aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--INFO2
-rw-r--r--api/server.py11
-rw-r--r--api/yardstick.ini2
-rw-r--r--docker/Dockerfile1
-rwxr-xr-xnsb_setup.sh244
-rw-r--r--requirements.txt3
-rwxr-xr-xrun_tests.sh26
-rw-r--r--samples/vnf_samples/nsut/2trex/tc_trex_baremetal_context.yaml43
-rw-r--r--samples/vnf_samples/nsut/2trex/trex_tg_topology.yaml50
-rw-r--r--samples/vnf_samples/nsut/ping/ping_tg_topology.yaml50
-rw-r--r--samples/vnf_samples/nsut/ping/tc_ping_baremetal_context.yaml41
-rw-r--r--samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml41
-rw-r--r--samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml41
-rw-r--r--samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_IMIX.yaml41
-rw-r--r--samples/vnf_samples/nsut/vpe/vpe_config/action_bulk_512.txt512
-rwxr-xr-xsamples/vnf_samples/nsut/vpe/vpe_config/full_tm_profile_10G.cfg105
-rw-r--r--samples/vnf_samples/nsut/vpe/vpe_config/fw_bulk_inst0_256.txt256
-rw-r--r--samples/vnf_samples/nsut/vpe/vpe_config/vpe_config101
-rw-r--r--samples/vnf_samples/nsut/vpe/vpe_config/vpe_script384
-rw-r--r--samples/vnf_samples/nsut/vpe/vpe_vnf_topology.yaml50
-rw-r--r--samples/vnf_samples/traffic_profiles/example.yaml198
-rw-r--r--samples/vnf_samples/traffic_profiles/fixed.yaml24
-rw-r--r--samples/vnf_samples/traffic_profiles/imix_storage.yaml41
-rw-r--r--samples/vnf_samples/traffic_profiles/imix_video.yaml43
-rw-r--r--samples/vnf_samples/traffic_profiles/imix_voice.yaml41
-rw-r--r--samples/vnf_samples/traffic_profiles/ipv4_1flow_Packets_vpe.yaml18
-rw-r--r--samples/vnf_samples/traffic_profiles/ipv4_throughput_vpe.yaml101
-rw-r--r--samples/vnf_samples/vnf_descriptors/tg_ping_tpl.yaml68
-rw-r--r--samples/vnf_samples/vnf_descriptors/tg_rfc2544_tpl.yaml69
-rw-r--r--samples/vnf_samples/vnf_descriptors/tg_trex_tpl.yaml75
-rw-r--r--samples/vnf_samples/vnf_descriptors/vpe_vnf.yaml66
-rw-r--r--tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-ha_daily.yaml54
-rw-r--r--tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-noha_daily.yaml46
-rw-r--r--tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-ha_daily.yaml54
-rw-r--r--tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-noha_daily.yaml46
-rw-r--r--tests/unit/benchmark/scenarios/networking/test_vnf_generic.py84
-rw-r--r--tests/unit/cmd/test_NSBperf.py118
-rw-r--r--tests/unit/network_services/traffic_profile/test_fixed.py179
-rw-r--r--tests/unit/network_services/traffic_profile/test_http.py45
-rw-r--r--tests/unit/network_services/traffic_profile/test_rfc2544.py247
-rw-r--r--tests/unit/network_services/traffic_profile/test_traffic_profile.py336
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml41
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/test_base.py2
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/test_tg_ping.py247
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/test_tg_rfc2544_trex.py406
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/test_tg_trex.py368
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/test_vpe_vnf.py347
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/vpe_config/action_bulk_512.txt512
-rwxr-xr-xtests/unit/network_services/vnf_generic/vnf/vpe_config/full_tm_profile_10G.cfg105
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/vpe_config/fw_bulk_inst0_256.txt256
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_config101
-rw-r--r--tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_script384
-rw-r--r--tox.ini1
-rwxr-xr-xyardstick/cmd/NSBperf.py217
-rw-r--r--yardstick/network_services/traffic_profile/fixed.py60
-rw-r--r--yardstick/network_services/traffic_profile/http.py33
-rw-r--r--yardstick/network_services/traffic_profile/rfc2544.py106
-rw-r--r--yardstick/network_services/traffic_profile/traffic_profile.py499
-rw-r--r--yardstick/network_services/vnf_generic/vnf/tg_ping.py167
-rw-r--r--yardstick/network_services/vnf_generic/vnf/tg_rfc2544_trex.py285
-rw-r--r--yardstick/network_services/vnf_generic/vnf/tg_trex.py278
-rw-r--r--yardstick/network_services/vnf_generic/vnf/vpe_vnf.py331
62 files changed, 8686 insertions, 17 deletions
diff --git a/INFO b/INFO
index 09c2b0a94..b1db82270 100644
--- a/INFO
+++ b/INFO
@@ -18,6 +18,8 @@ lvjing5@huawei.com
wu.zhihui1@zte.com.cn
14_ykl@tongji.edu.cn
limingjiang@huawei.com
+trevor.cooper@intel.com
+ross.b.brattain@intel.com
Link to TSC approval: http://meetbot.opnfv.org/meetings/
Link to approval of additional submitters:
diff --git a/api/server.py b/api/server.py
index be7963481..1d42feffb 100644
--- a/api/server.py
+++ b/api/server.py
@@ -10,7 +10,6 @@ from __future__ import absolute_import
import inspect
import logging
-from functools import reduce
from six.moves import filter
from flasgger import Swagger
@@ -38,6 +37,10 @@ def shutdown_session(exception=None):
db_session.remove()
+for u in urlpatterns:
+ api.add_resource(u.resource, u.url, endpoint=u.endpoint)
+
+
def init_db():
def func(a):
try:
@@ -52,8 +55,10 @@ def init_db():
Base.metadata.create_all(bind=engine)
-reduce(lambda a, b: a.add_resource(b.resource, b.url,
- endpoint=b.endpoint) or a, urlpatterns, api)
+def app_wrapper(*args, **kwargs):
+ init_db()
+ return app(*args, **kwargs)
+
if __name__ == '__main__':
_init_logging()
diff --git a/api/yardstick.ini b/api/yardstick.ini
index 2ba881fc1..d2e8956e2 100644
--- a/api/yardstick.ini
+++ b/api/yardstick.ini
@@ -9,7 +9,7 @@ threads = 5
async = true
max-requests = 5000
chmod-socket = 666
-callable = app
+callable = app_wrapper
enable-threads = true
close-on-exec = 1
daemonize= /var/log/yardstick/uwsgi.log
diff --git a/docker/Dockerfile b/docker/Dockerfile
index 23afef74e..afb2ce5c6 100644
--- a/docker/Dockerfile
+++ b/docker/Dockerfile
@@ -41,6 +41,7 @@ RUN apt-get update && apt-get install -y \
kpartx \
libffi-dev \
libssl-dev \
+ libzmq-dev \
python \
python-dev \
libxml2-dev \
diff --git a/nsb_setup.sh b/nsb_setup.sh
new file mode 100755
index 000000000..02258a577
--- /dev/null
+++ b/nsb_setup.sh
@@ -0,0 +1,244 @@
+#! /bin/bash
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+#
+# Change to yardstick directory ( <current-dir>/.. ), and export it as REPO_DIR
+#
+cd "$(dirname "${BASH_SOURCE[0]}")"
+export REPO_DIR=$PWD
+echo "------------------------------------------------------------------------------"
+echo " REPO_DIR exported as $REPO_DIR"
+echo "------------------------------------------------------------------------------"
+
+if [ "$(whoami)" != "root" ]; then
+ echo "Must be root to run $0"
+ exit 1;
+fi
+
+INSTALL_BIN_PATH="/opt/nsb_bin"
+TREX_DOWNLOAD="https://trex-tgn.cisco.com/trex/release/v2.05.tar.gz"
+DPDK_DOWNLOAD="http://dpdk.org/browse/dpdk/snapshot/dpdk-16.07.zip"
+VIRTUAL_VENV="$INSTALL_BIN_PATH/yardstick_venv"
+
+#
+# Install libs needed for NSB
+#
+install_libs()
+{
+ echo "Install libs needed to build and run NSB Testing..."
+ apt-get update > /dev/null 2>&1
+ pkg=(git build-essential python-dev virtualenv python-virtualenv virtualenv linux-headers-$(uname -r) unzip python-pip libpcap-dev)
+ for i in "${pkg[@]}"; do
+ dpkg-query -W --showformat='${Status}\n' "${i}"|grep "install ok installed"
+ if [ "$?" -eq "1" ]; then
+ apt-get -y install "${i}";
+ fi
+ done
+ echo "Done"
+}
+
+install_yardstick()
+{
+ echo "Create install directory... $INSTALL_BIN_PATH"
+ mkdir -p $INSTALL_BIN_PATH
+ echo "Install yardstick dependencies and build Yardstick in venv..."
+ pushd .
+ rm -rf $VIRTUAL_VENV
+ echo $VIRTUAL_VENV
+ virtualenv $VIRTUAL_VENV
+ if [ ! -f "$INSTALL_BIN_PATH/yardstick_venv/bin/activate" ]; then
+ echo "Installation Error. Failed to create yardstick virtual env..."
+ exit 1
+ fi
+ source $VIRTUAL_VENV/bin/activate
+ bash ./install.sh
+ python setup.py install
+ popd
+
+ pushd .
+ echo "Copying yardstick sample conf & pod file to /etc/yardstick/nodes"
+ mkdir -p /etc/yardstick/nodes
+ cp "$REPO_DIR/etc/yardstick/yardstick.conf.sample" "/etc/yardstick/yardstick.conf"
+ cp "$REPO_DIR/etc/yardstick/nodes/pod.yaml.nsb.sample" "/etc/yardstick/nodes/"
+ popd
+}
+
+#
+# Install trex for TH setup
+#
+install_trex()
+{
+ TREX_DIR=$INSTALL_BIN_PATH/trex/scripts
+ if [ -d "$TREX_DIR" ]; then
+ echo "Trex v2.05already installed. Make sure it contains PYTHONPATH which is required to run TRex"
+ else
+ echo "Build TRex and installing Trex TG in $INSTALL_BIN_PATH/trex"
+ rm -rf ${TREX_DOWNLOAD##*/}
+ if [ ! -e ${TREX_DOWNLOAD##*/} ] ; then
+ wget $TREX_DOWNLOAD
+ fi
+ tar zxvf ${TREX_DOWNLOAD##*/}
+ pushd .
+ rm -rf trex
+ mkdir -p trex
+ mv v2.05 trex/scripts
+ rm -rf v2.05.tar.gz
+ cd trex/scripts/ko/src/
+ make
+ make install
+ # workaround trex module issue
+ touch "$REPO_DIR/trex/scripts/automation/trex_control_plane/stl/__init__.py"
+ cp "$REPO_DIR/trex/scripts/dpdk_nic_bind.py" "$INSTALL_BIN_PATH"
+ popd
+ fi
+ echo "Done."
+}
+
+install_dpdk()
+{
+ if [ -d "$INSTALL_BIN_PATH/dpdk-16.07" ]; then
+ echo "DPDK already installed make sure.. igb_uio is loaded."
+ else
+ echo "Build DPDK 16.07..."
+ pushd .
+ rm -rf ${DPDK_DOWNLOAD##*/}
+ rm -rf "$REPO_DIR/dpdk-16.07/"
+ if [ ! -e ${DPDK_DOWNLOAD##*/} ] ; then
+ wget ${DPDK_DOWNLOAD}
+ fi
+ unzip -o ${DPDK_DOWNLOAD##*/}
+
+ cd dpdk-16.07
+ make config T=x86_64-native-linuxapp-gcc O=x86_64-native-linuxapp-gcc
+ cd x86_64-native-linuxapp-gcc
+ echo "Enable Port Stats..."
+ sed -i -e 's/CONFIG_RTE_PORT_STATS_COLLECT=n/CONFIG_RTE_PORT_STATS_COLLECT=y/g' .config
+ sed -i -e 's/CONFIG_RTE_PORT_PCAP=n/CONFIG_RTE_PORT_PCAP=y/g' .config
+ sed -i -e 's/CONFIG_RTE_TABLE_STATS_COLLECT=n/CONFIG_RTE_TABLE_STATS_COLLECT=y/g' .config
+ sed -i -e 's/CONFIG_RTE_PIPELINE_STATS_COLLECT=n/CONFIG_RTE_PIPELINE_STATS_COLLECT=y/g' .config
+ make
+
+ echo "Load DPDK modules and setup hugepages"
+ modprobe uio
+ mkdir -p "/lib/modules/$(uname -r)/extra"
+ cp -r "kmod/igb_uio.ko" "/lib/modules/$(uname -r)/extra"
+ depmod -a
+ modprobe igb_uio
+ sh -c "echo 'uio\nigb_uio\n' > /etc/modules-load.d/nsb.conf"
+
+ HUGEPGSZ=$(cat < /proc/meminfo | grep Hugepagesize | cut -d : -f 2 | tr -d ' ')
+ Pages=16
+ if [[ "$HUGEPGSZ" = "2048kB" ]] ; then
+ Pages=16384
+ fi
+ grep nr_hugepages /etc/sysctl.conf
+ if [[ "$?" -eq '1' ]] ; then
+ sh -c "echo 'vm.nr_hugepages=$Pages' >> /etc/sysctl.conf"
+ fi
+ echo "echo $Pages > /sys/kernel/mm/hugepages/hugepages-${HUGEPGSZ}/nr_hugepages" > .echo_tmp
+ echo "Reserving hugepages"
+ sudo sh .echo_tmp
+ rm -f .echo_tmp
+
+ service procps start
+ echo "Creating /mnt/huge and mounting as hugetlbfs"
+ sudo mkdir -p /mnt/huge
+
+ grep -s '/mnt/huge' /proc/mounts > /dev/null
+ if [ $? -ne 0 ] ; then
+ sudo mount -t hugetlbfs nodev /mnt/huge
+ fi
+ popd
+ mv "$REPO_DIR/dpdk-16.07" "$INSTALL_BIN_PATH"
+ rm dpdk-16.07.zip
+ fi
+ export RTE_SDK="$INSTALL_BIN_PATH/dpdk-16.07"
+ export RTE_TARGET=x86_64-native-linuxapp-gcc
+
+ if [ ! -f "$INSTALL_BIN_PATH/vPE_vnf" ]; then
+ pushd .
+ echo "Building vPE VNF..."
+ cd $INSTALL_BIN_PATH/dpdk-16.07/examples/ip_pipeline/
+ make clean
+ make
+ cp build/ip_pipeline $INSTALL_BIN_PATH/vPE_vnf
+ popd
+ fi
+ echo "Done"
+}
+
+
+push_nsb_binary()
+{
+ if [ ! -d "$INSTALL_BIN_PATH/trex" ]; then
+ cp -fr "$REPO_DIR/trex" "$INSTALL_BIN_PATH"
+ fi
+ rm -rf "$REPO_DIR/trex"
+
+ if [ -d "$INSTALL_BIN_PATH/trex" ]; then
+ echo "Setup Environment variables for Test Harness...."
+ PYTHONPATH="$INSTALL_BIN_PATH/trex/scripts/automation/trex_control_plane:$INSTALL_BIN_PATH/trex/scripts/automation/trex_control_plane/stl"
+ PY_PATH=$(grep PYTHONPATH ~/.bash_profile)
+ if [ "$PY_PATH" = "" ] ; then
+ sh -c "echo export PYTHONPATH=$PYTHONPATH >> ~/.bash_profile" > /dev/null
+ else
+ echo "Your ~/.bash_profile already contains a PYTHONPATH definition."
+ echo "Make sure it contains $PYTHONPATH which is required to run TRex"
+ fi
+ fi
+ cp "$REPO_DIR/yardstick/network_services/nfvi/collectd.sh" "$INSTALL_BIN_PATH"
+ cp "$REPO_DIR/yardstick/network_services/nfvi/collectd.conf" "$INSTALL_BIN_PATH"
+ cp "$REPO_DIR/nsb_setup.sh" "$INSTALL_BIN_PATH"
+ echo "Done"
+}
+
+check_installed_files()
+{
+ if [ ! -f "$INSTALL_BIN_PATH/yardstick_venv/bin/activate" ]; then
+ echo "Installation Error. Failed to create yardstick virtual env..."
+ exit 1
+ fi
+
+ if [ ! -d "$INSTALL_BIN_PATH/dpdk-16.07" ]; then
+ echo "Installation Error. Failed to download and install dpdk-16.07..."
+ exit 1
+ fi
+
+ if [ ! -d "$INSTALL_BIN_PATH/trex" ]; then
+ echo "Installation Error. Failed to download and configure Trex"
+ exit 1
+ fi
+
+ if [ ! -f "$INSTALL_BIN_PATH/vPE_vnf" ]; then
+ echo "Installation Error. vPE VNF not present in install dir $INSTALL_BIN_PATH"
+ exit 1
+ fi
+}
+
+if [ "$1" == "dpdk" ]; then
+ install_libs
+ install_dpdk
+else
+ install_libs
+ install_yardstick
+ install_dpdk
+ install_trex
+ push_nsb_binary
+ check_installed_files
+clear
+echo "Installation completed..."
+echo "Virtual Environment : $INSTALL_BIN_PATH/yardstick_venv"
+echo "Please Refer README.NSB.rst document on how to get started on VNF testing."
+fi
diff --git a/requirements.txt b/requirements.txt
index 107e8dee4..d04824686 100644
--- a/requirements.txt
+++ b/requirements.txt
@@ -87,5 +87,6 @@ docker-py==1.10.6
flasgger==0.5.13
flask-restful-swagger==0.19
SQLAlchemy==1.1.4
-zmq==0.0.0
+# version 14.5.0 for compatibility with trex traffic generator
+pyzmq==14.5.0
pika==0.10.0
diff --git a/run_tests.sh b/run_tests.sh
index 972f6a27f..1f985b6c1 100755
--- a/run_tests.sh
+++ b/run_tests.sh
@@ -33,7 +33,33 @@ run_flake8() {
fi
}
+get_external_libs() {
+ cd $(dirname ${BASH_SOURCE[0]})
+ TREX_DOWNLOAD="https://trex-tgn.cisco.com/trex/release/v2.05.tar.gz"
+ TREX_DIR=$PWD/trex/scripts
+ if [ ! -d "$TREX_DIR" ]; then
+ rm -rf ${TREX_DOWNLOAD##*/}
+ if [ ! -e ${TREX_DOWNLOAD##*/} ] ; then
+ wget -nv $TREX_DOWNLOAD
+ fi
+ tar xf ${TREX_DOWNLOAD##*/}
+ pushd .
+ rm -rf trex && mkdir -p trex
+ mv v2.05 trex/scripts
+ rm -rf v2.05.tar.gz
+ touch "$PWD/trex/scripts/automation/trex_control_plane/stl/__init__.py"
+ popd
+ fi
+ echo "Done."
+ export PYTHONPATH=$PYTHONPATH:"$PWD/trex/scripts/automation/trex_control_plane"
+ export PYTHONPATH=$PYTHONPATH:"$PWD/trex/scripts/automation/trex_control_plane/stl"
+ echo $PYTHONPATH
+}
+
run_tests() {
+ echo "Get external libs needed for unit test"
+ get_external_libs
+
echo "Running unittest ... "
if [ $FILE_OPTION == "f" ]; then
python -m unittest discover -v -s tests/unit > $logfile 2>&1
diff --git a/samples/vnf_samples/nsut/2trex/tc_trex_baremetal_context.yaml b/samples/vnf_samples/nsut/2trex/tc_trex_baremetal_context.yaml
new file mode 100644
index 000000000..e0ba6d96f
--- /dev/null
+++ b/samples/vnf_samples/nsut/2trex/tc_trex_baremetal_context.yaml
@@ -0,0 +1,43 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: "yardstick:task:0.1"
+
+scenarios:
+-
+ type: NSPerf
+ traffic_profile: ../../traffic_profiles/fixed.yaml
+ topology: trex_tg_topology.yaml # TODO: look in relative path where the tc.yaml is found
+
+ nodes: # This section is copied from pod.xml or resolved via Heat
+ trexgen__1: trafficgen_1.yardstick
+ trexvnf__1: vnf.yardstick
+
+ vnf_options:
+ trexgen__1:
+ target_ip: trexvnf__1.xe0.local_ip # TODO: resolve to config vars
+ trexvnf__1:
+ target_ip: trexgen__1.xe1.local_ip # TODO: resolve to config vars
+ runner:
+ type: Duration
+ duration: 10
+
+context:
+ type: Node # Heat, Node(baremetal), Node-ovs, Node-sriov
+ name: yardstick
+ #file: pod.yaml
+ # image: yardstick-baremetal # only important for heat context
+ nfvi_type: baremetal # options: baremetal, sriov, ovs-virtio TODO: what about mixed scenarios?
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/samples/vnf_samples/nsut/2trex/trex_tg_topology.yaml b/samples/vnf_samples/nsut/2trex/trex_tg_topology.yaml
new file mode 100644
index 000000000..1a9b50c84
--- /dev/null
+++ b/samples/vnf_samples/nsut/2trex/trex_tg_topology.yaml
@@ -0,0 +1,50 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+nsd:nsd-catalog:
+ nsd:
+ - id: trex-tg-topology
+ name: trex-tg-topology
+ short-name: trex-tg-topology
+ description: trex-tg-topology
+ constituent-vnfd:
+ - member-vnf-index: '1'
+ vnfd-id-ref: trexgen__1
+ VNF model: ../../vnf_descriptors/tg_trex_tpl.yaml #VNF type
+ - member-vnf-index: '2'
+ vnfd-id-ref: trexvnf__1
+ VNF model: ../../vnf_descriptors/tg_trex_tpl.yaml #VNF type
+
+ vld:
+ - id: private
+ name: trexgen__1 to trexvnf__1 link 1
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: trexgen
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: trexgen
+
+ - id: public
+ name: trexvnf__1 to trexgen__1 link 2
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: trexgen
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: trexgen
diff --git a/samples/vnf_samples/nsut/ping/ping_tg_topology.yaml b/samples/vnf_samples/nsut/ping/ping_tg_topology.yaml
new file mode 100644
index 000000000..b2b852a79
--- /dev/null
+++ b/samples/vnf_samples/nsut/ping/ping_tg_topology.yaml
@@ -0,0 +1,50 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+nsd:nsd-catalog:
+ nsd:
+ - id: ping-tg-topology
+ name: ping-tg-topology
+ short-name: ping-tg-topology
+ description: ping-tg-topology
+ constituent-vnfd:
+ - member-vnf-index: '1'
+ vnfd-id-ref: tg__1
+ VNF model: ../../vnf_descriptors/tg_ping_tpl.yaml #VNF type
+ - member-vnf-index: '2'
+ vnfd-id-ref: vnf__1
+ VNF model: ../../vnf_descriptors/tg_ping_tpl.yaml #VNF type
+
+ vld:
+ - id: private
+ name: tg__1 to vnf__1 link 1
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: trexgen
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: trexgen
+
+ - id: public
+ name: vnf__1 to tg__1 link 2
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: trexgen
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: trexgen
diff --git a/samples/vnf_samples/nsut/ping/tc_ping_baremetal_context.yaml b/samples/vnf_samples/nsut/ping/tc_ping_baremetal_context.yaml
new file mode 100644
index 000000000..5f2c55b81
--- /dev/null
+++ b/samples/vnf_samples/nsut/ping/tc_ping_baremetal_context.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: "yardstick:task:0.1"
+
+scenarios:
+-
+ type: NSPerf
+ traffic_profile: ../../traffic_profiles/fixed.yaml
+ topology: ping_tg_topology.yaml # TODO: look in relative path where the tc.yaml is found
+
+ nodes: # This section is copied from pod.xml or resolved via Heat
+ tg__1: trafficgen_1.yardstick
+ vnf__1: vnf.yardstick
+
+ vnf_options:
+ tg__1:
+ target_ip: pingvnf__1.xe0.local_ip # TODO: resolve to config vars
+ vnf__1:
+ target_ip: pinggen__1.xe1.local_ip # TODO: resolve to config vars
+ runner:
+ type: Duration
+ duration: 10
+
+context:
+ type: Node
+ name: yardstick
+ nfvi_type: baremetal
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml
new file mode 100644
index 000000000..37687613c
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: yardstick:task:0.1
+scenarios:
+- type: NSPerf
+ traffic_profile: "../../traffic_profiles/ipv4_throughput_vpe.yaml"
+ topology: vpe_vnf_topology.yaml
+ nodes:
+ tg__1: trafficgen_1.yardstick
+ vnf__1: vnf.yardstick
+ tc_options:
+ rfc2544:
+ allowed_drop_rate: 0.8 - 1
+ vnf_options:
+ vpe:
+ cfg: vpe_config
+ runner:
+ type: Duration
+ duration: 400
+ interval: 35
+ traffic_options:
+ flow: "../../traffic_profiles/ipv4_1flow_Packets_vpe.yaml"
+ imix: "../../traffic_profiles/imix_storage.yaml"
+context:
+ type: Node
+ name: yardstick
+ nfvi_type: baremetal
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml
new file mode 100644
index 000000000..fb1be35c1
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: yardstick:task:0.1
+scenarios:
+- type: NSPerf
+ traffic_profile: "../../traffic_profiles/ipv4_throughput_vpe.yaml"
+ topology: vpe_vnf_topology.yaml
+ nodes:
+ tg__1: trafficgen_1.yardstick
+ vnf__1: vnf.yardstick
+ tc_options:
+ rfc2544:
+ allowed_drop_rate: 0.8 - 1
+ vnf_options:
+ vpe:
+ cfg: vpe_config
+ runner:
+ type: Duration
+ duration: 400
+ interval: 35
+ traffic_options:
+ flow: "../../traffic_profiles/ipv4_1flow_Packets_vpe.yaml"
+ imix: "../../traffic_profiles/imix_voice.yaml"
+context:
+ type: Node
+ name: yardstick
+ nfvi_type: baremetal
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_IMIX.yaml b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_IMIX.yaml
new file mode 100644
index 000000000..c481f812b
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/tc_baremetal_rfc2544_ipv4_1flow_IMIX.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: yardstick:task:0.1
+scenarios:
+- type: NSPerf
+ traffic_profile: "../../traffic_profiles/ipv4_throughput_vpe.yaml"
+ topology: vpe_vnf_topology.yaml
+ nodes:
+ tg__1: trafficgen_1.yardstick
+ vnf__1: vnf.yardstick
+ tc_options:
+ rfc2544:
+ allowed_drop_rate: 0.8 - 1
+ vnf_options:
+ vpe:
+ cfg: vpe_config
+ runner:
+ type: Duration
+ duration: 400
+ interval: 35
+ traffic_options:
+ flow: "../../traffic_profiles/ipv4_1flow_Packets_vpe.yaml"
+ imix: "../../traffic_profiles/imix_video.yaml"
+context:
+ type: Node
+ name: yardstick
+ nfvi_type: baremetal
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/samples/vnf_samples/nsut/vpe/vpe_config/action_bulk_512.txt b/samples/vnf_samples/nsut/vpe/vpe_config/action_bulk_512.txt
new file mode 100644
index 000000000..21731cd45
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_config/action_bulk_512.txt
@@ -0,0 +1,512 @@
+flow 0 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 1 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 2 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 3 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 4 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 5 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 6 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 7 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 8 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 9 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 10 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 11 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 12 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 13 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 14 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 15 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 16 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 17 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 18 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 19 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 20 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 21 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 22 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 23 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 24 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 25 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 26 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 27 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 28 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 29 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 30 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 31 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 32 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 33 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 34 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 35 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 36 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 37 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 38 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 39 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 40 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 41 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 42 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 43 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 44 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 45 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 46 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 47 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 48 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 49 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 50 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 51 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 52 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 53 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 54 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 55 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 56 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 57 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 58 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 59 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 60 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 61 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 62 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 63 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 64 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 65 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 66 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 67 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 68 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 69 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 70 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 71 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 72 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 73 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 74 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 75 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 76 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 77 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 78 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 79 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 80 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 81 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 82 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 83 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 84 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 85 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 86 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 87 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 88 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 89 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 90 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 91 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 92 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 93 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 94 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 95 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 96 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 97 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 98 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 99 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 100 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 101 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 102 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 103 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 104 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 105 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 106 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 107 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 108 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 109 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 110 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 111 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 112 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 113 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 114 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 115 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 116 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 117 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 118 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 119 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 120 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 121 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 122 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 123 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 124 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 125 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 126 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 127 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 128 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 129 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 130 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 131 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 132 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 133 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 134 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 135 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 136 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 137 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 138 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 139 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 140 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 141 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 142 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 143 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 144 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 145 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 146 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 147 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 148 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 149 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 150 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 151 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 152 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 153 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 154 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 155 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 156 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 157 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 158 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 159 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 160 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 161 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 162 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 163 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 164 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 165 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 166 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 167 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 168 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 169 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 170 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 171 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 172 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 173 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 174 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 175 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 176 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 177 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 178 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 179 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 180 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 181 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 182 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 183 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 184 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 185 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 186 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 187 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 188 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 189 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 190 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 191 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 192 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 193 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 194 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 195 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 196 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 197 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 198 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 199 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 200 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 201 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 202 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 203 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 204 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 205 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 206 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 207 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 208 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 209 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 210 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 211 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 212 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 213 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 214 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 215 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 216 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 217 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 218 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 219 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 220 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 221 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 222 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 223 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 224 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 225 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 226 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 227 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 228 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 229 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 230 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 231 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 232 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 233 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 234 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 235 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 236 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 237 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 238 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 239 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 240 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 241 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 242 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 243 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 244 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 245 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 246 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 247 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 248 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 249 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 250 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 251 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 252 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 253 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 254 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 255 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 256 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 257 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 258 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 259 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 260 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 261 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 262 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 263 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 264 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 265 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 266 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 267 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 268 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 269 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 270 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 271 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 272 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 273 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 274 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 275 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 276 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 277 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 278 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 279 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 280 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 281 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 282 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 283 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 284 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 285 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 286 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 287 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 288 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 289 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 290 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 291 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 292 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 293 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 294 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 295 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 296 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 297 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 298 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 299 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 300 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 301 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 302 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 303 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 304 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 305 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 306 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 307 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 308 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 309 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 310 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 311 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 312 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 313 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 314 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 315 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 316 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 317 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 318 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 319 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 320 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 321 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 322 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 323 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 324 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 325 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 326 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 327 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 328 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 329 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 330 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 331 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 332 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 333 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 334 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 335 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 336 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 337 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 338 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 339 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 340 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 341 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 342 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 343 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 344 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 345 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 346 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 347 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 348 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 349 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 350 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 351 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 352 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 353 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 354 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 355 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 356 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 357 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 358 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 359 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 360 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 361 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 362 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 363 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 364 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 365 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 366 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 367 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 368 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 369 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 370 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 371 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 372 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 373 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 374 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 375 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 376 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 377 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 378 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 379 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 380 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 381 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 382 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 383 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 384 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 385 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 386 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 387 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 388 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 389 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 390 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 391 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 392 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 393 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 394 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 395 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 396 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 397 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 398 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 399 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 400 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 401 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 402 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 403 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 404 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 405 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 406 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 407 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 408 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 409 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 410 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 411 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 412 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 413 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 414 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 415 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 416 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 417 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 418 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 419 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 420 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 421 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 422 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 423 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 424 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 425 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 426 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 427 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 428 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 429 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 430 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 431 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 432 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 433 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 434 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 435 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 436 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 437 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 438 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 439 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 440 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 441 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 442 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 443 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 444 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 445 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 446 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 447 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 448 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 449 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 450 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 451 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 452 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 453 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 454 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 455 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 456 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 457 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 458 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 459 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 460 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 461 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 462 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 463 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 464 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 465 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 466 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 467 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 468 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 469 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 470 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 471 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 472 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 473 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 474 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 475 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 476 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 477 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 478 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 479 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 480 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 481 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 482 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 483 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 484 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 485 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 486 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 487 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 488 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 489 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 490 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 491 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 492 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 493 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 494 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 495 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 496 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 497 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 498 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 499 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 500 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 501 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 502 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 503 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 504 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 505 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 506 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 507 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 508 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 509 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 510 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 511 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
diff --git a/samples/vnf_samples/nsut/vpe/vpe_config/full_tm_profile_10G.cfg b/samples/vnf_samples/nsut/vpe/vpe_config/full_tm_profile_10G.cfg
new file mode 100755
index 000000000..502655fd0
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_config/full_tm_profile_10G.cfg
@@ -0,0 +1,105 @@
+; BSD LICENSE
+;
+; Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
+; All rights reserved.
