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
JIRA: YARDSTICK-802
Addition of PROX L2FWD_Multiflow, ACL, Load Balancing plus
grafana dashboards
Supports 2 and 4 port Baremetal & Heat
Change-Id: I1f3990d5451de265ee3901302569c355ece3b146
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
Change-Id: I85afff4582bf538fcd0be5b4db1405a4da2573f9
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Also rename private to uplink, public to downlink
for scale-out template we need to count from 0
so we can use range() without +1/-1 errors
vnf_0, vnf_1
tg_0, tg_1
also fix Ixia defaults
Change-Id: I6aecfbb95f99af20f012a9df19c19be77d1b5b77
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Edward MacGillivray <edward.s.macgillivray@intel.com>
|
|
JIRA: YARDSTICK-802
Added Prox L3FWD and Packet buffering tests
- The tests supports BM and Openstack Heat
- L3FWD tests suports 2 and 4 ports
- Packet flow buffering test is a 1 port test
- Grafana Dashboards are added
TODO: Latency stats are missing in KPI collection
Need to invetigate that
Coverage if needed!
Change-Id: I216a170488d5578622cf8c3748a6277b380f016a
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
JIRA: YARDSTICK-802
Addition of Prox L2Fwd, MPLS test cases for BM and Heat.
updates:
Most of tg_prox and prox_vnf were absorbed into the base classes.
delete most of ProxDpdkVnfSetupEnvHelper, it is handled by DpdkVnfSetupEnvHelper baseclass
use standard _build_pipeline_kwargs methods
don't use terminate() use baseclass version
add new method kill_vnf that runs pkill -x
replace resource_helper.execute() with vnf_execture for dumping stats
In order to share code between tg_prox and vnf_prox
refactor to have tg_prox hold and wrap a ProxApproxVnf instance and call
methods on that class. Do this instead of multiple-inheritance.
Implement ProxApproxVnf.terminate() using prox socket command
based exit, (stop_all, quit, force_quit).
vnf_execute calls resource_helper.execute() which calls
socket methods on the sut object.
Since tg_prox wraps the VNF object, we can call
terminate on the VNF object and it should work correctly.
move prox config generation to parent process
we need to get core number info from config file
inside the TG processes, so we need to generate
the config in the parent process so the data is
copied to the child during the fork.
moved more config file methods to the setup_helper class.
we run force_quit after quit, so the socket should already be closed
this will trigger socket error, so add _ignore_errors option for
vnf_execute to ignore socket errors
Fixed the terminate issue. Added MPLS tests.
Added TG Stats in_packet/out_packet
Fixed compile (pep8) issues
Fixed MPLS TG port stats, in/out packets
Added Grafana dashboards for L2FWD and MPLS
Traffic profiles modified for tolerated loss and
precision as per DATS tests.
Added unit test case for Mpls
Single port test stats collection support.
Change-Id: Idd9493f597c668a3bb7d90e167e6a418546106e8
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
PROX was added to samplevnf project
https://git.opnfv.org/samplevnf/tree/VNFs/DPPD-PROX
JIRA: YARDSTICK-638
Change-Id: If9875b1130c6bed87deb8720b0d8b28ede9289d9
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|