aboutsummaryrefslogtreecommitdiffstats
path: root/docs/testing
diff options
context:
space:
mode:
Diffstat (limited to 'docs/testing')
-rwxr-xr-xdocs/testing/developer/devguide/devguide.rst10
-rwxr-xr-xdocs/testing/developer/devguide/devguide_nsb_prox.rst2
-rwxr-xr-xdocs/testing/user/userguide/01-introduction.rst6
-rw-r--r--docs/testing/user/userguide/04-installation.rst11
-rw-r--r--docs/testing/user/userguide/05-operation.rst2
-rw-r--r--docs/testing/user/userguide/08-grafana.rst2
-rw-r--r--docs/testing/user/userguide/09-api.rst2
-rw-r--r--docs/testing/user/userguide/12-nsb-overview.rst2
-rw-r--r--docs/testing/user/userguide/13-nsb-installation.rst104
-rw-r--r--docs/testing/user/userguide/14-nsb-operation.rst8
-rw-r--r--docs/testing/user/userguide/15-list-of-tcs.rst11
-rw-r--r--docs/testing/user/userguide/comp-intro.rst4
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc010.rst3
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc011.rst6
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc012.rst1
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc019.rst22
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc025.rst11
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc027.rst2
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc040.rst2
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc042.rst2
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc050.rst49
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc052.rst19
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc055.rst4
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc057.rst11
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc063.rst1
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc069.rst6
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc073.rst2
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc074.rst10
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc081.rst4
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc084.rst25
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc087.rst11
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc092.rst33
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc093.rst43
-rw-r--r--docs/testing/user/userguide/references.rst22
34 files changed, 251 insertions, 202 deletions
diff --git a/docs/testing/developer/devguide/devguide.rst b/docs/testing/developer/devguide/devguide.rst
index 4fe01c12b..76ed7c651 100755
--- a/docs/testing/developer/devguide/devguide.rst
+++ b/docs/testing/developer/devguide/devguide.rst
@@ -47,7 +47,7 @@ your field of interest is.
Where can I find some help to start?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-.. _`user guide`: http://artifacts.opnfv.org/yardstick/danube/1.0/docs/stesting_user_userguide/index.html
+.. _`user guide`: https://artifacts.opnfv.org/yardstick/docs/testing_user_userguide/index.html
.. _`wiki page`: https://wiki.opnfv.org/display/yardstick/
This guide is made for you. You can have a look at the `user guide`_.
@@ -401,7 +401,7 @@ Gerrit & JIRA introduction
++++++++++++++++++++++++++
.. _Gerrit: https://www.gerritcodereview.com/
-.. _`OPNFV Gerrit`: http://gerrit.opnfv.org/
+.. _`OPNFV Gerrit`: http://gerrit.opnfv.org/gerrit
.. _link: https://identity.linuxfoundation.org/
.. _JIRA: https://jira.opnfv.org/secure/Dashboard.jspa
@@ -485,7 +485,7 @@ Git repository::
JIRA: YARDSTICK-XXX
-.. _`this document`: http://chris.beams.io/posts/git-commit/
+.. _`this document`: https://chris.beams.io/posts/git-commit/
The message that is required for the commit should follow a specific set of
rules. This practice allows to standardize the description messages attached
@@ -510,8 +510,8 @@ Yardstick committers and contributors to review your codes.
:alt: Gerrit for code review
You can find a list Yardstick people
-`here <https://wiki.opnfv.org/display/yardstick/People>`_, or use the
-``yardstick-reviewers`` and ``yardstick-committers`` groups in gerrit.
+`here <https://wiki.opnfv.org/display/yardstick/Yardstick+People>`_, or use
+the ``yardstick-reviewers`` and ``yardstick-committers`` groups in gerrit.
Modify the code under review in Gerrit
++++++++++++++++++++++++++++++++++++++
diff --git a/docs/testing/developer/devguide/devguide_nsb_prox.rst b/docs/testing/developer/devguide/devguide_nsb_prox.rst
index 79990055a..582668bc5 100755
--- a/docs/testing/developer/devguide/devguide_nsb_prox.rst
+++ b/docs/testing/developer/devguide/devguide_nsb_prox.rst
@@ -15,7 +15,7 @@ Prerequisites
In order to integrate PROX tests into NSB, the following prerequisites are required.
-.. _`dpdk wiki page`: http://dpdk.org/
+.. _`dpdk wiki page`: https://www.dpdk.org/
.. _`yardstick wiki page`: https://wiki.opnfv.org/display/yardstick/
.. _`Prox documentation`: https://01.org/intel-data-plane-performance-demonstrators/documentation/prox-documentation
.. _`openstack wiki page`: https://wiki.openstack.org/wiki/Main_Page
diff --git a/docs/testing/user/userguide/01-introduction.rst b/docs/testing/user/userguide/01-introduction.rst
index 494b1ef3d..74e752d63 100755
--- a/docs/testing/user/userguide/01-introduction.rst
+++ b/docs/testing/user/userguide/01-introduction.rst
@@ -9,8 +9,8 @@ Introduction
**Welcome to Yardstick's documentation !**
-.. _Pharos: https://wiki.opnfv.org/pharos
-.. _Yardstick: https://wiki.opnfv.org/yardstick
+.. _Pharos: https://wiki.opnfv.org/display/pharos
+.. _Yardstick: https://wiki.opnfv.org/display/yardstick
.. _Presentation: https://wiki.opnfv.org/download/attachments/2925202/opnfv_summit_-_yardstick_project.pdf?version=1&modificationDate=1458848320000&api=v2
Yardstick_ is an OPNFV Project.
@@ -70,7 +70,7 @@ This document consists of the following chapters:
Yardstick - Network service benchmarking to test real world usecase for a
given VNF.
-* Chapter :doc:`13-nsb_installation` provides instructions to install
+* Chapter :doc:`13-nsb-installation` provides instructions to install
*Yardstick - Network Service Benchmarking (NSB) testing*.
* Chapter :doc:`14-nsb-operation` provides information on running *NSB*
diff --git a/docs/testing/user/userguide/04-installation.rst b/docs/testing/user/userguide/04-installation.rst
index d97078909..6b3259299 100644
--- a/docs/testing/user/userguide/04-installation.rst
+++ b/docs/testing/user/userguide/04-installation.rst
@@ -3,6 +3,17 @@
.. http://creativecommons.org/licenses/by/4.0
.. (c) OPNFV, Ericsson AB, Huawei Technologies Co.,Ltd and others.
+..
+ Convention for heading levels in Yardstick documentation:
+
+ ======= Heading 0 (reserved for the title in a document)
+ ------- Heading 1
+ ~~~~~~~ Heading 2
+ +++++++ Heading 3
+ ''''''' Heading 4
+
+ Avoid deeper levels because they do not render well.
