Age | Commit message (Collapse) | Author | Files | Lines |
|
|
|
|
|
|
|
Added IP random range `seed` configuration option into IXIA
traffic profile.
JIRA: YARDSTICK-1364
Change-Id: Ic050b6cc48ea75ac6d0470bf7ec1b188649811e1
Signed-off-by: Sosyak, Myronx <myronx.sosyak@intel.com>
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
JIRA: YARDSTICK-1101
The traffic generated by the generator in bng-4 result in
non-symmetrical use of the cores on the SUT, as a whole
range of IP addresses is skipped.
Update cpe0 and cpe1 in gen files.
In addition, for the routing table (ipv4.lua) for the BNG
should be slighly different: while the BNG is a 4 ports
test, only 2 of the ports are used as outgoing routing
ports (the inet ports). Hence, the routing table should
only use the mac of those two ports. The bad configuration
(using 4 ports) result in an issue when BNG SUT and GEN
are connected through a switch, packets are sent by the
BNG SUT through the INET interfaces, but sometimes with
the MAC of the CPE interface...
Hence, packets are received on the wrong interface on the
Gen site (resulting in some interfaces, the CPE ones,
being overloaded)
Created ipv4_bng.lua and remove mac 0 and 2
Change-Id: I97019f0415d2f58d50ec855d04800eb705f41541
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
- Implemented handling of UDP source and destination ports from
IXIA traffic profile.
- UDP ports can be defined as a single value or as a random range.
Ports range is configured with two parameters 'fixed_bits' and
'mask_bits'.
- For example '8-48' range definition will create a repeatable
pattern of four values that fall within the range of 8 and 56.
JIRA: YARDSTICK-1363
Change-Id: I0ace722f6be843ea79c3d3f4de22cb8fa5669d4f
Signed-off-by: Myron Sosyak <myronx.sosyak@intel.com>
Signed-off-by: Pshyk Serhiy <serhiyx.pshyk@intel.com>
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
|
|
|
|
AutoConnectSSH execute method always returns exception when remote
command returns non 0 ret code. This behavior has been introduced
by https://gerrit.opnfv.org/gerrit/#/c/58579/ changes which break
the NSB functionality. There are 200+ places where return code
(event non zoro) is expected to be returned by
AutoConnectSSH.execute() method. Right now the method returns
always exception in case of remote command return not zero which
causes the problem.
Changed execute() method to have previous behavior (raise_on_error
is always False by default) and the exception is raised only in
case if raise_on_error=True is set explicitly.
Added UT.
JIRA: YARDSTICK-1365
Change-Id: Ib067583ea5eb704b9174084b45b920c24eb307ac
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
Separate out test_parse_to_value_exception(self)
into 3 different methods:
test_parse_scanner(self)
test_parse_parser(self)
test_parse_reader(self)
This ensures that each side effect is tested, even if one fails.
JIRA: YARDSTICK-940
Change-Id: Ifdc84284c633fe1ddc1acf9cd985c5144030b430
Signed-off-by: John O Loughlin <john.oloughlin@intel.com>
|
|
Starting with the Openstack Queens release,
hw_firmware_type=uefi is implied on AArch64 by default
Using virtio-video, now default in nova, should be used
instead of VGA
JIRA: ARMBAND-388
Change-Id: If52206e2a2f0a05bde5632c91de9367fffdc2eb3
Signed-off-by: Delia Popescu <delia.popescu@enea.com>
|
|
The class PipelineRules uses assert statements to check the correctness
of an input parameter IP address. This commit will modify these lines
to use a dedicated function "common.utils.make_ipv4_address".
JIRA: YARDSTICK-966
Change-Id: I1c4cc439a7716d36548125c87dfb0bc200714a56
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
Currently the aarch64 yardstick image doesn't build because phantomsj and bower
don't install properly. Temporarily disable gui for aarch64 only so we can
still get the other updates.
JIRA: ARMBAND-391
Change-Id: I64f892641c7bdb1cb3a65b210f71b093878b1688
Signed-off-by: Cristina Pauna <cristina.pauna@enea.com>
|
|
yardstick.common.utils get_port_mac and get_port_ip both raise a
RuntimeError on positive remote command exit status. This commit fixes
them to use the error raising mechanism in yardstick.ssh.SSH.
Additionally, the class AutoConnectSSH class needed an additional
argument to allow the raising mechanism to work correctly.
JIRA: YARDSTICK-1240
Change-Id: Idad125ebbd668cef10a6149eb3e601a437a8d40d
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Improve test execution
* Use common functionality in setUp()
* Disable logging
* Remove tests that test common/utils code. These tests are moved to
common/utils's unit tests in a follow-up patch.
JIRA: YARDSTICK-1239
Change-Id: I88d047fe25c4c13bea446c9fc9bda92306420296
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Instead of using assert statements, raise a custom exception.
* Modify the unit tests so that they do not test unused parameters for
equality.
* Fix pylint and pep8 errors.
JIRA: YARDSTICK-966
Change-Id: I41e13a5a22086827792eaf9de8da2e4ed6dd42de
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
|
|
|
|
|
|
|
|
|
|
YARDSTICK-1222 has made attacker recover only when the sla not pass.
But for baremetal down test case, the node need to power on even the sla pass.
TODO:
Make attacker can support mandatory recover in some situation.