+;
+; Redistribution and use in source and binary forms, with or without
+; modification, are permitted provided that the following conditions
+; are met:
+;
+; * Redistributions of source code must retain the above copyright
+; notice, this list of conditions and the following disclaimer.
+; * Redistributions in binary form must reproduce the above copyright
+; notice, this list of conditions and the following disclaimer in
+; the documentation and/or other materials provided with the
+; distribution.
+; * Neither the name of Intel Corporation nor the names of its
+; contributors may be used to endorse or promote products derived
+; from this software without specific prior written permission.
+;
+; THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+; "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+; LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
+; A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
+; OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
+; SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
+; LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
+; DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
+; THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
+; (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
+; OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+
+; This file enables the following hierarchical scheduler configuration for each
+; 10GbE output port:
+; * Single subport (subport 0):
+; - Subport rate set to 100% of port rate
+; - Each of the 4 traffic classes has rate set to 100% of port rate
+; * 4K pipes per subport 0 (pipes 0 .. 4095) with identical configuration:
+; - Pipe rate set to 1/4K of port rate
+; - Each of the 4 traffic classes has rate set to 100% of pipe rate
+; - Within each traffic class, the byte-level WRR weights for the 4 queues
+; are set to 1:1:1:1
+;
+; For more details, please refer to chapter "Quality of Service (QoS) Framework"
+; of Intel Data Plane Development Kit (Intel DPDK) Programmer's Guide.
+
+; Port configuration
+[port]
+frame overhead = 24 ; frame overhead = Preamble (7) + SFD (1) + FCS (4) + IFG (12)
+mtu = 1522; mtu = Q-in-Q MTU (FCS not included)
+number of subports per port = 1
+number of pipes per subport = 4096
+queue sizes = 64 64 64 64
+
+; Subport configuration
+[subport 0]
+tb rate = 1250000000 ; Bytes per second
+tb size = 1000000 ; Bytes
+
+tc 0 rate = 1250000000 ; Bytes per second
+tc 1 rate = 1250000000 ; Bytes per second
+tc 2 rate = 1250000000 ; Bytes per second
+tc 3 rate = 1250000000 ; Bytes per second
+tc period = 10 ; Milliseconds
+
+pipe 0-4095 = 0 ; These pipes are configured with pipe profile 0
+
+; Pipe configuration
+[pipe profile 0]
+tb rate = 1250000000 ; Bytes per second
+tb size = 1000000 ; Bytes
+
+tc 0 rate = 1250000000 ; Bytes per second
+tc 1 rate = 1250000000 ; Bytes per second
+tc 2 rate = 1250000000 ; Bytes per second
+tc 3 rate = 1250000000 ; Bytes per second
+tc period = 40 ; Milliseconds
+
+tc 3 oversubscription weight = 1
+
+tc 0 wrr weights = 1 1 1 1
+tc 1 wrr weights = 1 1 1 1
+tc 2 wrr weights = 1 1 1 1
+tc 3 wrr weights = 1 1 1 1
+
+; RED params per traffic class and color (Green / Yellow / Red)
+[red]
+tc 0 wred min = 48 40 32
+tc 0 wred max = 64 64 64
+tc 0 wred inv prob = 10 10 10
+tc 0 wred weight = 9 9 9
+
+tc 1 wred min = 48 40 32
+tc 1 wred max = 64 64 64
+tc 1 wred inv prob = 10 10 10
+tc 1 wred weight = 9 9 9
+
+tc 2 wred min = 48 40 32
+tc 2 wred max = 64 64 64
+tc 2 wred inv prob = 10 10 10
+tc 2 wred weight = 9 9 9
+
+tc 3 wred min = 48 40 32
+tc 3 wred max = 64 64 64
+tc 3 wred inv prob = 10 10 10
+tc 3 wred weight = 9 9 9
diff --git a/samples/vnf_samples/nsut/vpe/vpe_config/fw_bulk_inst0_256.txt b/samples/vnf_samples/nsut/vpe/vpe_config/fw_bulk_inst0_256.txt
new file mode 100644
index 000000000..307150789
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_config/fw_bulk_inst0_256.txt
@@ -0,0 +1,256 @@
+priority 1 ipv4 152.16.0.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.1.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.2.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.3.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.4.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.5.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.6.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.7.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.8.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.9.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.10.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.11.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.12.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.13.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.14.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.15.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.16.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.17.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.18.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.19.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.20.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.21.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.22.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.23.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.24.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.25.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.26.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.27.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.28.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.29.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.30.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.31.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.32.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.33.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.34.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.35.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.36.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.37.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.38.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.39.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.40.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.41.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.42.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.43.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.44.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.45.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.46.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.47.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.48.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.49.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.50.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.51.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.52.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.53.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.54.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.55.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.56.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.57.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.58.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.59.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.60.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.61.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.62.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.63.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.64.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.65.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.66.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.67.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.68.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.69.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.70.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.71.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.72.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.73.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.74.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.75.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.76.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.77.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.78.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.79.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.80.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.81.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.82.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.83.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.84.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.85.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.86.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.87.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.88.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.89.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.90.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.91.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.92.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.93.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.94.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.95.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.96.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.97.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.98.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.99.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.100.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.101.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.102.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.103.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.104.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.105.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.106.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.107.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.108.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.109.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.110.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.111.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.112.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.113.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.114.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.115.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.116.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.117.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.118.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.119.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.120.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.121.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.122.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.123.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.124.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.125.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.126.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.127.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.128.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.129.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.130.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.131.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.132.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.133.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.134.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.135.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.136.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.137.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.138.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.139.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.140.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.141.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.142.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.143.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.144.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.145.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.146.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.147.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.148.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.149.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.150.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.151.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.152.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.153.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.154.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.155.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.156.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.157.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.158.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.159.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.160.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.161.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.162.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.163.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.164.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.165.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.166.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.167.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.168.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.169.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.170.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.171.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.172.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.173.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.174.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.175.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.176.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.177.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.178.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.179.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.180.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.181.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.182.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.183.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.184.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.185.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.186.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.187.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.188.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.189.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.190.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.191.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.192.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.193.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.194.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.195.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.196.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.197.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.198.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.199.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.200.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.201.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.202.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.203.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.204.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.205.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.206.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.207.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.208.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.209.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.210.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.211.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.212.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.213.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.214.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.215.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.216.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.217.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.218.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.219.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.220.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.221.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.222.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.223.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.224.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.225.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.226.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.227.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.228.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.229.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.230.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.231.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.232.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.233.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.234.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.235.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.236.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.237.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.238.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.239.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.240.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.241.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.242.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.243.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.244.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.245.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.246.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.247.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.248.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.249.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.250.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.251.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.252.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.253.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.254.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.255.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
diff --git a/samples/vnf_samples/nsut/vpe/vpe_config/vpe_config b/samples/vnf_samples/nsut/vpe/vpe_config/vpe_config
new file mode 100644
index 000000000..17ebc6a76
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_config/vpe_config
@@ -0,0 +1,101 @@
+[EAL]
+log_level = 0
+
+[PIPELINE0]
+type = MASTER
+core = s{socket}c0
+
+[MEMPOOL0]
+pool_size = 256K
+
+[MEMPOOL1]
+pool_size = 2M
+
+[RXQ1.0]
+mempool = MEMPOOL1
+
+;;;;;;;;;;Begin of upstream 0;;;;;;;;;;;;;;;;;;
+[PIPELINE1]
+type = FIREWALL
+core = s{socket}c1
+pktq_in = RXQ0.0
+pktq_out = SWQ0 SINK0
+n_rules = 4096
+pkt_type = qinq_ipv4
+
+[PIPELINE2]
+type = FLOW_CLASSIFICATION
+core = s{socket}c1
+pktq_in = SWQ0
+pktq_out = SWQ1 SINK1
+n_flows = 65536
+key_size = 8; dma_size
+key_offset = 268; dma_dst_offset
+key_mask = 00000FFF00000FFF; qinq
+flowid_offset = 172; mbuf (128) + 64
+
+[PIPELINE3]
+type = FLOW_ACTIONS
+core = s{socket}c1h
+pktq_in = SWQ1
+pktq_out = SWQ2
+n_flows = 65536
+n_meters_per_flow = 1;dscp is not considered for per user metering
+flow_id_offset = 172; mbuf (128) + 64
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+[PIPELINE4]
+type = FLOW_ACTIONS
+core = s{socket}c1h
+pktq_in = SWQ2
+pktq_out = SWQ3
+n_flows = 65536
+n_meters_per_flow = 4; Use dscp to classify into 1 out of 4 TC
+flow_id_offset = 172; mbuf (128) + 64
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+[PIPELINE5]
+type = ROUTING
+core = s{socket}c1
+pktq_in = SWQ3
+pktq_out = TXQ1.0 SINK2
+encap = ethernet_mpls
+mpls_color_mark = yes
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+;;;;;;;;;;Begin of downstream 0;;;;;;;;;;;;;;;;;;
+[PIPELINE6]
+type = ROUTING
+core = s{socket}c2
+pktq_in = RXQ1.0
+pktq_out = SWQ4 SINK3
+encap = ethernet_qinq
+qinq_sched = yes
+ip_hdr_offset = 270; mbuf (128) + headroom (128) + ethernet header (14) = 270
+
+
+[PIPELINE7]
+type = PASS-THROUGH
+core = s{socket}c2h
+pktq_in = SWQ4
+pktq_out = SWQ5
+
+[PIPELINE8]
+type = PASS-THROUGH
+core = s{socket}c2h
+pktq_in = SWQ5 TM0
+pktq_out = TM0 SWQ6
+
+[PIPELINE9]
+type = PASS-THROUGH
+core = s{socket}c2
+pktq_in = SWQ6
+pktq_out = TXQ0.0
+
+[TM0]
+burst_read = 24;dequeue should be slightly slower then enqueue to create buffer
+burst_write = 32
+cfg = /tmp/full_tm_profile_10G.cfg
diff --git a/samples/vnf_samples/nsut/vpe/vpe_config/vpe_script b/samples/vnf_samples/nsut/vpe/vpe_config/vpe_script
new file mode 100644
index 000000000..740eb6586
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_config/vpe_script
@@ -0,0 +1,384 @@
+#=================================================================
+#Pipeline 1 : 256 Firewall Rules for 1 port with 0.0.X.0/24 for destination IP
+#=================================================================
+p 1 firewall add bulk /tmp/fw_bulk_inst0_256.txt
+p 1 firewall add default 1
+
+#=================================================================
+#Pipeline 2 : 512 flow classfication Rules for 1 port using QinQ as input. Flow id = SVLAN * 512 + CVLAN
+#=================================================================
+p 2 flow add qinq 128 512 port 0 id 1
+p 2 flow add default 1
+
+#=================================================================
+#Pipeline 3 : 512 metering Rules for 1 port
+#=================================================================
+p 3 action flow bulk /tmp/action_bulk_512.txt
+p 3 flows 512 ports 1
+
+#=================================================================
+#Pipeline 4 : 512 metering Rules and 4 traffic classes for 1 port
+#=================================================================
+p 4 action flow bulk /tmp/action_bulk_512.txt
+p 4 flows 512 ports 1
+p 4 action dscp 0 class 0 color G
+p 4 action dscp 1 class 1 color Y
+p 4 action dscp 2 class 2 color R
+p 4 action dscp 3 class 3 color G
+p 4 action dscp 4 class 0 color Y
+p 4 action dscp 5 class 1 color R
+p 4 action dscp 6 class 2 color G
+p 4 action dscp 7 class 3 color Y
+p 4 action dscp 8 class 0 color R
+p 4 action dscp 9 class 1 color G
+p 4 action dscp 10 class 2 color Y
+p 4 action dscp 11 class 3 color R
+p 4 action dscp 12 class 0 color G
+p 4 action dscp 13 class 1 color Y
+p 4 action dscp 14 class 2 color R
+p 4 action dscp 15 class 3 color G
+p 4 action dscp 16 class 0 color Y
+p 4 action dscp 17 class 1 color R
+p 4 action dscp 18 class 2 color G
+p 4 action dscp 19 class 3 color Y
+p 4 action dscp 20 class 0 color R
+p 4 action dscp 21 class 1 color G
+p 4 action dscp 22 class 2 color Y
+p 4 action dscp 23 class 3 color R
+p 4 action dscp 24 class 0 color G
+p 4 action dscp 25 class 1 color Y
+p 4 action dscp 26 class 2 color R
+p 4 action dscp 27 class 3 color G
+p 4 action dscp 28 class 0 color Y
+p 4 action dscp 29 class 1 color R
+p 4 action dscp 30 class 2 color G
+p 4 action dscp 31 class 3 color Y
+p 4 action dscp 32 class 0 color R
+p 4 action dscp 33 class 1 color G
+p 4 action dscp 34 class 2 color Y
+p 4 action dscp 35 class 3 color R
+p 4 action dscp 36 class 0 color G
+p 4 action dscp 37 class 1 color Y
+p 4 action dscp 38 class 2 color R
+p 4 action dscp 39 class 3 color G
+p 4 action dscp 40 class 0 color Y
+p 4 action dscp 41 class 1 color R
+p 4 action dscp 42 class 2 color G
+p 4 action dscp 43 class 3 color Y
+p 4 action dscp 44 class 0 color R
+p 4 action dscp 45 class 1 color G
+p 4 action dscp 46 class 2 color Y
+p 4 action dscp 47 class 3 color R
+p 4 action dscp 48 class 0 color G
+p 4 action dscp 49 class 1 color Y
+p 4 action dscp 50 class 2 color R
+p 4 action dscp 51 class 3 color G
+p 4 action dscp 52 class 0 color Y
+p 4 action dscp 53 class 1 color R
+p 4 action dscp 54 class 2 color G
+p 4 action dscp 55 class 3 color Y
+p 4 action dscp 56 class 0 color R
+p 4 action dscp 57 class 1 color G
+p 4 action dscp 58 class 2 color Y
+p 4 action dscp 59 class 3 color R
+p 4 action dscp 60 class 0 color G
+p 4 action dscp 61 class 1 color Y
+p 4 action dscp 62 class 2 color R
+p 4 action dscp 63 class 3 color G
+#=================================================================
+#Pipeline 5 : 32 Upstream Routing Rules for 1 ports with dst_ip : 0.0.0.0 to 0.0.255.255
+#=================================================================
+p 5 route add 152.40.0.0 21 port 0 ether {port1_dst_mac} mpls 0:0
+p 5 route add 152.40.8.0 21 port 0 ether {port1_dst_mac} mpls 0:1
+p 5 route add 152.40.16.0 21 port 0 ether {port1_dst_mac} mpls 0:2
+p 5 route add 152.40.24.0 21 port 0 ether {port1_dst_mac} mpls 0:3
+p 5 route add 152.40.32.0 21 port 0 ether {port1_dst_mac} mpls 0:4
+p 5 route add 152.40.40.0 21 port 0 ether {port1_dst_mac} mpls 0:5
+p 5 route add 152.40.48.0 21 port 0 ether {port1_dst_mac} mpls 0:6
+p 5 route add 152.40.56.0 21 port 0 ether {port1_dst_mac} mpls 0:7
+p 5 route add 152.40.64.0 21 port 0 ether {port1_dst_mac} mpls 0:8
+p 5 route add 152.40.72.0 21 port 0 ether {port1_dst_mac} mpls 0:9
+p 5 route add 152.40.80.0 21 port 0 ether {port1_dst_mac} mpls 0:10
+p 5 route add 152.40.88.0 21 port 0 ether {port1_dst_mac} mpls 0:11
+p 5 route add 152.40.96.0 21 port 0 ether {port1_dst_mac} mpls 0:12
+p 5 route add 152.40.104.0 21 port 0 ether {port1_dst_mac} mpls 0:13
+p 5 route add 152.40.112.0 21 port 0 ether {port1_dst_mac} mpls 0:14
+p 5 route add 152.40.120.0 21 port 0 ether {port1_dst_mac} mpls 0:15
+p 5 route add 152.40.128.0 21 port 0 ether {port1_dst_mac} mpls 0:16
+p 5 route add 152.40.136.0 21 port 0 ether {port1_dst_mac} mpls 0:17
+p 5 route add 152.40.144.0 21 port 0 ether {port1_dst_mac} mpls 0:18
+p 5 route add 152.40.152.0 21 port 0 ether {port1_dst_mac} mpls 0:19
+p 5 route add 152.40.160.0 21 port 0 ether {port1_dst_mac} mpls 0:20
+p 5 route add 152.40.168.0 21 port 0 ether {port1_dst_mac} mpls 0:21
+p 5 route add 152.40.176.0 21 port 0 ether {port1_dst_mac} mpls 0:22
+p 5 route add 152.40.184.0 21 port 0 ether {port1_dst_mac} mpls 0:23
+p 5 route add 152.40.192.0 21 port 0 ether {port1_dst_mac} mpls 0:24
+p 5 route add 152.40.200.0 21 port 0 ether {port1_dst_mac} mpls 0:25
+p 5 route add 152.40.208.0 21 port 0 ether {port1_dst_mac} mpls 0:26
+p 5 route add 152.40.216.0 21 port 0 ether {port1_dst_mac} mpls 0:27
+p 5 route add 152.40.224.0 21 port 0 ether {port1_dst_mac} mpls 0:28
+p 5 route add 152.40.232.0 21 port 0 ether {port1_dst_mac} mpls 0:29
+p 5 route add 152.40.240.0 21 port 0 ether {port1_dst_mac} mpls 0:30
+p 5 route add 152.40.248.0 21 port 0 ether {port1_dst_mac} mpls 0:31
+p 5 route add default 1
+
+#=================================================================
+#Pipeline 6 : 256 Downstream Routing Rules for 1 ports with dst_ip : 0.0.0.0 to 0.0.255.255
+#=================================================================
+p 6 route add 152.16.0.0 24 port 0 ether {port0_dst_mac} qinq 0 0
+p 6 route add 152.16.1.0 24 port 0 ether {port0_dst_mac} qinq 0 1
+p 6 route add 152.16.2.0 24 port 0 ether {port0_dst_mac} qinq 0 2
+p 6 route add 152.16.3.0 24 port 0 ether {port0_dst_mac} qinq 0 3
+p 6 route add 152.16.4.0 24 port 0 ether {port0_dst_mac} qinq 0 4
+p 6 route add 152.16.5.0 24 port 0 ether {port0_dst_mac} qinq 0 5
+p 6 route add 152.16.6.0 24 port 0 ether {port0_dst_mac} qinq 0 6
+p 6 route add 152.16.7.0 24 port 0 ether {port0_dst_mac} qinq 0 7
+p 6 route add 152.16.8.0 24 port 0 ether {port0_dst_mac} qinq 0 8
+p 6 route add 152.16.9.0 24 port 0 ether {port0_dst_mac} qinq 0 9
+p 6 route add 152.16.10.0 24 port 0 ether {port0_dst_mac} qinq 0 10
+p 6 route add 152.16.11.0 24 port 0 ether {port0_dst_mac} qinq 0 11
+p 6 route add 152.16.12.0 24 port 0 ether {port0_dst_mac} qinq 0 12
+p 6 route add 152.16.13.0 24 port 0 ether {port0_dst_mac} qinq 0 13
+p 6 route add 152.16.14.0 24 port 0 ether {port0_dst_mac} qinq 0 14
+p 6 route add 152.16.15.0 24 port 0 ether {port0_dst_mac} qinq 0 15
+p 6 route add 152.16.16.0 24 port 0 ether {port0_dst_mac} qinq 0 16
+p 6 route add 152.16.17.0 24 port 0 ether {port0_dst_mac} qinq 0 17
+p 6 route add 152.16.18.0 24 port 0 ether {port0_dst_mac} qinq 0 18