+
======================
Yardstick Installation
======================
diff --git a/docs/testing/user/userguide/05-operation.rst b/docs/testing/user/userguide/05-operation.rst
index f390d1643..82539c97f 100644
--- a/docs/testing/user/userguide/05-operation.rst
+++ b/docs/testing/user/userguide/05-operation.rst
@@ -183,7 +183,7 @@ Combining these elements together, a sample Heat context config looks like:
.. literalinclude::
../../../../yardstick/tests/integration/dummy-scenario-heat-context.yaml
:start-after: ---
- :empahsise-lines: 14-
+ :emphasize-lines: 14-
Using exisiting HOT Templates
'''''''''''''''''''''''''''''
diff --git a/docs/testing/user/userguide/08-grafana.rst b/docs/testing/user/userguide/08-grafana.rst
index 29bc23a08..020a08a65 100644
--- a/docs/testing/user/userguide/08-grafana.rst
+++ b/docs/testing/user/userguide/08-grafana.rst
@@ -36,7 +36,7 @@ of TC002.
.. image:: images/TC002.png
:width: 800px
- :alt:TC002 dashboard
+ :alt: TC002 dashboard
For each test case dashboard. On the top left, we have a dashboard selection,
you can switch to different test cases using this pull-down menu.
diff --git a/docs/testing/user/userguide/09-api.rst b/docs/testing/user/userguide/09-api.rst
index f0ae3980b..1a896699b 100644
--- a/docs/testing/user/userguide/09-api.rst
+++ b/docs/testing/user/userguide/09-api.rst
@@ -433,7 +433,7 @@ Example::
/api/v2/yardstick/tasks/<task_id>
---------------------------------
+---------------------------------
Description: This API is used to do some work related to yardstick tasks. For Euphrates, it supports:
diff --git a/docs/testing/user/userguide/12-nsb-overview.rst b/docs/testing/user/userguide/12-nsb-overview.rst
index 71a5c1130..7b0d46804 100644
--- a/docs/testing/user/userguide/12-nsb-overview.rst
+++ b/docs/testing/user/userguide/12-nsb-overview.rst
@@ -10,7 +10,7 @@ Network Services Benchmarking (NSB)
Abstract
========
-.. _Yardstick: https://wiki.opnfv.org/yardstick
+.. _Yardstick: https://wiki.opnfv.org/display/yardstick
This chapter provides an overview of the NSB, a contribution to OPNFV
Yardstick_ from Intel.
diff --git a/docs/testing/user/userguide/13-nsb-installation.rst b/docs/testing/user/userguide/13-nsb-installation.rst
index 10debbd9c..973d56628 100644
--- a/docs/testing/user/userguide/13-nsb-installation.rst
+++ b/docs/testing/user/userguide/13-nsb-installation.rst
@@ -3,12 +3,23 @@
.. http://creativecommons.org/licenses/by/4.0
.. (c) OPNFV, 2016-2018 Intel Corporation.
+..
+ Convention for heading levels in Yardstick documentation:
+
+ ======= Heading 0 (reserved for the title in a document)
+ ------- Heading 1
+ ~~~~~~~ Heading 2
+ +++++++ Heading 3
+ ''''''' Heading 4
+
+ Avoid deeper levels because they do not render well.
+
=====================================
Yardstick - NSB Testing -Installation
=====================================
Abstract
-========
+--------
The Network Service Benchmarking (NSB) extends the yardstick framework to do
VNF characterization and benchmarking in three different execution
@@ -27,7 +38,7 @@ The steps needed to run Yardstick with NSB testing are:
Prerequisites
-=============
+-------------
Refer chapter Yardstick Installation for more information on yardstick
prerequisites
@@ -46,7 +57,7 @@ Several prerequisites are needed for Yardstick (VNF testing):
* intel-cmt-cat
Hardware & Software Ingredients
--------------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
SUT requirements:
@@ -85,7 +96,7 @@ Boot and BIOS settings:
Install Yardstick (NSB Testing)
-===============================
+-------------------------------
Download the source code and install Yardstick from it
@@ -172,8 +183,8 @@ Another way to execute an installation for a Bare-Metal or a Standalone context
is to use ansible script ``install.yaml``. Refer chapter :doc:`04-installation`
for more details.
-System Topology:
-================
+System Topology
+---------------
.. code-block:: console
@@ -188,10 +199,10 @@ System Topology:
Environment parameters and credentials
-======================================
+--------------------------------------
Config yardstick conf
----------------------
+~~~~~~~~~~~~~~~~~~~~~
If user did not run 'yardstick env influxdb' inside the container, which will
generate correct ``yardstick.conf``, then create the config file manually (run
@@ -222,11 +233,11 @@ Add trex_path, trex_client_lib and bin_path in 'nsb' section.
trex_client_lib=/opt/nsb_bin/trex_client/stl
Run Yardstick - Network Service Testcases
-=========================================
+-----------------------------------------
NS testing - using yardstick CLI
---------------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
See :doc:`04-installation`
@@ -239,13 +250,13 @@ NS testing - using yardstick CLI
yardstick --debug task start yardstick/samples/vnf_samples/nsut/<vnf>/<test case>
Network Service Benchmarking - Bare-Metal
-=========================================
+-----------------------------------------
Bare-Metal Config pod.yaml describing Topology
-----------------------------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Bare-Metal 2-Node setup
-^^^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++++
.. code-block:: console
+----------+ +----------+
@@ -258,7 +269,7 @@ Bare-Metal 2-Node setup
trafficgen_1 vnf
Bare-Metal 3-Node setup - Correlated Traffic
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++++++++++
.. code-block:: console
+----------+ +----------+ +------------+
@@ -273,7 +284,7 @@ Bare-Metal 3-Node setup - Correlated Traffic
Bare-Metal Config pod.yaml
---------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~
Before executing Yardstick test cases, make sure that pod.yaml reflects the
topology and update all the required fields.::
@@ -348,13 +359,13 @@ topology and update all the required fields.::
Network Service Benchmarking - Standalone Virtualization
-========================================================
+--------------------------------------------------------
SR-IOV
-------
+~~~~~~
SR-IOV Pre-requisites
-^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++
On Host, where VM is created:
a) Create and configure a bridge named ``br-int`` for VM to connect to external network.
@@ -425,10 +436,10 @@ On Host, where VM is created:
SR-IOV Config pod.yaml describing Topology
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++++++++
-SR-IOV 2-Node setup:
-^^^^^^^^^^^^^^^^^^^^
+SR-IOV 2-Node setup
++++++++++++++++++++
.. code-block:: console
+--------------------+
@@ -456,7 +467,7 @@ SR-IOV 2-Node setup:
SR-IOV 3-Node setup - Correlated Traffic
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++++++
.. code-block:: console
+--------------------+
@@ -492,7 +503,7 @@ topology and update all the required fields.
