Age | Commit message (Collapse) | Author | Files | Lines |
|
intel_pmu needs to download a config file based on the
CPU model. When generating VNF images we don't have
access to the actual vCPU that will be used, so we
can't predownload. This code was meant to be a fix
for that by downloading all the configs and then
selecting one that matched the vCPU.
However we have license issues with intel_pmu enven GPLv2 code,
so remove it for now.
Change-Id: I5257ff7c4ddc1d40537dadb29efa40d1d68cb852
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I6bd8a87f70954f288975e3e73e3cfbd36ae561dc
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
|
|
use anonymous flavors
force num_vnfs to int
added provider network examples
we have to disable port security for provider networks
removed vld_id, not needed
adjust num_vfs to allocate two physnets per VNF.
fix for multiports
Change-Id: Ic4c8314dc07f6295b9559188989d81058bb48eb0
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
To fully enable IxLoad, after installing the IXIA client,
check /opt/ixia/ixload/<ver>/bin/ixloadpython and make sure
you can run this cmd inside the yardstick container. Usually
user is required to copy or link /opt/ixia/python/<ver>/bin/ixiapython
to /usr/bin/ixiapython<ver>.
Change-Id: I6bc633802ad6c70329581014ec89c75bb7f8d688
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
While creating the mirror for pmu event list generation, some of
the links would fail, throwing error. This fixes that.
Change-Id: I52e96b1a6eacb5a9611845e815ecff9052df168a
Signed-off-by: Dhaval Patel <dhaval.r.patel@intel.com>
|
|
|
|
- trex
- ixia
- ixia correlated
Change-Id: I7d1414227c27c2bb03454eac94592e07c434f070
Signed-off-by: Deepak S <deepak.s@linux.intel.com>
|
|
Change-Id: I3d1a491e4c0f0554a861d9bb24fbd0ac94835759
Signed-off-by: Deepak S <deepak.s@linux.intel.com>
|
|
|
|
switch from hardcoded path to dynamic path
based on bin_path
also enable proxy for install_collectd
add barometer settings for virt and ovs_stats
Change-Id: Id138aef548332a3e3fcb3963b746e7c9f10c0948
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Bumping collectd version to include pmu plugin enablement,
bounding pmu-tools and intel_cmt_cat to a commit-id
Change-Id: I666d52c5574cec0caebb07535332984fa77e5b65
Signed-off-by: Dhaval Patel <dhaval.r.patel@intel.com>
|
|
for collectd KPIs we need may need to open 10,000+ files
one file for each core * number of CPU counters we read.
Use the ansible pam_limits moules to increase the nofile
setting. This should allow the VNF to boot with increased
number of files open
Change-Id: I46b75d5ca59e8e359c985a1e37daaee89897884c
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Added review dependency, removed collectd commit-id
replicating bash script, added pmu roles to playbook
Create local mirror for event list generation, copy script
to image, and run event list generation at runtime if
intel_pmu is enabled.
Change-Id: Ie46a2b197f4d2037cf3eed194764ce9eb5670415
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
added download_civetweb and install_civetweb roles.
Change-Id: Id4f60cc07b3befc7edb3cfc38773fe1a73a44c1f
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
libyajl needed for ovs_events and ovs_stats, removed installing
from src and rather installing as deb pkg
Change-Id: Ic1ebf88304bbc7f4fa7b9b51c95f1e8e729e71e3
Signed-off-by: Dhaval Patel <dhaval.r.patel@intel.com>
|
|
|
|
|
|
|
|
This is required for influxdb results being reported
"in the future" when the timezones do not match.
Change-Id: Ic41e19d26c46b6ccfa6dacddb595236af19e437a
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
Change-Id: I2755b596068545c1a3a672ceff47d814a44ae050
Signed-off-by: Deepak S <deepak.s@linux.intel.com>
|
|
Change-Id: I7da2d5bcd7c58c669e28a7271e4c6848c003e84a
Signed-off-by: Deepak S <deepak.s@linux.intel.com>
|
|
2 - node setup:
- Traffic generator starts new stream on both uplink and downlink
This patch addes amsible scripts to enable scale_out testcases
- vfw
Change-Id: I0340636bce3e74cd6175f728b9e7e014a4eb2fd5
Signed-off-by: Deepak S <deepak.s@linux.intel.com>
|
|
|
|
|
|
Change-Id: Ia7c1ce781075142910a6c618a9a23f34a710dfe9
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I8529f33d849fc659b557e1d19761c0765ebda57e
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
Change-Id: I0305c263740c25bdfa3bb2667838ca2b75d33ba0
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
required DPDK fixes to enable building collectd with dpdkstats
need /usr/lib/dpdk-pmd symlinks
Compiling all this code requies more space than the default ubuntu
cloud-image, so we need to resize the cloud image somehow
Change-Id: Ib39fc94ba8101ca1aebc7d2a710be88b0338f7c3
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
OpenStack.
Change-Id: Iad1dce6b0d0a1c010aa62f2fdf54c5d0560ed0c7
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
when building the image in chroot we can't run
update-grub of grub-mkconfig because both commands
probe for root partitions, which doesn't work
in the chroot.
Instead we manually regexp replace the kernel boot
line in /boot/**/grub*.cfg
Change-Id: I31fac2a3db4d1d044f11357b1715119066509676
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
container.
Change-Id: I21204ddf97e2cccc2d5a762f5d910068bda1a948
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
- we need to make sure we have lsof installed
- we need to update cache inside the image, because we are unable to install some of them
Change-Id: Ic555489779e9096540001cb9c62ea2ab25c1ae90
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
Change-Id: Ief1cfd7c018948a9125549400bb5bf0e5c20d730
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
|
|
re-enable retries
Change-Id: I77738250e8aa8de3c8a8a1019093af04ce785ae0
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
when clause is re-evaluated after default
Change-Id: I2f9b093a4cb0e2d024f8d6beb935f336ac1df637
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I71fdef5deff75cad434bf19f0a7e507c1dcc4ed3
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
When compiling Trex, DPDK, collectd and all the SampleVNFs
we use more than the 2.2GB size of the original Ubuntu cloud image.
Accordingly we need to resize the image.
If we were not inside a docker container we would use virt-resize
to automatically handle all the cases, but virt-resize launches qemu.
Instead we can use qemu-img to add extra space, then
luckily we can use parted to resize the partition and finally
resize2fs to resize the filesystem.
This limits us to only ext3/4 images, but if we need to
we could add support for other filesystems by checking
file system type.
Change-Id: Iac84b8e6967af5be64c280a7b1eaaf09f5d6b3aa
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I5865cd50d5fde26e9e9fc265d4385372d668413f
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I5e8d1461e158c0b499a8864099fbb218965a429f
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
image build code.
Change-Id: Id711d6fdacaddeafb8550290503d6cb6c814ea70
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
|
|
Change-Id: I4f29f584395d58b2fcece1ca8fcbda78a64e3a66
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
|
|
we now clone samplevnf from git repo
made install_samplevnf role that takes as parameter VNF name
added ubuntu_server_cloudimg_modify_samplevnfs playbook
Change-Id: I5724e3b844b3137542a5c293516893a5c80f5c61
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Change-Id: I3639ab84ab5b9e802e1bbd23674b0fbda46fdc66
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|