+p 6 route add 152.16.19.0 24 port 0 ether {port0_dst_mac} qinq 0 19
+p 6 route add 152.16.20.0 24 port 0 ether {port0_dst_mac} qinq 0 20
+p 6 route add 152.16.21.0 24 port 0 ether {port0_dst_mac} qinq 0 21
+p 6 route add 152.16.22.0 24 port 0 ether {port0_dst_mac} qinq 0 22
+p 6 route add 152.16.23.0 24 port 0 ether {port0_dst_mac} qinq 0 23
+p 6 route add 152.16.24.0 24 port 0 ether {port0_dst_mac} qinq 0 24
+p 6 route add 152.16.25.0 24 port 0 ether {port0_dst_mac} qinq 0 25
+p 6 route add 152.16.26.0 24 port 0 ether {port0_dst_mac} qinq 0 26
+p 6 route add 152.16.27.0 24 port 0 ether {port0_dst_mac} qinq 0 27
+p 6 route add 152.16.28.0 24 port 0 ether {port0_dst_mac} qinq 0 28
+p 6 route add 152.16.29.0 24 port 0 ether {port0_dst_mac} qinq 0 29
+p 6 route add 152.16.30.0 24 port 0 ether {port0_dst_mac} qinq 0 30
+p 6 route add 152.16.31.0 24 port 0 ether {port0_dst_mac} qinq 0 31
+p 6 route add 152.16.32.0 24 port 0 ether {port0_dst_mac} qinq 0 32
+p 6 route add 152.16.33.0 24 port 0 ether {port0_dst_mac} qinq 0 33
+p 6 route add 152.16.34.0 24 port 0 ether {port0_dst_mac} qinq 0 34
+p 6 route add 152.16.35.0 24 port 0 ether {port0_dst_mac} qinq 0 35
+p 6 route add 152.16.36.0 24 port 0 ether {port0_dst_mac} qinq 0 36
+p 6 route add 152.16.37.0 24 port 0 ether {port0_dst_mac} qinq 0 37
+p 6 route add 152.16.38.0 24 port 0 ether {port0_dst_mac} qinq 0 38
+p 6 route add 152.16.39.0 24 port 0 ether {port0_dst_mac} qinq 0 39
+p 6 route add 152.16.40.0 24 port 0 ether {port0_dst_mac} qinq 0 40
+p 6 route add 152.16.41.0 24 port 0 ether {port0_dst_mac} qinq 0 41
+p 6 route add 152.16.42.0 24 port 0 ether {port0_dst_mac} qinq 0 42
+p 6 route add 152.16.43.0 24 port 0 ether {port0_dst_mac} qinq 0 43
+p 6 route add 152.16.44.0 24 port 0 ether {port0_dst_mac} qinq 0 44
+p 6 route add 152.16.45.0 24 port 0 ether {port0_dst_mac} qinq 0 45
+p 6 route add 152.16.46.0 24 port 0 ether {port0_dst_mac} qinq 0 46
+p 6 route add 152.16.47.0 24 port 0 ether {port0_dst_mac} qinq 0 47
+p 6 route add 152.16.48.0 24 port 0 ether {port0_dst_mac} qinq 0 48
+p 6 route add 152.16.49.0 24 port 0 ether {port0_dst_mac} qinq 0 49
+p 6 route add 152.16.50.0 24 port 0 ether {port0_dst_mac} qinq 0 50
+p 6 route add 152.16.51.0 24 port 0 ether {port0_dst_mac} qinq 0 51
+p 6 route add 152.16.52.0 24 port 0 ether {port0_dst_mac} qinq 0 52
+p 6 route add 152.16.53.0 24 port 0 ether {port0_dst_mac} qinq 0 53
+p 6 route add 152.16.54.0 24 port 0 ether {port0_dst_mac} qinq 0 54
+p 6 route add 152.16.55.0 24 port 0 ether {port0_dst_mac} qinq 0 55
+p 6 route add 152.16.56.0 24 port 0 ether {port0_dst_mac} qinq 0 56
+p 6 route add 152.16.57.0 24 port 0 ether {port0_dst_mac} qinq 0 57
+p 6 route add 152.16.58.0 24 port 0 ether {port0_dst_mac} qinq 0 58
+p 6 route add 152.16.59.0 24 port 0 ether {port0_dst_mac} qinq 0 59
+p 6 route add 152.16.60.0 24 port 0 ether {port0_dst_mac} qinq 0 60
+p 6 route add 152.16.61.0 24 port 0 ether {port0_dst_mac} qinq 0 61
+p 6 route add 152.16.62.0 24 port 0 ether {port0_dst_mac} qinq 0 62
+p 6 route add 152.16.63.0 24 port 0 ether {port0_dst_mac} qinq 0 63
+p 6 route add 152.16.64.0 24 port 0 ether {port0_dst_mac} qinq 0 64
+p 6 route add 152.16.65.0 24 port 0 ether {port0_dst_mac} qinq 0 65
+p 6 route add 152.16.66.0 24 port 0 ether {port0_dst_mac} qinq 0 66
+p 6 route add 152.16.67.0 24 port 0 ether {port0_dst_mac} qinq 0 67
+p 6 route add 152.16.68.0 24 port 0 ether {port0_dst_mac} qinq 0 68
+p 6 route add 152.16.69.0 24 port 0 ether {port0_dst_mac} qinq 0 69
+p 6 route add 152.16.70.0 24 port 0 ether {port0_dst_mac} qinq 0 70
+p 6 route add 152.16.71.0 24 port 0 ether {port0_dst_mac} qinq 0 71
+p 6 route add 152.16.72.0 24 port 0 ether {port0_dst_mac} qinq 0 72
+p 6 route add 152.16.73.0 24 port 0 ether {port0_dst_mac} qinq 0 73
+p 6 route add 152.16.74.0 24 port 0 ether {port0_dst_mac} qinq 0 74
+p 6 route add 152.16.75.0 24 port 0 ether {port0_dst_mac} qinq 0 75
+p 6 route add 152.16.76.0 24 port 0 ether {port0_dst_mac} qinq 0 76
+p 6 route add 152.16.77.0 24 port 0 ether {port0_dst_mac} qinq 0 77
+p 6 route add 152.16.78.0 24 port 0 ether {port0_dst_mac} qinq 0 78
+p 6 route add 152.16.79.0 24 port 0 ether {port0_dst_mac} qinq 0 79
+p 6 route add 152.16.80.0 24 port 0 ether {port0_dst_mac} qinq 0 80
+p 6 route add 152.16.81.0 24 port 0 ether {port0_dst_mac} qinq 0 81
+p 6 route add 152.16.82.0 24 port 0 ether {port0_dst_mac} qinq 0 82
+p 6 route add 152.16.83.0 24 port 0 ether {port0_dst_mac} qinq 0 83
+p 6 route add 152.16.84.0 24 port 0 ether {port0_dst_mac} qinq 0 84
+p 6 route add 152.16.85.0 24 port 0 ether {port0_dst_mac} qinq 0 85
+p 6 route add 152.16.86.0 24 port 0 ether {port0_dst_mac} qinq 0 86
+p 6 route add 152.16.87.0 24 port 0 ether {port0_dst_mac} qinq 0 87
+p 6 route add 152.16.88.0 24 port 0 ether {port0_dst_mac} qinq 0 88
+p 6 route add 152.16.89.0 24 port 0 ether {port0_dst_mac} qinq 0 89
+p 6 route add 152.16.90.0 24 port 0 ether {port0_dst_mac} qinq 0 90
+p 6 route add 152.16.91.0 24 port 0 ether {port0_dst_mac} qinq 0 91
+p 6 route add 152.16.92.0 24 port 0 ether {port0_dst_mac} qinq 0 92
+p 6 route add 152.16.93.0 24 port 0 ether {port0_dst_mac} qinq 0 93
+p 6 route add 152.16.94.0 24 port 0 ether {port0_dst_mac} qinq 0 94
+p 6 route add 152.16.95.0 24 port 0 ether {port0_dst_mac} qinq 0 95
+p 6 route add 152.16.96.0 24 port 0 ether {port0_dst_mac} qinq 0 96
+p 6 route add 152.16.97.0 24 port 0 ether {port0_dst_mac} qinq 0 97
+p 6 route add 152.16.98.0 24 port 0 ether {port0_dst_mac} qinq 0 98
+p 6 route add 152.16.99.0 24 port 0 ether {port0_dst_mac} qinq 0 99
+p 6 route add 152.16.100.0 24 port 0 ether {port0_dst_mac} qinq 0 100
+p 6 route add 152.16.101.0 24 port 0 ether {port0_dst_mac} qinq 0 101
+p 6 route add 152.16.102.0 24 port 0 ether {port0_dst_mac} qinq 0 102
+p 6 route add 152.16.103.0 24 port 0 ether {port0_dst_mac} qinq 0 103
+p 6 route add 152.16.104.0 24 port 0 ether {port0_dst_mac} qinq 0 104
+p 6 route add 152.16.105.0 24 port 0 ether {port0_dst_mac} qinq 0 105
+p 6 route add 152.16.106.0 24 port 0 ether {port0_dst_mac} qinq 0 106
+p 6 route add 152.16.107.0 24 port 0 ether {port0_dst_mac} qinq 0 107
+p 6 route add 152.16.108.0 24 port 0 ether {port0_dst_mac} qinq 0 108
+p 6 route add 152.16.109.0 24 port 0 ether {port0_dst_mac} qinq 0 109
+p 6 route add 152.16.110.0 24 port 0 ether {port0_dst_mac} qinq 0 110
+p 6 route add 152.16.111.0 24 port 0 ether {port0_dst_mac} qinq 0 111
+p 6 route add 152.16.112.0 24 port 0 ether {port0_dst_mac} qinq 0 112
+p 6 route add 152.16.113.0 24 port 0 ether {port0_dst_mac} qinq 0 113
+p 6 route add 152.16.114.0 24 port 0 ether {port0_dst_mac} qinq 0 114
+p 6 route add 152.16.115.0 24 port 0 ether {port0_dst_mac} qinq 0 115
+p 6 route add 152.16.116.0 24 port 0 ether {port0_dst_mac} qinq 0 116
+p 6 route add 152.16.117.0 24 port 0 ether {port0_dst_mac} qinq 0 117
+p 6 route add 152.16.118.0 24 port 0 ether {port0_dst_mac} qinq 0 118
+p 6 route add 152.16.119.0 24 port 0 ether {port0_dst_mac} qinq 0 119
+p 6 route add 152.16.120.0 24 port 0 ether {port0_dst_mac} qinq 0 120
+p 6 route add 152.16.121.0 24 port 0 ether {port0_dst_mac} qinq 0 121
+p 6 route add 152.16.122.0 24 port 0 ether {port0_dst_mac} qinq 0 122
+p 6 route add 152.16.123.0 24 port 0 ether {port0_dst_mac} qinq 0 123
+p 6 route add 152.16.124.0 24 port 0 ether {port0_dst_mac} qinq 0 124
+p 6 route add 152.16.125.0 24 port 0 ether {port0_dst_mac} qinq 0 125
+p 6 route add 152.16.126.0 24 port 0 ether {port0_dst_mac} qinq 0 126
+p 6 route add 152.16.127.0 24 port 0 ether {port0_dst_mac} qinq 0 127
+p 6 route add 152.16.128.0 24 port 0 ether {port0_dst_mac} qinq 0 128
+p 6 route add 152.16.129.0 24 port 0 ether {port0_dst_mac} qinq 0 129
+p 6 route add 152.16.130.0 24 port 0 ether {port0_dst_mac} qinq 0 130
+p 6 route add 152.16.131.0 24 port 0 ether {port0_dst_mac} qinq 0 131
+p 6 route add 152.16.132.0 24 port 0 ether {port0_dst_mac} qinq 0 132
+p 6 route add 152.16.133.0 24 port 0 ether {port0_dst_mac} qinq 0 133
+p 6 route add 152.16.134.0 24 port 0 ether {port0_dst_mac} qinq 0 134
+p 6 route add 152.16.135.0 24 port 0 ether {port0_dst_mac} qinq 0 135
+p 6 route add 152.16.136.0 24 port 0 ether {port0_dst_mac} qinq 0 136
+p 6 route add 152.16.137.0 24 port 0 ether {port0_dst_mac} qinq 0 137
+p 6 route add 152.16.138.0 24 port 0 ether {port0_dst_mac} qinq 0 138
+p 6 route add 152.16.139.0 24 port 0 ether {port0_dst_mac} qinq 0 139
+p 6 route add 152.16.140.0 24 port 0 ether {port0_dst_mac} qinq 0 140
+p 6 route add 152.16.141.0 24 port 0 ether {port0_dst_mac} qinq 0 141
+p 6 route add 152.16.142.0 24 port 0 ether {port0_dst_mac} qinq 0 142
+p 6 route add 152.16.143.0 24 port 0 ether {port0_dst_mac} qinq 0 143
+p 6 route add 152.16.144.0 24 port 0 ether {port0_dst_mac} qinq 0 144
+p 6 route add 152.16.145.0 24 port 0 ether {port0_dst_mac} qinq 0 145
+p 6 route add 152.16.146.0 24 port 0 ether {port0_dst_mac} qinq 0 146
+p 6 route add 152.16.147.0 24 port 0 ether {port0_dst_mac} qinq 0 147
+p 6 route add 152.16.148.0 24 port 0 ether {port0_dst_mac} qinq 0 148
+p 6 route add 152.16.149.0 24 port 0 ether {port0_dst_mac} qinq 0 149
+p 6 route add 152.16.150.0 24 port 0 ether {port0_dst_mac} qinq 0 150
+p 6 route add 152.16.151.0 24 port 0 ether {port0_dst_mac} qinq 0 151
+p 6 route add 152.16.152.0 24 port 0 ether {port0_dst_mac} qinq 0 152
+p 6 route add 152.16.153.0 24 port 0 ether {port0_dst_mac} qinq 0 153
+p 6 route add 152.16.154.0 24 port 0 ether {port0_dst_mac} qinq 0 154
+p 6 route add 152.16.155.0 24 port 0 ether {port0_dst_mac} qinq 0 155
+p 6 route add 152.16.156.0 24 port 0 ether {port0_dst_mac} qinq 0 156
+p 6 route add 152.16.157.0 24 port 0 ether {port0_dst_mac} qinq 0 157
+p 6 route add 152.16.158.0 24 port 0 ether {port0_dst_mac} qinq 0 158
+p 6 route add 152.16.159.0 24 port 0 ether {port0_dst_mac} qinq 0 159
+p 6 route add 152.16.160.0 24 port 0 ether {port0_dst_mac} qinq 0 160
+p 6 route add 152.16.161.0 24 port 0 ether {port0_dst_mac} qinq 0 161
+p 6 route add 152.16.162.0 24 port 0 ether {port0_dst_mac} qinq 0 162
+p 6 route add 152.16.163.0 24 port 0 ether {port0_dst_mac} qinq 0 163
+p 6 route add 152.16.164.0 24 port 0 ether {port0_dst_mac} qinq 0 164
+p 6 route add 152.16.165.0 24 port 0 ether {port0_dst_mac} qinq 0 165
+p 6 route add 152.16.166.0 24 port 0 ether {port0_dst_mac} qinq 0 166
+p 6 route add 152.16.167.0 24 port 0 ether {port0_dst_mac} qinq 0 167
+p 6 route add 152.16.168.0 24 port 0 ether {port0_dst_mac} qinq 0 168
+p 6 route add 152.16.169.0 24 port 0 ether {port0_dst_mac} qinq 0 169
+p 6 route add 152.16.170.0 24 port 0 ether {port0_dst_mac} qinq 0 170
+p 6 route add 152.16.171.0 24 port 0 ether {port0_dst_mac} qinq 0 171
+p 6 route add 152.16.172.0 24 port 0 ether {port0_dst_mac} qinq 0 172
+p 6 route add 152.16.173.0 24 port 0 ether {port0_dst_mac} qinq 0 173
+p 6 route add 152.16.174.0 24 port 0 ether {port0_dst_mac} qinq 0 174
+p 6 route add 152.16.175.0 24 port 0 ether {port0_dst_mac} qinq 0 175
+p 6 route add 152.16.176.0 24 port 0 ether {port0_dst_mac} qinq 0 176
+p 6 route add 152.16.177.0 24 port 0 ether {port0_dst_mac} qinq 0 177
+p 6 route add 152.16.178.0 24 port 0 ether {port0_dst_mac} qinq 0 178
+p 6 route add 152.16.179.0 24 port 0 ether {port0_dst_mac} qinq 0 179
+p 6 route add 152.16.180.0 24 port 0 ether {port0_dst_mac} qinq 0 180
+p 6 route add 152.16.181.0 24 port 0 ether {port0_dst_mac} qinq 0 181
+p 6 route add 152.16.182.0 24 port 0 ether {port0_dst_mac} qinq 0 182
+p 6 route add 152.16.183.0 24 port 0 ether {port0_dst_mac} qinq 0 183
+p 6 route add 152.16.184.0 24 port 0 ether {port0_dst_mac} qinq 0 184
+p 6 route add 152.16.185.0 24 port 0 ether {port0_dst_mac} qinq 0 185
+p 6 route add 152.16.186.0 24 port 0 ether {port0_dst_mac} qinq 0 186
+p 6 route add 152.16.187.0 24 port 0 ether {port0_dst_mac} qinq 0 187
+p 6 route add 152.16.188.0 24 port 0 ether {port0_dst_mac} qinq 0 188
+p 6 route add 152.16.189.0 24 port 0 ether {port0_dst_mac} qinq 0 189
+p 6 route add 152.16.190.0 24 port 0 ether {port0_dst_mac} qinq 0 190
+p 6 route add 152.16.191.0 24 port 0 ether {port0_dst_mac} qinq 0 191
+p 6 route add 152.16.192.0 24 port 0 ether {port0_dst_mac} qinq 0 192
+p 6 route add 152.16.193.0 24 port 0 ether {port0_dst_mac} qinq 0 193
+p 6 route add 152.16.194.0 24 port 0 ether {port0_dst_mac} qinq 0 194
+p 6 route add 152.16.195.0 24 port 0 ether {port0_dst_mac} qinq 0 195
+p 6 route add 152.16.196.0 24 port 0 ether {port0_dst_mac} qinq 0 196
+p 6 route add 152.16.197.0 24 port 0 ether {port0_dst_mac} qinq 0 197
+p 6 route add 152.16.198.0 24 port 0 ether {port0_dst_mac} qinq 0 198
+p 6 route add 152.16.199.0 24 port 0 ether {port0_dst_mac} qinq 0 199
+p 6 route add 152.16.200.0 24 port 0 ether {port0_dst_mac} qinq 0 200
+p 6 route add 152.16.201.0 24 port 0 ether {port0_dst_mac} qinq 0 201
+p 6 route add 152.16.202.0 24 port 0 ether {port0_dst_mac} qinq 0 202
+p 6 route add 152.16.203.0 24 port 0 ether {port0_dst_mac} qinq 0 203
+p 6 route add 152.16.204.0 24 port 0 ether {port0_dst_mac} qinq 0 204
+p 6 route add 152.16.205.0 24 port 0 ether {port0_dst_mac} qinq 0 205
+p 6 route add 152.16.206.0 24 port 0 ether {port0_dst_mac} qinq 0 206
+p 6 route add 152.16.207.0 24 port 0 ether {port0_dst_mac} qinq 0 207
+p 6 route add 152.16.208.0 24 port 0 ether {port0_dst_mac} qinq 0 208
+p 6 route add 152.16.209.0 24 port 0 ether {port0_dst_mac} qinq 0 209
+p 6 route add 152.16.210.0 24 port 0 ether {port0_dst_mac} qinq 0 210
+p 6 route add 152.16.211.0 24 port 0 ether {port0_dst_mac} qinq 0 211
+p 6 route add 152.16.212.0 24 port 0 ether {port0_dst_mac} qinq 0 212
+p 6 route add 152.16.213.0 24 port 0 ether {port0_dst_mac} qinq 0 213
+p 6 route add 152.16.214.0 24 port 0 ether {port0_dst_mac} qinq 0 214
+p 6 route add 152.16.215.0 24 port 0 ether {port0_dst_mac} qinq 0 215
+p 6 route add 152.16.216.0 24 port 0 ether {port0_dst_mac} qinq 0 216
+p 6 route add 152.16.217.0 24 port 0 ether {port0_dst_mac} qinq 0 217
+p 6 route add 152.16.218.0 24 port 0 ether {port0_dst_mac} qinq 0 218
+p 6 route add 152.16.219.0 24 port 0 ether {port0_dst_mac} qinq 0 219
+p 6 route add 152.16.220.0 24 port 0 ether {port0_dst_mac} qinq 0 220
+p 6 route add 152.16.221.0 24 port 0 ether {port0_dst_mac} qinq 0 221
+p 6 route add 152.16.222.0 24 port 0 ether {port0_dst_mac} qinq 0 222
+p 6 route add 152.16.223.0 24 port 0 ether {port0_dst_mac} qinq 0 223
+p 6 route add 152.16.224.0 24 port 0 ether {port0_dst_mac} qinq 0 224
+p 6 route add 152.16.225.0 24 port 0 ether {port0_dst_mac} qinq 0 225
+p 6 route add 152.16.226.0 24 port 0 ether {port0_dst_mac} qinq 0 226
+p 6 route add 152.16.227.0 24 port 0 ether {port0_dst_mac} qinq 0 227
+p 6 route add 152.16.228.0 24 port 0 ether {port0_dst_mac} qinq 0 228
+p 6 route add 152.16.229.0 24 port 0 ether {port0_dst_mac} qinq 0 229
+p 6 route add 152.16.230.0 24 port 0 ether {port0_dst_mac} qinq 0 230
+p 6 route add 152.16.231.0 24 port 0 ether {port0_dst_mac} qinq 0 231
+p 6 route add 152.16.232.0 24 port 0 ether {port0_dst_mac} qinq 0 232
+p 6 route add 152.16.233.0 24 port 0 ether {port0_dst_mac} qinq 0 233
+p 6 route add 152.16.234.0 24 port 0 ether {port0_dst_mac} qinq 0 234
+p 6 route add 152.16.235.0 24 port 0 ether {port0_dst_mac} qinq 0 235
+p 6 route add 152.16.236.0 24 port 0 ether {port0_dst_mac} qinq 0 236
+p 6 route add 152.16.237.0 24 port 0 ether {port0_dst_mac} qinq 0 237
+p 6 route add 152.16.238.0 24 port 0 ether {port0_dst_mac} qinq 0 238
+p 6 route add 152.16.239.0 24 port 0 ether {port0_dst_mac} qinq 0 239
+p 6 route add 152.16.240.0 24 port 0 ether {port0_dst_mac} qinq 0 240
+p 6 route add 152.16.241.0 24 port 0 ether {port0_dst_mac} qinq 0 241
+p 6 route add 152.16.242.0 24 port 0 ether {port0_dst_mac} qinq 0 242
+p 6 route add 152.16.243.0 24 port 0 ether {port0_dst_mac} qinq 0 243
+p 6 route add 152.16.244.0 24 port 0 ether {port0_dst_mac} qinq 0 244
+p 6 route add 152.16.245.0 24 port 0 ether {port0_dst_mac} qinq 0 245
+p 6 route add 152.16.246.0 24 port 0 ether {port0_dst_mac} qinq 0 246
+p 6 route add 152.16.247.0 24 port 0 ether {port0_dst_mac} qinq 0 247
+p 6 route add 152.16.248.0 24 port 0 ether {port0_dst_mac} qinq 0 248
+p 6 route add 152.16.249.0 24 port 0 ether {port0_dst_mac} qinq 0 249
+p 6 route add 152.16.250.0 24 port 0 ether {port0_dst_mac} qinq 0 250
+p 6 route add 152.16.251.0 24 port 0 ether {port0_dst_mac} qinq 0 251
+p 6 route add 152.16.252.0 24 port 0 ether {port0_dst_mac} qinq 0 252
+p 6 route add 152.16.253.0 24 port 0 ether {port0_dst_mac} qinq 0 253
+p 6 route add 152.16.254.0 24 port 0 ether {port0_dst_mac} qinq 0 254
+p 6 route add 152.16.255.0 24 port 0 ether {port0_dst_mac} qinq 0 255
+p 6 route add default 1
diff --git a/samples/vnf_samples/nsut/vpe/vpe_vnf_topology.yaml b/samples/vnf_samples/nsut/vpe/vpe_vnf_topology.yaml
new file mode 100644
index 000000000..0de4b6e79
--- /dev/null
+++ b/samples/vnf_samples/nsut/vpe/vpe_vnf_topology.yaml
@@ -0,0 +1,50 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+nsd:nsd-catalog:
+ nsd:
+ - id: VPE
+ name: VPE
+ short-name: VPE
+ description: scenario with VPE,L3fwd and VNF
+ constituent-vnfd:
+ - member-vnf-index: '1'
+ vnfd-id-ref: tg__1
+ VNF model: ../../vnf_descriptors/tg_rfc2544_tpl.yaml #tg_vpe_upstream.yaml #VPE VNF
+ - member-vnf-index: '2'
+ vnfd-id-ref: vnf__1
+ VNF model: ../../vnf_descriptors/vpe_vnf.yaml #tg_l3fwd.yaml #tg_trex_tpl.yaml #TREX
+
+ vld:
+ - id: private
+ name: tg__1 to vnf__1 link 1
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: tg__1 #TREX
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe0
+ vnfd-id-ref: vnf__1 #VNF
+
+ - id: public
+ name: vnf__1 to tg__1 link 2
+ type: ELAN
+ vnfd-connection-point-ref:
+ - member-vnf-index-ref: '2'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: vnf__1 #L3fwd
+ - member-vnf-index-ref: '1'
+ vnfd-connection-point-ref: xe1
+ vnfd-id-ref: tg__1 #VPE VNF
diff --git a/samples/vnf_samples/traffic_profiles/example.yaml b/samples/vnf_samples/traffic_profiles/example.yaml
new file mode 100644
index 000000000..71371995e
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/example.yaml
@@ -0,0 +1,198 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+schema: "nsb:traffic_profile:0.1"
+
+# This file is a template, it will be filled with values from tc.yaml before passing to the traffic generator
+
+name: rfc2544
+description: Traffic profile to run RFC2544 latency
+traffic_profile:
+ traffic_type : rfc2544 # defines traffic behavior - constant or look for highest possible throughput
+ frame_rate : 100 # pc of linerate
+ flow_number: {{ flow.number }} #This decides how many frames should be generated. Each frame should have a random of the field
+ # that specifies a range (e.g. ipv4 address, port)
+
+private:
+ - ipv4_1:
+ outer_l2:
+ framesize:
+ 64B: {{ get(imix_small, 12) }}
+ 128B: {{get(imix_128B, 12) }}
+ 256B: {{get(imix_256B, 12) }}
+ 373b: {{ get(imix_373B, 12) }}
+ 570B: {{get(imix_570B, 12) }}
+ 1400B: {{get(imix_1400B, 12) }}
+ 1518b: {{get(imix_1500B, 12) }}
+ srcmac: {{src_mac}} # xe0.local_mac
+ dstmac: {{dst_mac}} # xe0.dst_mac
+ QinQ:
+ S-VLAN:
+ id: {{ get(flow.s_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ C-VLAN:
+ id: {{ get(flow.c_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ mpls:
+ label: {{ get(flow.mpls_label, "0") }}
+
+ outer_l3v4:
+ proto: {{ get(flow.outer_proto, "udp") }},
+ srcip4: {{ get(flow.outer_srcip4, "1.1.1.1") }}
+ dstip4: {{ get(flow.outer_dstip4, "90.90.90.90") }}
+ ttl: 32
+ dscp: {{ get(flow.tos, 0) }}
+
+ outer_l4:
+ srcport: {{ get(flow.outer_srcport, "3002") }}
+ dstport: {{ get(flow.outer_dstport, "3001") }}
+ vni: {{ get(flow.vxlan_vni, "2345") }} #optional
+ inner_l2: #optional
+ srcmac: {{ get(flow.inner_srcmac, "00:00:00:00:00:00") }}
+ dstmac: {{ get(flow.inner_dstmac, "00:00:00:00:00:00") }}
+
+ inner_l3v4: #optional
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip4: {{ get(flow.inner_srcip4, "1.1.1.1") }}
+ dstip4: {{ get(flow.inner_dstip4, "90.90.90.90") }}
+ ttl: 32
+ dscp: {{ get(flow.inner_tos, 0) }}
+
+ inner_l3v6:
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip6: {{ get(flow.inner_srcip6, "2001::1") }}
+ dstip6: {{ get(flow.outer_dstip6, "2001::11") }}
+ ttl: 32
+ tc: {{ get(flow.inner_tos, 0) }}
+
+ inner_l4:
+ srcport: {{ get(flow.inner_srcport, "3002") }}
+ dstport: {{ get(flow.inner_dstport, "3001") }}
+
+ - ipv6_2:
+ outer_l2:
+ framesize:
+ 64B: {{ get(imix_small, 12) }}
+ 128B: {{get(imix_128B, 12) }}
+ 256B: {{get(imix_256B, 12) }}
+ 373b: {{ get(imix_373B, 12) }}
+ 570B: {{get(imix_570B, 12) }}
+ 1400B: {{get(imix_1400B, 12) }}
+ 1518b: {{get(imix_1500B, 12) }}
+ srcmac: {{src_mac}} # xe0.local_mac
+ dstmac: {{dst_mac}} # xe0.dst_mac
+ QinQ:
+ S-VLAN:
+ id: {{ get(flow.s_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ C-VLAN:
+ id: {{ get(flow.c_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ mpls:
+ label: {{ get(flow.mpls_label, "0") }}
+
+ outer_l3v6:
+ proto: {{ get(flow.outer_proto, "udp") }},
+ srcip6: {{ get(flow.outer_srcip6, "2001::1") }}
+ dstip6: {{ get(flow.outer_dstip6, "2001::11") }}
+ ttl: 32
+ tc: {{ get(flow.outer_tos, 0) }}
+
+ outer_l4:
+ srcport: {{ get(flow.outer_srcport, "3002") }}
+ dstport: {{ get(flow.outer_dstport, "3001") }}
+ vni: {{ get(flow.vxlan_vni, "2345") }} #optional
+ inner_l2: #optional
+ srcmac: {{ get(flow.inner_srcmac, "00:00:00:00:00:00") }}
+ dstmac: {{ get(flow.inner_dstmac, "00:00:00:00:00:00") }}
+
+ inner_l3v4: #optional
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip4: {{ get(flow.inner_srcip4, "1.1.1.1") }}
+ dstip4: {{ get(flow.inner_dstip4, "90.90.90.90") }}
+ ttl: 32
+ dscp: {{ get(flow.inner_tos, 0) }}
+
+ inner_l3v6:
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip6: {{ get(flow.inner_srcip6, "2001::1") }}
+ dstip6: {{ get(flow.outer_dstip6, "2001::11") }}
+ ttl: 32
+ tc: {{ get(flow.inner_tos, 0) }}
+
+ inner_l4:
+ srcport: {{ get(flow.inner_srcport, "3002") }}
+ dstport: {{ get(flow.inner_dstport, "3001") }}
+
+public:
+ - ipv4_2:
+ outer_l2:
+ framesize:
+ 64B: {{ get(imix_small, 12) }}
+ 128B: {{get(imix_128B, 12) }}
+ 256B: {{get(imix_256B, 12) }}
+ 373b: {{ get(imix_373B, 12) }}
+ 570B: {{get(imix_570B, 12) }}
+ 1400B: {{get(imix_1400B, 12) }}
+ 1518b: {{get(imix_1500B, 12) }}
+ srcmac: {{get(private.ipv4_1.dst_mac}} # xe0.local_mac
+ dstmac: {{get)private.ipv4_1.src_mac}} # xe0.dst_mac
+ QinQ:
+ S-VLAN:
+ id: {{ get(flow.s_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ C-VLAN:
+ id: {{ get(flow.c_vlan_range, "0") }}
+ priority: 0
+ cfi: 0
+ mpls:
+ label: {{ get(flow.mpls_label, "0") }}
+
+ outer_l3v4:
+ proto: {{ get(flow.outer_proto, "udp") }},
+ srcip4: {{ get(private.ipv4_1.outer_l3v4.dstip4) }}
+ dstip4: {{ get(private.ipv4_1.outer_l3v4.srcip4) }}
+ ttl: 32
+ dscp: {{ get(flow.tos, 0) }}
+
+ outer_l4:
+ srcport: {{ get(private.ipv4_1.outer_l4.dstport) }}
+ dstport: {{ get(private.ipv4_1.outer_l4.srcport) }}
+ vni: {{ get(flow.vxlan_vni, "2345") }} #optional
+ inner_l2: #optional
+ srcmac: {{ get(private.ipv4_1.outer_l4.inner_l2.dstmac) }}
+ dstmac: {{ get(private.ipv4_1.outer_l4.inner_l2.srcmac) }}
+
+ inner_l3v4: #optional
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip4: {{ get(private.ipv4_1.inner_l3v4.dstip4) }}
+ dstip4: {{ get(private.ipv4_1.inner_l3v4.srcip4) }}
+ ttl: 32
+ dscp: {{ get(flow.inner_tos, 0) }}
+
+ inner_l3v6:
+ proto: {{ get(flow.inner_proto, "udp") }},
+ srcip6: {{ get(private.ipv4_1.inner_l3v6.dstip6) }}
+ dstip6: {{ get(private.ipv4_1.inner_l3v6.srcip6) }}
+ ttl: 32
+ tc: {{ get(flow.inner_tos, 0) }}
+
+ inner_l4:
+ srcport: {{ get(private.ipv4_1.inner_l4.dstport) }}
+ dstport: {{ get(private.ipv4_1.inner_l4.srcport) }}
diff --git a/samples/vnf_samples/traffic_profiles/fixed.yaml b/samples/vnf_samples/traffic_profiles/fixed.yaml
new file mode 100644
index 000000000..afccd6fd4
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/fixed.yaml
@@ -0,0 +1,24 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+schema: "nsb:traffic_profile:0.1"
+
+name: fixed
+description: Fixed traffic profile to run UDP traffic
+
+traffic_profile:
+ traffic_type: FixedProfile
+ frame_rate: 100 # pps
+ flow_number: 10
+ frame_size: 64
diff --git a/samples/vnf_samples/traffic_profiles/imix_storage.yaml b/samples/vnf_samples/traffic_profiles/imix_storage.yaml
new file mode 100644
index 000000000..8fd10ecbe
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/imix_storage.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+#imix definition for storage traffic
+#
+# it is a typical case for testing the synthetic VNF performance.
+#
+#percentage of the packets can be less than 100%
+#the traffic in downstream and upstream direction could be different
+
+schema: "nsb:imix:0.1"
+
+imix:
+ private:
+ imix_small: 0 #ipv4 case - 72B should be 0 ipv6 case - 84B
+ imix_128B: 0
+ imix_256B: 0
+ imix_373B: 0
+ imix_570B: 0
+ imix_1400B: 0
+ imix_1500B: 100
+
+ public:
+ imix_small: 0 #ipv4 case - 72B ipv6 - 84B
+ imix_128B: 0
+ imix_256B: 0
+ imix_373B: 0
+ imix_570B: 0
+ imix_1400B: 0
+ imix_1500B: 100
diff --git a/samples/vnf_samples/traffic_profiles/imix_video.yaml b/samples/vnf_samples/traffic_profiles/imix_video.yaml
new file mode 100644
index 000000000..36324bfa4
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/imix_video.yaml
@@ -0,0 +1,43 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+#imix definition for video traffic
+#
+# this is a real traffic profile when video/data traffic only is present
+#
+#percentage of the packets can be less than 100%
+#the traffic in downstream and upstream direction could be different
+#
+#small means ipv4 case - 72B should be 0, ipv6 case - 84B
+
+schema: "nsb:imix:0.1"
+
+imix:
+ private:
+ imix_small: 5 #ipv4 case - 72B should be 0 ipv6 case - 84B
+ imix_128B: 11
+ imix_256B: 16
+ imix_373B: 10
+ imix_570B: 35
+ imix_1400B: 10
+ imix_1500B: 13
+
+ public:
+ imix_small: 5 #ipv4 case - 72B ipv6 - 84B
+ imix_128B: 3
+ imix_256B: 4
+ imix_373B: 6
+ imix_570B: 8
+ imix_1400B: 36
+ imix_1500B: 38
diff --git a/samples/vnf_samples/traffic_profiles/imix_voice.yaml b/samples/vnf_samples/traffic_profiles/imix_voice.yaml
new file mode 100644
index 000000000..b8f8e5358
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/imix_voice.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+#imix definition for voice traffic
+#
+# it is a typical case for testing the synthetic VNF performance.
+#
+#percentage of the packets can be less than 100%
+#the traffic in downstream and upstream direction could be different
+
+schema: "nsb:imix:0.1"
+
+imix:
+ private:
+ imix_small: 100 #ipv4 case - 72B should be 0 ipv6 case - 84B
+ imix_128B: 0
+ imix_256B: 0
+ imix_373B: 0
+ imix_570B: 0
+ imix_1400B: 0
+ imix_1500B: 0
+
+ public:
+ imix_small: 100 #ipv4 case - 72B ipv6 - 84B
+ imix_128B: 0
+ imix_256B: 0
+ imix_373B: 0
+ imix_570B: 0
+ imix_1400B: 0
+ imix_1500B: 0
diff --git a/samples/vnf_samples/traffic_profiles/ipv4_1flow_Packets_vpe.yaml b/samples/vnf_samples/traffic_profiles/ipv4_1flow_Packets_vpe.yaml
new file mode 100644
index 000000000..f3046f463
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/ipv4_1flow_Packets_vpe.yaml
@@ -0,0 +1,18 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+flow:
+ srcip4_range: '152.16.0.20'
+ dstip4_range: '152.40.0.20'
+ count: 1
diff --git a/samples/vnf_samples/traffic_profiles/ipv4_throughput_vpe.yaml b/samples/vnf_samples/traffic_profiles/ipv4_throughput_vpe.yaml
new file mode 100644
index 000000000..cfa166a74
--- /dev/null
+++ b/samples/vnf_samples/traffic_profiles/ipv4_throughput_vpe.yaml
@@ -0,0 +1,101 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+# flow definition for ACL tests - 1K flows - ipv4 only
+#
+# the number of flows defines the widest range of parameters
+# for example if srcip_range=1.0.0.1-1.0.0.255 and dst_ip_range=10.0.0.1-10.0.1.255
+# and it should define only 16 flows
+#
+#there is assumption that packets generated will have a random sequences of following addresses pairs
+# in the packets
+# 1. src=1.x.x.x(x.x.x =random from 1..255) dst=10.x.x.x (random from 1..512)
+# 2. src=1.x.x.x(x.x.x =random from 1..255) dst=10.x.x.x (random from 1..512)
+# ...
+# 512. src=1.x.x.x(x.x.x =random from 1..255) dst=10.x.x.x (random from 1..512)
+#
+# not all combination should be filled
+# Any other field with random range will be added to flow definition
+#
+# the example.yaml provides all possibilities for traffic generation
+#
+# the profile defines a public and private side to make limited traffic correlation
+# between private and public side same way as it is made by IXIA solution.