.. note:: Update all the required fields like ip, user, password, pcis, etc...
SR-IOV Config pod_trex.yaml
-^^^^^^^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++++++++
.. code-block:: YAML
@@ -521,7 +532,7 @@ SR-IOV Config pod_trex.yaml
local_mac: "00:00.00:00:00:02"
SR-IOV Config host_sriov.yaml
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++++++++++
.. code-block:: YAML
@@ -537,7 +548,7 @@ SR-IOV testcase update:
``<yardstick>/samples/vnf_samples/nsut/vfw/tc_sriov_rfc2544_ipv4_1rule_1flow_64B_trex.yaml``
Update "contexts" section
-"""""""""""""""""""""""""
+'''''''''''''''''''''''''
.. code-block:: YAML
@@ -582,10 +593,10 @@ Update "contexts" section
OVS-DPDK
---------
+~~~~~~~~
OVS-DPDK Pre-requisites
-^^^^^^^^^^^^^^^^^^^^^^^
+~~~~~~~~~~~~~~~~~~~~~~~
On Host, where VM is created:
a) Create and configure a bridge named ``br-int`` for VM to connect to external network.
@@ -659,11 +670,10 @@ On Host, where VM is created:
OVS-DPDK Config pod.yaml describing Topology
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++++++++++
OVS-DPDK 2-Node setup
-^^^^^^^^^^^^^^^^^^^^^
-
++++++++++++++++++++++
.. code-block:: console
@@ -693,7 +703,7 @@ OVS-DPDK 2-Node setup
OVS-DPDK 3-Node setup - Correlated Traffic
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++++++++
.. code-block:: console
@@ -733,7 +743,7 @@ topology and update all the required fields.
.. note:: Update all the required fields like ip, user, password, pcis, etc...
OVS-DPDK Config pod_trex.yaml
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++++++++++
.. code-block:: YAML
@@ -761,7 +771,7 @@ OVS-DPDK Config pod_trex.yaml
local_mac: "00:00.00:00:00:02"
OVS-DPDK Config host_ovs.yaml
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++++++++++
.. code-block:: YAML
@@ -777,7 +787,7 @@ ovs_dpdk testcase update:
``<yardstick>/samples/vnf_samples/nsut/vfw/tc_ovs_rfc2544_ipv4_1rule_1flow_64B_trex.yaml``
Update "contexts" section
-"""""""""""""""""""""""""
+'''''''''''''''''''''''''
.. code-block:: YAML
@@ -832,7 +842,7 @@ Update "contexts" section
Network Service Benchmarking - OpenStack with SR-IOV support
-============================================================
+------------------------------------------------------------
This section describes how to run a Sample VNF test case, using Heat context,
with SR-IOV. It also covers how to install OpenStack in Ubuntu 16.04, using
@@ -840,7 +850,7 @@ DevStack, with SR-IOV support.
Single node OpenStack setup with external TG
---------------------------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.. code-block:: console
@@ -871,7 +881,7 @@ Single node OpenStack setup with external TG
Host pre-configuration
-^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++
.. warning:: The following configuration requires sudo access to the system. Make
sure that your user have the access.
@@ -971,7 +981,7 @@ Setup SR-IOV ports on the host:
DevStack installation
-^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++
Use official `Devstack <https://docs.openstack.org/devstack/pike/>`_
documentation to install OpenStack on a host. Please note, that stable
@@ -993,7 +1003,7 @@ Start the devstack installation on a host.
TG host configuration
-^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++
Yardstick automatically install and configure Trex traffic generator on TG
host based on provided POD file (see below). Anyway, it's recommended to check
@@ -1002,7 +1012,7 @@ the manual at https://trex-tgn.cisco.com/trex/doc/trex_manual.html.
Run the Sample VNF test case
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++
There is an example of Sample VNF test case ready to be executed in an
OpenStack environment with SR-IOV support: ``samples/vnf_samples/nsut/vfw/
@@ -1027,7 +1037,7 @@ context using steps described in `NS testing - using yardstick CLI`_ section.
Multi node OpenStack TG and VNF setup (two nodes)
--------------------------------------------------
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.. code-block:: console
@@ -1058,14 +1068,14 @@ Multi node OpenStack TG and VNF setup (two nodes)
Controller/Compute pre-configuration
-^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++++++++++++++++
Pre-configuration of the controller and compute hosts are the same as
described in `Host pre-configuration`_ section. Follow the steps in the section.
DevStack configuration
-^^^^^^^^^^^^^^^^^^^^^^
+++++++++++++++++++++++
Use official `Devstack <https://docs.openstack.org/devstack/pike/>`_
documentation to install OpenStack on a host. Please note, that stable
@@ -1092,7 +1102,7 @@ Start the devstack installation on the controller and compute hosts.
Run the sample vFW TC
-^^^^^^^^^^^^^^^^^^^^^
++++++++++++++++++++++
Install yardstick using `Install Yardstick (NSB Testing)`_ steps for OpenStack
context.
@@ -1109,10 +1119,10 @@ and the following yardtick command line arguments:
Enabling other Traffic generator
-================================
+--------------------------------
IxLoad
-^^^^^^
+~~~~~~
1. Software needed: IxLoadAPI ``<IxLoadTclApi verson>Linux64.bin.tgz`` and
``<IxOS version>Linux64.bin.tar.gz`` (Download from ixia support site)
@@ -1153,7 +1163,7 @@ IxLoad
``<repo>/samples/vnf_samples/nsut/vfw/tc_baremetal_http_ixload_1b_Requests-65000_Concurrency.yaml``
IxNetwork
----------
+~~~~~~~~~
IxNetwork testcases use IxNetwork API Python Bindings module, which is
installed as part of the requirements of the project.
diff --git a/docs/testing/user/userguide/14-nsb-operation.rst b/docs/testing/user/userguide/14-nsb-operation.rst
index ac12b32a3..c96155804 100644
--- a/docs/testing/user/userguide/14-nsb-operation.rst
+++ b/docs/testing/user/userguide/14-nsb-operation.rst
@@ -256,7 +256,7 @@ to the VNF.
An example scale-up Heat testcase is:
-.. literalinclude:: /samples/vnf_samples/nsut/vfw/tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale-up.yaml
+.. literalinclude:: /../samples/vnf_samples/nsut/vfw/tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale-up.yaml
:language: yaml
This testcase template requires specifying the number of VCPUs, Memory and Ports.
