@@ -84,6 +84,116 @@ In this example we have ``TRex xe0 <-> xe0 VNF xe1 <-> xe0 UDP_Replay``
downlink_0:
- xe0
+
+Availability zone
+^^^^^^^^^^^^^^^^^
+
+The configuration of the availability zone is requred in cases where location
+of exact compute host/group of compute hosts needs to be specified for SampleVNF
+or traffic generator in the heat test case. If this is the case, please follow
+the instructions below.
+
+.. _`Create a host aggregate`:
+
+1. Create a host aggregate in the OpenStack and add the available compute hosts
+ into the aggregate group.
+
+ .. note:: Change the ``<AZ_NAME>`` (availability zone name), ``<AGG_NAME>``
+ (host aggregate name) and ``<HOST>`` (host name of one of the compute) in the
+ commands below.
+
+ .. code-block:: bash
+
+ # create host aggregate
+ openstack aggregate create --zone <AZ_NAME> --property availability_zone=<AZ_NAME> <AGG_NAME>
+ # show available hosts
+ openstack compute service list --service nova-compute
+ # add selected host into the host aggregate
+ openstack aggregate add host <AGG_NAME> <HOST>
+
+2. To specify the OpenStack location (the exact compute host or group of the hosts)
+ of SampleVNF or traffic generator in the heat test case, the ``availability_zone`` server
+ configuration option should be used. For example:
+
+ .. note:: The ``<AZ_NAME>`` (availability zone name) should be changed according
+ to the name used during the host aggregate creation steps above.
+
+ .. code-block:: yaml
+
+ context:
+ name: yardstick
+ image: yardstick-samplevnfs
+ ...
+ servers:
+ vnf__0:
+ ...
+ availability_zone: <AZ_NAME>
+ ...
+ tg__0:
+ ...
+ availability_zone: <AZ_NAME>
+ ...
+ networks:
+ ...
+
+There are two example of SampleVNF scale out test case which use the availability zone
+feature to specify the exact location of scaled VNFs and traffic generators.
+
+Those are:
+
+.. code-block:: console
+
+ <repo>/samples/vnf_samples/nsut/prox/tc_prox_heat_context_l2fwd_multiflow-2-scale-out.yaml
+ <repo>/samples/vnf_samples/nsut/vfw/tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale_out.yaml
+
+.. note:: This section describes the PROX scale-out testcase, but the same
+ procedure is used for the vFW test case.
+
+1. Before running the scale-out test case, make sure the host aggregates are
+ configured in the OpenStack environment. To check this, run the following
+ command:
+
+ .. code-block:: console
+
+ # show configured host aggregates (example)
+ openstack aggregate list
+ +----+------+-------------------+
+ | ID | Name | Availability Zone |
+ +----+------+-------------------+
+ | 4 | agg0 | AZ_NAME_0 |
+ | 5 | agg1 | AZ_NAME_1 |
+ +----+------+-------------------+
+
+2. If no host aggregates are configured, please use `steps above`__ to
+ configure them.
+
+__ `Create a host aggregate`_
+
+
+3. Run the SampleVNF PROX scale-out test case, specifying the availability
+ zone of each VNF and traffic generator as a task arguments.
+
+ .. note:: The ``az_0`` and ``az_1`` should be changed according to the host
+ aggregates created in the OpenStack.
+
+ .. code-block:: console
+
+ yardstick -d task start\
+ <repo>/samples/vnf_samples/nsut/prox/tc_prox_heat_context_l2fwd_multiflow-2-scale-out.yaml\
+ --task-args='{
+ "num_vnfs": 4, "availability_zone": {
+ "vnf_0": "az_0", "tg_0": "az_1",
+ "vnf_1": "az_0", "tg_1": "az_1",
+ "vnf_2": "az_0", "tg_2": "az_1",
+ "vnf_3": "az_0", "tg_3": "az_1"
+ }
+ }'
+
+ ``num_vnfs`` specifies how many VNFs are going to be deployed in the
+ ``heat`` contexts. ``vnf_X`` and ``tg_X`` arguments configure the
+ availability zone where the VNF and traffic generator is going to be deployed.