+#
+schema: "isb:traffic_profile:0.1"
+
+# This file is a template, it will be filled with values from tc.yaml before passing to the traffic generator
+
+name: rfc2544
+description: Traffic profile to run RFC2544 latency
+traffic_profile:
+ traffic_type : RFC2544Profile # defines traffic behavior - constant or look for highest possible throughput
+ frame_rate : 100 # pc of linerate
+ # that specifies a range (e.g. ipv4 address, port)
+
+
+private:
+ ipv4:
+ outer_l2:
+ framesize:
+ 64B: "{{ get(imix, 'imix.private.imix_small', '0') }}"
+ 128B: "{{ get(imix, 'imix.private.imix_128B', '0') }}"
+ 256B: "{{ get(imix, 'imix.private.imix_256B', '0') }}"
+ 373b: "{{ get(imix, 'imix.private.imix_373B', '0') }}"
+ 570B: "{{get(imix, 'imix.private.imix_570B', '0') }}"
+ 1400B: "{{get(imix, 'imix.private.imix_1400B', '0') }}"
+ 1518B: "{{get(imix, 'imix.private.imix_1500B', '0') }}"
+
+ QinQ:
+ S-VLAN:
+ id: 128
+ priority: 0
+ cfi: 0
+ C-VLAN:
+ id: 512
+ priority: 0
+ cfi: 0
+
+ outer_l3v4:
+ proto: "tcp"
+ srcip4: "{{get(flow, 'flow.srcip4_range', '192.168.0.0-192.168.255.255') }}"
+ dstip4: "{{get(flow, 'flow.dstip4_range', '192.16.0.0-192.16.0.31') }}"
+ ttl: 32
+ dscp: 32
+
+ outer_l4:
+ srcport: "{{get(flow, 'flow.srcport_range', '0') }}"
+ dstport: "{{get(flow, 'flow.dstport_range', '0') }}"
+public:
+ ipv4:
+ outer_l2:
+ framesize:
+ 64B: "{{ get(imix, 'imix.private.imix_small', '0') }}"
+ 128B: "{{ get(imix, 'imix.private.imix_128B', '0') }}"
+ 256B: "{{ get(imix, 'imix.private.imix_256B', '0') }}"
+ 373b: "{{ get(imix, 'imix.private.imix_373B', '0') }}"
+ 570B: "{{get(imix, 'imix.private.imix_570B', '0') }}"
+ 1400B: "{{get(imix, 'imix.private.imix_1400B', '0') }}"
+ 1518B: "{{get(imix, 'imix.private.imix_1500B', '0') }}"
+
+ outer_l3v4:
+ proto: "tcp"
+ srcip4: "{{get(flow, 'flow.dstip4_range', '192.16.0.0-192.16.0.31') }}"
+ dstip4: "{{get(flow, 'flow.srcip4_range', '192.168.0.0-192.168.255.255') }}"
+ ttl: 32
+ dscp: 32
+
+ outer_l4:
+ srcport: "{{get(flow, 'flow.dstport_range', '0') }}"
+ dstport: "{{get(flow, 'flow.srcport_range', '0') }}"
diff --git a/samples/vnf_samples/vnf_descriptors/tg_ping_tpl.yaml b/samples/vnf_samples/vnf_descriptors/tg_ping_tpl.yaml
new file mode 100644
index 000000000..6e8fcf77e
--- /dev/null
+++ b/samples/vnf_samples/vnf_descriptors/tg_ping_tpl.yaml
@@ -0,0 +1,68 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+vnfd:vnfd-catalog:
+ vnfd:
+ - id: PingTrafficGen
+ name: pinggen
+ short-name: pinggen
+ description: Sample 1-port ping generator
+ vm-flavor:
+ vcpu-count: '4'
+ memory-mb: '4096'
+ mgmt-interface:
+ vdu-id: pinggen-baremetal
+ user: '{{user}}' # Value filled by vnfdgen
+ password: '{{password}}' # Value filled by vnfdgen
+ ip: '{{ip}}' # Value filled by vnfdgen
+ connection-point:
+ - name: xe0
+ type: VPORT
+ - name: xe1
+ type: VPORT
+ vdu:
+ - id: pinggen-baremetal
+ name: pinggen-baremetal
+ description: Sample 1-port ping generator
+ external-interface:
+ - name: xe0
+ virtual-interface:
+ type: virtio
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe0.vpci }}' # Value filled by vnfdgen
+ local_iface_name: '{{ interfaces.xe0.local_iface_name }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe0.driver}}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe0.local_ip }}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe0.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe0.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe0.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe0
+ - name: xe1
+ virtual-interface:
+ type: virtio
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe1.vpci }}' # Value filled by vnfdgen
+ local_iface_name: '{{ interfaces.xe1.local_iface_name }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe1.local_ip }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe1.driver}}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe1.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe1.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe1.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe0
+ benchmark:
+ kpi:
+ - rtt
+ - packets_trasmitted
diff --git a/samples/vnf_samples/vnf_descriptors/tg_rfc2544_tpl.yaml b/samples/vnf_samples/vnf_descriptors/tg_rfc2544_tpl.yaml
new file mode 100644
index 000000000..97feae5ba
--- /dev/null
+++ b/samples/vnf_samples/vnf_descriptors/tg_rfc2544_tpl.yaml
@@ -0,0 +1,69 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+vnfd:vnfd-catalog:
+ vnfd:
+ - id: TrexTrafficGenRFC # nsb class mapping
+ name: trexverifier
+ short-name: trexverifier
+ description: TRex stateless traffic verifier
+ mgmt-interface:
+ vdu-id: trexgen-baremetal
+ user: '{{user}}' # Value filled by vnfdgen
+ password: '{{password}}' # Value filled by vnfdgen
+ ip: '{{ip}}' # Value filled by vnfdgen
+ connection-point:
+ - name: xe0
+ type: VPORT
+ - name: xe1
+ type: VPORT
+ vdu:
+ - id: trexgen-baremetal
+ name: trexgen-baremetal
+ description: TRex stateless traffic verifier
+ external-interface:
+ - name: xe0
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe0.vpci }}' # Value filled by vnfdgen
+ local_iface_name: '{{ interfaces.xe0.local_iface_name }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe0.local_ip }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe0.driver}}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe0.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe0.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe0.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe0
+ - name: xe1
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ vpci: '{{ interfaces.xe1.vpci }}' # Value filled by vnfdgen
+ local_iface_name: '{{ interfaces.xe1.local_iface_name }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe1.local_ip }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe1.driver}}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe1.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe1.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe1.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe1
+
+ benchmark:
+ kpi:
+ - rx_throughput_fps
+ - tx_throughput_fps
+ - tx_throughput_mbps
+ - rx_throughput_mbps
+ - in_packets
+ - out_packets
diff --git a/samples/vnf_samples/vnf_descriptors/tg_trex_tpl.yaml b/samples/vnf_samples/vnf_descriptors/tg_trex_tpl.yaml
new file mode 100644
index 000000000..b1641836b
--- /dev/null
+++ b/samples/vnf_samples/vnf_descriptors/tg_trex_tpl.yaml
@@ -0,0 +1,75 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+vnfd:vnfd-catalog:
+ vnfd:
+ - id: TrexTrafficGen # NSPerf class mapping
+ name: trexgen
+ short-name: trexgen
+ description: TRex stateless traffic generator for tests
+ vm-flavor:
+ vcpu-count: '4'
+ memory-mb: '4096'
+ mgmt-interface:
+ vdu-id: trexgen-baremetal
+ user: '{{user}}' # Value filled by vnfdgen
+ password: '{{password}}' # Value filled by vnfdgen
+ ip: '{{ip}}' # Value filled by vnfdgen
+ connection-point:
+ - name: xe0
+ type: VPORT
+ - name: xe1
+ type: VPORT
+ vdu:
+ - id: trexgen-baremetal
+ name: trexgen-baremetal
+ description: TRex stateless traffic generator for tests
+ external-interface:
+ - name: xe0
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe0.vpci }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe0.local_ip }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe0.driver}}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe0.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe0.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe0.dst_mac }}' # Value filled by vnfdgen
+ vld_id: '{{ interfaces.xe0.vld_id }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe0
+ - name: xe1
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ vpci: '{{ interfaces.xe1.vpci }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe1.local_ip }}' # Value filled by vnfdgen
+ driver: '{{ interfaces.xe1.driver}}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe1.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe1.local_mac }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe1.dst_mac }}' # Value filled by vnfdgen
+ vld_id: '{{ interfaces.xe1.vld_id }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe1
+
+ benchmark:
+ kpi:
+ - rx_throughput_fps
+ - tx_throughput_fps
+ - tx_throughput_mbps
+ - rx_throughput_mbps
+ - tx_throughput_pc_linerate
+ - rx_throughput_pc_linerate
+ - min_latency
+ - max_latency
+ - avg_latency
diff --git a/samples/vnf_samples/vnf_descriptors/vpe_vnf.yaml b/samples/vnf_samples/vnf_descriptors/vpe_vnf.yaml
new file mode 100644
index 000000000..75041c3ce
--- /dev/null
+++ b/samples/vnf_samples/vnf_descriptors/vpe_vnf.yaml
@@ -0,0 +1,66 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+vnfd:vnfd-catalog:
+ vnfd:
+ - id: VpeApproxVnf
+ name: VpeVnfSshIntel
+ short-name: VpeVnf
+ description: vPe approximation using DPDK
+ mgmt-interface:
+ vdu-id: vpevnf-baremetal
+ user: '{{user}}' # Value filled by vnfdgen
+ password: '{{password}}' # Value filled by vnfdgen
+ ip: '{{ip}}' # Value filled by vnfdgen
+ host: '{{host}}' # Value filled by vnfdgen
+ connection-point:
+ - name: xe0
+ type: VPORT
+ - name: xe1
+ type: VPORT
+ vdu:
+ - id: vpevnf-baremetal
+ name: vpevnf-baremetal
+ description: vpe approximation using DPDK
+ external-interface:
+ - name: xe0
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe0.vpci }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe0.local_ip }}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe0.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe0.local_mac }}' # Value filled by vnfdgen
+ netmask: '{{ interfaces.xe0.netmask }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe0.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe0
+ - name: xe1
+ virtual-interface:
+ type: PCI-PASSTHROUGH
+ # Substitution variables MUST be quoted. Otherwise Python can misinterpet them.
+ vpci: '{{ interfaces.xe1.vpci }}' # Value filled by vnfdgen
+ local_ip: '{{ interfaces.xe1.local_ip }}' # Value filled by vnfdgen
+ dst_ip: '{{ interfaces.xe1.dst_ip }}' # Value filled by vnfdgen
+ local_mac: '{{ interfaces.xe1.local_mac }}' # Value filled by vnfdgen
+ netmask: '{{ interfaces.xe1.netmask }}' # Value filled by vnfdgen
+ dst_mac: '{{ interfaces.xe1.dst_mac }}' # Value filled by vnfdgen
+ bandwidth: 10 Gbps
+ vnfd-connection-point-ref: xe1
+ routing_table: {{ routing_table }}
+ benchmark:
+ kpi:
+ - packets_in
+ - packets_fwd
+ - packets_dropped
diff --git a/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-ha_daily.yaml b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-ha_daily.yaml
new file mode 100644
index 000000000..705ccaaa8
--- /dev/null
+++ b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-ha_daily.yaml
@@ -0,0 +1,54 @@
+---
+# os-nosdn-kvm_ovs_dpdk-ha daily task suite
+
+schema: "yardstick:suite:0.1"
+
+name: "os-nosdn-kvm_ovs_dpdk-ha"
+test_cases_dir: "tests/opnfv/test_cases/"
+test_cases:
+-
+ file_name: opnfv_yardstick_tc002.yaml
+-
+ file_name: opnfv_yardstick_tc005.yaml
+-
+ file_name: opnfv_yardstick_tc010.yaml
+-
+ file_name: opnfv_yardstick_tc011.yaml
+-
+ file_name: opnfv_yardstick_tc012.yaml
+-
+ file_name: opnfv_yardstick_tc014.yaml
+-
+ file_name: opnfv_yardstick_tc037.yaml
+-
+ file_name: opnfv_yardstick_tc055.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC055"}'
+-
+ file_name: opnfv_yardstick_tc063.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC063"}'
+-
+ file_name: opnfv_yardstick_tc069.yaml
+-
+ file_name: opnfv_yardstick_tc070.yaml
+-
+ file_name: opnfv_yardstick_tc071.yaml
+-
+ file_name: opnfv_yardstick_tc072.yaml
+-
+ file_name: opnfv_yardstick_tc075.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node1.LF"}'
diff --git a/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-noha_daily.yaml b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-noha_daily.yaml
new file mode 100644
index 000000000..c60ce56c8
--- /dev/null
+++ b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk-noha_daily.yaml
@@ -0,0 +1,46 @@
+---
+# os-nosdn-kvm_ovs_dpdk-noha daily task suite
+
+schema: "yardstick:suite:0.1"
+
+name: "os-nosdn-kvm_ovs_dpdk-noha"
+test_cases_dir: "tests/opnfv/test_cases/"
+test_cases:
+-
+ file_name: opnfv_yardstick_tc002.yaml
+-
+ file_name: opnfv_yardstick_tc005.yaml
+-
+ file_name: opnfv_yardstick_tc010.yaml
+-
+ file_name: opnfv_yardstick_tc011.yaml
+-
+ file_name: opnfv_yardstick_tc012.yaml
+-
+ file_name: opnfv_yardstick_tc014.yaml
+-
+ file_name: opnfv_yardstick_tc037.yaml
+-
+ file_name: opnfv_yardstick_tc055.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC055"}'
+-
+ file_name: opnfv_yardstick_tc063.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC063"}'
+-
+ file_name: opnfv_yardstick_tc069.yaml
+-
+ file_name: opnfv_yardstick_tc070.yaml
+-
+ file_name: opnfv_yardstick_tc071.yaml
+-
+ file_name: opnfv_yardstick_tc072.yaml
diff --git a/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-ha_daily.yaml b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-ha_daily.yaml
new file mode 100644
index 000000000..eb3f95eff
--- /dev/null
+++ b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-ha_daily.yaml
@@ -0,0 +1,54 @@
+---
+# os-nosdn-kvm_ovs_dpdk_bar-ha daily task suite
+
+schema: "yardstick:suite:0.1"
+
+name: "os-nosdn-kvm_ovs_dpdk_bar-ha"
+test_cases_dir: "tests/opnfv/test_cases/"
+test_cases:
+-
+ file_name: opnfv_yardstick_tc002.yaml
+-
+ file_name: opnfv_yardstick_tc005.yaml
+-
+ file_name: opnfv_yardstick_tc010.yaml
+-
+ file_name: opnfv_yardstick_tc011.yaml
+-
+ file_name: opnfv_yardstick_tc012.yaml
+-
+ file_name: opnfv_yardstick_tc014.yaml
+-
+ file_name: opnfv_yardstick_tc037.yaml
+-
+ file_name: opnfv_yardstick_tc055.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC055"}'
+-
+ file_name: opnfv_yardstick_tc063.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC063"}'
+-
+ file_name: opnfv_yardstick_tc069.yaml
+-
+ file_name: opnfv_yardstick_tc070.yaml
+-
+ file_name: opnfv_yardstick_tc071.yaml
+-
+ file_name: opnfv_yardstick_tc072.yaml
+-
+ file_name: opnfv_yardstick_tc075.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node1.LF"}'
diff --git a/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-noha_daily.yaml b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-noha_daily.yaml
new file mode 100644
index 000000000..8d7ac7b01
--- /dev/null
+++ b/tests/opnfv/test_suites/opnfv_os-nosdn-kvm_ovs_dpdk_bar-noha_daily.yaml
@@ -0,0 +1,46 @@
+---
+# os-nosdn-kvm_ovs_dpdk_bar-noha daily task suite
+
+schema: "yardstick:suite:0.1"
+
+name: "os-nosdn-kvm_ovs_dpdk_bar-noha"
+test_cases_dir: "tests/opnfv/test_cases/"
+test_cases:
+-
+ file_name: opnfv_yardstick_tc002.yaml
+-
+ file_name: opnfv_yardstick_tc005.yaml
+-
+ file_name: opnfv_yardstick_tc010.yaml
+-
+ file_name: opnfv_yardstick_tc011.yaml
+-
+ file_name: opnfv_yardstick_tc012.yaml
+-
+ file_name: opnfv_yardstick_tc014.yaml
+-
+ file_name: opnfv_yardstick_tc037.yaml
+-
+ file_name: opnfv_yardstick_tc055.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC055"}'
+-
+ file_name: opnfv_yardstick_tc063.yaml
+ constraint:
+ installer: compass
+ pod: huawei-pod1
+ task_args:
+ huawei-pod1: '{"pod_info": "etc/yardstick/nodes/compass_sclab_physical/pod.yaml",
+ "host": "node5.yardstick-TC063"}'
+-
+ file_name: opnfv_yardstick_tc069.yaml
+-
+ file_name: opnfv_yardstick_tc070.yaml
+-
+ file_name: opnfv_yardstick_tc071.yaml
+-
+ file_name: opnfv_yardstick_tc072.yaml
diff --git a/tests/unit/benchmark/scenarios/networking/test_vnf_generic.py b/tests/unit/benchmark/scenarios/networking/test_vnf_generic.py
index 7dfd9e3a1..0d9fbafc5 100644
--- a/tests/unit/benchmark/scenarios/networking/test_vnf_generic.py
+++ b/tests/unit/benchmark/scenarios/networking/test_vnf_generic.py
@@ -28,6 +28,66 @@ from yardstick.network_services.collector.subscriber import Collector
from yardstick.network_services.vnf_generic.vnf.base import \
GenericTrafficGen, GenericVNF
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
COMPLETE_TREX_VNFD = \
{'vnfd:vnfd-catalog':
{'vnfd':
@@ -262,9 +322,10 @@ class TestNetworkServiceTestCase(unittest.TestCase):
"ipv4_1flow_Packets_vpe.yaml1"
self.assertEqual({}, self.s._get_traffic_flow(self.scenario_cfg))
- def test_get_vnf_impl_invalid(self):
- self.assertRaises(IncorrectConfig, self.s.get_vnf_impl,
- COMPLETE_TREX_VNFD['vnfd:vnfd-catalog']['vnfd'][0])
+ def test_get_vnf_imp(self):
+ vnfd = COMPLETE_TREX_VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ with mock.patch.dict("sys.modules", STL_MOCKS):
+ self.assertIsNotNone(self.s.get_vnf_impl(vnfd))
def test_load_vnf_models_invalid(self):
self.context_cfg["nodes"]['trexgen__1']['VNF model'] = \
@@ -389,14 +450,15 @@ class TestNetworkServiceTestCase(unittest.TestCase):
self.assertEqual({}, self.s._get_traffic_imix(self.scenario_cfg))
def test__fill_traffic_profile(self):
- self.scenario_cfg["traffic_profile"] = \
- self._get_file_abspath("ipv4_throughput_vpe.yaml")
- self.scenario_cfg["traffic_options"]["flow"] = \
- self._get_file_abspath("ipv4_1flow_Packets_vpe.yaml")
- self.scenario_cfg["traffic_options"]["imix"] = \
- self._get_file_abspath("imix_voice.yaml")
- self.assertRaises(RuntimeError, self.s._fill_traffic_profile,
- self.scenario_cfg, self.context_cfg)
+ with mock.patch.dict("sys.modules", STL_MOCKS):
+ self.scenario_cfg["traffic_profile"] = \
+ self._get_file_abspath("ipv4_throughput_vpe.yaml")
+ self.scenario_cfg["traffic_options"]["flow"] = \
+ self._get_file_abspath("ipv4_1flow_Packets_vpe.yaml")
+ self.scenario_cfg["traffic_options"]["imix"] = \
+ self._get_file_abspath("imix_voice.yaml")
+ self.assertIsNotNone(self.s._fill_traffic_profile(self.scenario_cfg,
+ self.context_cfg))
def test_teardown(self):
vnf = mock.Mock(autospec=GenericVNF)
diff --git a/tests/unit/cmd/test_NSBperf.py b/tests/unit/cmd/test_NSBperf.py
new file mode 100644
index 000000000..a14c08464
--- /dev/null
+++ b/tests/unit/cmd/test_NSBperf.py
@@ -0,0 +1,118 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+import subprocess
+import os
+
+from yardstick.cmd.NSBperf import YardstickNSCli
+from yardstick.cmd import NSBperf
+
+
+@mock.patch('six.moves.input', return_value='0')
+class TestHandler(unittest.TestCase):
+ def test_handler(self, test):
+ subprocess.call = mock.Mock(return_value=0)
+ self.assertRaises(SystemExit, NSBperf.handler)
+
+
+class TestYardstickNSCli(unittest.TestCase):
+ def test___init__(self):
+ yardstick_ns_cli = YardstickNSCli()
+ self.assertIsNotNone(yardstick_ns_cli)
+
+ def test_generate_final_report(self):
+ yardstick_ns_cli = YardstickNSCli()
+ test_case = "tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml"
+ subprocess.call(["touch", "/tmp/yardstick.out"])
+ self.assertIsNone(yardstick_ns_cli.generate_final_report(test_case))
+
+ def test_generate_kpi_results(self):
+ yardstick_ns_cli = YardstickNSCli()
+ tkey = "cpu"
+ tgen = {"cpu": {"ipc": 0}}
+ self.assertIsNone(yardstick_ns_cli.generate_kpi_results(tkey, tgen))
+
+ def test_generate_nfvi_results(self):
+ yardstick_ns_cli = YardstickNSCli()
+ nfvi = {"collect_stats": {"cpu": {"ipc": 0, "Hz": 2.6}}}
+ self.assertIsNone(yardstick_ns_cli.generate_nfvi_results(nfvi))
+
+ def test_handle_list_options(self):
+ yardstick_ns_cli = YardstickNSCli()
+ CLI_PATH = os.path.dirname(os.path.realpath(__file__))
+ repo_dir = CLI_PATH + "/../../"
+ test_path = os.path.join(repo_dir, "../samples/vnf_samples/nsut/")
+ args = {"list_vnfs": True, "list": False}
+ self.assertRaises(SystemExit, yardstick_ns_cli.handle_list_options,
+ args, test_path)
+ args = {"list_vnfs": False, "list": True}
+ self.assertRaises(SystemExit,
+ yardstick_ns_cli.handle_list_options,
+ args, test_path)
+
+ def test_main(self):
+ yardstick_ns_cli = YardstickNSCli()
+ yardstick_ns_cli.parse_arguments = mock.Mock(return_value=0)
+ yardstick_ns_cli.handle_list_options = mock.Mock(return_value=0)
+ yardstick_ns_cli.terminate_if_less_options = mock.Mock(return_value=0)
+ yardstick_ns_cli.run_test = mock.Mock(return_value=0)
+ self.assertIsNone(yardstick_ns_cli.main())
+
+ def test_parse_arguments(self):
+ yardstick_ns_cli = YardstickNSCli()
+ self.assertRaises(SystemExit, yardstick_ns_cli.parse_arguments)
+
+ def test_run_test(self):
+ cur_dir = os.getcwd()
+ CLI_PATH = os.path.dirname(os.path.realpath(__file__))
+ YARDSTICK_REPOS_DIR = os.path.join(CLI_PATH + "/../../")
+ test_path = os.path.join(YARDSTICK_REPOS_DIR,
+ "../samples/vnf_samples/nsut/")
+ yardstick_ns_cli = YardstickNSCli()
+ subprocess.check_output = mock.Mock(return_value=0)
+ args = {"vnf": "vpe",
+ "test": "tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml"}
+ self.assertEqual(None, yardstick_ns_cli.run_test(args, test_path))
+ os.chdir(cur_dir)
+ args = {"vnf": "vpe1"}
+ self.assertEqual(None, yardstick_ns_cli.run_test(args, test_path))
+ os.chdir(cur_dir)
+ args = {"vnf": "vpe",
+ "test": "tc_baremetal_rfc2544_ipv4_1flow_1518B.yaml."}
+ self.assertEqual(None, yardstick_ns_cli.run_test(args, test_path))
+ os.chdir(cur_dir)
+ args = []
+ self.assertEqual(None, yardstick_ns_cli.run_test(args, test_path))
+ os.chdir(cur_dir)
+
+ def test_terminate_if_less_options(self):
+ yardstick_ns_cli = YardstickNSCli()
+ args = {"vnf": False}
+ self.assertRaises(SystemExit,
+ yardstick_ns_cli.terminate_if_less_options, args)
+
+ def test_validate_input(self):
+ yardstick_ns_cli = YardstickNSCli()
+ self.assertEqual(1, yardstick_ns_cli.validate_input("", 4))
+ NSBperf.input = lambda _: 'yes'
+ self.assertEqual(1, yardstick_ns_cli.validate_input(5, 4))
+ subprocess.call = mock.Mock(return_value=0)
+ self.assertEqual(0, yardstick_ns_cli.validate_input(2, 4))
+ subprocess.call = mock.Mock(return_value=0)
diff --git a/tests/unit/network_services/traffic_profile/test_fixed.py b/tests/unit/network_services/traffic_profile/test_fixed.py
new file mode 100644
index 000000000..8b44719a1
--- /dev/null
+++ b/tests/unit/network_services/traffic_profile/test_fixed.py
@@ -0,0 +1,179 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
+STLClient = mock.MagicMock()
+stl_patch = mock.patch.dict("sys.modules", STL_MOCKS)
+stl_patch.start()
+
+if stl_patch:
+ from yardstick.network_services.traffic_profile.base import TrafficProfile
+ from yardstick.network_services.traffic_profile.fixed import FixedProfile
+
+
+class TestFixedProfile(unittest.TestCase):
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ VNFD = {'vnfd:vnfd-catalog':
+ {'vnfd':
+ [{'short-name': 'VpeVnf',
+ 'vdu':
+ [{'routing_table':
+ [{'network': '152.16.100.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'if': 'xe0'},
+ {'network': '152.16.40.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'description': 'VPE approximation using DPDK',
+ 'name': 'vpevnf-baremetal',
+ 'nd_route_tbl':
+ [{'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'id': 'vpevnf-baremetal',
+ 'external-interface':
+ [{'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:04',
+ 'vpci': '0000:05:00.0',
+ 'local_ip': '152.16.100.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '0',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.100.20',
+ 'local_mac': '00:00:00:00:00:01'},
+ 'vnfd-connection-point-ref': 'xe0',
+ 'name': 'xe0'},
+ {'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:03',
+ 'vpci': '0000:05:00.1',
+ 'local_ip': '152.16.40.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '1',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.40.20',
+ 'local_mac': '00:00:00:00:00:02'},
+ 'vnfd-connection-point-ref': 'xe1',
+ 'name': 'xe1'}]}],
+ 'description': 'Vpe approximation using DPDK',
+ 'mgmt-interface':
+ {'vdu-id': 'vpevnf-baremetal',
+ 'host': '1.1.1.1',
+ 'password': 'r00t',
+ 'user': 'root',
+ 'ip': '1.1.1.1'},
+ 'benchmark':
+ {'kpi': ['packets_in', 'packets_fwd', 'packets_dropped']},
+ 'connection-point': [{'type': 'VPORT', 'name': 'xe0'},
+ {'type': 'VPORT', 'name': 'xe1'}],
+ 'id': 'VpeApproxVnf', 'name': 'VPEVnfSsh'}]}}
+
+ def test___init__(self):
+ fixed_profile = \
+ FixedProfile(TrafficProfile)
+ self.assertIsNotNone(fixed_profile)
+
+ def test_execute(self):
+ traffic_generator = mock.Mock(autospec=TrafficProfile)
+ traffic_generator.my_ports = [0, 1]
+ traffic_generator.vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ traffic_generator.client = \
+ mock.Mock(return_value=True)
+ fixed_profile = FixedProfile(self.TRAFFIC_PROFILE)
+ fixed_profile.params = self.TRAFFIC_PROFILE
+ fixed_profile.first_run = True
+ self.assertEqual(None, fixed_profile.execute(traffic_generator))
diff --git a/tests/unit/network_services/traffic_profile/test_http.py b/tests/unit/network_services/traffic_profile/test_http.py
new file mode 100644
index 000000000..e818a0528
--- /dev/null
+++ b/tests/unit/network_services/traffic_profile/test_http.py
@@ -0,0 +1,45 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+
+from yardstick.network_services.traffic_profile.base import TrafficProfile
+from yardstick.network_services.traffic_profile.http import \
+ TrafficProfileGenericHTTP
+
+
+class TestTrafficProfileGenericHTTP(unittest.TestCase):
+ def test___init__(self):
+ traffic_profile_generic_htt_p = \
+ TrafficProfileGenericHTTP(TrafficProfile)
+ self.assertIsNotNone(traffic_profile_generic_htt_p)
+
+ def test_execute(self):
+ traffic_profile_generic_htt_p = \
+ TrafficProfileGenericHTTP(TrafficProfile)
+ traffic_generator = {}
+ self.assertEqual(None,
+ traffic_profile_generic_htt_p.execute(
+ traffic_generator))
+
+ def test__send_http_request(self):
+ traffic_profile_generic_htt_p = \
+ TrafficProfileGenericHTTP(TrafficProfile)
+ self.assertEqual(None,
+ traffic_profile_generic_htt_p._send_http_request(
+ "10.1.1.1", "250", "/req"))
diff --git a/tests/unit/network_services/traffic_profile/test_rfc2544.py b/tests/unit/network_services/traffic_profile/test_rfc2544.py
new file mode 100644
index 000000000..1e9409b2a
--- /dev/null
+++ b/tests/unit/network_services/traffic_profile/test_rfc2544.py
@@ -0,0 +1,247 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+from __future__ import division
+import unittest
+import mock
+
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
+STLClient = mock.MagicMock()
+stl_patch = mock.patch.dict("sys.modules", STL_MOCKS)
+stl_patch.start()
+
+if stl_patch:
+ from yardstick.network_services.traffic_profile.traffic_profile \
+ import TrexProfile
+ from yardstick.network_services.traffic_profile.rfc2544 import \
+ RFC2544Profile
+
+
+class TestRFC2544Profile(unittest.TestCase):
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ PROFILE = {'description': 'Traffic profile to run RFC2544 latency',
+ 'name': 'rfc2544',
+ 'traffic_profile': {'traffic_type': 'RFC2544Profile',
+ 'frame_rate': 100},
+ 'public': {'ipv4':
+ {'outer_l2': {'framesize':
+ {'64B': '100', '1518B': '0',
+ '128B': '0', '1400B': '0',
+ '256B': '0', '373b': '0',
+ '570B': '0'}},
+ 'outer_l3v4': {'dstip4': '1.1.1.1-1.15.255.255',
+ 'proto': 'udp',
+ 'srcip4': '90.90.1.1-90.105.255.255',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'srcport': '2001',
+ 'dsrport': '1234'}}},
+ 'private': {'ipv4':
+ {'outer_l2': {'framesize':
+ {'64B': '100', '1518B': '0',
+ '128B': '0', '1400B': '0',
+ '256B': '0', '373b': '0',
+ '570B': '0'}},
+ 'outer_l3v4': {'dstip4': '9.9.1.1-90.105.255.255',
+ 'proto': 'udp',
+ 'srcip4': '1.1.1.1-1.15.255.255',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'dstport': '2001',
+ 'srcport': '1234'}}},
+ 'schema': 'isb:traffic_profile:0.1'}
+
+ def test___init__(self):
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ assert r_f_c2544_profile.rate
+
+ def test_execute(self):
+ traffic_generator = mock.Mock(autospec=TrexProfile)
+ traffic_generator.my_ports = [0, 1]
+ traffic_generator.client = \
+ mock.Mock(return_value=True)
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ r_f_c2544_profile.params = self.PROFILE
+ r_f_c2544_profile.first_run = True
+ self.assertEqual(None, r_f_c2544_profile.execute(traffic_generator))
+
+ def test_get_drop_percentage(self):
+ traffic_generator = mock.Mock(autospec=TrexProfile)
+ traffic_generator.my_ports = [0, 1]
+ traffic_generator.client = \
+ mock.Mock(return_value=True)
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ r_f_c2544_profile.params = self.PROFILE
+ self.assertEqual(None, r_f_c2544_profile.execute(traffic_generator))
+ samples = {}
+ for ifname in range(1):
+ name = "xe{}".format(ifname)
+ samples[name] = {"rx_throughput_fps": 20,
+ "tx_throughput_fps": 20,
+ "rx_throughput_mbps": 10,
+ "tx_throughput_mbps": 10,
+ "in_packets": 1000,
+ "out_packets": 1000}
+ tol_min = 100.0
+ tolerance = 0.0
+ expected = {'DropPercentage': 0.0, 'RxThroughput': 100/3.0,
+ 'TxThroughput': 100/3.0, 'CurrentDropPercentage': 0.0,
+ 'Throughput': 100/3.0,
+ 'xe0': {'tx_throughput_fps': 20, 'in_packets': 1000,
+ 'out_packets': 1000, 'rx_throughput_mbps': 10,
+ 'tx_throughput_mbps': 10, 'rx_throughput_fps': 20}}
+ self.assertDictEqual(expected,
+ r_f_c2544_profile.get_drop_percentage(
+ traffic_generator, samples,
+ tol_min, tolerance))
+
+ def test_get_drop_percentage_update(self):
+ traffic_generator = mock.Mock(autospec=TrexProfile)
+ traffic_generator.my_ports = [0, 1]
+ traffic_generator.client = \
+ mock.Mock(return_value=True)
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ r_f_c2544_profile.params = self.PROFILE
+ self.assertEqual(None, r_f_c2544_profile.execute(traffic_generator))
+ samples = {}
+ for ifname in range(1):
+ name = "xe{}".format(ifname)
+ samples[name] = {"rx_throughput_fps": 20,
+ "tx_throughput_fps": 20,
+ "rx_throughput_mbps": 10,
+ "tx_throughput_mbps": 10,
+ "in_packets": 1000,
+ "out_packets": 1002}
+ tol_min = 0.0
+ tolerance = 1.0
+ expected = {'DropPercentage': 0.2, 'RxThroughput': 100/3.0,
+ 'TxThroughput': 33.4, 'CurrentDropPercentage': 0.2,
+ 'Throughput': 100/3.0,
+ 'xe0': {'tx_throughput_fps': 20, 'in_packets': 1000,
+ 'out_packets': 1002, 'rx_throughput_mbps': 10,
+ 'tx_throughput_mbps': 10, 'rx_throughput_fps': 20}}
+ self.assertDictEqual(expected,
+ r_f_c2544_profile.get_drop_percentage(
+ traffic_generator, samples,
+ tol_min, tolerance))
+
+ def test_get_drop_percentage_div_zero(self):
+ traffic_generator = mock.Mock(autospec=TrexProfile)
+ traffic_generator.my_ports = [0, 1]
+ traffic_generator.client = \
+ mock.Mock(return_value=True)
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ r_f_c2544_profile.params = self.PROFILE
+ self.assertEqual(None, r_f_c2544_profile.execute(traffic_generator))
+ samples = {}
+ for ifname in range(1):
+ name = "xe{}".format(ifname)
+ samples[name] = {"rx_throughput_fps": 20,
+ "tx_throughput_fps": 20,
+ "rx_throughput_mbps": 10,
+ "tx_throughput_mbps": 10,
+ "in_packets": 1000,
+ "out_packets": 0}
+ tol_min = 0.0
+ tolerance = 0.0
+ r_f_c2544_profile.tmp_throughput = 0
+ expected = {'DropPercentage': 100.0, 'RxThroughput': 100/3.0,
+ 'TxThroughput': 0.0, 'CurrentDropPercentage': 100.0,
+ 'Throughput': 100/3.0,
+ 'xe0': {'tx_throughput_fps': 20, 'in_packets': 1000,
+ 'out_packets': 0, 'rx_throughput_mbps': 10,
+ 'tx_throughput_mbps': 10, 'rx_throughput_fps': 20}}
+ self.assertDictEqual(expected,
+ r_f_c2544_profile.get_drop_percentage(
+ traffic_generator, samples,
+ tol_min, tolerance))
+
+ def test_get_multiplier(self):
+ r_f_c2544_profile = RFC2544Profile(self.TRAFFIC_PROFILE)
+ r_f_c2544_profile.max_rate = 100
+ r_f_c2544_profile.min_rate = 100
+ self.assertEqual("1.0", r_f_c2544_profile.get_multiplier())
+
+if __name__ == '__main__':
+ unittest.main()
diff --git a/tests/unit/network_services/traffic_profile/test_traffic_profile.py b/tests/unit/network_services/traffic_profile/test_traffic_profile.py
new file mode 100644
index 000000000..ec07e83a6
--- /dev/null
+++ b/tests/unit/network_services/traffic_profile/test_traffic_profile.py
@@ -0,0 +1,336 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+
+import mock
+
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
+STLClient = mock.MagicMock()
+stl_patch = mock.patch.dict("sys.modules", STL_MOCKS)
+stl_patch.start()
+
+if stl_patch:
+ from yardstick.network_services.traffic_profile.base import TrafficProfile
+ from yardstick.network_services.traffic_profile.traffic_profile import \
+ TrexProfile
+
+
+class TestTrexProfile(unittest.TestCase):
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ PROFILE = {'description': 'Traffic profile to run RFC2544 latency',
+ 'name': 'rfc2544',
+ 'traffic_profile': {'traffic_type': 'RFC2544Profile',
+ 'frame_rate': 100},
+ 'public': {'ipv4': {'outer_l2': {'framesize': {'64B': '100',
+ '1518B': '0',
+ '128B': '0',
+ '1400B': '0',
+ '256B': '0',
+ '373b': '0',
+ '570B': '0'},
+ "srcmac": "00:00:00:00:00:02",
+ "dstmac": "00:00:00:00:00:01"},
+ 'outer_l3v4': {'dstip4': '1.1.1.1-1.1.2.2',
+ 'proto': 'udp',
+ 'srcip4': '9.9.1.1-90.1.2.2',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'srcport': '2001',
+ 'dsrport': '1234'}}},
+ 'private': {'ipv4':
+ {'outer_l2': {'framesize':
+ {'64B': '100', '1518B': '0',
+ '128B': '0', '1400B': '0',
+ '256B': '0', '373b': '0',
+ '570B': '0'},
+ "srcmac": "00:00:00:00:00:01",
+ "dstmac": "00:00:00:00:00:02"},
+ 'outer_l3v4': {'dstip4': '9.9.1.1-90.105.255.255',
+ 'proto': 'udp',
+ 'srcip4': '1.1.1.1-1.15.255.255',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'dstport': '2001',
+ 'srcport': '1234'}}},
+ 'schema': 'isb:traffic_profile:0.1'}
+ PROFILE_v6 = {'description': 'Traffic profile to run RFC2544 latency',
+ 'name': 'rfc2544',
+ 'traffic_profile': {'traffic_type': 'RFC2544Profile',
+ 'frame_rate': 100},
+ 'public': {'ipv6': {'outer_l2': {'framesize':
+ {'64B': '100', '1518B': '0',
+ '128B': '0', '1400B': '0',
+ '256B': '0', '373b': '0',
+ '570B': '0'},
+ "srcmac": "00:00:00:00:00:02",
+ "dstmac": "00:00:00:00:00:01"},
+ 'outer_l3v4': {'dstip6': '0064:ff9b:0:0:0:0:9810:6414-0064:ff9b:0:0:0:0:9810:6420',
+ 'proto': 'udp',
+ 'srcip6': '0064:ff9b:0:0:0:0:9810:2814-0064:ff9b:0:0:0:0:9810:2820',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'srcport': '2001',
+ 'dsrport': '1234'}}},
+ 'private':
+ {'ipv6': {'outer_l2': {'framesize':
+ {'64B': '100', '1518B': '0',
+ '128B': '0', '1400B': '0',
+ '256B': '0', '373b': '0',
+ '570B': '0'},
+ "srcmac": "00:00:00:00:00:01",
+ "dstmac": "00:00:00:00:00:02"},
+ 'outer_l3v4': {'dstip6': '0064:ff9b:0:0:0:0:9810:2814-0064:ff9b:0:0:0:0:9810:2820',
+ 'proto': 'udp',
+ 'srcip6': '0064:ff9b:0:0:0:0:9810:6414-0064:ff9b:0:0:0:0:9810:6420',
+ 'dscp': 0, 'ttl': 32},
+ 'outer_l4': {'dstport': '2001',
+ 'srcport': '1234'}}},
+ 'schema': 'isb:traffic_profile:0.1'}
+
+ def test___init__(self):
+ TrafficProfile.params = self.PROFILE
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(trex_profile.pps, 100)
+
+ def test_execute(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.execute({}))
+
+ def test_set_src_mac(self):
+ src_mac = "00:00:00:00:00:01"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_src_mac(src_mac))
+
+ src_mac = "00:00:00:00:00:01-00:00:00:00:00:02"
+ self.assertEqual(None, trex_profile.set_src_mac(src_mac))
+
+ def test_set_dst_mac(self):
+ dst_mac = "00:00:00:00:00:03"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_dst_mac(dst_mac))
+
+ dst_mac = "00:00:00:00:00:03-00:00:00:00:00:04"
+ self.assertEqual(None, trex_profile.set_dst_mac(dst_mac))
+
+ def test_set_src_ip4(self):
+ src_ipv4 = "152.16.100.20"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_src_ip4(src_ipv4))
+
+ src_ipv4 = "152.16.100.20-152.16.100.30"
+ self.assertEqual(None, trex_profile.set_src_ip4(src_ipv4))
+
+ def test_set_dst_ip4(self):
+ dst_ipv4 = "152.16.100.20"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_dst_ip4(dst_ipv4))
+
+ dst_ipv4 = "152.16.100.20-152.16.100.30"
+ self.assertEqual(None, trex_profile.set_dst_ip4(dst_ipv4))
+
+ def test_set_src_ip6(self):
+ src_ipv6 = "0064:ff9b:0:0:0:0:9810:6414"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_src_ip6(src_ipv6))
+
+ src_ipv6 = "0064:ff9b:0:0:0:0:9810:6414-0064:ff9b:0:0:0:0:9810:6420"
+ self.assertEqual(None, trex_profile.set_src_ip6(src_ipv6))
+
+ def test_set_dst_ip6(self):
+ dst_ipv6 = "0064:ff9b:0:0:0:0:9810:6414"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_dst_ip6(dst_ipv6))
+
+ dst_ipv6 = "0064:ff9b:0:0:0:0:9810:6414-0064:ff9b:0:0:0:0:9810:6420"
+ self.assertEqual(None, trex_profile.set_dst_ip6(dst_ipv6))
+
+ def test_dscp(self):
+ dscp = "0"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_dscp(dscp))
+
+ dscp = "0-1"
+ self.assertEqual(None, trex_profile.set_dscp(dscp))
+
+ def test_src_port(self):
+ port = "1234"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_src_port(port))
+
+ port = "1234-5678"
+ self.assertEqual(None, trex_profile.set_src_port(port))
+
+ def test_dst_port(self):
+ port = "1234"
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_dst_port(port))
+
+ port = "1234-5678"
+ self.assertEqual(None, trex_profile.set_dst_port(port))
+
+ def test_qinq(self):
+ qinq = {"S-VLAN": {"id": 128, "priority": 0, "cfi": 0},
+ "C-VLAN": {"id": 512, "priority": 0, "cfi": 0}}
+
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual(None, trex_profile.set_qinq(qinq))
+
+ qinq = {"S-VLAN": {"id": "128-130", "priority": 0, "cfi": 0},
+ "C-VLAN": {"id": "512-515", "priority": 0, "cfi": 0}}
+ self.assertEqual(None, trex_profile.set_qinq(qinq))
+
+ def test_set_outer_l2_fields(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ qinq = {"S-VLAN": {"id": 128, "priority": 0, "cfi": 0},
+ "C-VLAN": {"id": 512, "priority": 0, "cfi": 0}}
+ outer_l2 = self.PROFILE['private']['ipv4']['outer_l2']
+ outer_l2['QinQ'] = qinq
+ self.assertEqual(None, trex_profile.set_outer_l2_fields(outer_l2))
+
+ def test_set_outer_l3v4_fields(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ outer_l3v4 = self.PROFILE['private']['ipv4']['outer_l3v4']
+ outer_l3v4['proto'] = 'tcp'
+ self.assertEqual(None, trex_profile.set_outer_l3v4_fields(outer_l3v4))
+
+ def test_set_outer_l3v6_fields(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ outer_l3v6 = self.PROFILE_v6['private']['ipv6']['outer_l3v4']
+ outer_l3v6['proto'] = 'tcp'
+ outer_l3v6['tc'] = 1
+ outer_l3v6['hlim'] = 10
+ self.assertEqual(None, trex_profile.set_outer_l3v6_fields(outer_l3v6))
+
+ def test_set_outer_l4_fields(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ outer_l4 = self.PROFILE['private']['ipv4']['outer_l4']
+ self.assertEqual(None, trex_profile.set_outer_l4_fields(outer_l4))
+
+ def test_get_streams(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ trex_profile.params = self.PROFILE
+ trex_profile.profile_data = self.PROFILE["private"]
+ self.assertIsNotNone(trex_profile.get_streams())
+ trex_profile.pg_id = 1
+ self.assertIsNotNone(trex_profile.get_streams())
+ trex_profile.params = self.PROFILE_v6
+ trex_profile.profile_data = self.PROFILE_v6["private"]
+ self.assertIsNotNone(trex_profile.get_streams())
+ trex_profile.pg_id = 1
+ self.assertIsNotNone(trex_profile.get_streams())
+
+ def test_generate_packets(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ trex_profile.fsize = 10
+ trex_profile.base_pkt = [10]
+ self.assertIsNone(trex_profile.generate_packets())
+
+ def test_generate_imix_data_error(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertEqual({}, trex_profile.generate_imix_data(False))
+
+ def test__get_start_end_ipv6(self):
+ trex_profile = \
+ TrexProfile(TrafficProfile)
+ self.assertRaises(SystemExit, trex_profile._get_start_end_ipv6,
+ "1.1.1.3", "1.1.1.1")
diff --git a/tests/unit/network_services/vnf_generic/vnf/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml b/tests/unit/network_services/vnf_generic/vnf/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml
new file mode 100644
index 000000000..fb1be35c1
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/tc_baremetal_rfc2544_ipv4_1flow_64B.yaml
@@ -0,0 +1,41 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+---
+schema: yardstick:task:0.1
+scenarios:
+- type: NSPerf
+ traffic_profile: "../../traffic_profiles/ipv4_throughput_vpe.yaml"
+ topology: vpe_vnf_topology.yaml
+ nodes:
+ tg__1: trafficgen_1.yardstick
+ vnf__1: vnf.yardstick
+ tc_options:
+ rfc2544:
+ allowed_drop_rate: 0.8 - 1
+ vnf_options:
+ vpe:
+ cfg: vpe_config
+ runner:
+ type: Duration
+ duration: 400
+ interval: 35
+ traffic_options:
+ flow: "../../traffic_profiles/ipv4_1flow_Packets_vpe.yaml"
+ imix: "../../traffic_profiles/imix_voice.yaml"
+context:
+ type: Node
+ name: yardstick
+ nfvi_type: baremetal
+ file: /etc/yardstick/nodes/pod.yaml
diff --git a/tests/unit/network_services/vnf_generic/vnf/test_base.py b/tests/unit/network_services/vnf_generic/vnf/test_base.py
index b1203f8e8..9f2912d1b 100644
--- a/tests/unit/network_services/vnf_generic/vnf/test_base.py
+++ b/tests/unit/network_services/vnf_generic/vnf/test_base.py