@@ -271,7 +271,7 @@ In order to support ports scale-up, traffic and topology templates need to be us
A example topology template is:
-.. literalinclude:: /samples/vnf_samples/nsut/vfw/vfw-tg-topology-scale-up.yaml
+.. literalinclude:: /../samples/vnf_samples/nsut/vfw/vfw-tg-topology-scale-up.yaml
:language: yaml
This template has ``vports`` as an argument. To pass this argument it needs to
@@ -293,7 +293,7 @@ For example:
A example traffic profile template is:
-.. literalinclude:: /samples/vnf_samples/traffic_profiles/ipv4_throughput-scale-up.yaml
+.. literalinclude:: /../samples/vnf_samples/traffic_profiles/ipv4_throughput-scale-up.yaml
:language: yaml
There is an option to provide predefined config for SampleVNFs. Path to config
@@ -457,7 +457,7 @@ Sample test case file
4. Modify ``networks/phy_port`` accordingly to the baremetal setup.
5. Run test from:
-.. literalinclude:: /samples/vnf_samples/nsut/acl/tc_ovs_rfc2544_ipv4_1rule_1flow_64B_trex.yaml
+.. literalinclude:: /../samples/vnf_samples/nsut/acl/tc_ovs_rfc2544_ipv4_1rule_1flow_64B_trex.yaml
:language: yaml
Preparing test run of vEPC test case
diff --git a/docs/testing/user/userguide/15-list-of-tcs.rst b/docs/testing/user/userguide/15-list-of-tcs.rst
index 0efecebd1..2f0a87144 100644
--- a/docs/testing/user/userguide/15-list-of-tcs.rst
+++ b/docs/testing/user/userguide/15-list-of-tcs.rst
@@ -118,17 +118,6 @@ StorPerf
opnfv_yardstick_tc074.rst
-virtual Traffic Classifier
---------------------------
-
-.. toctree::
- :maxdepth: 1
-
- opnfv_yardstick_tc006.rst
- opnfv_yardstick_tc007.rst
- opnfv_yardstick_tc020.rst
- opnfv_yardstick_tc021.rst
-
Templates
=========
diff --git a/docs/testing/user/userguide/comp-intro.rst b/docs/testing/user/userguide/comp-intro.rst
index ad354b66d..bab6e60da 100644
--- a/docs/testing/user/userguide/comp-intro.rst
+++ b/docs/testing/user/userguide/comp-intro.rst
@@ -7,10 +7,10 @@
Yardstick
=========
-.. _Yardstick: https://wiki.opnfv.org/yardstick
+.. _Yardstick: https://wiki.opnfv.org/display/yardstick
.. _Presentation: https://wiki.opnfv.org/_media/opnfv_summit_-_yardstick_project.pdf
.. _NFV-TST001: https://docbox.etsi.org/ISG/NFV/Open/Drafts/TST001_-_Pre-deployment_Validation/
-.. _Yardsticktst: https://wiki.opnfv.org/_media/opnfv_summit_-_bridging_opnfv_and_etsi.pdf
+.. _Yardsticktst: http://events17.linuxfoundation.org/sites/events/files/slides/OPNFV%20Summit%20-%20bridging_opnfv_and_etsi.pdf
The project's goal is to verify infrastructure compliance, from the perspective
of a Virtual Network Function (VNF).
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc010.rst b/docs/testing/user/userguide/opnfv_yardstick_tc010.rst
index 202307de6..19cc80e30 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc010.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc010.rst
@@ -34,6 +34,7 @@ Yardstick Test Case Description TC010
| | |
| | Lmbench is a suite of operating system microbenchmarks. This |
| | test uses lat_mem_rd tool from that suite including: |
+| | |
| | * Context switching |
| | * Networking: connection establishment, pipe, TCP, UDP, and |
| | RPC hot potato |
@@ -55,7 +56,7 @@ Yardstick Test Case Description TC010
| | The benchmark runs as two nested loops. The outer loop is |
| | the stride size. The inner loop is the array size. For each |
| | array size, the benchmark creates a ring of pointers that |
-| | point backward one stride.Traversing the array is done by: |
+| | point backward one stride. Traversing the array is done by:: |
| | |
| | p = (char **)*p; |
| | |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc011.rst b/docs/testing/user/userguide/opnfv_yardstick_tc011.rst
index 48bdef497..cbb1db91f 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc011.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc011.rst
@@ -60,14 +60,14 @@ Yardstick Test Case Description TC011
| | |
| | * options: |
| | protocol: udp # The protocol used by iperf3 tools |
-| | bandwidth: 20m # It will send the given number of packets |
-| | without pausing |
+| | # Send the given number of packets without pausing: |
+| | bandwidth: 20m |
| | * runner: |
| | duration: 30 # Total test duration 30 seconds. |
| | |
| | * SLA (optional): |
| | jitter: 10 (ms) # The maximum amount of jitter that is |
-| | accepted. |
+| | accepted. |
| | |
+--------------+--------------------------------------------------------------+
|applicability | Test can be configured with different: |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc012.rst b/docs/testing/user/userguide/opnfv_yardstick_tc012.rst
index b56e829f5..2502f5d94 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc012.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc012.rst
@@ -34,6 +34,7 @@ Yardstick Test Case Description TC012
| | |
| | LMbench is a suite of operating system microbenchmarks. |
| | This test uses bw_mem tool from that suite including: |
+| | |
| | * Cached file read |
| | * Memory copy (bcopy) |
| | * Memory read |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc019.rst b/docs/testing/user/userguide/opnfv_yardstick_tc019.rst
index 8d79e011a..d27b201c5 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc019.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc019.rst
@@ -43,20 +43,24 @@ Yardstick Test Case Description TC019
| | |
+--------------+--------------------------------------------------------------+
|monitors | In this test case, two kinds of monitor are needed: |
+| | |
| | 1. the "openstack-cmd" monitor constantly request a specific |
| | Openstack command, which needs two parameters: |
-| | 1) monitor_type: which is used for finding the monitor class |
-| | and related scritps. It should be always set to |
-| | "openstack-cmd" for this monitor. |
-| | 2) command_name: which is the command name used for request |
+| | |
+| | 1. monitor_type: which is used for finding the monitor |
+| | class and related scritps. It should be always set to |
+| | "openstack-cmd" for this monitor. |
+| | 2. command_name: which is the command name used for |
+| | request |
| | |
| | 2. the "process" monitor check whether a process is running |
| | on a specific node, which needs three parameters: |
-| | 1) monitor_type: which used for finding the monitor class |
-| | and related scritps. It should be always set to "process" |
-| | for this monitor. |
-| | 2) process_name: which is the process name for monitor |
-| | 3) host: which is the name of the node runing the process |
+| | |
+| | 1. monitor_type: which used for finding the monitor class |
+| | and related scritps. It should be always set to |
+| | "process" for this monitor. |
+| | 2. process_name: which is the process name for monitor |
+| | 3. host: which is the name of the node runing the process |
