Age | Commit message (Collapse) | Author | Files | Lines |
|
JIRA: YARDSTICK-1404
The test scripts require an extra argument to support collectd.
Also the CPU utilization is a different variable name structure
in the JSON file.
Change-Id: I127b7e86c0f93f7743331a2d71eb81d690e42471
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
JIRA: YARDSTICK-1101
The traffic generated by the generator in bng-4 result in
non-symmetrical use of the cores on the SUT, as a whole
range of IP addresses is skipped.
Update cpe0 and cpe1 in gen files.
In addition, for the routing table (ipv4.lua) for the BNG
should be slighly different: while the BNG is a 4 ports
test, only 2 of the ports are used as outgoing routing
ports (the inet ports). Hence, the routing table should
only use the mac of those two ports. The bad configuration
(using 4 ports) result in an issue when BNG SUT and GEN
are connected through a switch, packets are sent by the
BNG SUT through the INET interfaces, but sometimes with
the MAC of the CPE interface...
Hence, packets are received on the wrong interface on the
Gen site (resulting in some interfaces, the CPE ones,
being overloaded)
Created ipv4_bng.lua and remove mac 0 and 2
Change-Id: I97019f0415d2f58d50ec855d04800eb705f41541
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
JIRA: YARDSTICK-1101
Problem was incorrect generator and changed the traffic profile to allow
a tolerated loss of 5%.
ARP packets are not managed (just passed thru the system) therefor the
tolerated loss must be higehr than normal.
Change-Id: I03bd62b397a66b50961e810d033c6894d0b3e9a6
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
The uplink and downlink interfaces for the 4 port
test cases were inconsistent and fixed in this commit.
This affects all the 4 port PROX test cases.
Tested on: Heat L2fwd-4 and L3fwd-4 test case.
JIRA: YARDSTICK-1185
Change-Id: Ia2ce7ed0dc395b812f84ede94e259b42dc833579
Signed-off-by:Abhijit Sinha <abhijit.sinha@intel.com>
|
|
As per defect:
- the "context:" stanza of every tc_prox_baremetal*.yaml"
file has an incorrect pathname for the config file
- tc_prox_baremetal_binsearch.yaml and
tc_prox_baremetal_ramp.yaml refer to
"prox-baremetal.yml", which idoes not exist
- incorrect prox bin path
Resolution:
- Unify the pod file name and path for all BM tests
- Prox bin path changed to "/opt/nsb_bin/prox"
Change-Id: I16b25189104ad5585ddc1c2c0dd71b3c4c2aecd3
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
JIRA: YARDSTICK-802
Added Prox BNG and BNG-QoS Test
- The tests supports BM, Openstack Heat
- Supports 4 ports
- Test added for BNG traffic profile
- Fixed the Prox heat test cases with
proper upstream and downstream links
- Grafana Dashboard for BNG & BNG-QoS added
- Increased the test Duration to 300
TODO:
- Test does not Terminate correctly
Update:
Added new helper class for run_test: Genric, MPLS
and BNG tests.
Change-Id: Ib40811bedb45a3c3030643943f32679a4044e076
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
Signed-off-by: Edward MacGillivray <edward.s.macgillivray@intel.com>
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|