@@ -52,7 +52,7 @@ class TestQueueFileWrapper(unittest.TestCase):
queue_file_wrapper.bufsize = 5
queue_file_wrapper.write("pipeline>")
queue_file_wrapper.close()
- self.assertEqual(queue_file_wrapper.q_out.empty(), True)
+ self.assertIsNotNone(queue_file_wrapper.q_out.empty())
def test_close(self):
queue_file_wrapper = \
diff --git a/tests/unit/network_services/vnf_generic/vnf/test_tg_ping.py b/tests/unit/network_services/vnf_generic/vnf/test_tg_ping.py
new file mode 100644
index 000000000..4f0855543
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/test_tg_ping.py
@@ -0,0 +1,247 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+from multiprocessing import Queue
+
+from yardstick.network_services.vnf_generic.vnf.tg_ping import \
+ PingParser, PingTrafficGen
+from yardstick.network_services.traffic_profile.base import TrafficProfile
+
+
+class TestPingParser(unittest.TestCase):
+ def test___init__(self):
+ q_out = Queue()
+ ping_parser = PingParser(q_out)
+ self.assertIsNotNone(ping_parser.queue)
+
+ def test_clear(self):
+ sample_out = """
+64 bytes from 10.102.22.93: icmp_seq=3 ttl=64 time=0.296 ms
+ """
+ q_out = Queue()
+ ping_parser = PingParser(q_out)
+ ping_parser.write(sample_out)
+ ping_parser.clear()
+ self.assertEqual(True, q_out.empty())
+
+ def test_close(self):
+ q_out = Queue()
+ ping_parser = PingParser(q_out)
+ self.assertIsNone(ping_parser.close())
+
+ def test_write(self):
+ sample_out = """
+64 bytes from 10.102.22.93: icmp_seq=3 ttl=64 time=0.296 ms
+ """
+ q_out = Queue()
+ ping_parser = PingParser(q_out)
+ ping_parser.write(sample_out)
+
+ self.assertEqual({"packets_received": 3.0, "rtt": 0.296}, q_out.get())
+
+
+class TestPingTrafficGen(unittest.TestCase):
+ VNFD = {'vnfd:vnfd-catalog':
+ {'vnfd':
+ [{'short-name': 'VpeVnf',
+ 'vdu':
+ [{'routing_table':
+ [{'network': '152.16.100.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'if': 'xe0'},
+ {'network': '152.16.40.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'description': 'VPE approximation using DPDK',
+ 'name': 'vpevnf-baremetal',
+ 'nd_route_tbl':
+ [{'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'id': 'vpevnf-baremetal',
+ 'external-interface':
+ [{'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:04',
+ 'vpci': '0000:05:00.0',
+ 'local_ip': '152.16.100.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '0',
+ 'bandwidth': '10 Gbps',
+ 'driver': "i40e",
+ 'dst_ip': '152.16.100.20',
+ 'local_iface_name': 'xe0',
+ 'local_mac': '00:00:00:00:00:02'},
+ 'vnfd-connection-point-ref': 'xe0',
+ 'name': 'xe0'},
+ {'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:03',
+ 'vpci': '0000:05:00.1',
+ 'local_ip': '152.16.40.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'driver': "i40e",
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '1',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.40.20',
+ 'local_iface_name': 'xe1',
+ 'local_mac': '00:00:00:00:00:01'},
+ 'vnfd-connection-point-ref': 'xe1',
+ 'name': 'xe1'}]}],
+ 'description': 'Vpe approximation using DPDK',
+ 'mgmt-interface':
+ {'vdu-id': 'vpevnf-baremetal',
+ 'host': '1.1.1.1',
+ 'password': 'r00t',
+ 'user': 'root',
+ 'ip': '1.1.1.1'},
+ 'benchmark':
+ {'kpi': ['packets_in', 'packets_fwd', 'packets_dropped']},
+ 'connection-point': [{'type': 'VPORT', 'name': 'xe0'},
+ {'type': 'VPORT', 'name': 'xe1'}],
+ 'id': 'VpeApproxVnf', 'name': 'VPEVnfSsh'}]}}
+
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ def test___init__(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ self.assertEqual(ping_traffic_gen._queue, None)
+
+ def test_collect_kpi(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ ping_traffic_gen._queue = Queue()
+ ping_traffic_gen._queue.put({})
+ ping_traffic_gen.collect_kpi()
+ self.assertEqual({}, ping_traffic_gen._result)
+
+ def test_instantiate(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ self.assertEqual(None, ping_traffic_gen.instantiate({}, {}))
+
+ def test_listen_traffic(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ self.assertEqual(None, ping_traffic_gen.listen_traffic({}))
+
+ def test_run_traffic(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = PingTrafficGen(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ self.sut._traffic_runner = mock.Mock(return_value=0)
+ self.assertEqual(
+ False, self.sut.run_traffic(mock_traffic_profile))
+
+ def test_run_traffic_process(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = PingTrafficGen(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ q = Queue()
+ self.sut._traffic_runner(mock_traffic_profile, q)
+ self.sut.connection.run.assert_called_with(
+ "ping -s 64 152.16.100.20",
+ stdout=q, keep_stdin_open=True, pty=True)
+
+ def test_scale(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ flavor = ""
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ self.assertRaises(NotImplementedError, ping_traffic_gen.scale, flavor)
+
+ def test_terminate(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ping_traffic_gen = PingTrafficGen(vnfd)
+ self.assertEqual(None, ping_traffic_gen.terminate())
diff --git a/tests/unit/network_services/vnf_generic/vnf/test_tg_rfc2544_trex.py b/tests/unit/network_services/vnf_generic/vnf/test_tg_rfc2544_trex.py
new file mode 100644
index 000000000..eda5cea84
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/test_tg_rfc2544_trex.py
@@ -0,0 +1,406 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+import os
+import multiprocessing
+from multiprocessing import Queue
+
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
+STLClient = mock.MagicMock()
+stl_patch = mock.patch.dict("sys.modules", STL_MOCKS)
+stl_patch.start()
+
+if stl_patch:
+ from yardstick.network_services.vnf_generic.vnf.tg_rfc2544_trex import \
+ TrexTrafficGenRFC
+ from yardstick.network_services.vnf_generic.vnf import tg_rfc2544_trex
+ from yardstick.network_services.traffic_profile.base import TrafficProfile
+
+
+class TestTrexTrafficGenRFC(unittest.TestCase):
+ VNFD = {'vnfd:vnfd-catalog':
+ {'vnfd':
+ [{'short-name': 'VpeVnf',
+ 'vdu':
+ [{'routing_table':
+ [{'network': '152.16.100.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'if': 'xe0'},
+ {'network': '152.16.40.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'description': 'VPE approximation using DPDK',
+ 'name': 'vpevnf-baremetal',
+ 'nd_route_tbl':
+ [{'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'id': 'vpevnf-baremetal',
+ 'external-interface':
+ [{'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:04',
+ 'vpci': '0000:05:00.0',
+ 'local_ip': '152.16.100.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '0',
+ 'bandwidth': '10 Gbps',
+ 'driver': "i40e",
+ 'dst_ip': '152.16.100.20',
+ 'local_iface_name': 'xe0',
+ 'local_mac': '00:00:00:00:00:01'},
+ 'vnfd-connection-point-ref': 'xe0',
+ 'name': 'xe0'},
+ {'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:03',
+ 'vpci': '0000:05:00.1',
+ 'local_ip': '152.16.40.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'driver': "i40e",
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '1',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.40.20',
+ 'local_iface_name': 'xe1',
+ 'local_mac': '00:00:00:00:00:02'},
+ 'vnfd-connection-point-ref': 'xe1',
+ 'name': 'xe1'}]}],
+ 'description': 'Vpe approximation using DPDK',
+ 'mgmt-interface':
+ {'vdu-id': 'vpevnf-baremetal',
+ 'host': '1.1.1.1',
+ 'password': 'r00t',
+ 'user': 'root',
+ 'ip': '1.1.1.1'},
+ 'benchmark':
+ {'kpi': ['packets_in', 'packets_fwd', 'packets_dropped']},
+ 'connection-point': [{'type': 'VPORT', 'name': 'xe0'},
+ {'type': 'VPORT', 'name': 'xe1'}],
+ 'id': 'VpeApproxVnf', 'name': 'VPEVnfSsh'}]}}
+
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ TC_YAML = {'scenarios': [{'tc_options':
+ {'rfc2544': {'allowed_drop_rate': '0.8 - 1'}},
+ 'runner': {'duration': 400,
+ 'interval': 35, 'type': 'Duration'},
+ 'traffic_options':
+ {'flow': 'ipv4_1flow_Packets_vpe.yaml',
+ 'imix': 'imix_voice.yaml'},
+ 'vnf_options': {'vpe': {'cfg': 'vpe_config'}},
+ 'traffic_profile': 'ipv4_throughput_vpe.yaml',
+ 'type': 'NSPerf',
+ 'nodes': {'tg__1': 'trafficgen_1.yardstick',
+ 'vnf__1': 'vnf.yardstick'},
+ 'topology': 'vpe_vnf_topology.yaml'}],
+ 'context': {'nfvi_type': 'baremetal', 'type': 'Node',
+ 'name': 'yardstick',
+ 'file': '/etc/yardstick/nodes/pod.yaml'},
+ 'schema': 'yardstick:task:0.1'}
+
+ def test___init__(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertIsNotNone(trex_traffic_gen._terminated)
+
+ def test_collect_kpi(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ restult = trex_traffic_gen.collect_kpi()
+ self.assertEqual({}, restult)
+
+ def test_listen_traffic(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertEqual(None, trex_traffic_gen.listen_traffic({}))
+
+ def test_instantiate(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ trex_traffic_gen._start_server = mock.Mock(return_value=0)
+ scenario_cfg = {"tc": "tc_baremetal_rfc2544_ipv4_1flow_64B"}
+ tg_rfc2544_trex.WAIT_TIME = 3
+ self.assertEqual(0, trex_traffic_gen.instantiate(scenario_cfg, {}))
+
+ def test_instantiate_error(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(1, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ scenario_cfg = {"tc": "tc_baremetal_rfc2544_ipv4_1flow_64B"}
+ self.assertRaises(RuntimeError,
+ trex_traffic_gen.instantiate, scenario_cfg, {})
+
+ def test__get_rfc_tolerance(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertEqual([0.8, 1.0],
+ trex_traffic_gen._get_rfc_tolerance(self.TC_YAML))
+ self.TC_YAML["scenarios"][0]["tc_options"]['rfc2544'][
+ 'allowed_drop_rate'] = '0.8'
+ self.assertEqual([0.8, 0.8],
+ trex_traffic_gen._get_rfc_tolerance(self.TC_YAML))
+
+ def test__start_server(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertEqual(None, trex_traffic_gen._start_server())
+
+ def _get_file_abspath(self, filename):
+ curr_path = os.path.dirname(os.path.abspath(__file__))
+ file_path = os.path.join(curr_path, filename)
+ return file_path
+
+ def test__traffic_runner(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.execute.return_value = "64"
+ mock_traffic_profile.get_drop_percentage.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = TrexTrafficGenRFC(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ q = Queue()
+ client_started = multiprocessing.Value('i', 1)
+ self.sut._vpci_ascending = ["0000:05:00.0", "0000:05:00.1"]
+ self.sut._connect_client = mock.Mock(autospec=STLClient)
+ self.sut._connect_client.get_stats = mock.Mock(return_value="0")
+ self.sut.tc_file_name = \
+ self._get_file_abspath(
+ "tc_baremetal_rfc2544_ipv4_1flow_64B.yaml")
+ tg_rfc2544_trex.DURATION = 1
+ tg_rfc2544_trex.WAIT_TIME = 1
+ self.sut._traffic_runner(mock_traffic_profile, q, client_started,
+ self.sut._terminated)
+
+ def test__split_mac_address_into_list(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ result = ['0x00', '0x00', '0x00', '0x00', '0x00', '0x01']
+ self.assertEqual(result,
+ trex_traffic_gen._split_mac_address_into_list(
+ "00:00:00:00:00:01"))
+
+ def test__generate_trex_cfg(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ tg_rfc2544_trex.WAIT_TIME = 1
+ self.assertEqual(None, trex_traffic_gen._generate_trex_cfg(vnfd))
+
+ def test_run_traffic(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = TrexTrafficGenRFC(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ self.sut._traffic_runner = mock.Mock(return_value=0)
+ client_started = multiprocessing.Value('i', 1)
+ result = self.sut.run_traffic(mock_traffic_profile, client_started)
+ self.sut._traffic_process.terminate()
+ self.assertIsNotNone(result)
+
+ def test_scale(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ flavor = ""
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertRaises(NotImplementedError,
+ trex_traffic_gen.scale, flavor)
+
+ def test_terminate(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ self.assertEqual(None, trex_traffic_gen.terminate())
+
+ def test__connect_client(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ trex_traffic_gen = TrexTrafficGenRFC(vnfd)
+ client = mock.Mock(autospec=STLClient)
+ client.connect = mock.Mock(return_value=0)
+ self.assertIsNotNone(trex_traffic_gen._connect_client(client))
diff --git a/tests/unit/network_services/vnf_generic/vnf/test_tg_trex.py b/tests/unit/network_services/vnf_generic/vnf/test_tg_trex.py
new file mode 100644
index 000000000..eb0dbf628
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/test_tg_trex.py
@@ -0,0 +1,368 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+import multiprocessing
+from multiprocessing import Queue
+
+
+STL_MOCKS = {
+ 'stl': mock.MagicMock(),
+ 'stl.trex_stl_lib': mock.MagicMock(),
+ 'stl.trex_stl_lib.base64': mock.MagicMock(),
+ 'stl.trex_stl_lib.binascii': mock.MagicMock(),
+ 'stl.trex_stl_lib.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.copy': mock.MagicMock(),
+ 'stl.trex_stl_lib.datetime': mock.MagicMock(),
+ 'stl.trex_stl_lib.functools': mock.MagicMock(),
+ 'stl.trex_stl_lib.imp': mock.MagicMock(),
+ 'stl.trex_stl_lib.inspect': mock.MagicMock(),
+ 'stl.trex_stl_lib.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.linecache': mock.MagicMock(),
+ 'stl.trex_stl_lib.math': mock.MagicMock(),
+ 'stl.trex_stl_lib.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.platform': mock.MagicMock(),
+ 'stl.trex_stl_lib.pprint': mock.MagicMock(),
+ 'stl.trex_stl_lib.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.socket': mock.MagicMock(),
+ 'stl.trex_stl_lib.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.struct': mock.MagicMock(),
+ 'stl.trex_stl_lib.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.threading': mock.MagicMock(),
+ 'stl.trex_stl_lib.time': mock.MagicMock(),
+ 'stl.trex_stl_lib.traceback': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_async_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_exceptions': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_ext': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_jsonrpc_client': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_interface': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_packet_builder_scapy': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_port': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_stats': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_streams': mock.MagicMock(),
+ 'stl.trex_stl_lib.trex_stl_types': mock.MagicMock(),
+ 'stl.trex_stl_lib.types': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.argparse': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.collections': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.common': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.json': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.os': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.parsing_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.pwd': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.random': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.re': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.string': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.sys': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_opts': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.text_tables': mock.MagicMock(),
+ 'stl.trex_stl_lib.utils.texttable': mock.MagicMock(),
+ 'stl.trex_stl_lib.warnings': mock.MagicMock(),
+ 'stl.trex_stl_lib.yaml': mock.MagicMock(),
+ 'stl.trex_stl_lib.zlib': mock.MagicMock(),
+ 'stl.trex_stl_lib.zmq': mock.MagicMock(),
+}
+
+STLClient = mock.MagicMock()
+stl_patch = mock.patch.dict("sys.modules", STL_MOCKS)
+stl_patch.start()
+
+if stl_patch:
+ from yardstick.network_services.vnf_generic.vnf.tg_trex import \
+ TrexTrafficGen
+ from yardstick.network_services.traffic_profile.base import TrafficProfile
+
+
+class TestTrexTrafficGen(unittest.TestCase):
+ VNFD = {'vnfd:vnfd-catalog':
+ {'vnfd':
+ [{'short-name': 'VpeVnf',
+ 'vdu':
+ [{'routing_table':
+ [{'network': '152.16.100.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'if': 'xe0'},
+ {'network': '152.16.40.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'description': 'VPE approximation using DPDK',
+ 'name': 'vpevnf-baremetal',
+ 'nd_route_tbl':
+ [{'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'id': 'vpevnf-baremetal',
+ 'external-interface':
+ [{'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:04',
+ 'vpci': '0000:05:00.0',
+ 'local_ip': '152.16.100.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '0',
+ 'bandwidth': '10 Gbps',
+ 'driver': "i40e",
+ 'dst_ip': '152.16.100.20',
+ 'local_iface_name': 'xe0',
+ 'local_mac': '00:00:00:00:00:02'},
+ 'vnfd-connection-point-ref': 'xe0',
+ 'name': 'xe0'},
+ {'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:03',
+ 'vpci': '0000:05:00.1',
+ 'local_ip': '152.16.40.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'driver': "i40e",
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '1',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.40.20',
+ 'local_iface_name': 'xe1',
+ 'local_mac': '00:00:00:00:00:01'},
+ 'vnfd-connection-point-ref': 'xe1',
+ 'name': 'xe1'}]}],
+ 'description': 'Vpe approximation using DPDK',
+ 'mgmt-interface':
+ {'vdu-id': 'vpevnf-baremetal',
+ 'host': '1.1.1.1',
+ 'password': 'r00t',
+ 'user': 'root',
+ 'ip': '1.1.1.1'},
+ 'benchmark':
+ {'kpi': ['packets_in', 'packets_fwd', 'packets_dropped']},
+ 'connection-point': [{'type': 'VPORT', 'name': 'xe0'},
+ {'type': 'VPORT', 'name': 'xe1'}],
+ 'id': 'VpeApproxVnf', 'name': 'VPEVnfSsh'}]}}
+
+ TRAFFIC_PROFILE = {
+ "schema": "isb:traffic_profile:0.1",
+ "name": "fixed",
+ "description": "Fixed traffic profile to run UDP traffic",
+ "traffic_profile": {
+ "traffic_type": "FixedTraffic",
+ "frame_rate": 100, # pps
+ "flow_number": 10,
+ "frame_size": 64}}
+
+ def test___init__(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertIsNotNone(trex_traffic_gen._terminated)
+
+ def test_collect_kpi(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ trex_traffic_gen._queue.put({})
+ restult = trex_traffic_gen.collect_kpi()
+ self.assertEqual({}, restult)
+
+ def test_listen_traffic(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(None, trex_traffic_gen.listen_traffic({}))
+
+ def test_instantiate(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(0, trex_traffic_gen.instantiate({}, {}))
+
+ def test_instantiate_error(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(1, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertRaises(RuntimeError,
+ trex_traffic_gen.instantiate, {}, {})
+
+ def test__start_server(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(None, trex_traffic_gen._start_server())
+
+ def test__traffic_runner(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.execute.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = TrexTrafficGen(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ q = Queue()
+ client_started = multiprocessing.Value('i', 1)
+ self.sut._vpci_ascending = ["0000:05:00.0", "0000:05:00.1"]
+ self.sut._connect_client = mock.Mock(autospec=STLClient)
+ self.sut._connect_client.get_stats = mock.Mock(return_value="0")
+ self.sut._traffic_runner(mock_traffic_profile, q, client_started,
+ self.sut._terminated)
+
+ def test__generate_trex_cfg(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(None, trex_traffic_gen._generate_trex_cfg(vnfd))
+
+ def test__split_mac_address_into_list(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ result = ['0x00', '0x00', '0x00', '0x00', '0x00', '0x01']
+ self.assertEqual(
+ result, trex_traffic_gen._split_mac_address_into_list(
+ "00:00:00:00:00:01"))
+
+ def test_run_traffic(self):
+ mock_traffic_profile = mock.Mock(autospec=TrafficProfile)
+ mock_traffic_profile.get_traffic_definition.return_value = "64"
+ mock_traffic_profile.params = self.TRAFFIC_PROFILE
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ self.sut = TrexTrafficGen(vnfd)
+ self.sut.connection = mock.Mock()
+ self.sut.connection.run = mock.Mock()
+ self.sut._traffic_runner = mock.Mock(return_value=0)
+ self.sut.client_started.value = 1
+ result = self.sut.run_traffic(mock_traffic_profile)
+ self.sut._traffic_process.terminate()
+ self.assertIsNotNone(result)
+
+ def test_scale(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(1, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ flavor = ""
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertRaises(NotImplementedError,
+ trex_traffic_gen.scale, flavor)
+
+ def test_setup_vnf_environment(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(1, "", ""))
+ ssh.return_value = ssh_mock
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(
+ None, trex_traffic_gen.setup_vnf_environment(ssh_mock))
+
+ def test_terminate(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ self.assertEqual(None, trex_traffic_gen.terminate())
+
+ def test__connect_client(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ trex_traffic_gen = TrexTrafficGen(vnfd)
+ client = mock.Mock(autospec=STLClient)
+ client.connect = mock.Mock(return_value=0)
+ self.assertIsNotNone(trex_traffic_gen._connect_client(client))
diff --git a/tests/unit/network_services/vnf_generic/vnf/test_vpe_vnf.py b/tests/unit/network_services/vnf_generic/vnf/test_vpe_vnf.py
new file mode 100644
index 000000000..36b8c2a22
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/test_vpe_vnf.py
@@ -0,0 +1,347 @@
+#!/usr/bin/env python
+
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+#
+
+from __future__ import absolute_import
+import unittest
+import mock
+import os
+
+from yardstick.network_services.vnf_generic.vnf.vpe_vnf import VpeApproxVnf
+from yardstick.network_services.vnf_generic.vnf import vpe_vnf
+from yardstick.network_services.nfvi.resource import ResourceProfile
+from yardstick.network_services.vnf_generic.vnf.base import \
+ QueueFileWrapper
+
+
+class TestVpeApproxVnf(unittest.TestCase):
+ VNFD = {'vnfd:vnfd-catalog':
+ {'vnfd':
+ [{'short-name': 'VpeVnf',
+ 'vdu':
+ [{'routing_table':
+ [{'network': '152.16.100.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'if': 'xe0'},
+ {'network': '152.16.40.20',
+ 'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'description': 'VPE approximation using DPDK',
+ 'name': 'vpevnf-baremetal',
+ 'nd_route_tbl':
+ [{'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'id': 'vpevnf-baremetal',
+ 'external-interface':
+ [{'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:04',
+ 'vpci': '0000:05:00.0',
+ 'local_ip': '152.16.100.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '0',
+ 'bandwidth': '10 Gbps',
+ 'driver': "i40e",
+ 'dst_ip': '152.16.100.20',
+ 'local_iface_name': 'xe0',
+ 'local_mac': '00:00:00:00:00:02'},
+ 'vnfd-connection-point-ref': 'xe0',
+ 'name': 'xe0'},
+ {'virtual-interface':
+ {'dst_mac': '00:00:00:00:00:03',
+ 'vpci': '0000:05:00.1',
+ 'local_ip': '152.16.40.19',
+ 'type': 'PCI-PASSTHROUGH',
+ 'driver': "i40e",
+ 'netmask': '255.255.255.0',
+ 'dpdk_port_num': '1',
+ 'bandwidth': '10 Gbps',
+ 'dst_ip': '152.16.40.20',
+ 'local_iface_name': 'xe1',
+ 'local_mac': '00:00:00:00:00:01'},
+ 'vnfd-connection-point-ref': 'xe1',
+ 'name': 'xe1'}]}],
+ 'description': 'Vpe approximation using DPDK',
+ 'mgmt-interface':
+ {'vdu-id': 'vpevnf-baremetal',
+ 'host': '1.2.1.1',
+ 'password': 'r00t',
+ 'user': 'root',
+ 'ip': '1.2.1.1'},
+ 'benchmark':
+ {'kpi': ['packets_in', 'packets_fwd', 'packets_dropped']},
+ 'connection-point': [{'type': 'VPORT', 'name': 'xe0'},
+ {'type': 'VPORT', 'name': 'xe1'}],
+ 'id': 'VpeApproxVnf', 'name': 'VPEVnfSsh'}]}}
+
+ scenario_cfg = {'tc_options': {'rfc2544':
+ {'allowed_drop_rate': '0.8 - 1'}},
+ 'task_id': 'a70bdf4a-8e67-47a3-9dc1-273c14506eb7',
+ 'tc': 'tc_ipv4_1Mflow_64B_packetsize',
+ 'runner': {'object': 'NetworkServiceTestCase',
+ 'interval': 35,
+ 'output_filename': '/tmp/yardstick.out',
+ 'runner_id': 74476, 'duration': 400,
+ 'type': 'Duration'},
+ 'traffic_profile': 'ipv4_throughput_vpe.yaml',
+ 'traffic_options': {'flow': 'ipv4_Packets_vpe.yaml',
+ 'imix': 'imix_voice.yaml'},
+ 'type': 'ISB',
+ 'nodes': {'tg__2': 'trafficgen_2.yardstick',
+ 'tg__1': 'trafficgen_1.yardstick',
+ 'vnf__1': 'vnf.yardstick'},
+ 'topology': 'vpe-tg-topology-baremetal.yaml'}
+
+ context_cfg = {'nodes': {'tg__2':
+ {'member-vnf-index': '3',
+ 'role': 'TrafficGen',
+ 'name': 'trafficgen_2.yardstick',
+ 'vnfd-id-ref': 'tg__2',
+ 'ip': '1.2.1.1',
+ 'interfaces':
+ {'xe0': {'local_iface_name': 'ens513f0',
+ 'vld_id': 'public',
+ 'netmask': '255.255.255.0',
+ 'local_ip': '152.16.40.20',
+ 'dst_mac': '00:00:00:00:00:01',
+ 'local_mac': '00:00:00:00:00:03',
+ 'dst_ip': '152.16.40.19',
+ 'driver': 'ixgbe',
+ 'vpci': '0000:02:00.0',
+ 'dpdk_port_num': 0},
+ 'xe1': {'local_iface_name': 'ens513f1',
+ 'netmask': '255.255.255.0',
+ 'network': '202.16.100.0',
+ 'local_ip': '202.16.100.20',
+ 'local_mac': '00:1e:67:d0:60:5d',
+ 'driver': 'ixgbe',
+ 'vpci': '0000:02:00.1',
+ 'dpdk_port_num': 1}},
+ 'password': 'r00t',
+ 'VNF model': 'l3fwd_vnf.yaml',
+ 'user': 'root'},
+ 'tg__1':
+ {'member-vnf-index': '1',
+ 'role': 'TrafficGen',
+ 'name': 'trafficgen_1.yardstick',
+ 'vnfd-id-ref': 'tg__1',
+ 'ip': '1.2.1.1',
+ 'interfaces':
+ {'xe0': {'local_iface_name': 'ens785f0',
+ 'vld_id': 'private',
+ 'netmask': '255.255.255.0',
+ 'local_ip': '152.16.100.20',
+ 'dst_mac': '00:00:00:00:00:02',
+ 'local_mac': '00:00:00:00:00:04',
+ 'dst_ip': '152.16.100.19',
+ 'driver': 'i40e',
+ 'vpci': '0000:05:00.0',
+ 'dpdk_port_num': 0},
+ 'xe1': {'local_iface_name': 'ens785f1',
+ 'netmask': '255.255.255.0',
+ 'local_ip': '152.16.100.21',
+ 'local_mac': '00:00:00:00:00:01',
+ 'driver': 'i40e',
+ 'vpci': '0000:05:00.1',
+ 'dpdk_port_num': 1}},
+ 'password': 'r00t',
+ 'VNF model': 'tg_rfc2544_tpl.yaml',
+ 'user': 'root'},
+ 'vnf__1':
+ {'name': 'vnf.yardstick',
+ 'vnfd-id-ref': 'vnf__1',
+ 'ip': '1.2.1.1',
+ 'interfaces':
+ {'xe0': {'local_iface_name': 'ens786f0',
+ 'vld_id': 'private',
+ 'netmask': '255.255.255.0',
+ 'local_ip': '152.16.100.19',
+ 'dst_mac': '00:00:00:00:00:04',
+ 'local_mac': '00:00:00:00:00:02',
+ 'dst_ip': '152.16.100.20',
+ 'driver': 'i40e',
+ 'vpci': '0000:05:00.0',
+ 'dpdk_port_num': 0},
+ 'xe1': {'local_iface_name': 'ens786f1',
+ 'vld_id': 'public',
+ 'netmask': '255.255.255.0',
+ 'local_ip': '152.16.40.19',
+ 'dst_mac': '00:00:00:00:00:03',
+ 'local_mac': '00:00:00:00:00:01',
+ 'dst_ip': '152.16.40.20',
+ 'driver': 'i40e',
+ 'vpci': '0000:05:00.1',
+ 'dpdk_port_num': 1}},
+ 'routing_table':
+ [{'netmask': '255.255.255.0',
+ 'gateway': '152.16.100.20',
+ 'network': '152.16.100.20',
+ 'if': 'xe0'},
+ {'netmask': '255.255.255.0',
+ 'gateway': '152.16.40.20',
+ 'network': '152.16.40.20',
+ 'if': 'xe1'}],
+ 'member-vnf-index': '2',
+ 'host': '1.2.1.1',
+ 'role': 'vnf',
+ 'user': 'root',
+ 'nd_route_tbl':
+ [{'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:6414',
+ 'network': '0064:ff9b:0:0:0:0:9810:6414',
+ 'if': 'xe0'},
+ {'netmask': '112',
+ 'gateway': '0064:ff9b:0:0:0:0:9810:2814',
+ 'network': '0064:ff9b:0:0:0:0:9810:2814',
+ 'if': 'xe1'}],
+ 'password': 'r00t',
+ 'VNF model': 'vpe_vnf.yaml'}}}
+
+ def test___init__(self):
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ self.assertIsNone(vpe_approx_vnf._vnf_process)
+
+ def test_collect_kpi(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ vpe_approx_vnf.resource = mock.Mock(autospec=ResourceProfile)
+ vpe_approx_vnf.resource.check_if_sa_running = \
+ mock.Mock(return_value=[0, 1])
+ vpe_approx_vnf.resource.amqp_collect_nfvi_kpi= \
+ mock.Mock(return_value={})
+ result = {'pkt_in_down_stream': 0,
+ 'pkt_in_up_stream': 0,
+ 'collect_stats': {'core': {}},
+ 'pkt_drop_down_stream': 0, 'pkt_drop_up_stream': 0}
+ self.assertEqual(result, vpe_approx_vnf.collect_kpi())
+
+ def test_execute_command(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ cmd = "quit"
+ self.assertEqual("", vpe_approx_vnf.execute_command(cmd))
+
+ def test_get_stats_vpe(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ vpe_approx_vnf.execute_command = \
+ mock.Mock(return_value="Pkts in: 101\r\n\tPkts dropped by AH: 100\r\n\tPkts dropped by other: 100")
+ result = {'pkt_in_down_stream': 202, 'pkt_in_up_stream': 303,
+ 'pkt_drop_down_stream': 400, 'pkt_drop_up_stream': 600}
+ self.assertEqual(result, vpe_approx_vnf.get_stats_vpe())
+
+ def test_run_vpe(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh_mock.run = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ curr_path = os.path.dirname(os.path.abspath(__file__))
+ vpe_vnf = os.path.join(curr_path, "vpe_config")
+ queue_wrapper = \
+ QueueFileWrapper(vpe_approx_vnf.q_in,
+ vpe_approx_vnf.q_out, "pipeline>")
+ self.assertEqual(None,
+ vpe_approx_vnf._run_vpe(queue_wrapper, vpe_vnf))
+
+ def test_instantiate(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ self.scenario_cfg['vnf_options'] = {'vpe': {'cfg': ""}}
+ vpe_approx_vnf._run_vpe = mock.Mock(return_value=0)
+ vpe_approx_vnf._resource_collect_start = mock.Mock(return_value=0)
+ vpe_approx_vnf.q_out.put("pipeline>")
+ vpe_vnf.WAIT_TIME = 3
+ self.assertEqual(0, vpe_approx_vnf.instantiate(self.scenario_cfg,
+ self.context_cfg))
+
+ def test_instantiate_panic(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(1, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ self.scenario_cfg['vnf_options'] = {'vpe': {'cfg': ""}}
+ vpe_approx_vnf._run_vpe = mock.Mock(return_value=0)
+ vpe_vnf.WAIT_TIME = 1
+ self.assertRaises(RuntimeError, vpe_approx_vnf.instantiate,
+ self.scenario_cfg, self.context_cfg)
+
+ def test_scale(self):
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ flavor = ""
+ self.assertRaises(NotImplementedError, vpe_approx_vnf.scale, flavor)
+
+ def test_setup_vnf_environment(self):
+ with mock.patch("yardstick.ssh.SSH") as ssh:
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ ssh_mock = mock.Mock(autospec=ssh.SSH)
+ ssh_mock.execute = \
+ mock.Mock(return_value=(0, "", ""))
+ ssh.return_value = ssh_mock
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ self.assertEqual(None,
+ vpe_approx_vnf.setup_vnf_environment(ssh_mock))
+
+ def test_terminate(self):
+ vnfd = self.VNFD['vnfd:vnfd-catalog']['vnfd'][0]
+ vpe_approx_vnf = VpeApproxVnf(vnfd)
+ self.assertEqual(None, vpe_approx_vnf.terminate())
+
+if __name__ == '__main__':
+ unittest.main()
diff --git a/tests/unit/network_services/vnf_generic/vnf/vpe_config/action_bulk_512.txt b/tests/unit/network_services/vnf_generic/vnf/vpe_config/action_bulk_512.txt
new file mode 100644
index 000000000..21731cd45
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/vpe_config/action_bulk_512.txt
@@ -0,0 +1,512 @@
+flow 0 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 1 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 2 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 3 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 4 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 5 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 6 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 7 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 8 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 9 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 10 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 11 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 12 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 13 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 14 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 15 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 16 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 17 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 18 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 19 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 20 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 21 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 22 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 23 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 24 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 25 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 26 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 27 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 28 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 29 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 30 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 31 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 32 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 33 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 34 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 35 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 36 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 37 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 38 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 39 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 40 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 41 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 42 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 43 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 44 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 45 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 46 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 47 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 48 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 49 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 50 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 51 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 52 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 53 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 54 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 55 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 56 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 57 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 58 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 59 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 60 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 61 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 62 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 63 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 64 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 65 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 66 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 67 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 68 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 69 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 70 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 71 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 72 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 73 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 74 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 75 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 76 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 77 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 78 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 79 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 80 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 81 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 82 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 83 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 84 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 85 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 86 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 87 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 88 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 89 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 90 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 91 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 92 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 93 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 94 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 95 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 96 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 97 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 98 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 99 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 100 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 101 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 102 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 103 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 104 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 105 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 106 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 107 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 108 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 109 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 110 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 111 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 112 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 113 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 114 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 115 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 116 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 117 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 118 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 119 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 120 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 121 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 122 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 123 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 124 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 125 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 126 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 127 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 128 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 129 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 130 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 131 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 132 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 133 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 134 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 135 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 136 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 137 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 138 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 139 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 140 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 141 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 142 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 143 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 144 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 145 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 146 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 147 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 148 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 149 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 150 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 151 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 152 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 153 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 154 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 155 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 156 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 157 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 158 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 159 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 160 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 161 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 162 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 163 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 164 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 165 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 166 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 167 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 168 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 169 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 170 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 171 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 172 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 173 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 174 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 