diff options
Diffstat (limited to 'docs/testing/user')
-rw-r--r-- | docs/testing/user/userguide/04-installation.rst | 4 | ||||
-rw-r--r-- | docs/testing/user/userguide/10-yardstick-user-interface.rst | 30 | ||||
-rw-r--r-- | docs/testing/user/userguide/glossary.rst | 60 | ||||
-rw-r--r-- | docs/testing/user/userguide/nsb/nsb-list-of-tcs.rst | 3 | ||||
-rw-r--r-- | docs/testing/user/userguide/nsb/tc_vfw_rfc2544.rst | 189 | ||||
-rw-r--r-- | docs/testing/user/userguide/nsb/tc_vfw_rfc2544_correlated.rst | 130 | ||||
-rw-r--r-- | docs/testing/user/userguide/nsb/tc_vfw_rfc3511.rst | 133 |
7 files changed, 537 insertions, 12 deletions
diff --git a/docs/testing/user/userguide/04-installation.rst b/docs/testing/user/userguide/04-installation.rst index 2f8175c25..3ba312ce7 100644 --- a/docs/testing/user/userguide/04-installation.rst +++ b/docs/testing/user/userguide/04-installation.rst @@ -613,15 +613,15 @@ Run influxDB:: sudo -EH docker run -d --name influxdb \ -p 8083:8083 -p 8086:8086 --expose 8090 --expose 8099 \ tutum/influxdb - docker exec -it influxdb influx Configure influxDB:: + docker exec -it influxdb influx > CREATE USER root WITH PASSWORD 'root' WITH ALL PRIVILEGES > CREATE DATABASE yardstick; > use yardstick; > show MEASUREMENTS; - > quit + > exit Run Grafana:: diff --git a/docs/testing/user/userguide/10-yardstick-user-interface.rst b/docs/testing/user/userguide/10-yardstick-user-interface.rst index 76890b29a..b3056ec99 100644 --- a/docs/testing/user/userguide/10-yardstick-user-interface.rst +++ b/docs/testing/user/userguide/10-yardstick-user-interface.rst @@ -2,16 +2,32 @@ Yardstick User Interface ======================== -This interface provides a user to view the test result -in table format and also values pinned on to a graph. +This chapter describes how to generate HTML reports, used to view, store, share +or publish test results in table and graph formats. +The following layouts are available: -Command -======= -:: +* The compact HTML report layout is suitable for testcases producing a few + metrics over a short period of time. All metrics for all timestamps are + displayed in the data table and on the graph. + +* The dynamic HTML report layout consists of a wider data table, a graph, and + a tree that allows selecting the metrics to be displayed. This layout is + suitable for testcases, such as NSB ones, producing a lot of metrics over + a longer period of time. + + +Commands +======== + +To generate the compact HTML report, run:: yardstick report generate <task-ID> <testcase-filename> +To generate the dynamic HTML report, run:: + + yardstick report generate-nsb <task-ID> <testcase-filename> + Description =========== @@ -27,8 +43,8 @@ Description The graph is framed with Timestamp on x-axis and output values (differ from testcase to testcase) on y-axis with the help of -`Highcharts`_. +`Chart.js`_. .. _InfluxDB: https://www.influxdata.com/time-series-platform/influxdb/ .. _Jinja2: http://jinja.pocoo.org/docs/2.10/ -.. _Highcharts: https://www.highcharts.com/products/highcharts/ +.. _Chart.js: https://www.chartjs.org/ diff --git a/docs/testing/user/userguide/glossary.rst b/docs/testing/user/userguide/glossary.rst index 6a153943c..cef9b69a5 100644 --- a/docs/testing/user/userguide/glossary.rst +++ b/docs/testing/user/userguide/glossary.rst @@ -13,23 +13,54 @@ Glossary API Application Programming Interface + Barometer + OPNFV NFVi Service Assurance project. Barometer upstreams changes to + collectd, OpenStack, etc to improve features related to NFVi monitoring + and service assurance. + More info on: https://opnfv-barometer.readthedocs.io/en/latest/ + + collectd + collectd is a system statistics collection daemon. + More info on: https://collectd.org/ + + context + A context describes the environment in which a yardstick testcase will + be run. It can refer to a pre-provisioned environment, or an environment + that will be set up using OpenStack or Kubernetes. + Docker Docker provisions and manages containers. Yardstick and many other OPNFV projects are deployed in containers. Docker is required to launch the containerized versions of these projects. - DPI - Deep Packet Inspection - DPDK Data Plane Development Kit + DPI + Deep Packet Inspection + DSCP Differentiated Services Code Point + flavor + A specification of virtual resources used by OpenStack in the creation + of a VM instance. + + Grafana + A visualization tool, used in Yardstick to retrieve test data from + InfluxDB and display it. Grafana works by defining dashboards, which are + combinations of visualization panes (e.g. line charts and gauges) and + forms that assist the user in formulating SQL-like queries for InfluxDB. + More info on: https://grafana.com/ + IGMP Internet Group Management Protocol + InfluxDB + One of the Dispatchers supported by Yardstick, it allows test results to + be reported to a time-series database. + More info on: https://www.influxdata.com/ + IOPS Input/Output Operations Per Second A performance measurement used to benchmark storage devices. @@ -43,6 +74,9 @@ Glossary deployment, scaling and management of containerized applications. It is one of the contexts supported in Yardstick. + MPLS + Multiprotocol Label Switching + NFV Network Function Virtualization NFV is an initiative to take network services which were traditionally run @@ -56,6 +90,10 @@ Glossary NIC Network Interface Controller + NSB + Network Services Benchmarking. A subset of Yardstick features concerned + with NFVI and VNF characterization. + OpenStack OpenStack is a cloud operating system that controls pools of compute, storage, and networking resources. OpenStack is an open source project @@ -77,6 +115,18 @@ Glossary performance in Input/Output Operations Per Second (IOPS), throttling agreements, and performance expectations at peak load + runner + The part of a Yardstick testcase that determines how the test will be run + (e.g. for x iterations, y seconds or until state z is reached). The runner + also determines when the metrics are collected/reported. + + SampleVNF + OPNFV project providing a repository of reference VNFs. + More info on: https://opnfv-samplevnf.readthedocs.io/en/latest/ + + scenario + The part of a Yardstick testcase that describes each test step. + SLA Service Level Agreement An SLA is an agreement between a service provider and a customer to @@ -92,6 +142,10 @@ Glossary SUT System Under Test + testcase + A task in Yardstick; the yaml file that is read by Yardstick to + determine how to run a test. + ToS Type of Service diff --git a/docs/testing/user/userguide/nsb/nsb-list-of-tcs.rst b/docs/testing/user/userguide/nsb/nsb-list-of-tcs.rst index 723cd6f99..6c18c7d89 100644 --- a/docs/testing/user/userguide/nsb/nsb-list-of-tcs.rst +++ b/docs/testing/user/userguide/nsb/nsb-list-of-tcs.rst @@ -33,3 +33,6 @@ NSB PROX Test Case Descriptions tc_epc_saegw_tput_relocation_landslide tc_epc_network_service_request_landslide tc_epc_ue_service_request_landslide + tc_vfw_rfc2544 + tc_vfw_rfc2544_correlated + tc_vfw_rfc3511 diff --git a/docs/testing/user/userguide/nsb/tc_vfw_rfc2544.rst b/docs/testing/user/userguide/nsb/tc_vfw_rfc2544.rst new file mode 100644 index 000000000..139990bc3 --- /dev/null +++ b/docs/testing/user/userguide/nsb/tc_vfw_rfc2544.rst @@ -0,0 +1,189 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International +.. License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, 2018 Intel Corporation. + +************************************************ +Yardstick Test Case Description: NSB vFW RFC2544 +************************************************ + ++------------------------------------------------------------------------------+ +| NSB vFW test for VNF characterization | +| | ++---------------+--------------------------------------------------------------+ +| test case id | tc_{context}_rfc2544_ipv4_1rule_1flow_{pkt_size}_{tg_type} | +| | | +| | * context = baremetal, heat, heat_external, ovs, sriov | +| | heat_sriov_external contexts; | +| | * tg_type = ixia (context != heat,heat_sriov_external), | +| | trex; | +| | * pkt_size = 64B - all contexts; | +| | 128B, 256B, 512B, 1024B, 1280B, 1518B - | +| | (context = heat, tg_type = ixia) | +| | | ++---------------+--------------------------------------------------------------+ +| metric | * Network Throughput; | +| | * TG Packets Out; | +| | * TG Packets In; | +| | * TG Latency; | +| | * VNF Packets Out; | +| | * VNF Packets In; | +| | * VNF Packets Fwd; | +| | * Dropped packets; | +| | | ++---------------+--------------------------------------------------------------+ +| test purpose | The VFW RFC2544 tests measure performance characteristics of | +| | the SUT (multiple ports) and sends UDP bidirectional traffic | +| | from all TG ports to SampleVNF vFW application. The | +| | application forwards received traffic based on rules | +| | provided by the user in the TC configuration and default | +| | rules created by vFW to send traffic from uplink ports to | +| | downlink and voice versa. | +| | | ++---------------+--------------------------------------------------------------+ +| configuration | The 2 ports RFC2544 test cases are listed below: | +| | | +| | * tc_baremetal_rfc2544_ipv4_1rule_1flow_64B_ixia.yaml | +| | * tc_baremetal_rfc2544_ipv4_1rule_1flow_64B_trex.