| | |
| | e.g. |
| | monitor1: |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc025.rst b/docs/testing/user/userguide/opnfv_yardstick_tc025.rst
index 0e2e9a5f8..f3f9ea6bf 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc025.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc025.rst
@@ -39,12 +39,15 @@ Yardstick Test Case Description TC025
| | |
+--------------+--------------------------------------------------------------+
|monitors | In this test case, one kind of monitor are needed: |
+| | |
| | 1. the "openstack-cmd" monitor constantly request a specific |
| | Openstack command, which needs two parameters |
-| | 1) monitor_type: which is used for finding the monitor class |
-| | and related scritps. It should be always set to |
-| | "openstack-cmd" for this monitor. |
-| | 2) command_name: which is the command name used for request |
+| | |
+| | 1) monitor_type: which is used for finding the monitor |
+| | class and related scripts. It should be always set to |
+| | "openstack-cmd" for this monitor. |
+| | 2) command_name: which is the command name used for |
+| | request |
| | |
| | There are four instance of the "openstack-cmd" monitor: |
| | monitor1: |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc027.rst b/docs/testing/user/userguide/opnfv_yardstick_tc027.rst
index 125fd59fa..90790e2e3 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc027.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc027.rst
@@ -7,7 +7,7 @@
Yardstick Test Case Description TC027
*************************************
-.. _ipv6: https://wiki.opnfv.org/ipv6_opnfv_project
+.. _ipv6: https://wiki.opnfv.org/display/ipv6
+-----------------------------------------------------------------------------+
|IPv6 connectivity between nodes on the tenant network |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc040.rst b/docs/testing/user/userguide/opnfv_yardstick_tc040.rst
index d62fbf787..4c73c9677 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc040.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc040.rst
@@ -7,7 +7,7 @@
Yardstick Test Case Description TC040
*************************************
-.. _Parser: https://wiki.opnfv.org/parser
+.. _Parser: https://wiki.opnfv.org/display/parser
+-----------------------------------------------------------------------------+
|Verify Parser Yang-to-Tosca |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc042.rst b/docs/testing/user/userguide/opnfv_yardstick_tc042.rst
index a0c487c7b..23b98c8f4 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc042.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc042.rst
@@ -9,7 +9,7 @@ Yardstick Test Case Description TC042
.. _DPDK: http://dpdk.org/doc/guides/index.html
.. _Testpmd: http://dpdk.org/doc/guides/testpmd_app_ug/index.html
-.. _Pktgen-dpdk: http://pktgen.readthedocs.io/en/latest/index.html
+.. _Pktgen-dpdk: https://pktgen-dpdk.readthedocs.io/en/latest/index.html
+-----------------------------------------------------------------------------+
|Network Performance |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
index 82a491b72..7d01cb99a 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst
@@ -35,18 +35,18 @@ Yardstick Test Case Description TC050
| | 3) interface: the network interface to be turned off. |
| | |
| | The interface to be closed by the attacker can be set by the |
-| | variable of "{{ interface_name }}" |
+| | variable of "{{ interface_name }}":: |
| | |
-| | attackers: |
-| | - |
-| | fault_type: "general-attacker" |
-| | host: {{ attack_host }} |
-| | key: "close-br-public" |
-| | attack_key: "close-interface" |
-| | action_parameter: |
-| | interface: {{ interface_name }} |
-| | rollback_parameter: |
-| | interface: {{ interface_name }} |
+| | attackers: |
+| | - |
+| | fault_type: "general-attacker" |
+| | host: {{ attack_host }} |
+| | key: "close-br-public" |
+| | attack_key: "close-interface" |
+| | action_parameter: |
+| | interface: {{ interface_name }} |
+| | rollback_parameter: |
+| | interface: {{ interface_name }} |
| | |
+--------------+--------------------------------------------------------------+
|monitors | In this test case, the monitor named "openstack-cmd" is |
@@ -56,19 +56,20 @@ Yardstick Test Case Description TC050
| | "openstack-cmd" for this monitor. |
| | 2) command_name: which is the command name used for request |
| | |
-| | There are four instance of the "openstack-cmd" monitor: |
-| | monitor1: |
-| | - monitor_type: "openstack-cmd" |
-| | - command_name: "nova image-list" |
-| | monitor2: |
-| | - monitor_type: "openstack-cmd" |
-| | - command_name: "neutron router-list" |
-| | monitor3: |
-| | - monitor_type: "openstack-cmd" |
-| | - command_name: "heat stack-list" |
-| | monitor4: |
-| | - monitor_type: "openstack-cmd" |
-| | - command_name: "cinder list" |
+| | There are four instance of the "openstack-cmd" monitor:: |
+| | |
+| | monitor1: |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "nova image-list" |
+| | monitor2: |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "neutron router-list" |
+| | monitor3: |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "heat stack-list" |
+| | monitor4: |
+| | - monitor_type: "openstack-cmd" |
+| | - command_name: "cinder list" |
+--------------+--------------------------------------------------------------+
|metrics | In this test case, there is one metric: |
| | 1)service_outage_time: which indicates the maximum outage |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc052.rst b/docs/testing/user/userguide/opnfv_yardstick_tc052.rst
index 9514b6819..7f2be6e7d 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc052.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc052.rst
@@ -65,15 +65,16 @@ Yardstick Test Case Description TC052
| | |
| | In this case, the "operation" adds a flavor and the "result |
| | checker" checks whether ths flavor is created. Their |
-| | parameters show as follows: |
-| | operation: |
-| | -operation_type: "nova-create-flavor" |
-| | -action_parameter: |
-| | flavorconfig: "test-001 test-001 100 1 1" |
-| | result checker: |
-| | -checker_type: "check-flavor" |
-| | -expectedValue: "test-001" |
-| | -condition: "in" |
+| | parameters show as follows:: |
+| | |
+| | operation: |
+| | -operation_type: "nova-create-flavor" |
+| | -action_parameter: |
+| | flavorconfig: "test-001 test-001 100 1 1" |
+| | result checker: |
+| | -checker_type: "check-flavor" |
+| | -expectedValue: "test-001" |
+| | -condition: "in" |
+--------------+--------------------------------------------------------------+
|metrics | In this test case, there is one metric: |