+
+
Collectd KPIs
-------------
@@ -154,7 +264,7 @@ We set the VCPUs and memory using the ``--task-args`` options
.. code-block:: console
- yardstick task start --task-args='{"mem": 10480, "vcpus": 4, "ports": 2}' \
+ yardstick task start --task-args='{"mem": 10480, "vcpus": 4, "vports": 2}' \
samples/vnf_samples/nsut/vfw/tc_heat_rfc2544_ipv4_1rule_1flow_64B_trex_scale-up.yaml
In order to support ports scale-up, traffic and topology templates need to be used in testcase.
@@ -242,7 +352,7 @@ Baremetal
file: /etc/yardstick/nodes/pod.yaml
Scale-Out
---------------------
+---------
VNFs performance data with scale-out helps
@@ -313,3 +423,39 @@ options section.
options:
tg_0:
queues_per_port: 2
+
+
+Standalone configuration
+------------------------
+
+NSB supports certain Standalone deployment configurations.
+Standalone supports provisioning a VM in a standalone visualised environment using kvm/qemu.
+There two types of Standalone contexts available: OVS-DPDK and SRIOV.
+OVS-DPDK uses OVS network with DPDK drivers.
+SRIOV enables network traffic to bypass the software switch layer of the Hyper-V stack.
+
+Standalone with OVS-DPDK
+^^^^^^^^^^^^^^^^^^^^^^^^
+
+SampleVNF image is spawned in a VM on a baremetal server.
+OVS with DPDK is installed on the baremetal server.
+
+.. note:: Ubuntu 17.10 requires DPDK v.17.05 and higher, DPDK v.17.05 requires OVS v.2.8.0.
+
+Default values for OVS-DPDK:
+
+ * queues: 4
+ * lcore_mask: ""
+ * pmd_cpu_mask: "0x6"
+
+Sample test case file
+^^^^^^^^^^^^^^^^^^^^^
+
+ 1. Prepare SampleVNF image and copy it to ``flavor/images``.
+ 2. Prepare context files for TREX and SampleVNF under ``contexts/file``.
+ 3. Add bridge named ``br-int`` to the baremetal where SampleVNF image is deployed.
+ 4. Modify ``networks/phy_port`` accordingly to the baremetal setup.
+ 5. Run test from:
+
+.. literalinclude:: /submodules/yardstick/samples/vnf_samples/nsut/acl/tc_ovs_rfc2544_ipv4_1rule_1flow_64B_trex.yaml
+ :language: yaml
diff --git a/docs/testing/user/userguide/15-list-of-tcs.rst b/docs/testing/user/userguide/15-list-of-tcs.rst
index 678f0f9a9..37ce819f1 100644
--- a/docs/testing/user/userguide/15-list-of-tcs.rst
+++ b/docs/testing/user/userguide/15-list-of-tcs.rst
@@ -84,6 +84,8 @@ H A
opnfv_yardstick_tc057.rst
opnfv_yardstick_tc058.rst
opnfv_yardstick_tc087.rst
+ opnfv_yardstick_tc092.rst
+ opnfv_yardstick_tc093.rst
IPv6
----
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc092.rst b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst
new file mode 100644
index 000000000..895074a85
--- /dev/null
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst
@@ -0,0 +1,196 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International
+.. License.
+.. http://creativecommons.org/licenses/by/4.0
+.. (c) OPNFV, Ericsson and others.