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_1024B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_1280B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_128B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_1518B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_256B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_512B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_64B_ixia.yaml | +| | * tc_heat_external_rfc2544_ipv4_1rule_1flow_64B_trex.yaml | +| | * tc_heat_sriov_external_rfc2544_ipv4_1rule_1flow_64B_trex. | +| | yaml | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex.yaml | +| | * tc_ovs_rfc2544_ipv4_1rule_1flow_64B_ixia.yaml | +| | * tc_ovs_rfc2544_ipv4_1rule_1flow_64B_trex.yaml | +| | * tc_sriov_rfc2544_ipv4_1rule_1flow_64B_ixia.yaml | +| | * tc_sriov_rfc2544_ipv4_1rule_1flow_64B_trex.yaml | +| | | +| | The 4 ports RFC2544 test cases are listed below: | +| | | +| | * tc_baremetal_rfc2544_ipv4_1rule_1flow_64B_ixia_4port.yaml | +| | * tc_tc_baremetal_rfc2544_ipv4_1rule_1flow_64B_trex_4port. | +| | yaml | +| | * tc_tc_heat_external_rfc2544_ipv4_1rule_1flow_64B_trex_4 | +| | port.yaml | +| | * tc_tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_4port.yaml | +| | | +| | The scale-up RFC2544 test cases are listed below: | +| | | +| | * tc_tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale-up.yaml | +| | | +| | The scale-out RFC2544 test cases are listed below: | +| | | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale_out.yaml | +| | | +| | Test duration is set as 30 sec for each test and default | +| | number of rules are applied. These can be configured | +| | | ++---------------+--------------------------------------------------------------+ +| test tool | The vFW is a DPDK application that performs basic filtering | +| | for malformed packets and dynamic packet filtering of | +| | incoming packets using the connection tracker library. | +| | | ++---------------+--------------------------------------------------------------+ +| applicability | The vFW RFC2544 test cases can be configured with different: | +| | | +| | * packet sizes; | +| | * test duration; | +| | * tolerated loss; | +| | * traffic flows; | +| | * rules; | +| | | +| | Default values exist. | +| | | ++---------------+--------------------------------------------------------------+ +| pre-test | For OpenStack test case image (yardstick-samplevnf) needs | +| conditions | to be installed into Glance with vFW and DPDK included in | +| | it (NSB install). | +| | | +| | For Baremetal tests cases vFW and DPDK must be installed on | +| | the hosts where the test is executed. The pod.yaml file must | +| | have the necessary system and NIC information. | +| | | +| | For standalone (SA) SRIOV/OvS test cases the | +| | yardstick-samplevnf image needs to be installed on hosts and | +| | pod.yaml file must be provided with necessary system, NIC | +| | information. | +| | | ++---------------+--------------------------------------------------------------+ +| test sequence | Description and expected result | +| | | ++---------------+--------------------------------------------------------------+ +| step 1 | For Baremetal test: The TG (except IXIA) and VNF are started | +| | on the hosts based on the pod file. | +| | | +| | For Heat test: Two host VMs are booted, as Traffic generator | +| | and VNF(vFW) based on the test flavor. In case of scale-out | +| | scenario the multiple VNF VMs will be started. | +| | | +| | For Heat external test: vFW VM is booted and TG (except IXIA)| +| | generator is started on the external host based on the pod | +| | file. In case of scale-out scenario the multiple VNF VMs | +| | will be deployed. | +| | | +| | For Heat SRIOV external test: vFW VM is booted with network | +| | interfaces of `direct` type which are mapped to VFs that are | +| | available to OpenStack. TG (except IXIA) is started on the | +| | external host based on the pod file. In case of scale-out | +| | scenario the multiple VNF VMs will be deployed. | +| | | +| | For SRIOV test: VF ports are created on host's PFs specified | +| | in the TC file and VM is booed using those ports and image | +| | provided in the configuration. TG (except IXIA) is started | +| | on other host connected to VNF machine based on the pod | +| | file. The vFW is started in the booted VM. In case of | +| | scale-out scenario the multiple VNF VMs will be created. | +| | | +| | For OvS-DPDK test: OvS DPDK switch is started and bridges | +| | are created with ports specified in the TC file. DPDK vHost | +| | ports are added to corresponding bridge and VM is booed | +| | using those ports and image provided in the configuration. | +| | TG (except IXIA) is started on other host connected to VNF | +| | machine based on the pod file. The vFW is started in the | +| | booted