| | 1)service_outage_time: which indicates the maximum outage |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc055.rst b/docs/testing/user/userguide/opnfv_yardstick_tc055.rst
index c861ca90c..25703d3fb 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc055.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc055.rst
@@ -7,7 +7,7 @@
Yardstick Test Case Description TC055
*************************************
-.. _/proc/cpuinfo: http://www.linfo.org/proc_cpuinfo.html
+.. _`/proc/cpuinfo`: http://www.linfo.org/proc_cpuinfo.html
+-----------------------------------------------------------------------------+
|Compute Capacity |
@@ -41,7 +41,7 @@ Yardstick Test Case Description TC055
| | capacity output. |
| | |
+--------------+--------------------------------------------------------------+
-|references | /proc/cpuinfo_ |
+|references | `/proc/cpuinfo`_ |
| | |
| | ETSI-NFV-TST001 |
| | |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc057.rst b/docs/testing/user/userguide/opnfv_yardstick_tc057.rst
index 1bb43c9e7..245a58e08 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc057.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc057.rst
@@ -49,12 +49,15 @@ Yardstick Test Case Description TC057
| | -host: node1 |
+--------------+--------------------------------------------------------------+
|monitors | In this test case, a kind of monitor is needed: |
+| | |
| | 1. the "openstack-cmd" monitor constantly request a specific |
| | Openstack command, which needs two parameters: |
-| | 1) monitor_type: which is used for finding the monitor class |
-| | and related scripts. It should be always set to |
-| | "openstack-cmd" for this monitor. |
-| | 2) command_name: which is the command name used for request |
+| | |
+| | 1. monitor_type: which is used for finding the monitor |
+| | class and related scripts. It should be always set to |
+| | "openstack-cmd" for this monitor. |
+| | 2. command_name: which is the command name used for |
+| | request |
| | |
| | In this case, the command_name of monitor1 should be |
| | services that are managed by the cluster manager. |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc063.rst b/docs/testing/user/userguide/opnfv_yardstick_tc063.rst
index a77653aa5..7b8ee06c7 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc063.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc063.rst
@@ -58,6 +58,7 @@ Yardstick Test Case Description TC063
| | * count: 15 - how many times to stat disk utilization |
| | type: int |
| | unit: na |
+| | |
| | There are default values for each above-mentioned option. |
| | Run in background with other test cases. |
| | |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc069.rst b/docs/testing/user/userguide/opnfv_yardstick_tc069.rst
index af0e64fbf..e1bfd5399 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc069.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc069.rst
@@ -9,9 +9,6 @@ Yardstick Test Case Description TC069
.. _RAMspeed: http://alasir.com/software/ramspeed/
-.. table::
- :class: longtable
-
+-----------------------------------------------------------------------------+
|Memory Bandwidth |
| |
@@ -41,7 +38,8 @@ Yardstick Test Case Description TC069
| | * SLA (optional): 7000 (MBps) min_bandwidth: The minimum |
| | amount of memory bandwidth that is accepted. |
| | * type_id: 1 - runs a specified benchmark |
-| | (by an ID number): |
+| | (by an ID number):: |
+| | |
| | 1 -- INTmark [writing] 4 -- FLOATmark [writing] |
| | 2 -- INTmark [reading] 5 -- FLOATmark [reading] |
| | 3 -- INTmem 6 -- FLOATmem |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc073.rst b/docs/testing/user/userguide/opnfv_yardstick_tc073.rst
index ad4526405..873c5c99e 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc073.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc073.rst
@@ -7,7 +7,7 @@
Yardstick Test Case Description TC073
*************************************
-.. _netperf: http://www.netperf.org/netperf/training/Netperf.html
+.. _netperf: https://hewlettpackard.github.io/netperf/
+-----------------------------------------------------------------------------+
|Throughput per NFVI node test |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc074.rst b/docs/testing/user/userguide/opnfv_yardstick_tc074.rst
index d6beeaff9..8d025eecf 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc074.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc074.rst
@@ -91,12 +91,15 @@ Yardstick Test Case Description TC074
| | * workload=[workload module] |
| | If not specified, the default is to run all workloads. The |
| | workload types are: |
+| | |
| | - rs: 100% Read, sequential data |
| | - ws: 100% Write, sequential data |
| | - rr: 100% Read, random access |
| | - wr: 100% Write, random access |
| | - rw: 70% Read / 30% write, random access |
+| | |
| | measurements. |
+| | |
| | * workloads={json maps} |
| | This parameter supercedes the workload and calls the V2.0 |
| | API in StorPerf. It allows for greater control of the |
@@ -131,11 +134,13 @@ Yardstick Test Case Description TC074
| | |
| | Storperf is required to be installed in the environment. |
| | There are two possible methods for Storperf installation: |
-| | Run container on Jump Host |
-| | Run container in a VM |
+| | |
+| | - Run container on Jump Host |
+| | - Run container in a VM |
| | |
| | Running StorPerf on Jump Host |
| | Requirements: |
+| | |
| | - Docker must be installed |
| | - Jump Host must have access to the OpenStack Controller |
| | API |
@@ -146,6 +151,7 @@ Yardstick Test Case Description TC074
| | |
| | Running StorPerf in a VM |
| | Requirements: |
+| | |
| | - VM has docker installed |
| | - VM has OpenStack Controller credentials and can |
| | communicate with the Controller API |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc081.rst b/docs/testing/user/userguide/opnfv_yardstick_tc081.rst
index 793c3fdd5..df2192313 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc081.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc081.rst
@@ -14,8 +14,8 @@ Yardstick Test Case Description TC081
|Network Latency |
| |
+--------------+--------------------------------------------------------------+
-|test case id | OPNFV_YARDSTICK_TC081_NETWORK_LATENCY_BETWEEN_CONTAINER_AND_ |
-| | VM |
+|test case id | OPNFV_YARDSTICK_TC081_NETWORK_LATENCY_BETWEEN_CONTAINER_AND |
+| | _VM |
| | |
+--------------+--------------------------------------------------------------+
|metric | RTT (Round Trip Time) |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc084.rst b/docs/testing/user/userguide/opnfv_yardstick_tc084.rst
index 2e7b28e25..b3d44c4bf 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc084.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc084.rst
@@ -92,18 +92,19 @@ Yardstick Test Case Description TC084