+
+*************************************
+Yardstick Test Case Description TC092
+*************************************
+
++-----------------------------------------------------------------------------+
+|SDN Controller resilience in HA configuration |
+| |
++--------------+--------------------------------------------------------------+
+|test case id | OPNFV_YARDSTICK_TC092: SDN controller resilience and high |
+| | availability HA configuration |
+| | |
++--------------+--------------------------------------------------------------+
+|test purpose | This test validates SDN controller node high availability by |
+| | verifying there is no impact on the data plane connectivity |
+| | when one SDN controller fails in a HA configuration, |
+| | i.e. all existing configured network services DHCP, ARP, L2, |
+| | L3VPN, Security Groups should continue to operate |
+| | between the existing VMs while one SDN controller instance |
+| | is offline and rebooting. |
+| | |
+| | The test also validates that network service operations such |
+| | as creating a new VM in an existing or new L2 network |
+| | network remain operational while one instance of the |
+| | SDN controller is offline and recovers from the failure. |
+| | |
++--------------+--------------------------------------------------------------+
+|test method | This test case: |
+| | 1. fails one instance of a SDN controller cluster running |
+| | in a HA configuration on the OpenStack controller node |
+| | |
+| | 2. checks if already configured L2 connectivity between |
+| | existing VMs is not impacted |
+| | |
+| | 3. verifies that the system never loses the ability to |
+| | execute virtual network operations, even when the |
+| | failed SDN Controller is still recovering |
+| | |
++--------------+--------------------------------------------------------------+
+|attackers | In this test case, an attacker called “kill-process” is |
+| | needed. This attacker includes three parameters: |
+| | 1. ``fault_type``: which is used for finding the attacker's |
+| | scripts. It should be set to 'kill-process' in this test |
+| | |
+| | 2. ``process_name``: should be set to sdn controller |
+| | process |
+| | |
+| | 3. ``host``: which is the name of a control node where |
+| | opendaylight process is running |
+| | |
+| | example: |
+| | - ``fault_type``: “kill-process” |
+| | - ``process_name``: “opendaylight-karaf” (TBD) |
+| | - ``host``: node1 |
+| | |
++--------------+--------------------------------------------------------------+
+|monitors | In this test case, the following monitors are needed |
+| | 1. ``ping_same_network_l2``: monitor pinging traffic |
+| | between the VMs in same neutron network |
+| | |
+| | 2. ``ping_external_snat``: monitor ping traffic from VMs to |
+| | external destinations (e.g. google.com) |
+| | |
+| | 3. ``SDN controller process monitor``: a monitor checking |
+| | the state of a specified SDN controller process. It |
+| | measures the recovery time of the given process. |
+| | |
++--------------+--------------------------------------------------------------+
+|operations | In this test case, the following operations are needed: |
+| | 1. "nova-create-instance-in_network": create a VM instance |
+| | in one of the existing neutron network. |
+| | |
++--------------+--------------------------------------------------------------+
+|metrics | In this test case, there are two metrics: |
+| | 1. process_recover_time: which indicates the maximun |
+| | time (seconds) from the process being killed to |
+| | recovered |
+| | |
+| | 2. packet_drop: measure the packets that have been dropped |
+| | by the monitors using pktgen. |
+| | |
++--------------+--------------------------------------------------------------+
+|test tool | Developed by the project. Please see folder: |
+| | "yardstick/benchmark/scenarios/availability/ha_tools" |
+| | |
++--------------+--------------------------------------------------------------+
+|references | TBD |
+| | |
++--------------+--------------------------------------------------------------+
+|configuration | This test case needs two configuration files: |
+| | 1. test case file: opnfv_yardstick_tc092.yaml |
+| | - Attackers: see above “attackers” discription |
+| | - Monitors: see above “monitors” discription |
+| | - waiting_time: which is the time (seconds) from the |
+| | process being killed to stoping monitors the |
+| | monitors |
+| | - SLA: see above “metrics” discription |
+| | |
+| | 2. POD file: pod.yaml The POD configuration should record |
+| | on pod.yaml first. the “host” item in this test case |
+| | will use the node name in the pod.yaml. |
+| | |
++--------------+--------------------------------------------------------------+
+|test sequence | Description and expected result |
+| | |
++--------------+--------------------------------------------------------------+
+|pre-action | 1. The OpenStack cluster is set up with an SDN controller |
+| | running in a three node cluster configuration. |
+| | |
+| | 2. One or more neutron networks are created with two or |
+| | more VMs attached to each of the neutron networks. |
+| | |
+| | 3. The neutron networks are attached to a neutron router |
+| | which is attached to an external network the towards |
+| | DCGW. |
+| | |
+| | 4. The master node of SDN controller cluster is known. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 1 | Start ip connectivity monitors: |
+| | 1. Check the L2 connectivity between the VMs in the same |
+| | neutron network. |
+| | |