VM. In case of scale-out scenario the multiple VNF | +| | VMs will be deployed. | +| | | ++---------------+--------------------------------------------------------------+ +| step 2 | Yardstick is connected with the TG and VNF by using ssh (in | +| | case of IXIA TG is connected via TCL interface). The test | +| | will resolve the topology and instantiate all VNFs | +| | and TG and collect the KPI's/metrics. | +| | | ++---------------+--------------------------------------------------------------+ +| step 3 | The TG will send packets to the VNFs. If the number of | +| | dropped packets is more than the tolerated loss the line | +| | rate or throughput is halved. This is done until the dropped | +| | packets are within an acceptable tolerated loss. | +| | | +| | The KPI is the number of packets per second for different | +| | packet size with an accepted minimal packet loss for the | +| | default configuration. | +| | | ++---------------+--------------------------------------------------------------+ +| step 4 | In Baremetal test: The test quits the application and unbind | +| | the DPDK ports. | +| | | +| | In Heat test: All VNF VMs and TG are deleted on test | +| | completion. | +| | | +| | In SRIOV test: The deployed VM with vFW is destroyed on the | +| | host and TG (exclude IXIA) is stopped. | +| | | +| | In Heat SRIOV test: The deployed VM with vFW is destroyed, | +| | VFs are released and TG (exclude IXIA) is stopped. | +| | | +| | In OvS test: The deployed VM with vFW is destroyed on the | +| | host and OvS DPDK switch is stopped and ports are unbinded. | +| | The TG (exclude IXIA) is stopped. | +| | | ++---------------+--------------------------------------------------------------+ +| test verdict | The test case will achieve a Throughput with an accepted | +| | minimal tolerated packet loss. | ++---------------+--------------------------------------------------------------+ + diff --git a/docs/testing/user/userguide/nsb/tc_vfw_rfc2544_correlated.rst b/docs/testing/user/userguide/nsb/tc_vfw_rfc2544_correlated.rst new file mode 100644 index 000000000..de490900d --- /dev/null +++ b/docs/testing/user/userguide/nsb/tc_vfw_rfc2544_correlated.rst @@ -0,0 +1,130 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International +.. License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, 2018 Intel Corporation. + +************************************************************* +Yardstick Test Case Description: NSB vFW RFC2544 (correlated) +************************************************************* + ++------------------------------------------------------------------------------+ +| NSB vFW test for VNF characterization using correlated traffic | +| | ++---------------+--------------------------------------------------------------+ +| test case id | tc_{context}_rfc2544_ipv4_1rule_1flow_64B_trex_corelated | +| | | +| | * context = baremetal, heat | +| | | ++---------------+--------------------------------------------------------------+ +| metric | * Network Throughput; | +| | * TG Packets Out; | +| | * TG Packets In; | +| | * TG Latency; | +| | * VNF Packets Out; | +| | * VNF Packets In; | +| | * VNF Packets Fwd; | +| | * Dropped packets; | +| | | +| | NOTE: For correlated TCs the TG metrics are available on | +| | uplink ports. | +| | | ++---------------+--------------------------------------------------------------+ +| test purpose | The VFW RFC2544 correlated tests measure performance | +| | characteristics of the SUT (multiple ports) and sends UDP | +| | traffic from uplink TG ports to SampleVNF vFW application. | +| | The application forwards received traffic from uplink ports | +| | to downlink ports based on rules provided by the user in the | +| | TC configuration and default rules created by vFW. The VNF | +| | downlink traffic is received by another UDPReplay VNF and it | +| | is mirrored back to the VNF on the same port. Finally, the | +| | traffic is received back to the TG uplink port. | +| | | ++---------------+--------------------------------------------------------------+ +| configuration | The 2 ports RFC2544 correlated test cases are listed below: | +| | | +| | * tc_baremetal_rfc2544_ipv4_1rule_1flow_64B_trex_corelated | +| | _traffic.yaml | +| | | +| | Multiple VNF (2, 4, 10) RFC2544 correlated test cases are | +| | listed below: | +| | | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_correlated | +| | _scale_10.yaml | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_correlated_scale | +| | _2.yaml | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_correlated_scale | +| | _4.yaml | +| | | +| | The scale-out RFC2544 test cases are listed below: | +| | | +| | * tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_correlated_scale | +| | _out.yaml | +| | | +| | Test duration is set as 30 sec for each test and default | +| | number of rules are applied. These can be configured | +| | | ++---------------+--------------------------------------------------------------+ +| test tool | The vFW is a DPDK application that performs basic filtering | +| | for malformed packets and dynamic packet filtering of | +| | incoming packets using the connection tracker library. | +| | | ++---------------+--------------------------------------------------------------+ +| applicability | The vFW RFC2544 test cases can be configured with different: | +| | | +| | * packet sizes; | +| | * test duration; | +| | * tolerated loss; | +| | * traffic flows; | +| | * rules; | +| | | +| | Default values exist. | +| | | ++---------------+--------------------------------------------------------------+ +| pre-test | For OpenStack test case image (yardstick-samplevnf) needs | +| conditions | to be installed into Glance with vFW and DPDK included in | +| | it (NSB install). | +| | | +| | For Baremetal tests cases vFW and DPDK must be installed on | +| | the hosts where the test is executed. The pod.yaml file must | +| | have the necessary system and NIC information. | +| | | ++---------------+--------------------------------------------------------------+ +| test sequence | Description and expected result | +| | | ++---------------+--------------------------------------------------------------+ +| step 1 | For Baremetal test: The TG (except IXIA), vFW and UDPReplay | +| | VNFs are started on the hosts based on the pod file. | +| | | +| | For Heat test: Three host VMs are booted, as Traffic | +| | generator, vFW and UDPReplay VNF(vFW) based on the test | +| | flavor. In case of scale-out scenario the multiple vFW VNF | +| | VMs will be started. | +| | | ++---------------+--------------------------------------------------------------+ +| step 2 | Yardstick is connected with the TG, vFW and UDPReplay VNF by | +| | using ssh (in case of IXIA TG is connected via TCL | +| | interface). The test will resolve the topology and | +| | instantiate all VNFs and TG and collect the KPI's/metrics. | +| | | ++---------------+--------------------------------------------------------------+ +| step 3 | The TG will send packets to the VNFs. If the number of | +| | dropped packets is more than the tolerated loss the line | +| | rate or throughput is halved. This is done until the dropped | +| | packets are within an acceptable tolerated loss. | +| | | +| | The KPI is the number of packets per second for 64B packet | +| | size with an accepted minimal packet loss for the default | +| | configuration. | +| | | ++---------------+--------------------------------------------------------------+ +| step 4 | In Baremetal test: The test quits the application and unbind | +| | the DPDK ports. | +| | | +| | In Heat test: All VNF VMs and TG are deleted on test | +| | completion. | +| | | ++---------------+--------------------------------------------------------------+ +| test verdict | The test case will achieve a Throughput with an accepted | +| | minimal tolerated packet loss. | ++---------------+--------------------------------------------------------------+ + diff --git a/docs/testing/user/userguide/nsb/tc_vfw_rfc3511.rst b/docs/testing/user/userguide/nsb/tc_vfw_rfc3511.rst new file mode 100644 index 000000000..9051fc4df --- /dev/null +++ b/docs/testing/user/userguide/nsb/tc_vfw_rfc3511.rst @@ -0,0 +1,133 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International +.. License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, 2018 Intel Corporation. + +******************************************************* +Yardstick Test Case Description: NSB vFW RFC3511 (HTTP) +******************************************************* + ++------------------------------------------------------------------------------+ +| NSB vFW test for VNF characterization based on RFC3511 and IXIA | +| | ++---------------+--------------------------------------------------------------+ +| test case id | tc_{context}_http_ixload_{http_size}_Requests-65000_{type} | +| | | +| | * context = baremetal, heat_external | +| | * http_size = 1b, 4k, 64k, 256k, 512k, 1024k payload size | +| | * type = Concurrency, Connections, Throughput | +| | | ++---------------+--------------------------------------------------------------+ +| metric | * HTTP Total Throughput (Kbps); | +| | * HTTP Simulated Users; | +| | * HTTP Concurrent Connections; | +| | * HTTP Connection Rate; | +| | * HTTP Transaction Rate | +| | | ++---------------+--------------------------------------------------------------+ +| test