175 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 176 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 177 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 178 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 179 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 180 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 181 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 182 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 183 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 184 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 185 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 186 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 187 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 188 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 189 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 190 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 191 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 192 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 193 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 194 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 195 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 196 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 197 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 198 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 199 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 200 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 201 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 202 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 203 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 204 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 205 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 206 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 207 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 208 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 209 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 210 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 211 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 212 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 213 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 214 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 215 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 216 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 217 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 218 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 219 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 220 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 221 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 222 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 223 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 224 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 225 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 226 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 227 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 228 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 229 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 230 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 231 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 232 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 233 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 234 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 235 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 236 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 237 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 238 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 239 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 240 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 241 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 242 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 243 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 244 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 245 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 246 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 247 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 248 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 249 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 250 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 251 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 252 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 253 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 254 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 255 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 256 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 257 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 258 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 259 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 260 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 261 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 262 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 263 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 264 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 265 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 266 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 267 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 268 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 269 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 270 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 271 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 272 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 273 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 274 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 275 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 276 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 277 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 278 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 279 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 280 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 281 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 282 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 283 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 284 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 285 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 286 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 287 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 288 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 289 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 290 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 291 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 292 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 293 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 294 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 295 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 296 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 297 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 298 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 299 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 300 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 301 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 302 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 303 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 304 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 305 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 306 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 307 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 308 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 309 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 310 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 311 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 312 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 313 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 314 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 315 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 316 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 317 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 318 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 319 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 320 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 321 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 322 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 323 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 324 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 325 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 326 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 327 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 328 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 329 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 330 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 331 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 332 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 333 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 334 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 335 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 336 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 337 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 338 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 339 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 340 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 341 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 342 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 343 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 344 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 345 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 346 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 347 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 348 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 349 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 350 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 351 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 352 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 353 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 354 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 355 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 356 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 357 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 358 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 359 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 360 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 361 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 362 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 363 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 364 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 365 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 366 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 367 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 368 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 369 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 370 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 371 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 372 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 373 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 374 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 375 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 376 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 377 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 378 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 379 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 380 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 381 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 382 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 383 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 384 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 385 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 386 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 387 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 388 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 389 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 390 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 391 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 392 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 393 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 394 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 395 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 396 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 397 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 398 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 399 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 400 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 401 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 402 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 403 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 404 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 405 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 406 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 407 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 408 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 409 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 410 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 411 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 412 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 413 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 414 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 415 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 416 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 417 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 418 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 419 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 420 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 421 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 422 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 423 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 424 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 425 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 426 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 427 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 428 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 429 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 430 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 431 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 432 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 433 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 434 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 435 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 436 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 437 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 438 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 439 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 440 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 441 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 442 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 443 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 444 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 445 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 446 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 447 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 448 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 449 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 450 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 451 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 452 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 453 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 454 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 455 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 456 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 457 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 458 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 459 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 460 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 461 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 462 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 463 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 464 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 465 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 466 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 467 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 468 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 469 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 470 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 471 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 472 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 473 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 474 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 475 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 476 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 477 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 478 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 479 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 480 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 481 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 482 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 483 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 484 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 485 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 486 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 487 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 488 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 489 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 490 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 491 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 492 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 493 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 494 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 495 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 496 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 497 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 498 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 499 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 500 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 501 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 502 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 503 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 504 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 505 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 506 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 507 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 508 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 509 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 510 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
+flow 511 meter 0 trtcm 1250000000 1250000000 1000000 1000000 policer 0 g G y Y r R meter 1 trtcm 1250000000 1250000000 1000000 1000000 policer 1 g G y Y r R meter 2 trtcm 1250000000 1250000000 1000000 1000000 policer 2 g G y Y r R meter 3 trtcm 1250000000 1250000000 1000000 1000000 policer 3 g G y Y r R port 0
diff --git a/tests/unit/network_services/vnf_generic/vnf/vpe_config/full_tm_profile_10G.cfg b/tests/unit/network_services/vnf_generic/vnf/vpe_config/full_tm_profile_10G.cfg
new file mode 100755
index 000000000..502655fd0
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/vpe_config/full_tm_profile_10G.cfg
@@ -0,0 +1,105 @@
+; BSD LICENSE
+;
+; Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
+; All rights reserved.
+;
+; Redistribution and use in source and binary forms, with or without
+; modification, are permitted provided that the following conditions
+; are met:
+;
+; * Redistributions of source code must retain the above copyright
+; notice, this list of conditions and the following disclaimer.
+; * Redistributions in binary form must reproduce the above copyright
+; notice, this list of conditions and the following disclaimer in
+; the documentation and/or other materials provided with the
+; distribution.
+; * Neither the name of Intel Corporation nor the names of its
+; contributors may be used to endorse or promote products derived
+; from this software without specific prior written permission.
+;
+; THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+; "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+; LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
+; A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
+; OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
+; SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
+; LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
+; DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
+; THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
+; (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
+; OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+
+; This file enables the following hierarchical scheduler configuration for each
+; 10GbE output port:
+; * Single subport (subport 0):
+; - Subport rate set to 100% of port rate
+; - Each of the 4 traffic classes has rate set to 100% of port rate
+; * 4K pipes per subport 0 (pipes 0 .. 4095) with identical configuration:
+; - Pipe rate set to 1/4K of port rate
+; - Each of the 4 traffic classes has rate set to 100% of pipe rate
+; - Within each traffic class, the byte-level WRR weights for the 4 queues
+; are set to 1:1:1:1
+;
+; For more details, please refer to chapter "Quality of Service (QoS) Framework"
+; of Intel Data Plane Development Kit (Intel DPDK) Programmer's Guide.
+
+; Port configuration
+[port]
+frame overhead = 24 ; frame overhead = Preamble (7) + SFD (1) + FCS (4) + IFG (12)
+mtu = 1522; mtu = Q-in-Q MTU (FCS not included)
+number of subports per port = 1
+number of pipes per subport = 4096
+queue sizes = 64 64 64 64
+
+; Subport configuration
+[subport 0]
+tb rate = 1250000000 ; Bytes per second
+tb size = 1000000 ; Bytes
+
+tc 0 rate = 1250000000 ; Bytes per second
+tc 1 rate = 1250000000 ; Bytes per second
+tc 2 rate = 1250000000 ; Bytes per second
+tc 3 rate = 1250000000 ; Bytes per second
+tc period = 10 ; Milliseconds
+
+pipe 0-4095 = 0 ; These pipes are configured with pipe profile 0
+
+; Pipe configuration
+[pipe profile 0]
+tb rate = 1250000000 ; Bytes per second
+tb size = 1000000 ; Bytes
+
+tc 0 rate = 1250000000 ; Bytes per second
+tc 1 rate = 1250000000 ; Bytes per second
+tc 2 rate = 1250000000 ; Bytes per second
+tc 3 rate = 1250000000 ; Bytes per second
+tc period = 40 ; Milliseconds
+
+tc 3 oversubscription weight = 1
+
+tc 0 wrr weights = 1 1 1 1
+tc 1 wrr weights = 1 1 1 1
+tc 2 wrr weights = 1 1 1 1
+tc 3 wrr weights = 1 1 1 1
+
+; RED params per traffic class and color (Green / Yellow / Red)
+[red]
+tc 0 wred min = 48 40 32
+tc 0 wred max = 64 64 64
+tc 0 wred inv prob = 10 10 10
+tc 0 wred weight = 9 9 9
+
+tc 1 wred min = 48 40 32
+tc 1 wred max = 64 64 64
+tc 1 wred inv prob = 10 10 10
+tc 1 wred weight = 9 9 9
+
+tc 2 wred min = 48 40 32
+tc 2 wred max = 64 64 64
+tc 2 wred inv prob = 10 10 10
+tc 2 wred weight = 9 9 9
+
+tc 3 wred min = 48 40 32
+tc 3 wred max = 64 64 64
+tc 3 wred inv prob = 10 10 10
+tc 3 wred weight = 9 9 9
diff --git a/tests/unit/network_services/vnf_generic/vnf/vpe_config/fw_bulk_inst0_256.txt b/tests/unit/network_services/vnf_generic/vnf/vpe_config/fw_bulk_inst0_256.txt
new file mode 100644
index 000000000..307150789
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/vpe_config/fw_bulk_inst0_256.txt
@@ -0,0 +1,256 @@
+priority 1 ipv4 152.16.0.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.1.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.2.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.3.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.4.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.5.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.6.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.7.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.8.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.9.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.10.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.11.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.12.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.13.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.14.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.15.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.16.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.17.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.18.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.19.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.20.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.21.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.22.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.23.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.24.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.25.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.26.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.27.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.28.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.29.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.30.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.31.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.32.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.33.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.34.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.35.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.36.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.37.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.38.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.39.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.40.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.41.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.42.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.43.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.44.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.45.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.46.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.47.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.48.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.49.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.50.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.51.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.52.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.53.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.54.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.55.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.56.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.57.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.58.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.59.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.60.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.61.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.62.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.63.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.64.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.65.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.66.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.67.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.68.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.69.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.70.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.71.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.72.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.73.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.74.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.75.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.76.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.77.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.78.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.79.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.80.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.81.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.82.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.83.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.84.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.85.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.86.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.87.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.88.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.89.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.90.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.91.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.92.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.93.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.94.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.95.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.96.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.97.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.98.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.99.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.100.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.101.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.102.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.103.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.104.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.105.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.106.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.107.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.108.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.109.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.110.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.111.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.112.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.113.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.114.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.115.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.116.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.117.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.118.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.119.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.120.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.121.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.122.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.123.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.124.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.125.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.126.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.127.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.128.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.129.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.130.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.131.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.132.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.133.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.134.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.135.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.136.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.137.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.138.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.139.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.140.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.141.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.142.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.143.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.144.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.145.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.146.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.147.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.148.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.149.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.150.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.151.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.152.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.153.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.154.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.155.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.156.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.157.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.158.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.159.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.160.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.161.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.162.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.163.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.164.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.165.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.166.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.167.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.168.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.169.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.170.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.171.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.172.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.173.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.174.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.175.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.176.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.177.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.178.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.179.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.180.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.181.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.182.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.183.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.184.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.185.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.186.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.187.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.188.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.189.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.190.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.191.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.192.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.193.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.194.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.195.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.196.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.197.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.198.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.199.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.200.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.201.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.202.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.203.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.204.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.205.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.206.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.207.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.208.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.209.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.210.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.211.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.212.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.213.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.214.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.215.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.216.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.217.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.218.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.219.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.220.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.221.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.222.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.223.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.224.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.225.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.226.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.227.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.228.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.229.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.230.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.231.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.232.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.233.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.234.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.235.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.236.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.237.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.238.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.239.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.240.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.241.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.242.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.243.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.244.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.245.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.246.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.247.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.248.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.249.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.250.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.251.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.252.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.253.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.254.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
+priority 1 ipv4 152.16.255.0 24 0.0.0.0 0 0 65535 0 65535 6 0xFF port 0
diff --git a/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_config b/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_config
new file mode 100644
index 000000000..17ebc6a76
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_config
@@ -0,0 +1,101 @@
+[EAL]
+log_level = 0
+
+[PIPELINE0]
+type = MASTER
+core = s{socket}c0
+
+[MEMPOOL0]
+pool_size = 256K
+
+[MEMPOOL1]
+pool_size = 2M
+
+[RXQ1.0]
+mempool = MEMPOOL1
+
+;;;;;;;;;;Begin of upstream 0;;;;;;;;;;;;;;;;;;
+[PIPELINE1]
+type = FIREWALL
+core = s{socket}c1
+pktq_in = RXQ0.0
+pktq_out = SWQ0 SINK0
+n_rules = 4096
+pkt_type = qinq_ipv4
+
+[PIPELINE2]
+type = FLOW_CLASSIFICATION
+core = s{socket}c1
+pktq_in = SWQ0
+pktq_out = SWQ1 SINK1
+n_flows = 65536
+key_size = 8; dma_size
+key_offset = 268; dma_dst_offset
+key_mask = 00000FFF00000FFF; qinq
+flowid_offset = 172; mbuf (128) + 64
+
+[PIPELINE3]
+type = FLOW_ACTIONS
+core = s{socket}c1h
+pktq_in = SWQ1
+pktq_out = SWQ2
+n_flows = 65536
+n_meters_per_flow = 1;dscp is not considered for per user metering
+flow_id_offset = 172; mbuf (128) + 64
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+[PIPELINE4]
+type = FLOW_ACTIONS
+core = s{socket}c1h
+pktq_in = SWQ2
+pktq_out = SWQ3
+n_flows = 65536
+n_meters_per_flow = 4; Use dscp to classify into 1 out of 4 TC
+flow_id_offset = 172; mbuf (128) + 64
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+[PIPELINE5]
+type = ROUTING
+core = s{socket}c1
+pktq_in = SWQ3
+pktq_out = TXQ1.0 SINK2
+encap = ethernet_mpls
+mpls_color_mark = yes
+ip_hdr_offset = 278 ; should not needed, but who knows?