+--------------+--------------------------------------------------------------+
|pre-test | To run and install SPEC CPU 2006, the following are |
|conditions | required: |
-| | * For SPECint 2006: Both C99 and C++98 compilers are |
-| | installed in VM images; |
-| | * For SPECfp 2006: All three of C99, C++98 and Fortran-95 |
-| | compilers installed in VM images; |
-| | * At least 4GB of disk space availabile on VM. |
-| | |
-| | gcc 4.8.* and g++ 4.8.* version have been tested in Ubuntu |
-| | 14.04, Ubuntu 16.04 and Redhat Enterprise Linux 7.4 image. |
-| | Higher gcc and g++ version may cause compiling error. |
-| | |
-| | For more SPEC CPU 2006 dependencies please visit |
-| | (https://www.spec.org/cpu2006/Docs/techsupport.html) |
+| | |
+| | * For SPECint 2006: Both C99 and C++98 compilers are |
+| | installed in VM images; |
+| | * For SPECfp 2006: All three of C99, C++98 and Fortran-95 |
+| | compilers installed in VM images; |
+| | * At least 4GB of disk space availabile on VM. |
+| | |
+| | gcc 4.8.* and g++ 4.8.* version have been tested in Ubuntu |
+| | 14.04, Ubuntu 16.04 and Redhat Enterprise Linux 7.4 image. |
+| | Higher gcc and g++ version may cause compiling error. |
+| | |
+| | For more SPEC CPU 2006 dependencies please visit |
+| | (https://www.spec.org/cpu2006/Docs/techsupport.html) |
| | |
+--------------+--------------------------------------------------------------+
|test sequence | description and expected result |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst
index 99bfeebfc..c11252606 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst
@@ -41,6 +41,7 @@ Yardstick Test Case Description TC087
+--------------+--------------------------------------------------------------+
|attackers | In this test case, an attacker called “kill-process” is |
| | needed. This attacker includes three parameters: |
+| | |
| | 1. fault_type: which is used for finding the attacker's |
| | scripts. It should be set to 'kill-process' in this test |
| | |
@@ -58,6 +59,7 @@ Yardstick Test Case Description TC087
|monitors | This test case utilizes two monitors of type "ip-status" |
| | and one monitor of type "process" to track the following |
| | conditions: |
+| | |
| | 1. "ping_same_network_l2": monitor ICMP traffic between |
| | VMs in the same Neutron network |
| | |
@@ -74,11 +76,13 @@ Yardstick Test Case Description TC087
| | |
+--------------+--------------------------------------------------------------+
|operations | In this test case, the following operations are needed: |
+| | |
| | 1. "nova-create-instance-in_network": create a VM instance |
| | in one of the existing Neutron network. |
| | |
+--------------+--------------------------------------------------------------+
|metrics | In this test case, there are two metrics: |
+| | |
| | 1. process_recover_time: which indicates the maximun |
| | time (seconds) from the process being killed to |
| | recovered |
@@ -95,7 +99,9 @@ Yardstick Test Case Description TC087
| | |
+--------------+--------------------------------------------------------------+
|configuration | This test case needs two configuration files: |
+| | |
| | 1. test case file: opnfv_yardstick_tc087.yaml |
+| | |
| | - Attackers: see above “attackers” discription |
| | - waiting_time: which is the time (seconds) from the |
| | process being killed to stoping monitors the monitors |
@@ -126,7 +132,7 @@ Yardstick Test Case Description TC087
| | Neutron network. |
| | |
| | 2. Check connectivity from one VM to an external host on |
-| | the Internet to verify SNAT functionality.
+| | the Internet to verify SNAT functionality. |
| | |
| | Result: The monitor info will be collected. |
| | |
@@ -171,11 +177,14 @@ Yardstick Test Case Description TC087
|test verdict | This test fails if the SLAs are not met or if there is a |
| | test case execution problem. The SLAs are define as follows |
| | for this test: |
+| | |
| | * SDN Controller recovery |
+| | |
| | * process_recover_time <= 30 sec |
| | |
| | * no impact on data plane connectivity during SDN |
| | controller failure and recovery. |
+| | |
| | * packet_drop == 0 |
| | |
+--------------+--------------------------------------------------------------+
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc092.rst b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst
index 895074a85..9c833fa23 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc092.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst
@@ -43,6 +43,7 @@ Yardstick Test Case Description TC092
+--------------+--------------------------------------------------------------+
|attackers | In this test case, an attacker called “kill-process” is |
| | needed. This attacker includes three parameters: |
+| | |
| | 1. ``fault_type``: which is used for finding the attacker's |
| | scripts. It should be set to 'kill-process' in this test |
| | |
@@ -92,17 +93,20 @@ Yardstick Test Case Description TC092
| | |
+--------------+--------------------------------------------------------------+
|configuration | This test case needs two configuration files: |
-| | 1. test case file: opnfv_yardstick_tc092.yaml |
-| | - Attackers: see above “attackers” discription |
-| | - Monitors: see above “monitors” discription |
-| | - waiting_time: which is the time (seconds) from the |
-| | process being killed to stoping monitors the |
-| | monitors |
-| | - SLA: see above “metrics” discription |
+| | 1. test case file: opnfv_yardstick_tc092.yaml |
+| | |
+| | - Attackers: see above “attackers” discription |
+| | - Monitors: see above “monitors” discription |
+| | |
+| | - waiting_time: which is the time (seconds) from the |
+| | process being killed to stoping monitors the |
+| | monitors |
| | |
-| | 2. POD file: pod.yaml The POD configuration should record |
-| | on pod.yaml first. the “host” item in this test case |
-| | will use the node name in the pod.yaml. |
+| | - SLA: see above “metrics” discription |
+| | |
+| | 2. POD file: pod.yaml The POD configuration should record |
+| | on pod.yaml first. the “host” item in this test case |
+| | will use the node name in the pod.yaml. |
| | |
+--------------+--------------------------------------------------------------+
|test sequence | Description and expected result |
@@ -168,11 +172,12 @@ Yardstick Test Case Description TC092
| | |
+--------------+--------------------------------------------------------------+
|step 8 | Start IP connectivity monitors for the new VM: |
-| | 1. Check the L2 connectivity from the existing VMs to the |
-| | new VM in the Neutron network. |
| | |
-| | 2. Check connectivity from one VM to an external host on |
-| | the Internet to verify SNAT functionality. |