purpose | The vFW RFC3511 tests measure performance characteristics of | +| | the SUT by sending the HTTP traffic from uplink to downlink | +| | TG ports through vFW VNF. The application forwards received | +| | traffic based on rules provided by the user in the TC | +| | configuration and default rules created by vFW to send | +| | traffic from uplink ports to downlink and voice versa. | +| | | ++---------------+--------------------------------------------------------------+ +| configuration | The 2 ports RFC3511 test cases are listed below: | +| | | +| | * tc_baremetal_http_ixload_1024k_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_baremetal_http_ixload_1b_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_baremetal_http_ixload_256k_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_baremetal_http_ixload_4k_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_baremetal_http_ixload_512k_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_baremetal_http_ixload_64k_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_heat_external_http_ixload_1b_Requests-10Gbps | +| | _Throughput.yaml | +| | * tc_heat_external_http_ixload_1b_Requests-65000 | +| | _Concurrency.yaml | +| | * tc_heat_external_http_ixload_1b_Requests-65000 | +| | _Connections.yaml | +| | | +| | The 4 ports RFC3511 test cases are listed below: | +| | | +| | * tc_baremetal_http_ixload_1b_Requests-65000 | +| | _Concurrency_4port.yaml | +| | | ++---------------+--------------------------------------------------------------+ +| test tool | The vFW is a DPDK application that performs basic filtering | +| | for malformed packets and dynamic packet filtering of | +| | incoming packets using the connection tracker library. | +| | | ++---------------+--------------------------------------------------------------+ +| applicability | The vFW RFC3511 test cases can be configured with different: | +| | | +| | * http payload sizes; | +| | * traffic flows; | +| | * rules; | +| | | +| | Default values exist. | +| | | ++---------------+--------------------------------------------------------------+ +| pre-test | For OpenStack test case image (yardstick-samplevnf) needs | +| conditions | to be installed into Glance with vFW and DPDK included in | +| | it (NSB install). | +| | | +| | For Baremetal tests cases vFW and DPDK must be installed on | +| | the hosts where the test is executed. The pod.yaml file must | +| | have the necessary system and NIC information. | +| | | ++---------------+--------------------------------------------------------------+ +| test sequence | Description and expected result | +| | | ++---------------+--------------------------------------------------------------+ +| step 1 | For Baremetal test: The vFW VNF is started on the hosts | +| | based on the pod file. | +| | | +| | For Heat external test: The vFW VM are deployed and booted. | +| | | ++---------------+--------------------------------------------------------------+ +| step 2 | Yardstick is connected with the TG (IxLoad) via IxLoad API | +| | and VNF by using ssh. The test will resolve the topology and | +| | instantiate all VNFs and TG and collect the KPI's/metrics. | +| | | ++---------------+--------------------------------------------------------------+ +| step 3 | The TG simulates HTTP traffic based on selected type of TC. | +| | | +| | Concurrency: | +| | The TC attempts to simulate some number of human users. | +| | The simulated users are gradually brought online until 64K | +| | users is met (the Ramp-Up phase), then taken offline (the | +| | Ramp Down phase). | +| | | +| | Connections: | +| | The TC creates some number of HTTP connections per second. | +| | It will attempt to generate the 64K of HTTP connections | +| | per second. | +| | | +| | Throughput: | +| | TC simultaneously transmits and receives TCP payload | +| | (bytes) at a certain rate measured in Megabits per second | +| | (Mbps), Kilobits per second (Kbps), or Gigabits per | +| | second. The 10 Gbits is default throughput. | +| | | +| | At the end of the TC, the KPIs are collected and stored | +| | (depends on the selected dispatcher). | +| | | ++---------------+--------------------------------------------------------------+ +| step 4 | In Baremetal test: The test quits the application and | +| | unbinds the DPDK ports. | +| | | +| | In Heat test: All VNF VMs are deleted and connections to TG | +| | are terminated. | +| | | ++---------------+--------------------------------------------------------------+ +| test verdict | The test case will try to achieve the configured HTTP | +| | Concurrency/Throughput/Connections. | ++---------------+--------------------------------------------------------------+ + |