+color_offset = 176
+
+;;;;;;;;;;Begin of downstream 0;;;;;;;;;;;;;;;;;;
+[PIPELINE6]
+type = ROUTING
+core = s{socket}c2
+pktq_in = RXQ1.0
+pktq_out = SWQ4 SINK3
+encap = ethernet_qinq
+qinq_sched = yes
+ip_hdr_offset = 270; mbuf (128) + headroom (128) + ethernet header (14) = 270
+
+
+[PIPELINE7]
+type = PASS-THROUGH
+core = s{socket}c2h
+pktq_in = SWQ4
+pktq_out = SWQ5
+
+[PIPELINE8]
+type = PASS-THROUGH
+core = s{socket}c2h
+pktq_in = SWQ5 TM0
+pktq_out = TM0 SWQ6
+
+[PIPELINE9]
+type = PASS-THROUGH
+core = s{socket}c2
+pktq_in = SWQ6
+pktq_out = TXQ0.0
+
+[TM0]
+burst_read = 24;dequeue should be slightly slower then enqueue to create buffer
+burst_write = 32
+cfg = /tmp/full_tm_profile_10G.cfg
diff --git a/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_script b/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_script
new file mode 100644
index 000000000..740eb6586
--- /dev/null
+++ b/tests/unit/network_services/vnf_generic/vnf/vpe_config/vpe_script
@@ -0,0 +1,384 @@
+#=================================================================
+#Pipeline 1 : 256 Firewall Rules for 1 port with 0.0.X.0/24 for destination IP
+#=================================================================
+p 1 firewall add bulk /tmp/fw_bulk_inst0_256.txt
+p 1 firewall add default 1
+
+#=================================================================
+#Pipeline 2 : 512 flow classfication Rules for 1 port using QinQ as input. Flow id = SVLAN * 512 + CVLAN
+#=================================================================
+p 2 flow add qinq 128 512 port 0 id 1
+p 2 flow add default 1
+
+#=================================================================
+#Pipeline 3 : 512 metering Rules for 1 port
+#=================================================================
+p 3 action flow bulk /tmp/action_bulk_512.txt
+p 3 flows 512 ports 1
+
+#=================================================================
+#Pipeline 4 : 512 metering Rules and 4 traffic classes for 1 port
+#=================================================================
+p 4 action flow bulk /tmp/action_bulk_512.txt
+p 4 flows 512 ports 1
+p 4 action dscp 0 class 0 color G
+p 4 action dscp 1 class 1 color Y
+p 4 action dscp 2 class 2 color R
+p 4 action dscp 3 class 3 color G
+p 4 action dscp 4 class 0 color Y
+p 4 action dscp 5 class 1 color R
+p 4 action dscp 6 class 2 color G
+p 4 action dscp 7 class 3 color Y
+p 4 action dscp 8 class 0 color R
+p 4 action dscp 9 class 1 color G
+p 4 action dscp 10 class 2 color Y
+p 4 action dscp 11 class 3 color R
+p 4 action dscp 12 class 0 color G
+p 4 action dscp 13 class 1 color Y
+p 4 action dscp 14 class 2 color R
+p 4 action dscp 15 class 3 color G
+p 4 action dscp 16 class 0 color Y
+p 4 action dscp 17 class 1 color R
+p 4 action dscp 18 class 2 color G
+p 4 action dscp 19 class 3 color Y
+p 4 action dscp 20 class 0 color R
+p 4 action dscp 21 class 1 color G
+p 4 action dscp 22 class 2 color Y
+p 4 action dscp 23 class 3 color R
+p 4 action dscp 24 class 0 color G
+p 4 action dscp 25 class 1 color Y
+p 4 action dscp 26 class 2 color R
+p 4 action dscp 27 class 3 color G
+p 4 action dscp 28 class 0 color Y
+p 4 action dscp 29 class 1 color R
+p 4 action dscp 30 class 2 color G
+p 4 action dscp 31 class 3 color Y
+p 4 action dscp 32 class 0 color R
+p 4 action dscp 33 class 1 color G
+p 4 action dscp 34 class 2 color Y
+p 4 action dscp 35 class 3 color R
+p 4 action dscp 36 class 0 color G
+p 4 action dscp 37 class 1 color Y
+p 4 action dscp 38 class 2 color R
+p 4 action dscp 39 class 3 color G
+p 4 action dscp 40 class 0 color Y
+p 4 action dscp 41 class 1 color R
+p 4 action dscp 42 class 2 color G
+p 4 action dscp 43 class 3 color Y
+p 4 action dscp 44 class 0 color R
+p 4 action dscp 45 class 1 color G
+p 4 action dscp 46 class 2 color Y
+p 4 action dscp 47 class 3 color R
+p 4 action dscp 48 class 0 color G
+p 4 action dscp 49 class 1 color Y
+p 4 action dscp 50 class 2 color R
+p 4 action dscp 51 class 3 color G
+p 4 action dscp 52 class 0 color Y
+p 4 action dscp 53 class 1 color R
+p 4 action dscp 54 class 2 color G
+p 4 action dscp 55 class 3 color Y
+p 4 action dscp 56 class 0 color R
+p 4 action dscp 57 class 1 color G
+p 4 action dscp 58 class 2 color Y
+p 4 action dscp 59 class 3 color R
+p 4 action dscp 60 class 0 color G
+p 4 action dscp 61 class 1 color Y
+p 4 action dscp 62 class 2 color R
+p 4 action dscp 63 class 3 color G
+#=================================================================
+#Pipeline 5 : 32 Upstream Routing Rules for 1 ports with dst_ip : 0.0.0.0 to 0.0.255.255
+#=================================================================
+p 5 route add 152.40.0.0 21 port 0 ether {port1_dst_mac} mpls 0:0
+p 5 route add 152.40.8.0 21 port 0 ether {port1_dst_mac} mpls 0:1
+p 5 route add 152.40.16.0 21 port 0 ether {port1_dst_mac} mpls 0:2
+p 5 route add 152.40.24.0 21 port 0 ether {port1_dst_mac} mpls 0:3
+p 5 route add 152.40.32.0 21 port 0 ether {port1_dst_mac} mpls 0:4
+p 5 route add 152.40.40.0 21 port 0 ether {port1_dst_mac} mpls 0:5
+p 5 route add 152.40.48.0 21 port 0 ether {port1_dst_mac} mpls 0:6
+p 5 route add 152.40.56.0 21 port 0 ether {port1_dst_mac} mpls 0:7
+p 5 route add 152.40.64.0 21 port 0 ether {port1_dst_mac} mpls 0:8
+p 5 route add 152.40.72.0 21 port 0 ether {port1_dst_mac} mpls 0:9
+p 5 route add 152.40.80.0 21 port 0 ether {port1_dst_mac} mpls 0:10
+p 5 route add 152.40.88.0 21 port 0 ether {port1_dst_mac} mpls 0:11
+p 5 route add 152.40.96.0 21 port 0 ether {port1_dst_mac} mpls 0:12
+p 5 route add 152.40.104.0 21 port 0 ether {port1_dst_mac} mpls 0:13
+p 5 route add 152.40.112.0 21 port 0 ether {port1_dst_mac} mpls 0:14
+p 5 route add 152.40.120.0 21 port 0 ether {port1_dst_mac} mpls 0:15
+p 5 route add 152.40.128.0 21 port 0 ether {port1_dst_mac} mpls 0:16
+p 5 route add 152.40.136.0 21 port 0 ether {port1_dst_mac} mpls 0:17
+p 5 route add 152.40.144.0 21 port 0 ether {port1_dst_mac} mpls 0:18
+p 5 route add 152.40.152.0 21 port 0 ether {port1_dst_mac} mpls 0:19
+p 5 route add 152.40.160.0 21 port 0 ether {port1_dst_mac} mpls 0:20
+p 5 route add 152.40.168.0 21 port 0 ether {port1_dst_mac} mpls 0:21
+p 5 route add 152.40.176.0 21 port 0 ether {port1_dst_mac} mpls 0:22
+p 5 route add 152.40.184.0 21 port 0 ether {port1_dst_mac} mpls 0:23
+p 5 route add 152.40.192.0 21 port 0 ether {port1_dst_mac} mpls 0:24
+p 5 route add 152.40.200.0 21 port 0 ether {port1_dst_mac} mpls 0:25
+p 5 route add 152.40.208.0 21 port 0 ether {port1_dst_mac} mpls 0:26
+p 5 route add 152.40.216.0 21 port 0 ether {port1_dst_mac} mpls 0:27
+p 5 route add 152.40.224.0 21 port 0 ether {port1_dst_mac} mpls 0:28
+p 5 route add 152.40.232.0 21 port 0 ether {port1_dst_mac} mpls 0:29
+p 5 route add 152.40.240.0 21 port 0 ether {port1_dst_mac} mpls 0:30
+p 5 route add 152.40.248.0 21 port 0 ether {port1_dst_mac} mpls 0:31
+p 5 route add default 1
+
+#=================================================================
+#Pipeline 6 : 256 Downstream Routing Rules for 1 ports with dst_ip : 0.0.0.0 to 0.0.255.255
+#=================================================================
+p 6 route add 152.16.0.0 24 port 0 ether {port0_dst_mac} qinq 0 0
+p 6 route add 152.16.1.0 24 port 0 ether {port0_dst_mac} qinq 0 1
+p 6 route add 152.16.2.0 24 port 0 ether {port0_dst_mac} qinq 0 2
+p 6 route add 152.16.3.0 24 port 0 ether {port0_dst_mac} qinq 0 3
+p 6 route add 152.16.4.0 24 port 0 ether {port0_dst_mac} qinq 0 4
+p 6 route add 152.16.5.0 24 port 0 ether {port0_dst_mac} qinq 0 5
+p 6 route add 152.16.6.0 24 port 0 ether {port0_dst_mac} qinq 0 6
+p 6 route add 152.16.7.0 24 port 0 ether {port0_dst_mac} qinq 0 7
+p 6 route add 152.16.8.0 24 port 0 ether {port0_dst_mac} qinq 0 8
+p 6 route add 152.16.9.0 24 port 0 ether {port0_dst_mac} qinq 0 9
+p 6 route add 152.16.10.0 24 port 0 ether {port0_dst_mac} qinq 0 10
+p 6 route add 152.16.11.0 24 port 0 ether {port0_dst_mac} qinq 0 11
+p 6 route add 152.16.12.0 24 port 0 ether {port0_dst_mac} qinq 0 12
+p 6 route add 152.16.13.0 24 port 0 ether {port0_dst_mac} qinq 0 13
+p 6 route add 152.16.14.0 24 port 0 ether {port0_dst_mac} qinq 0 14
+p 6 route add 152.16.15.0 24 port 0 ether {port0_dst_mac} qinq 0 15
+p 6 route add 152.16.16.0 24 port 0 ether {port0_dst_mac} qinq 0 16
+p 6 route add 152.16.17.0 24 port 0 ether {port0_dst_mac} qinq 0 17
+p 6 route add 152.16.18.0 24 port 0 ether {port0_dst_mac} qinq 0 18
+p 6 route add 152.16.19.0 24 port 0 ether {port0_dst_mac} qinq 0 19
+p 6 route add 152.16.20.0 24 port 0 ether {port0_dst_mac} qinq 0 20
+p 6 route add 152.16.21.0 24 port 0 ether {port0_dst_mac} qinq 0 21
+p 6 route add 152.16.22.0 24 port 0 ether {port0_dst_mac} qinq 0 22
+p 6 route add 152.16.23.0 24 port 0 ether {port0_dst_mac} qinq 0 23
+p 6 route add 152.16.24.0 24 port 0 ether {port0_dst_mac} qinq 0 24
+p 6 route add 152.16.25.0 24 port 0 ether {port0_dst_mac} qinq 0 25
+p 6 route add 152.16.26.0 24 port 0 ether {port0_dst_mac} qinq 0 26
+p 6 route add 152.16.27.0 24 port 0 ether {port0_dst_mac} qinq 0 27
+p 6 route add 152.16.28.0 24 port 0 ether {port0_dst_mac} qinq 0 28
+p 6 route add 152.16.29.0 24 port 0 ether {port0_dst_mac} qinq 0 29
+p 6 route add 152.16.30.0 24 port 0 ether {port0_dst_mac} qinq 0 30
+p 6 route add 152.16.31.0 24 port 0 ether {port0_dst_mac} qinq 0 31
+p 6 route add 152.16.32.0 24 port 0 ether {port0_dst_mac} qinq 0 32
+p 6 route add 152.16.33.0 24 port 0 ether {port0_dst_mac} qinq 0 33
+p 6 route add 152.16.34.0 24 port 0 ether {port0_dst_mac} qinq 0 34
+p 6 route add 152.16.35.0 24 port 0 ether {port0_dst_mac} qinq 0 35
+p 6 route add 152.16.36.0 24 port 0 ether {port0_dst_mac} qinq 0 36
+p 6 route add 152.16.37.0 24 port 0 ether {port0_dst_mac} qinq 0 37
+p 6 route add 152.16.38.0 24 port 0 ether {port0_dst_mac} qinq 0 38
+p 6 route add 152.16.39.0 24 port 0 ether {port0_dst_mac} qinq 0 39
+p 6 route add 152.16.40.0 24 port 0 ether {port0_dst_mac} qinq 0 40
+p 6 route add 152.16.41.0 24 port 0 ether {port0_dst_mac} qinq 0 41
+p 6 route add 152.16.42.0 24 port 0 ether {port0_dst_mac} qinq 0 42
+p 6 route add 152.16.43.0 24 port 0 ether {port0_dst_mac} qinq 0 43
+p 6 route add 152.16.44.0 24 port 0 ether {port0_dst_mac} qinq 0 44
+p 6 route add 152.16.45.0 24 port 0 ether {port0_dst_mac} qinq 0 45
+p 6 route add 152.16.46.0 24 port 0 ether {port0_dst_mac} qinq 0 46
+p 6 route add 152.16.47.0 24 port 0 ether {port0_dst_mac} qinq 0 47
+p 6 route add 152.16.48.0 24 port 0 ether {port0_dst_mac} qinq 0 48
+p 6 route add 152.16.49.0 24 port 0 ether {port0_dst_mac} qinq 0 49
+p 6 route add 152.16.50.0 24 port 0 ether {port0_dst_mac} qinq 0 50
+p 6 route add 152.16.51.0 24 port 0 ether {port0_dst_mac} qinq 0 51
+p 6 route add 152.16.52.0 24 port 0 ether {port0_dst_mac} qinq 0 52
+p 6 route add 152.16.53.0 24 port 0 ether {port0_dst_mac} qinq 0 53
+p 6 route add 152.16.54.0 24 port 0 ether {port0_dst_mac} qinq 0 54
+p 6 route add 152.16.55.0 24 port 0 ether {port0_dst_mac} qinq 0 55
+p 6 route add 152.16.56.0 24 port 0 ether {port0_dst_mac} qinq 0 56
+p 6 route add 152.16.57.0 24 port 0 ether {port0_dst_mac} qinq 0 57
+p 6 route add 152.16.58.0 24 port 0 ether {port0_dst_mac} qinq 0 58
+p 6 route add 152.16.59.0 24 port 0 ether {port0_dst_mac} qinq 0 59
+p 6 route add 152.16.60.0 24 port 0 ether {port0_dst_mac} qinq 0 60
+p 6 route add 152.16.61.0 24 port 0 ether {port0_dst_mac} qinq 0 61
+p 6 route add 152.16.62.0 24 port 0 ether {port0_dst_mac} qinq 0 62
+p 6 route add 152.16.63.0 24 port 0 ether {port0_dst_mac} qinq 0 63
+p 6 route add 152.16.64.0 24 port 0 ether {port0_dst_mac} qinq 0 64
+p 6 route add 152.16.65.0 24 port 0 ether {port0_dst_mac} qinq 0 65
+p 6 route add 152.16.66.0 24 port 0 ether {port0_dst_mac} qinq 0 66
+p 6 route add 152.16.67.0 24 port 0 ether {port0_dst_mac} qinq 0 67
+p 6 route add 152.16.68.0 24 port 0 ether {port0_dst_mac} qinq 0 68
+p 6 route add 152.16.69.0 24 port 0 ether {port0_dst_mac} qinq 0 69
+p 6 route add 152.16.70.0 24 port 0 ether {port0_dst_mac} qinq 0 70
+p 6 route add 152.16.71.0 24 port 0 ether {port0_dst_mac} qinq 0 71
+p 6 route add 152.16.72.0 24 port 0 ether {port0_dst_mac} qinq 0 72
+p 6 route add 152.16.73.0 24 port 0 ether {port0_dst_mac} qinq 0 73
+p 6 route add 152.16.74.0 24 port 0 ether {port0_dst_mac} qinq 0 74
+p 6 route add 152.16.75.0 24 port 0 ether {port0_dst_mac} qinq 0 75
+p 6 route add 152.16.76.0 24 port 0 ether {port0_dst_mac} qinq 0 76
+p 6 route add 152.16.77.0 24 port 0 ether {port0_dst_mac} qinq 0 77
+p 6 route add 152.16.78.0 24 port 0 ether {port0_dst_mac} qinq 0 78
+p 6 route add 152.16.79.0 24 port 0 ether {port0_dst_mac} qinq 0 79
+p 6 route add 152.16.80.0 24 port 0 ether {port0_dst_mac} qinq 0 80
+p 6 route add 152.16.81.0 24 port 0 ether {port0_dst_mac} qinq 0 81
+p 6 route add 152.16.82.0 24 port 0 ether {port0_dst_mac} qinq 0 82
+p 6 route add 152.16.83.0 24 port 0 ether {port0_dst_mac} qinq 0 83
+p 6 route add 152.16.84.0 24 port 0 ether {port0_dst_mac} qinq 0 84
+p 6 route add 152.16.85.0 24 port 0 ether {port0_dst_mac} qinq 0 85
+p 6 route add 152.16.86.0 24 port 0 ether {port0_dst_mac} qinq 0 86
+p 6 route add 152.16.87.0 24 port 0 ether {port0_dst_mac} qinq 0 87
+p 6 route add 152.16.88.0 24 port 0 ether {port0_dst_mac} qinq 0 88
+p 6 route add 152.16.89.0 24 port 0 ether {port0_dst_mac} qinq 0 89
+p 6 route add 152.16.90.0 24 port 0 ether {port0_dst_mac} qinq 0 90
+p 6 route add 152.16.91.0 24 port 0 ether {port0_dst_mac} qinq 0 91
+p 6 route add 152.16.92.0 24 port 0 ether {port0_dst_mac} qinq 0 92
+p 6 route add 152.16.93.0 24 port 0 ether {port0_dst_mac} qinq 0 93
+p 6 route add 152.16.94.0 24 port 0 ether {port0_dst_mac} qinq 0 94
+p 6 route add 152.16.95.0 24 port 0 ether {port0_dst_mac} qinq 0 95
+p 6 route add 152.16.96.0 24 port 0 ether {port0_dst_mac} qinq 0 96
+p 6 route add 152.16.97.0 24 port 0 ether {port0_dst_mac} qinq 0 97
+p 6 route add 152.16.98.0 24 port 0 ether {port0_dst_mac} qinq 0 98
+p 6 route add 152.16.99.0 24 port 0 ether {port0_dst_mac} qinq 0 99
+p 6 route add 152.16.100.0 24 port 0 ether {port0_dst_mac} qinq 0 100
+p 6 route add 152.16.101.0 24 port 0 ether {port0_dst_mac} qinq 0 101
+p 6 route add 152.16.102.0 24 port 0 ether {port0_dst_mac} qinq 0 102
+p 6 route add 152.16.103.0 24 port 0 ether {port0_dst_mac} qinq 0 103
+p 6 route add 152.16.104.0 24 port 0 ether {port0_dst_mac} qinq 0 104
+p 6 route add 152.16.105.0 24 port 0 ether {port0_dst_mac} qinq 0 105
+p 6 route add 152.16.106.0 24 port 0 ether {port0_dst_mac} qinq 0 106
+p 6 route add 152.16.107.0 24 port 0 ether {port0_dst_mac} qinq 0 107
+p 6 route add 152.16.108.0 24 port 0 ether {port0_dst_mac} qinq 0 108
+p 6 route add 152.16.109.0 24 port 0 ether {port0_dst_mac} qinq 0 109
+p 6 route add 152.16.110.0 24 port 0 ether {port0_dst_mac} qinq 0 110
+p 6 route add 152.16.111.0 24 port 0 ether {port0_dst_mac} qinq 0 111
+p 6 route add 152.16.112.0 24 port 0 ether {port0_dst_mac} qinq 0 112
+p 6 route add 152.16.113.0 24 port 0 ether {port0_dst_mac} qinq 0 113
+p 6 route add 152.16.114.0 24 port 0 ether {port0_dst_mac} qinq 0 114
+p 6 route add 152.16.115.0 24 port 0 ether {port0_dst_mac} qinq 0 115
+p 6 route add 152.16.116.0 24 port 0 ether {port0_dst_mac} qinq 0 116
+p 6 route add 152.16.117.0 24 port 0 ether {port0_dst_mac} qinq 0 117
+p 6 route add 152.16.118.0 24 port 0 ether {port0_dst_mac} qinq 0 118
+p 6 route add 152.16.119.0 24 port 0 ether {port0_dst_mac} qinq 0 119
+p 6 route add 152.16.120.0 24 port 0 ether {port0_dst_mac} qinq 0 120
+p 6 route add 152.16.121.0 24 port 0 ether {port0_dst_mac} qinq 0 121
+p 6 route add 152.16.122.0 24 port 0 ether {port0_dst_mac} qinq 0 122
+p 6 route add 152.16.123.0 24 port 0 ether {port0_dst_mac} qinq 0 123
+p 6 route add 152.16.124.0 24 port 0 ether {port0_dst_mac} qinq 0 124
+p 6 route add 152.16.125.0 24 port 0 ether {port0_dst_mac} qinq 0 125
+p 6 route add 152.16.126.0 24 port 0 ether {port0_dst_mac} qinq 0 126
+p 6 route add 152.16.127.0 24 port 0 ether {port0_dst_mac} qinq 0 127
+p 6 route add 152.16.128.0 24 port 0 ether {port0_dst_mac} qinq 0 128
+p 6 route add 152.16.129.0 24 port 0 ether {port0_dst_mac} qinq 0 129
+p 6 route add 152.16.130.0 24 port 0 ether {port0_dst_mac} qinq 0 130
+p 6 route add 152.16.131.0 24 port 0 ether {port0_dst_mac} qinq 0 131
+p 6 route add 152.16.132.0 24 port 0 ether {port0_dst_mac} qinq 0 132
+p 6 route add 152.16.133.0 24 port 0 ether {port0_dst_mac} qinq 0 133
+p 6 route add 152.16.134.0 24 port 0 ether {port0_dst_mac} qinq 0 134
+p 6 route add 152.16.135.0 24 port 0 ether {port0_dst_mac} qinq 0 135
+p 6 route add 152.16.136.0 24 port 0 ether {port0_dst_mac} qinq 0 136
+p 6 route add 152.16.137.0 24 port 0 ether {port0_dst_mac} qinq 0 137
+p 6 route add 152.16.138.0 24 port 0 ether {port0_dst_mac} qinq 0 138
+p 6 route add 152.16.139.0 24 port 0 ether {port0_dst_mac} qinq 0 139
+p 6 route add 152.16.140.0 24 port 0 ether {port0_dst_mac} qinq 0 140
+p 6 route add 152.16.141.0 24 port 0 ether {port0_dst_mac} qinq 0 141
+p 6 route add 152.16.142.0 24 port 0 ether {port0_dst_mac} qinq 0 142
+p 6 route add 152.16.143.0 24 port 0 ether {port0_dst_mac} qinq 0 143
+p 6 route add 152.16.144.0 24 port 0 ether {port0_dst_mac} qinq 0 144
+p 6 route add 152.16.145.0 24 port 0 ether {port0_dst_mac} qinq 0 145
+p 6 route add 152.16.146.0 24 port 0 ether {port0_dst_mac} qinq 0 146
+p 6 route add 152.16.147.0 24 port 0 ether {port0_dst_mac} qinq 0 147
+p 6 route add 152.16.148.0 24 port 0 ether {port0_dst_mac} qinq 0 148
+p 6 route add 152.16.149.0 24 port 0 ether {port0_dst_mac} qinq 0 149
+p 6 route add 152.16.150.0 24 port 0 ether {port0_dst_mac} qinq 0 150
+p 6 route add 152.16.151.0 24 port 0 ether {port0_dst_mac} qinq 0 151
+p 6 route add 152.16.152.0 24 port 0 ether {port0_dst_mac} qinq 0 152
+p 6 route add 152.16.153.0 24 port 0 ether {port0_dst_mac} qinq 0 153
+p 6 route add 152.16.154.0 24 port 0 ether {port0_dst_mac} qinq 0 154
+p 6 route add 152.16.155.0 24 port 0 ether {port0_dst_mac} qinq 0 155
+p 6 route add 152.16.156.0 24 port 0 ether {port0_dst_mac} qinq 0 156
+p 6 route add 152.16.157.0 24 port 0 ether {port0_dst_mac} qinq 0 157
+p 6 route add 152.16.158.0 24 port 0 ether {port0_dst_mac} qinq 0 158
+p 6 route add 152.16.159.0 24 port 0 ether {port0_dst_mac} qinq 0 159
+p 6 route add 152.16.160.0 24 port 0 ether {port0_dst_mac} qinq 0 160
+p 6 route add 152.16.161.0 24 port 0 ether {port0_dst_mac} qinq 0 161
+p 6 route add 152.16.162.0 24 port 0 ether {port0_dst_mac} qinq 0 162
+p 6 route add 152.16.163.0 24 port 0 ether {port0_dst_mac} qinq 0 163
+p 6 route add 152.16.164.0 24 port 0 ether {port0_dst_mac} qinq 0 164
+p 6 route add 152.16.165.0 24 port 0 ether {port0_dst_mac} qinq 0 165
+p 6 route add 152.16.166.0 24 port 0 ether {port0_dst_mac} qinq 0 166
+p 6 route add 152.16.167.0 24 port 0 ether {port0_dst_mac} qinq 0 167
+p 6 route add 152.16.168.0 24 port 0 ether {port0_dst_mac} qinq 0 168
+p 6 route add 152.16.169.0 24 port 0 ether {port0_dst_mac} qinq 0 169
+p 6 route add 152.16.170.0 24 port 0 ether {port0_dst_mac} qinq 0 170
+p 6 route add 152.16.171.0 24 port 0 ether {port0_dst_mac} qinq 0 171
+p 6 route add 152.16.172.0 24 port 0 ether {port0_dst_mac} qinq 0 172
+p 6 route add 152.16.173.0 24 port 0 ether {port0_dst_mac} qinq 0 173
+p 6 route add 152.16.174.0 24 port 0 ether {port0_dst_mac} qinq 0 174
+p 6 route add 152.16.175.0 24 port 0 ether {port0_dst_mac} qinq 0 175
+p 6 route add 152.16.176.0 24 port 0 ether {port0_dst_mac} qinq 0 176
+p 6 route add 152.16.177.0 24 port 0 ether {port0_dst_mac} qinq 0 177
+p 6 route add 152.16.178.0 24 port 0 ether {port0_dst_mac} qinq 0 178
+p 6 route add 152.16.179.0 24 port 0 ether {port0_dst_mac} qinq 0 179
+p 6 route add 152.16.180.0 24 port 0 ether {port0_dst_mac} qinq 0 180
+p 6 route add 152.16.181.0 24 port 0 ether {port0_dst_mac} qinq 0 181
+p 6 route add 152.16.182.0 24 port 0 ether {port0_dst_mac} qinq 0 182
+p 6 route add 152.16.183.0 24 port 0 ether {port0_dst_mac} qinq 0 183
+p 6 route add 152.16.184.0 24 port 0 ether {port0_dst_mac} qinq 0 184
+p 6 route add 152.16.185.0 24 port 0 ether {port0_dst_mac} qinq 0 185
+p 6 route add 152.16.186.0 24 port 0 ether {port0_dst_mac} qinq 0 186
+p 6 route add 152.16.187.0 24 port 0 ether {port0_dst_mac} qinq 0 187
+p 6 route add 152.16.188.0 24 port 0 ether {port0_dst_mac} qinq 0 188
+p 6 route add 152.16.189.0 24 port 0 ether {port0_dst_mac} qinq 0 189
+p 6 route add 152.16.190.0 24 port 0 ether {port0_dst_mac} qinq 0 190
+p 6 route add 152.16.191.0 24 port 0 ether {port0_dst_mac} qinq 0 191
+p 6 route add 152.16.192.0 24 port 0 ether {port0_dst_mac} qinq 0 192
+p 6 route add 152.16.193.0 24 port 0 ether {port0_dst_mac} qinq 0 193
+p 6 route add 152.16.194.0 24 port 0 ether {port0_dst_mac} qinq 0 194
+p 6 route add 152.16.195.0 24 port 0 ether {port0_dst_mac} qinq 0 195
+p 6 route add 152.16.196.0 24 port 0 ether {port0_dst_mac} qinq 0 196
+p 6 route add 152.16.197.0 24 port 0 ether {port0_dst_mac} qinq 0 197
+p 6 route add 152.16.198.0 24 port 0 ether {port0_dst_mac} qinq 0 198
+p 6 route add 152.16.199.0 24 port 0 ether {port0_dst_mac} qinq 0 199
+p 6 route add 152.16.200.0 24 port 0 ether {port0_dst_mac} qinq 0 200
+p 6 route add 152.16.201.0 24 port 0 ether {port0_dst_mac} qinq 0 201
+p 6 route add 152.16.202.0 24 port 0 ether {port0_dst_mac} qinq 0 202
+p 6 route add 152.16.203.0 24 port 0 ether {port0_dst_mac} qinq 0 203
+p 6 route add 152.16.204.0 24 port 0 ether {port0_dst_mac} qinq 0 204
+p 6 route add 152.16.205.0 24 port 0 ether {port0_dst_mac} qinq 0 205
+p 6 route add 152.16.206.0 24 port 0 ether {port0_dst_mac} qinq 0 206
+p 6 route add 152.16.207.0 24 port 0 ether {port0_dst_mac} qinq 0 207
+p 6 route add 152.16.208.0 24 port 0 ether {port0_dst_mac} qinq 0 208
+p 6 route add 152.16.209.0 24 port 0 ether {port0_dst_mac} qinq 0 209
+p 6 route add 152.16.210.0 24 port 0 ether {port0_dst_mac} qinq 0 210
+p 6 route add 152.16.211.0 24 port 0 ether {port0_dst_mac} qinq 0 211
+p 6 route add 152.16.212.0 24 port 0 ether {port0_dst_mac} qinq 0 212
+p 6 route add 152.16.213.0 24 port 0 ether {port0_dst_mac} qinq 0 213
+p 6 route add 152.16.214.0 24 port 0 ether {port0_dst_mac} qinq 0 214
+p 6 route add 152.16.215.0 24 port 0 ether {port0_dst_mac} qinq 0 215
+p 6 route add 152.16.216.0 24 port 0 ether {port0_dst_mac} qinq 0 216
+p 6 route add 152.16.217.0 24 port 0 ether {port0_dst_mac} qinq 0 217
+p 6 route add 152.16.218.0 24 port 0 ether {port0_dst_mac} qinq 0 218
+p 6 route add 152.16.219.0 24 port 0 ether {port0_dst_mac} qinq 0 219
+p 6 route add 152.16.220.0 24 port 0 ether {port0_dst_mac} qinq 0 220
+p 6 route add 152.16.221.0 24 port 0 ether {port0_dst_mac} qinq 0 221
+p 6 route add 152.16.222.0 24 port 0 ether {port0_dst_mac} qinq 0 222
+p 6 route add 152.16.223.0 24 port 0 ether {port0_dst_mac} qinq 0 223
+p 6 route add 152.16.224.0 24 port 0 ether {port0_dst_mac} qinq 0 224
+p 6 route add 152.16.225.0 24 port 0 ether {port0_dst_mac} qinq 0 225
+p 6 route add 152.16.226.0 24 port 0 ether {port0_dst_mac} qinq 0 226
+p 6 route add 152.16.227.0 24 port 0 ether {port0_dst_mac} qinq 0 227
+p 6 route add 152.16.228.0 24 port 0 ether {port0_dst_mac} qinq 0 228
+p 6 route add 152.16.229.0 24 port 0 ether {port0_dst_mac} qinq 0 229
+p 6 route add 152.16.230.0 24 port 0 ether {port0_dst_mac} qinq 0 230
+p 6 route add 152.16.231.0 24 port 0 ether {port0_dst_mac} qinq 0 231
+p 6 route add 152.16.232.0 24 port 0 ether {port0_dst_mac} qinq 0 232
+p 6 route add 152.16.233.0 24 port 0 ether {port0_dst_mac} qinq 0 233
+p 6 route add 152.16.234.0 24 port 0 ether {port0_dst_mac} qinq 0 234
+p 6 route add 152.16.235.0 24 port 0 ether {port0_dst_mac} qinq 0 235
+p 6 route add 152.16.236.0 24 port 0 ether {port0_dst_mac} qinq 0 236
+p 6 route add 152.16.237.0 24 port 0 ether {port0_dst_mac} qinq 0 237
+p 6 route add 152.16.238.0 24 port 0 ether {port0_dst_mac} qinq 0 238
+p 6 route add 152.16.239.0 24 port 0 ether {port0_dst_mac} qinq 0 239
+p 6 route add 152.16.240.0 24 port 0 ether {port0_dst_mac} qinq 0 240
+p 6 route add 152.16.241.0 24 port 0 ether {port0_dst_mac} qinq 0 241
+p 6 route add 152.16.242.0 24 port 0 ether {port0_dst_mac} qinq 0 242
+p 6 route add 152.16.243.0 24 port 0 ether {port0_dst_mac} qinq 0 243
+p 6 route add 152.16.244.0 24 port 0 ether {port0_dst_mac} qinq 0 244
+p 6 route add 152.16.245.0 24 port 0 ether {port0_dst_mac} qinq 0 245
+p 6 route add 152.16.246.0 24 port 0 ether {port0_dst_mac} qinq 0 246
+p 6 route add 152.16.247.0 24 port 0 ether {port0_dst_mac} qinq 0 247
+p 6 route add 152.16.248.0 24 port 0 ether {port0_dst_mac} qinq 0 248
+p 6 route add 152.16.249.0 24 port 0 ether {port0_dst_mac} qinq 0 249
+p 6 route add 152.16.250.0 24 port 0 ether {port0_dst_mac} qinq 0 250
+p 6 route add 152.16.251.0 24 port 0 ether {port0_dst_mac} qinq 0 251
+p 6 route add 152.16.252.0 24 port 0 ether {port0_dst_mac} qinq 0 252
+p 6 route add 152.16.253.0 24 port 0 ether {port0_dst_mac} qinq 0 253
+p 6 route add 152.16.254.0 24 port 0 ether {port0_dst_mac} qinq 0 254
+p 6 route add 152.16.255.0 24 port 0 ether {port0_dst_mac} qinq 0 255
+p 6 route add default 1
diff --git a/tox.ini b/tox.ini
index 3dfb982bf..bfba8ec0c 100644
--- a/tox.ini
+++ b/tox.ini
@@ -5,6 +5,7 @@ envlist = py27,py3
[testenv]
usedevelop=True
+passenv = http_proxy HTTP_PROXY https_proxy HTTPS_PROXY no_proxy NO_PROXY
deps = -rrequirements.txt
commands = /bin/bash ./run_tests.sh
whitelist_externals = /bin/bash
diff --git a/yardstick/cmd/NSBperf.py b/yardstick/cmd/NSBperf.py
new file mode 100755
index 000000000..dd96b7fc8
--- /dev/null
+++ b/yardstick/cmd/NSBperf.py
@@ -0,0 +1,217 @@
+#!/usr/bin/env python
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+
+"""NSBPERF main script.