+| | 1. Check the L2 connectivity from the existing VMs to the |
+| | new VM in the Neutron network. |
+| | |
+| | 2. Check connectivity from one VM to an external host on |
+| | the Internet to verify SNAT functionality. |
| | |
| | Result: The monitor info will be collected. |
| | |
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
index 31fa5d3d3..4e22e8bf3 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
@@ -43,14 +43,15 @@ Yardstick Test Case Description TC093
+--------------+--------------------------------------------------------------+
|attackers | In this test case, two attackers called “kill-process” are |
| | needed. These attackers include three parameters: |
-| | 1. fault_type: which is used for finding the attacker's |
-| | scripts. It should be set to 'kill-process' in this test |
| | |
-| | 2. process_name: should be set to the name of the Vswitch |
-| | process |
+| | 1. fault_type: which is used for finding the attacker's |
+| | scripts. It should be set to 'kill-process' in this test |
| | |
-| | 3. host: which is the name of the compute node where the |
-| | Vswitch process is running |
+| | 2. process_name: should be set to the name of the Vswitch |
+| | process |
+| | |
+| | 3. host: which is the name of the compute node where the |
+| | Vswitch process is running |
| | |
| | e.g. -fault_type: "kill-process" |
| | -process_name: "openvswitch" |
@@ -60,16 +61,17 @@ Yardstick Test Case Description TC093
|monitors | This test case utilizes two monitors of type "ip-status" |
| | and one monitor of type "process" to track the following |
| | conditions: |
-| | 1. "ping_same_network_l2": monitor ICMP traffic between |
-| | VMs in the same Neutron network |
| | |
-| | 2. "ping_external_snat": monitor ICMP traffic from VMs to |
-| | an external host on the Internet to verify SNAT |
-| | functionality. |
+| | 1. "ping_same_network_l2": monitor ICMP traffic between |
+| | VMs in the same Neutron network |
+| | |
+| | 2. "ping_external_snat": monitor ICMP traffic from VMs to |
+| | an external host on the Internet to verify SNAT |
+| | functionality. |
| | |
-| | 3. "Vswitch process monitor": a monitor checking the |
-| | state of the specified Vswitch process. It measures |
-| | the recovery time of the given process. |
+| | 3. "Vswitch process monitor": a monitor checking the |
+| | state of the specified Vswitch process. It measures |
+| | the recovery time of the given process. |
| | |
| | Monitors of type "ip-status" use the "ping" utility to |
| | verify reachability of a given target IP. |
@@ -99,6 +101,7 @@ Yardstick Test Case Description TC093
+--------------+--------------------------------------------------------------+
|configuration | This test case needs two configuration files: |
| | 1. test case file: opnfv_yardstick_tc093.yaml |
+| | |
| | - Attackers: see above “attackers” description |
| | - monitor_time: which is the time (seconds) from |
| | starting to stoping the monitors |
@@ -173,12 +176,14 @@ Yardstick Test Case Description TC093
|test verdict | This test fails if the SLAs are not met or if there is a |
| | test case execution problem. The SLAs are define as follows |
| | for this test: |
-| | * SDN Vswitch recovery |
-| | * process_recover_time <= 30 sec |
+| | * SDN Vswitch recovery |
+| | |
+| | * process_recover_time <= 30 sec |
+| | |
+| | * no impact on data plane connectivity during SDN |
+| | Vswitch failure and recovery. |
| | |
-| | * no impact on data plane connectivity during SDN |
-| | Vswitch failure and recovery. |
-| | * packet_drop == 0 |
+| | * packet_drop == 0 |
| | |
+--------------+--------------------------------------------------------------+
diff --git a/docs/testing/user/userguide/references.rst b/docs/testing/user/userguide/references.rst
index 3e18c96e9..e6bc719fd 100644
--- a/docs/testing/user/userguide/references.rst
+++ b/docs/testing/user/userguide/references.rst
@@ -11,12 +11,12 @@ References
OPNFV
=====
-* Parser wiki: https://wiki.opnfv.org/parser
-* Pharos wiki: https://wiki.opnfv.org/pharos
+* Parser wiki: https://wiki.opnfv.org/display/parser
+* Pharos wiki: https://wiki.opnfv.org/display/pharos
* Yardstick CI: https://build.opnfv.org/ci/view/yardstick/
* Yardstick and ETSI TST001 presentation: https://wiki.opnfv.org/display/yardstick/Yardstick?preview=%2F2925202%2F2925205%2Fopnfv_summit_-_bridging_opnfv_and_etsi.pdf
* Yardstick Project presentation: https://wiki.opnfv.org/display/yardstick/Yardstick?preview=%2F2925202%2F2925208%2Fopnfv_summit_-_yardstick_project.pdf
-* Yardstick wiki: https://wiki.opnfv.org/yardstick
+* Yardstick wiki: https://wiki.opnfv.org/display/yardstick
References used in Test Cases
=============================
@@ -25,22 +25,22 @@ References used in Test Cases
* cirros-image: https://download.cirros-cloud.net
* cyclictest: https://rt.wiki.kernel.org/index.php/Cyclictest
* DPDKpktgen: https://github.com/Pktgen/Pktgen-DPDK/
-* DPDK supported NICs: http://dpdk.org/doc/nics
+* DPDK supported NICs: http://core.dpdk.org/supported/
* fdisk: http://www.tldp.org/HOWTO/Partition/fdisk_partitioning.html
-* fio: http://www.bluestop.org/fio/HOWTO.txt
+* fio: https://bluestop.org/files/fio/HOWTO.txt
* free: http://manpages.ubuntu.com/manpages/trusty/en/man1/free.1.html
* iperf3: https://iperf.fr/
-* iostat: http://linux.die.net/man/1/iostat
+* iostat: https://linux.die.net/man/1/iostat
* Lmbench man-pages: http://manpages.ubuntu.com/manpages/trusty/lat_mem_rd.8.html
* Memory bandwidth man-pages: http://manpages.ubuntu.com/manpages/trusty/bw_mem.8.html
* mpstat man-pages: http://manpages.ubuntu.com/manpages/trusty/man1/mpstat.1.html
-* netperf: http://www.netperf.org/netperf/training/Netperf.html
+* netperf: https://hewlettpackard.github.io/netperf/
* pktgen: https://www.kernel.org/doc/Documentation/networking/pktgen.txt
* RAMspeed: http://alasir.com/software/ramspeed/
-* sar: http://linux.die.net/man/1/sar
+* sar: https://linux.die.net/man/1/sar
* SR-IOV: https://wiki.openstack.org/wiki/SR-IOV-Passthrough-For-Networking
* Storperf: https://wiki.opnfv.org/display/storperf/Storperf
-* unixbench: https://github.com/kdlucas/byte-unixbench/blob/master/UnixBench
+* unixbench: https://github.com/kdlucas/byte-unixbench/tree/master/UnixBench
Research
@@ -53,7 +53,7 @@ Research
Standards
=========
-* ETSI NFV: http://www.etsi.org/technologies-clusters/technologies/nfv
-* ETSI GS-NFV TST 001: http://www.etsi.org/deliver/etsi_gs/NFV-TST/001_099/001/01.01.01_60/gs_NFV-TST001v010101p.pdf
+* ETSI NFV: https://www.etsi.org/technologies-clusters/technologies/nfv
+* ETSI GS-NFV TST 001: https://www.etsi.org/deliver/etsi_gs/NFV-TST/001_099/001/01.01.01_60/gs_NFV-TST001v010101p.pdf
* RFC2544: https://www.ietf.org/rfc/rfc2544.txt