JIRA: YARDSTICK-1337
Change-Id: Ib567b9b9025e5ee421ea47140c468537ad16f090
Signed-off-by: rexlee8776 <limingjiang@huawei.com>
|
|
* Improve test execution
* Use common functionality in setUp()
* Disable logging
JIRA: YARDSTICK-1238
Change-Id: I0904bf99f0e151b437d506bf322da83f706dcf8f
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
This modification utilises a custom exception to be raised if an invalid
mac address is passed to the function "mac_address_to_hex_list".
JIRA: YARDSTICK-966
Change-Id: Ic2940276f500e9710c54963a445a137e73bd6b25
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
Change-Id: Iad8e8397f4ef339f70c6eef80ef58b1b045ef3fa
Signed-off-by: Emma Foley <emma.l.foley@intel.com>
|
|
* Remove unneeded variables
* Do not raise RuntimeError when a remote command fails, instead
leave it for the yardstick ssh module to handle.
* Prevent CsvReader from raising StopIteration if csv output cannot be
parsed. The SLA validation will take care of errors in that case.
JIRA: YARDSTICK-1166
Change-Id: I9e353d39dfd3bd27407dde32744ce71b5762e84e
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Remove unneeded variables
* Do not raise RuntimeError when a remote command fails, instead leave
it for the yardstick ssh module to handle.
* Prevent CsvReader from raising StopIteration if csv output cannot be
parsed. The SLA validation will take care of errors in that case.
JIRA: YARDSTICK-1166
Change-Id: I6cf550bd7bc8f511b3c0f25c67f8caab18bccd28
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Use time.sleep to avoid multiprocessing.Queue broken pipe error.
JIRA: YARDSTICK-1245
Change-Id: I0176c062f44830804ddbeebeb012afc1f9e20d41
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Initial test: test ArithmeticRunner._run_benchmark called arguments
JIRA: YARDSTICK-1245
Change-Id: Id18c36bd1345052863ab777bf899c00fe66fd713
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Use time.sleep to avoid multiprocessing.Queue broken pipe error.
JIRA: YARDSTICK-1199
Change-Id: Icd35dad547bfa1ac4fab564c00628ef0d30ac338
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
* Use time.sleep to avoid multiprocessing.Queue broken pipe error.
* Use a real duration in one of the test cases to test that the worker
has successfully completed multiple iterations.
JIRA: YARDSTICK-1199
Change-Id: I0e14682d9993b69e2aa9fd9340a5a7620e9c0d8e
Signed-off-by: Miikka Koistinen <miikka.koistinen@nokia.com>
|
|
|
|
|
|
|
|
"util.wait_until_true" uses "util.Timer" to create an active wait for a
condition. "Timer" class uses "signal" to create a watchdog to track the
time lapsed.
When used out of the main thread, "Timer" raises the following error:
ValueError: signal only works in main thread
To make "util.wait_until_true" usable always, a new waitting method is
implemented.
JIRA: YARDSTICK-1358
Change-Id: Ifb5ba0b17b5beca0af5ceab4f6431d58b7928762
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
When correlated traffic TC is running, the traffic is
running only on uplink ports instead of both type of ports
(yardstick/network_services/traffic_profile/rfc2544.py +113).
Trex TG fails to get samples on downlink ports.
JIRA: YARDSTICK-1357
Change-Id: I66d78b73f2dc5bb531fe8607d0e46f60b828953e
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
JIRA: YARDSTICK-1196
Change-Id: I77b4772b9224ff5cd21fd9fc67eb7e4b821fcf77
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
JIRA: YARDSTICK-1318
Change-Id: I0c04bd2928d5a4166b483f0c4f9f75fa9e5e00d2
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
JIRA: YARDSTICK-1319
Change-Id: I8370c5ef4e43e58a8bb9c3aac60a089b0981dda0
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
|
|
When updating the IP packet in IxNextgen library, the IPv4 mask should
be defined in the following format: x.x.x.x
This mask defines the number of lower bits used to generate a random IP.
For example:
- mask length: 16
- mask string: 0.0.255.255
JIRA: YARDSTICK-1351
Change-Id: Ie3cbf0205aac83aea8d7f665bc068e8566238055
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
AclUknownActionTemplate -> AclUnknownActionTemplate
JIRA: YARDSTICK-1334
Change-Id: I796e080078c657c5e0e59144d24ec797e244a8f7
Signed-off-by: Emma Foley <emma.l.foley@intel.com>
|
|
* changes:
Add IP mask to IxNetwork configuration
Improve NetworkServiceTestCase._get_ip_flow_range() function
|
|
* changes:
Add pktgen test case base files
Add pktgen traffic profile
Add DPDK pktgen traffic generator
|
|
|
|
JIRA: YARDSTICK-1316
Change-Id: I792c873b42aba80be62ff7a93f6d02ea89e42356
Signed-off-by: Mytnyk, Volodymyr <volodymyrx.mytnyk@intel.com>
|
|
* changes:
Cleanup EnvironmentTestCase unit tests
Cleanup Testcase unit tests
|
|
|
|
Assign the IP mask to IxNetwork configuration, depending on the IP range
provided by the user in the traffic profile. In case of single IP, a
default mask will be provided:
- IP_VERSION_4_MASK = 24
- IP_VERSION_6_MASK = 64
JIRA: YARDSTICK-1351
Change-Id: I029473ab8b9966a76cf559ffef53b34ca11462ad
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
|