+| | 2. Check the external connectivity of the VMs. |
+| | |
+| | Each monitor runs in an independent process. |
+| | |
+| | Result: The monitor info will be collected. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 2 | Start attacker: |
+| | SSH to the VIM node and kill the SDN controller process |
+| | determined in step 2. |
+| | |
+| | Result: One SDN controller service will be shut down |
+| | |
++--------------+--------------------------------------------------------------+
+|step 3 | Restart the SDN controller. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 4 | Create a new VM in the existing Neutron network while the |
+| | SDN controller is offline or still recovering. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 5 | Stop IP connectivity monitors after a period of time |
+| | specified by “waiting_time” |
+| | |
+| | Result: The monitor info will be aggregated |
+| | |
++--------------+--------------------------------------------------------------+
+|step 6 | Verify the IP connectivity monitor result |
+| | |
+| | Result: IP connectivity monitor should not have any packet |
+| | drop failures reported |
+| | |
++--------------+--------------------------------------------------------------+
+|step 7 | Verify process_recover_time, which indicates the maximun |
+| | time (seconds) from the process being killed to recovered, |
+| | is within the SLA. This step blocks until either the |
+| | process has recovered or a timeout occurred. |
+| | |
+| | Result: process_recover_time is within SLA limits, if not, |
+| | test case failed and stopped. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 8 | Start IP connectivity monitors for the new VM: |
+| | 1. Check the L2 connectivity from the existing VMs to the |
+| | new VM in the Neutron network. |
+| | |
+| | 2. Check connectivity from one VM to an external host on |
+| | the Internet to verify SNAT functionality. |
+| | |
+| | Result: The monitor info will be collected. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 9 | Stop IP connectivity monitors after a period of time |
+| | specified by “waiting_time” |
+| | |
+| | Result: The monitor info will be aggregated |
+| | |
++--------------+--------------------------------------------------------------+
+|step 10 | Verify the IP connectivity monitor result |
+| | |
+| | Result: IP connectivity monitor should not have any packet |
+| | drop failures reported |
+| | |
++--------------+--------------------------------------------------------------+
+|test verdict | Fails only if SLA is not passed, or if there is a test case |
+| | execution problem. |
+| | |
++--------------+--------------------------------------------------------------+
+
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
new file mode 100644
index 000000000..31fa5d3d3
--- /dev/null
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
@@ -0,0 +1,184 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International
+.. License.
+.. http://creativecommons.org/licenses/by/4.0
+.. (c) OPNFV, Intracom Telecom and others.
+.. mardim@intracom-telecom.com
+
+*************************************
+Yardstick Test Case Description TC093
+*************************************
+
++-----------------------------------------------------------------------------+
+|SDN Vswitch resilience in non-HA or HA configuration |
+| |
++--------------+--------------------------------------------------------------+
+|test case id | OPNFV_YARDSTICK_TC093: SDN Vswitch resilience in |
+| | non-HA or HA configuration |
++--------------+--------------------------------------------------------------+
+|test purpose | This test validates that network data plane services are |
+| | resilient in the event of Virtual Switch failure |
+| | in compute nodes. Specifically, the test verifies that |
+| | existing data plane connectivity is not permanently impacted |
+| | i.e. all configured network services such as DHCP, ARP, L2, |
+| | L3 Security Groups continue to operate between the existing |
+| | VMs eventually after the Virtual Switches have finished |
+| | rebooting. |
+| | |
+| | The test also validates that new network service operations |
+| | (creating a new VM in the existing L2/L3 network or in a new |
+| | network, etc.) are operational after the Virtual Switches |
+| | have recovered from a failure. |
+| | |
++--------------+--------------------------------------------------------------+
+|test method | This testcase first checks if the already configured |
+| | DHCP/ARP/L2/L3/SNAT connectivity is proper. After |
+| | it fails and restarts again the VSwitch services which are |
+| | running on both OpenStack compute nodes, and then checks if |
+| | already configured DHCP/ARP/L2/L3/SNAT connectivity is not |
+| | permanently impacted (even if there are some packet |
+| | loss events) between VMs and the system is able to execute |
+| | new virtual network operations once the Vswitch services |
+| | are restarted and have been fully recovered |
+| | |
++--------------+--------------------------------------------------------------+
+|attackers | In this test case, two attackers called “kill-process” are |
+| | needed. These attackers include three parameters: |
+| | 1. fault_type: which is used for finding the attacker's |
+| | scripts. It should be set to 'kill-process' in this test |
+| | |
+| | 2. process_name: should be set to the name of the Vswitch |
+| | process |
+| | |
+| | 3. host: which is the name of the compute node where the |
+| | Vswitch process is running |
