aboutsummaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
Diffstat (limited to 'docs')
-rw-r--r--docs/results/compass-os-nosdn-nofeature-ha.rst109
1 files changed, 102 insertions, 7 deletions
diff --git a/docs/results/compass-os-nosdn-nofeature-ha.rst b/docs/results/compass-os-nosdn-nofeature-ha.rst
index 3c3359bf5..bc75a2c10 100644
--- a/docs/results/compass-os-nosdn-nofeature-ha.rst
+++ b/docs/results/compass-os-nosdn-nofeature-ha.rst
@@ -14,25 +14,120 @@ Test Results for compass-os-nosdn-nofeature-ha
Details
=======
-.. after this doc is filled, remove all comments and include the scenario in
-.. results.rst by removing the comment on the file name.
-
+.. _Grafana: http://130.211.154.108/grafana/dashboard/db/yardstick-main
+.. _SC_POD: https://wiki.opnfv.org/pharos?&#community_test_labs
Overview of test results
------------------------
-.. general on metrics collected, number of iterations
+See Grafana_ for viewing test result metrics for each respective test case. It
+is possible to chose which specific scenarios to look at, and then to zoom in
+on the details of each run test scenario as well.
+
+All of the test case results below are based on 5 consecutive scenario test
+runs, each run on the Huawei SC_POD_ between February 13 and 18 in 2016. The
+best would be to have more runs to draw better conclusions from, but these are
+the only runs available at the time of OPNFV R2 release
+
+TC002
+-----
+The round-trip-time (RTT) between 2 VMs on different blades is measured using
+ping. The measurements are on average varying between 1.95 and 2.23 ms
+with a first 2 - 3.27 ms RTT spike in the beginning of each run (This could be
+because of normal ARP handling).SLA set to 10 ms. The SLA value is used as a
+reference, it has not been defined by OPNFV.
+
+TC005
+-----
+The IO read bandwidth look similar between different test runs, with an
+average at approx. 145-162 MB/s. Within each run the results vary much,
+minimum 2MB/s and maximum 712MB/s on the totality.
+SLA set to 400KB/s. The SLA value is used as a reference, it has not been
+defined by OPNFV.
+
+TC010
+-----
+The measurements for memory latency are consistent among test runs and results
+in approx. 1.2 ns. The variations between runs are similar, between
+1.215 and 1.278 ns. SLA set to 30 ns. The SLA value is used as
+a reference, it has not been defined by OPNFV.
+
+TC011
+-----
+For this scenario no results are available to report on. Probable reason is
+an integer/floating point issue regarding how InfluxDB is populated with
+result data from the test runs.
+
+TC012
+-----
+The average measurements for memory bandwidth are consistent among most of the
+different test runs at 12.98 - 16.73 GB/s. The last test run averages at
+16.67 GB/s. Within each run the results vary, with minimal BW of 16.59
+GB/s and maximum of 16.71 GB/s of the totality.
+SLA set to 15 GB/s. The SLA value is used as a reference, it has not been
+defined by OPNFV.
+
+TC014
+-----
+The Unixbench processor single and parallel speed scores show similar results
+at approx. 3000. The runs vary between scores 2499 and 3105.
+No SLA set.
+
+TC027
+-----
+The round-trip-time (RTT) between VM1 with ipv6 router on different blades is
+measured using ping6. The measurements are consistent at approx. 4 ms.
+SLA set to 30 ms.The SLA value is used as a reference, it has not been
+defined by OPNFV.
+
+TC037
+-----
+The amount of packets per second (PPS) and round trip times (RTT) between 2 VMs
+on different blades are measured when increasing the amount of UDP flows sent
+between the VMs using pktgen as packet generator tool.
+
+Round trip times and packet throughput between VMs are typically affected by
+the amount of flows set up and result in higher RTT and less PPS
+throughput.
+
+When running with less than 10000 flows the results are flat and consistent.
+RTT is then approx. 30 ms and the number of PPS remains flat at approx.
+230000 PPS. Beyond approx. 10000 flows and up to 1000000 (one million) there
+is an even drop in RTT and PPS performance, eventually ending up at approx.
+105-113 ms and 100000 PPS respectively.
+
+TC040
+-----
+test purpose is to verify the function of Yang-to-Tosca in Parse, and this test
+case is a weekly task, so it was triggered by manually, the result whether the
+output is same with expected outcome is success
+No SLA set.
Detailed test results
---------------------
-.. info on lab, installer, scenario
+The scenario was run on Huawei SC_POD_ with:
+Compass 1.0
+OpenStack Liberty
+OVS 2.4.0
+
+No SDN controller installed
Rationale for decisions
-----------------------
-.. result analysis, pass/fail
+Pass
+
+Tests were successfully executed and metrics collects (apart from TC011_).
+No SLA was verified. To be decided on in next release of OPNFV.
Conclusions and recommendations
-------------------------------
-.. did the expected behavior occured?
+The pktgen test configuration has a relatively large base effect on RTT in
+TC037 compared to TC002, where there is no background load at all (30 ms
+compared to 1 ms or less, which is more than a 3000 percentage different
+in RTT results). The larger amounts of flows in TC037 generate worse
+RTT results, in the magnitude of several hundreds of milliseconds. It would
+be interesting to also make and compare all these measurements to completely
+(optimized) bare metal machines running native Linux with all other relevant
+tools available, e.g. lmbench, pktgen etc.