+| | |
+| | e.g. -fault_type: "kill-process" |
+| | -process_name: "openvswitch" |
+| | -host: node1 |
+| | |
++--------------+--------------------------------------------------------------+
+|monitors | This test case utilizes two monitors of type "ip-status" |
+| | and one monitor of type "process" to track the following |
+| | conditions: |
+| | 1. "ping_same_network_l2": monitor ICMP traffic between |
+| | VMs in the same Neutron network |
+| | |
+| | 2. "ping_external_snat": monitor ICMP traffic from VMs to |
+| | an external host on the Internet to verify SNAT |
+| | functionality. |
+| | |
+| | 3. "Vswitch process monitor": a monitor checking the |
+| | state of the specified Vswitch process. It measures |
+| | the recovery time of the given process. |
+| | |
+| | Monitors of type "ip-status" use the "ping" utility to |
+| | verify reachability of a given target IP. |
+| | |
++--------------+--------------------------------------------------------------+
+|operations | In this test case, the following operations are needed: |
+| | 1. "nova-create-instance-in_network": create a VM instance |
+| | in one of the existing Neutron network. |
+| | |
++--------------+--------------------------------------------------------------+
+|metrics | In this test case, there are two metrics: |
+| | 1. process_recover_time: which indicates the maximun |
+| | time (seconds) from the process being killed to |
+| | recovered |
+| | |
+| | 2. outage_time: measures the total time in which |
+| | monitors were failing in their tasks (e.g. total time of |
+| | Ping failure) |
+| | |
++--------------+--------------------------------------------------------------+
+|test tool | Developed by the project. Please see folder: |
+| | "yardstick/benchmark/scenarios/availability/ha_tools" |
+| | |
++--------------+--------------------------------------------------------------+
+|references | none |
+| | |
++--------------+--------------------------------------------------------------+
+|configuration | This test case needs two configuration files: |
+| | 1. test case file: opnfv_yardstick_tc093.yaml |
+| | - Attackers: see above “attackers” description |
+| | - monitor_time: which is the time (seconds) from |
+| | starting to stoping the monitors |
+| | - Monitors: see above “monitors” discription |
+| | - SLA: see above “metrics” description |
+| | |
+| | 2. POD file: pod.yaml The POD configuration should record |
+| | on pod.yaml first. the “host” item in this test case |
+| | will use the node name in the pod.yaml. |
+| | |
++--------------+--------------------------------------------------------------+
+|test sequence | Description and expected result |
+| | |
++--------------+--------------------------------------------------------------+
+|pre-action | 1. The Vswitches are set up in both compute nodes. |
+| | |
+| | 2. One or more Neutron networks are created with two or |
+| | more VMs attached to each of the Neutron networks. |
+| | |
+| | 3. The Neutron networks are attached to a Neutron router |
+| | which is attached to an external network towards the |
+| | DCGW. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 1 | Start IP connectivity monitors: |
+| | 1. Check the L2 connectivity between the VMs in the same |
+| | Neutron network. |
+| | |
+| | 2. Check connectivity from one VM to an external host on |
+| | the Internet to verify SNAT functionality. |
+| | |
+| | Result: The monitor info will be collected. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 2 | Start attackers: |
+| | SSH connect to the VIM compute nodes and kill the Vswitch |
+| | processes |
+| | |
+| | Result: the SDN Vswitch services will be shutdown |
+| | |
++--------------+--------------------------------------------------------------+
+|step 3 | Verify the results of the IP connectivity monitors. |
+| | |
+| | Result: The outage_time metric reported by the monitors |
+| | is not greater than the max_outage_time. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 4 | Restart the SDN Vswitch services. |
+| | |
++--------------+--------------------------------------------------------------+
+|step 5 | Create a new VM in the existing Neutron network |
+| | |
++--------------+--------------------------------------------------------------+
+|step 6 | Verify connectivity between VMs as follows: |
+| | 1. Check the L2 connectivity between the previously |
+| | existing VM and the newly created VM on the same |
+| | Neutron network by sending ICMP messages |
+| | |
++--------------+--------------------------------------------------------------+
+|step 7 | Stop IP connectivity monitors after a period of time |
+| | specified by “monitor_time” |
+| | |
+| | Result: The monitor info will be aggregated |
+| | |
++--------------+--------------------------------------------------------------+
+|step 8 | Verify the IP connectivity monitor results |
+| | |
+| | Result: IP connectivity monitor should not have any packet |
+| | drop failures reported |
+| | |
++--------------+--------------------------------------------------------------+
+|test verdict | This test fails if the SLAs are not met or if there is a |
+| | test case execution problem. The SLAs are define as follows |
+| | for this test: |
+| | * SDN Vswitch recovery |
+| | * process_recover_time <= 30 sec |
+| | |
+| | * no impact on data plane connectivity during SDN |
+| | Vswitch failure and recovery. |
+| | * packet_drop == 0 |
+| | |
++--------------+--------------------------------------------------------------+
+