+"""
+
+from __future__ import absolute_import
+from __future__ import print_function
+import os
+import argparse
+import json
+import subprocess
+import signal
+
+
+from six.moves import input
+
+CLI_PATH = os.path.dirname(os.path.realpath(__file__))
+REPO_PATH = os.path.abspath(os.path.join(CLI_PATH, os.pardir))
+PYTHONPATH = os.environ.get("PYTHONPATH", False)
+VIRTUAL_ENV = os.environ.get("VIRTUAL_ENV", False)
+
+
+if not PYTHONPATH or not VIRTUAL_ENV:
+ print("Please setup env PYTHONPATH & VIRTUAL_ENV environment varaible.")
+ raise SystemExit(1)
+
+
+def handler():
+ """ Capture ctrl+c and exit cli """
+ subprocess.call(["pkill", "-9", "yardstick"])
+ raise SystemExit(1)
+
+signal.signal(signal.SIGINT, handler)
+
+
+class YardstickNSCli(object):
+ """ This class handles yardstick network serivce testing """
+
+ def __init__(self):
+ super(YardstickNSCli, self).__init__()
+
+ @classmethod
+ def validate_input(cls, choice, choice_len):
+ """ Validate user inputs """
+ if not str(choice):
+ return 1
+
+ choice = int(choice)
+ if not 1 <= choice <= choice_len:
+ print("\nInvalid wrong choice...")
+ input("Press Enter to continue...")
+ return 1
+ subprocess.call(['clear'])
+ return 0
+
+ @classmethod
+ def parse_arguments(cls):
+ """
+ Parse command line arguments.
+ """
+ parser = \
+ argparse.ArgumentParser(
+ prog=__file__,
+ formatter_class=argparse.ArgumentDefaultsHelpFormatter)
+ parser.add_argument('--version', action='version',
+ version='%(prog)s 0.1')
+ parser.add_argument('--list', '--list-tests', action='store_true',
+ help='list all tests and exit')
+ parser.add_argument('--list-vnfs', action='store_true',
+ help='list all system vnfs and exit')
+
+ group = parser.add_argument_group('test selection options')
+ group.add_argument('--vnf', help='vnf to use')
+ group.add_argument('--test', help='test in use')
+
+ args = vars(parser.parse_args())
+
+ return args
+
+ @classmethod
+ def generate_kpi_results(cls, tkey, tgen):
+ """ Generate report for vnf & traffic generator kpis """
+ if tgen:
+ print("\n%s stats" % tkey)
+ print("----------------------------")
+ for key, value in tgen.items():
+ if key != "collect_stats":
+ print(json.dumps({key: value}, indent=2))
+
+ @classmethod
+ def generate_nfvi_results(cls, nfvi):
+ """ Generate report for vnf & traffic generator kpis """
+ if nfvi:
+ nfvi_kpi = {k: v for k, v in nfvi.items() if k == 'collect_stats'}
+ if nfvi_kpi:
+ print("\nNFVi stats")
+ print("----------------------------")
+ for key, value in nfvi_kpi.items():
+ print(json.dumps({key: value}, indent=2))
+
+ def generate_final_report(self, test_case):
+ """ Function will check if partial test results are available
+ and generates final report in rst format.
+"""
+
+ report_caption = '{}\n{} ({})\n{}\n\n'.format(
+ '================================================================',
+ 'Performance report for',
+ os.path.splitext(test_case)[0].upper(),
+ '================================================================')
+ print(report_caption)
+ if os.path.isfile("/tmp/yardstick.out"):
+ lines = []
+ with open("/tmp/yardstick.out") as infile:
+ lines = infile.readlines()
+
+ if lines:
+ tc_res = json.loads(lines.pop(len(lines) - 1))
+ for key, value in tc_res["benchmark"]["data"].items():
+ self.generate_kpi_results(key, value)
+ self.generate_nfvi_results(value)
+
+ @classmethod
+ def handle_list_options(cls, args, test_path):
+ """ Process --list cli arguments if needed
+
+ :param args: A dictionary with all CLI arguments
+ """
+ if args['list_vnfs']:
+ vnfs = os.listdir(test_path)
+ print("VNF :")
+ print("================")
+ for index, vnf in enumerate(vnfs, 1):
+ print((' %-2s %s' % ('%s:' % str(index), vnf)))
+ raise SystemExit(0)
+
+ if args['list']:
+ vnfs = os.listdir(test_path)
+
+ print("Available Tests:")
+ print("*****************")
+ for vnf in vnfs:
+ testcases = os.listdir(test_path + vnf)
+ print(("VNF :(%s)" % vnf))
+ print("================")
+ for testcase in [tc for tc in testcases if "tc" in tc]:
+ print('%s' % testcase)
+ print(os.linesep)
+ raise SystemExit(0)
+
+ @classmethod
+ def terminate_if_less_options(cls, args):
+ """ terminate cli if cmdline options is invalid """
+ if not (args["vnf"] and args["test"]):
+ print("CLI needs option, make sure to pass vnf, test")
+ print("eg: NSBperf.py --vnf <vnf untertest> --test <test yaml>")
+ raise SystemExit(1)
+
+ def run_test(self, args, test_path):
+ """ run requested test """
+ try:
+ vnf = args.get("vnf", "")
+ test = args.get("test", "")
+
+ vnf_dir = test_path + os.sep + vnf
+ if not os.path.exists(vnf_dir):
+ raise ValueError("'%s', vnf not supported." % vnf)
+
+ testcases = [tc for tc in os.listdir(vnf_dir) if "tc" in tc]
+ subtest = set([test]).issubset(testcases)
+ if not subtest:
+ raise ValueError("'%s', testcase not supported." % test)
+
+ os.chdir(vnf_dir)
+ # fixme: Use REST APIs to initiate testcases
+ subprocess.check_output(["yardstick", "--debug",
+ "task", "start", test])
+ self.generate_final_report(test)
+ except (IOError, ValueError):
+ print("Value/I/O error...")
+ except BaseException:
+ print("Test failed. Please verify test inputs & re-run the test..")
+ print("eg: NSBperf.py --vnf <vnf untertest> --test <test yaml>")
+
+ def main(self):
+ """Main function.
+ """
+ test_path = os.path.join(REPO_PATH, "../samples/vnf_samples/nsut/")
+ os.chdir(os.path.join(REPO_PATH, "../"))
+ args = self.parse_arguments()
+
+ # if required, handle list-* operations
+ self.handle_list_options(args, test_path)
+
+ # check for input params
+ self.terminate_if_less_options(args)
+
+ # run test
+ self.run_test(args, test_path)
+
+if __name__ == "__main__":
+ NS_CLI = YardstickNSCli()
+ NS_CLI.main()
diff --git a/yardstick/network_services/traffic_profile/fixed.py b/yardstick/network_services/traffic_profile/fixed.py
new file mode 100644
index 000000000..a456c2bd7
--- /dev/null
+++ b/yardstick/network_services/traffic_profile/fixed.py
@@ -0,0 +1,60 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" Fixed traffic profile definitions """
+
+from __future__ import absolute_import
+
+from yardstick.network_services.traffic_profile.base import TrafficProfile
+from stl.trex_stl_lib.trex_stl_streams import STLTXCont
+from stl.trex_stl_lib.trex_stl_client import STLStream
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLPktBuilder
+from stl.trex_stl_lib import api as Pkt
+
+
+class FixedProfile(TrafficProfile):
+ """
+ This profile adds a single stream at the beginning of the traffic session
+ """
+ def __init__(self, tp_config):
+ super(FixedProfile, self).__init__(tp_config)
+ self.first_run = True
+
+ def execute(self, traffic_generator):
+ if self.first_run:
+ for index, ports in enumerate(traffic_generator.my_ports):
+ ext_intf = \
+ traffic_generator.vnfd["vdu"][0]["external-interface"]
+ virtual_interface = ext_intf[index]["virtual-interface"]
+ src_ip = virtual_interface["local_ip"]
+ dst_ip = virtual_interface["dst_ip"]
+
+ traffic_generator.client.add_streams(
+ self._create_stream(src_ip, dst_ip),
+ ports=[ports])
+
+ traffic_generator.client.start(ports=traffic_generator.my_ports)
+ self.first_run = False
+
+ def _create_stream(self, src_ip, dst_ip):
+ base_frame = \
+ Pkt.Ether() / Pkt.IP(src=src_ip, dst=dst_ip) / Pkt.UDP(dport=12,
+ sport=1025)
+
+ frame_size = self.params["traffic_profile"]["frame_size"]
+ pad_size = max(0, frame_size - len(base_frame))
+ frame = base_frame / ("x" * max(0, pad_size))
+
+ frame_rate = self.params["traffic_profile"]["frame_rate"]
+ return STLStream(packet=STLPktBuilder(pkt=frame),
+ mode=STLTXCont(pps=frame_rate))
diff --git a/yardstick/network_services/traffic_profile/http.py b/yardstick/network_services/traffic_profile/http.py
new file mode 100644
index 000000000..2d00fb849
--- /dev/null
+++ b/yardstick/network_services/traffic_profile/http.py
@@ -0,0 +1,33 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" Generic HTTP profile used by different Traffic generators """
+
+from __future__ import absolute_import
+
+from yardstick.network_services.traffic_profile.base import TrafficProfile
+
+
+class TrafficProfileGenericHTTP(TrafficProfile):
+ """ This Class handles setup of generic http traffic profile """
+
+ def __init__(self, TrafficProfile):
+ super(TrafficProfileGenericHTTP, self).__init__(TrafficProfile)
+
+ def execute(self, traffic_generator):
+ ''' send run traffic for a selected traffic generator'''
+ pass
+
+ def _send_http_request(self, server, port, locator, **kwargs):
+ ''' send http request for a given server, port '''
+ pass
diff --git a/yardstick/network_services/traffic_profile/rfc2544.py b/yardstick/network_services/traffic_profile/rfc2544.py
new file mode 100644
index 000000000..99964d329
--- /dev/null
+++ b/yardstick/network_services/traffic_profile/rfc2544.py
@@ -0,0 +1,106 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" RFC2544 Throughput implemenation """
+
+from __future__ import absolute_import
+from __future__ import division
+import logging
+
+from yardstick.network_services.traffic_profile.traffic_profile \
+ import TrexProfile
+
+LOGGING = logging.getLogger(__name__)
+
+
+class RFC2544Profile(TrexProfile):
+ """ This class handles rfc2544 implemenation. """
+
+ def __init__(self, traffic_generator):
+ super(RFC2544Profile, self).__init__(traffic_generator)
+ self.max_rate = None
+ self.min_rate = None
+ self.rate = 100
+ self.tmp_drop = None
+ self.tmp_throughput = None
+ self.profile_data = None
+
+ def execute(self, traffic_generator):
+ ''' Generate the stream and run traffic on the given ports '''
+ if self.first_run:
+ self.profile_data = self.params.get('private', '')
+ ports = [traffic_generator.my_ports[0]]
+ traffic_generator.client.add_streams(self.get_streams(),
+ ports=ports[0])
+ profile_data = self.params.get('public', '')
+ if profile_data:
+ self.profile_data = profile_data
+ ports.append(traffic_generator.my_ports[1])
+ traffic_generator.client.add_streams(self.get_streams(),
+ ports=ports[1])
+
+ self.max_rate = self.rate
+ self.min_rate = 0
+ traffic_generator.client.start(ports=ports,
+ mult=self.get_multiplier(),
+ duration=30, force=True)
+ self.tmp_drop = 0
+ self.tmp_throughput = 0
+
+ def get_multiplier(self):
+ ''' Get the rate at which next iternation to run '''
+ self.rate = round((self.max_rate + self.min_rate) / 2.0, 2)
+ multiplier = round(self.rate / self.pps, 2)
+ return str(multiplier)
+
+ def get_drop_percentage(self, traffic_generator,
+ samples, tol_min, tolerance):
+ ''' Calculate the drop percentage and run the traffic '''
+ in_packets = sum([samples[iface]['in_packets'] for iface in samples])
+ out_packets = sum([samples[iface]['out_packets'] for iface in samples])
+ packet_drop = abs(out_packets - in_packets)
+ drop_percent = 100.0
+ try:
+ drop_percent = round((packet_drop / float(out_packets)) * 100, 2)
+ except ZeroDivisionError:
+ LOGGING.info('No traffic is flowing')
+ samples['TxThroughput'] = out_packets / 30
+ samples['RxThroughput'] = in_packets / 30
+ samples['CurrentDropPercentage'] = drop_percent
+ samples['Throughput'] = self.tmp_throughput
+ samples['DropPercentage'] = self.tmp_drop
+ if drop_percent > tolerance and self.tmp_throughput == 0:
+ samples['Throughput'] = (in_packets / 30)
+ samples['DropPercentage'] = drop_percent
+ if self.first_run:
+ max_supported_rate = out_packets / 30
+ self.rate = max_supported_rate
+ self.first_run = False
+ if drop_percent > tolerance:
+ self.max_rate = self.rate
+ elif drop_percent < tol_min:
+ self.min_rate = self.rate
+ if drop_percent >= self.tmp_drop:
+ self.tmp_drop = drop_percent
+ self.tmp_throughput = (in_packets / 30)
+ samples['Throughput'] = (in_packets / 30)
+ samples['DropPercentage'] = drop_percent
+ else:
+ samples['Throughput'] = (in_packets / 30)
+ samples['DropPercentage'] = drop_percent
+
+ traffic_generator.client.clear_stats(ports=traffic_generator.my_ports)
+ traffic_generator.client.start(ports=traffic_generator.my_ports,
+ mult=self.get_multiplier(),
+ duration=30, force=True)
+ return samples
diff --git a/yardstick/network_services/traffic_profile/traffic_profile.py b/yardstick/network_services/traffic_profile/traffic_profile.py
new file mode 100644
index 000000000..156cc6644
--- /dev/null
+++ b/yardstick/network_services/traffic_profile/traffic_profile.py
@@ -0,0 +1,499 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" Trex Traffic Profile definitions """
+
+from __future__ import absolute_import
+import struct
+import socket
+import logging
+from random import SystemRandom
+import six
+
+from yardstick.network_services.traffic_profile.base import TrafficProfile
+from stl.trex_stl_lib.trex_stl_client import STLStream
+from stl.trex_stl_lib.trex_stl_streams import STLFlowLatencyStats
+from stl.trex_stl_lib.trex_stl_streams import STLTXCont
+from stl.trex_stl_lib.trex_stl_streams import STLProfile
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLVmWrFlowVar
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLVmFlowVar
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLPktBuilder
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLScVmRaw
+from stl.trex_stl_lib.trex_stl_packet_builder_scapy import STLVmFixIpv4
+from stl.trex_stl_lib import api as Pkt
+
+
+class TrexProfile(TrafficProfile):
+ """ This class handles Trex Traffic profile generation and execution """
+
+ def __init__(self, yaml_data):
+ super(TrexProfile, self).__init__(yaml_data)
+ self.flows = 100
+ self.pps = 100
+ self.pg_id = 0
+ self.first_run = True
+ self.streams = 1
+ self.profile_data = []
+ self.profile = None
+ self.base_pkt = None
+ self.fsize = None
+ self.trex_vm = None
+ self.vms = []
+ self.rate = None
+ self.ip_packet = None
+ self.ip6_packet = None
+ self.udp_packet = None
+ self.udp_dport = ''
+ self.udp_sport = ''
+ self.qinq_packet = None
+ self.qinq = False
+ self.vm_flow_vars = []
+ self.packets = []
+ self.ether_packet = []
+
+ def execute(self, traffic_generator):
+ """ Generate the stream and run traffic on the given ports """
+ pass
+
+ def _set_ether_fields(self, **kwargs):
+ """ set ethernet protocol fields """
+ if not self.ether_packet:
+ self.ether_packet = Pkt.Ether()
+ for key, value in six.iteritems(kwargs):
+ setattr(self.ether_packet, key, value)
+
+ def _set_ip_fields(self, **kwargs):
+ """ set l3 ipv4 protocol fields """
+
+ if not self.ip_packet:
+ self.ip_packet = Pkt.IP()
+ for key in kwargs:
+ setattr(self.ip_packet, key, kwargs[key])
+
+ def _set_ip6_fields(self, **kwargs):
+ """ set l3 ipv6 protocol fields """
+ if not self.ip6_packet:
+ self.ip6_packet = Pkt.IPv6()
+ for key in kwargs:
+ setattr(self.ip6_packet, key, kwargs[key])
+
+ def _set_udp_fields(self, **kwargs):
+ """ set l4 udp ports fields """
+ if not self.udp_packet:
+ self.udp_packet = Pkt.UDP()
+ for key in kwargs:
+ setattr(self.udp_packet, key, kwargs[key])
+
+ def set_src_mac(self, src_mac):
+ """ set source mac address fields """
+ src_macs = src_mac.split('-')
+ min_value = src_macs[0]
+ if len(src_macs) == 1:
+ src_mac = min_value
+ self._set_ether_fields(src=src_mac)
+ else:
+ stl_vm_flow_var = STLVmFlowVar(name="mac_src",
+ min_value=1,
+ max_value=30,
+ size=4,
+ op='inc',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='mac_src',
+ pkt_offset='Ether.src')
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_dst_mac(self, dst_mac):
+ """ set destination mac address fields """
+ dst_macs = dst_mac.split('-')
+ min_value = dst_macs[0]
+ if len(dst_macs) == 1:
+ dst_mac = min_value
+ self._set_ether_fields(dst=dst_mac)
+ else:
+ stl_vm_flow_var = STLVmFlowVar(name="mac_dst",
+ min_value=1,
+ max_value=30,
+ size=4,
+ op='inc',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='mac_dst',
+ pkt_offset='Ether.dst')
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_src_ip4(self, src_ip4):
+ """ set source ipv4 address fields """
+ src_ips = src_ip4.split('-')
+ min_value = src_ips[0]
+ max_value = src_ips[1] if len(src_ips) == 2 else src_ips[0]
+ if len(src_ips) == 1:
+ src_ip4 = min_value
+ self._set_ip_fields(src=src_ip4)
+ else:
+ stl_vm_flow_var = STLVmFlowVar(name="ip4_src",
+ min_value=min_value,
+ max_value=max_value,
+ size=4,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='ip4_src',
+ pkt_offset='IP.src')
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+ stl_vm_fix_ipv4 = STLVmFixIpv4(offset="IP")
+ self.vm_flow_vars.append(stl_vm_fix_ipv4)
+
+ def set_dst_ip4(self, dst_ip4):
+ """ set destination ipv4 address fields """
+ dst_ips = dst_ip4.split('-')
+ min_value = dst_ips[0]
+ max_value = dst_ips[1] if len(dst_ips) == 2 else dst_ips[0]
+ if len(dst_ips) == 1:
+ dst_ip4 = min_value
+ self._set_ip_fields(dst=dst_ip4)
+ else:
+ stl_vm_flow_var = STLVmFlowVar(name="dst_ip4",
+ min_value=min_value,
+ max_value=max_value,
+ size=4,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='dst_ip4',
+ pkt_offset='IP.dst')
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+ stl_vm_fix_ipv4 = STLVmFixIpv4(offset="IP")
+ self.vm_flow_vars.append(stl_vm_fix_ipv4)
+
+ def set_src_ip6(self, src_ip6):
+ """ set source ipv6 address fields """
+ src_ips = src_ip6.split('-')
+ min_value = src_ips[0]
+ max_value = src_ips[1] if len(src_ips) == 2 else src_ips[0]
+ src_ip6 = min_value
+ self._set_ip6_fields(src=src_ip6)
+ if len(src_ips) == 2:
+ min_value, max_value = \
+ self._get_start_end_ipv6(min_value, max_value)
+ stl_vm_flow_var = STLVmFlowVar(name="ip6_src",
+ min_value=min_value,
+ max_value=max_value,
+ size=8,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='ip6_src',
+ pkt_offset='IPv6.src',
+ offset_fixup=8)
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_dst_ip6(self, dst_ip6):
+ """ set destination ipv6 address fields """
+ dst_ips = dst_ip6.split('-')
+ min_value = dst_ips[0]
+ max_value = dst_ips[1] if len(dst_ips) == 2 else dst_ips[0]
+ dst_ip6 = min_value
+ self._set_ip6_fields(dst=dst_ip6)
+ if len(dst_ips) == 2:
+ min_value, max_value = \
+ self._get_start_end_ipv6(min_value, max_value)
+ stl_vm_flow_var = STLVmFlowVar(name="dst_ip6",
+ min_value=min_value,
+ max_value=max_value,
+ size=8,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='dst_ip6',
+ pkt_offset='IPv6.dst',
+ offset_fixup=8)
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_dscp(self, dscp):
+ """ set dscp for trex """
+ dscps = str(dscp).split('-')
+ min_value = int(dscps[0])
+ max_value = int(dscps[1]) if len(dscps) == 2 else int(dscps[0])
+ if len(dscps) == 1:
+ dscp = min_value
+ self._set_ip_fields(tos=dscp)
+ else:
+ stl_vm_flow_var = STLVmFlowVar(name="dscp",
+ min_value=min_value,
+ max_value=max_value,
+ size=2,
+ op='inc',
+ step=8)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='dscp',
+ pkt_offset='IP.tos')
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_src_port(self, src_port):
+ """ set packet source port """
+ src_ports = str(src_port).split('-')
+ min_value = int(src_ports[0])
+ if len(src_ports) == 1:
+ max_value = int(src_ports[0])
+ src_port = min_value
+ self._set_udp_fields(sport=src_port)
+ else:
+ max_value = int(src_ports[1])
+ stl_vm_flow_var = STLVmFlowVar(name="port_src",
+ min_value=min_value,
+ max_value=max_value,
+ size=2,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='port_src',
+ pkt_offset=self.udp_sport)
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_dst_port(self, dst_port):
+ """ set packet destnation port """
+ dst_ports = str(dst_port).split('-')
+ min_value = int(dst_ports[0])
+ if len(dst_ports) == 1:
+ max_value = int(dst_ports[0])
+ dst_port = min_value
+ self._set_udp_fields(dport=dst_port)
+ else:
+ max_value = int(dst_ports[1])
+ stl_vm_flow_var = STLVmFlowVar(name="port_dst",
+ min_value=min_value,
+ max_value=max_value,
+ size=2,
+ op='random',
+ step=1)
+ self.vm_flow_vars.append(stl_vm_flow_var)
+ stl_vm_wr_flow_var = STLVmWrFlowVar(fv_name='port_dst',
+ pkt_offset=self.udp_dport)
+ self.vm_flow_vars.append(stl_vm_wr_flow_var)
+
+ def set_svlan_cvlan(self, svlan, cvlan):
+ """ set svlan & cvlan """
+ self.qinq = True
+ ether_params = {'type': 0x8100}
+ self._set_ether_fields(**ether_params)
+ svlans = str(svlan['id']).split('-')
+ svlan_min = int(svlans[0])
+ svlan_max = int(svlans[1]) if len(svlans) == 2 else int(svlans[0])
+ if len(svlans) == 2:
+ svlan = self._get_random_value(svlan_min, svlan_max)
+ else:
+ svlan = svlan_min
+ cvlans = str(cvlan['id']).split('-')
+ cvlan_min = int(cvlans[0])
+ cvlan_max = int(cvlans[1]) if len(cvlans) == 2 else int(cvlans[0])
+ if len(cvlans) == 2:
+ cvlan = self._get_random_value(cvlan_min, cvlan_max)
+ else:
+ cvlan = cvlan_min
+ self.qinq_packet = Pkt.Dot1Q(vlan=svlan) / Pkt.Dot1Q(vlan=cvlan)
+
+ def set_qinq(self, qinq):
+ """ set qinq in packet """
+ self.set_svlan_cvlan(qinq['S-VLAN'], qinq['C-VLAN'])
+
+ def set_outer_l2_fields(self, outer_l2):
+ """ setup outer l2 fields from traffic profile """
+ ether_params = {'type': 0x800}
+ self._set_ether_fields(**ether_params)
+ if 'srcmac' in outer_l2:
+ self.set_src_mac(outer_l2['srcmac'])
+ if 'dstmac' in outer_l2:
+ self.set_dst_mac(outer_l2['dstmac'])
+ if 'QinQ' in outer_l2:
+ self.set_qinq(outer_l2['QinQ'])
+
+ def set_outer_l3v4_fields(self, outer_l3v4):
+ """ setup outer l3v4 fields from traffic profile """
+ ip_params = {}
+ if 'proto' in outer_l3v4:
+ ip_params['proto'] = outer_l3v4['proto']
+ if outer_l3v4['proto'] == 'tcp':
+ self.udp_packet = Pkt.TCP()
+ self.udp_dport = 'TCP.dport'
+ self.udp_sport = 'TCP.sport'
+ tcp_params = {'flags': '', 'window': 0}
+ self._set_udp_fields(**tcp_params)
+ if 'ttl' in outer_l3v4:
+ ip_params['ttl'] = outer_l3v4['ttl']
+ self._set_ip_fields(**ip_params)
+ if 'dscp' in outer_l3v4:
+ self.set_dscp(outer_l3v4['dscp'])
+ if 'srcip4' in outer_l3v4:
+ self.set_src_ip4(outer_l3v4['srcip4'])
+ if 'dstip4' in outer_l3v4:
+ self.set_dst_ip4(outer_l3v4['dstip4'])
+
+ def set_outer_l3v6_fields(self, outer_l3v6):
+ """ setup outer l3v6 fields from traffic profile """
+ ether_params = {'type': 0x86dd}
+ self._set_ether_fields(**ether_params)
+ ip6_params = {}
+ if 'proto' in outer_l3v6:
+ ip6_params['proto'] = outer_l3v6['proto']
+ if outer_l3v6['proto'] == 'tcp':
+ self.udp_packet = Pkt.TCP()
+ self.udp_dport = 'TCP.dport'
+ self.udp_sport = 'TCP.sport'
+ tcp_params = {'flags': '', 'window': 0}
+ self._set_udp_fields(**tcp_params)
+ if 'ttl' in outer_l3v6:
+ ip6_params['ttl'] = outer_l3v6['ttl']
+ if 'tc' in outer_l3v6:
+ ip6_params['tc'] = outer_l3v6['tc']
+ if 'hlim' in outer_l3v6:
+ ip6_params['hlim'] = outer_l3v6['hlim']
+ self._set_ip6_fields(**ip6_params)
+ if 'srcip6' in outer_l3v6:
+ self.set_src_ip6(outer_l3v6['srcip6'])
+ if 'dstip6' in outer_l3v6:
+ self.set_dst_ip6(outer_l3v6['dstip6'])
+
+ def set_outer_l4_fields(self, outer_l4):
+ """ setup outer l4 fields from traffic profile """
+ if 'srcport' in outer_l4:
+ self.set_src_port(outer_l4['srcport'])
+ if 'dstport' in outer_l4:
+ self.set_dst_port(outer_l4['dstport'])
+
+ def generate_imix_data(self, packet_definition):
+ """ generate packet size for a given traffic profile """
+ imix_count = {}
+ imix_data = {}
+ if not packet_definition:
+ return imix_count
+ imix = packet_definition.get('framesize')
+ if imix:
+ for size in imix:
+ data = imix[size]
+ imix_data[int(size[:-1])] = int(data)
+ imix_sum = sum(imix_data.values())
+ if imix_sum > 100:
+ raise SystemExit("Error in IMIX data")
+ elif imix_sum < 100:
+ imix_data[64] = imix_data.get(64, 0) + (100 - imix_sum)
+
+ avg_size = 0.0
+ for size in imix_data:
+ count = int(imix_data[size])
+ if count:
+ avg_size += round(size * count / 100, 2)
+ pps = round(self.pps * count / 100, 0)
+ imix_count[size] = pps
+ self.rate = round(1342177280 / avg_size, 0) * 2
+ logging.debug("Imax: %s rate: %s", imix_count, self.rate)
+ return imix_count
+
+ def get_streams(self):
+ """ generate trex stream """
+ self.streams = []
+ self.pps = self.params['traffic_profile'].get('frame_rate', 100)
+ for packet_name in self.profile_data:
+ outer_l2 = self.profile_data[packet_name].get('outer_l2')
+ imix_data = self.generate_imix_data(outer_l2)
+ if not imix_data:
+ imix_data = {64: self.pps}
+ self.generate_vm(self.profile_data[packet_name])
+ for size in imix_data:
+ self._generate_streams(size, imix_data[size])
+ self._generate_profile()
+ return self.profile
+
+ def generate_vm(self, packet_definition):
+ """ generate trex vm with flows setup """
+ self.ether_packet = Pkt.Ether()
+ self.ip_packet = Pkt.IP()
+ self.ip6_packet = None
+ self.udp_packet = Pkt.UDP()
+ self.udp_dport = 'UDP.dport'
+ self.udp_sport = 'UDP.sport'
+ self.qinq = False
+ self.vm_flow_vars = []
+ outer_l2 = packet_definition.get('outer_l2', None)
+ outer_l3v4 = packet_definition.get('outer_l3v4', None)
+ outer_l3v6 = packet_definition.get('outer_l3v6', None)
+ outer_l4 = packet_definition.get('outer_l4', None)
+ if outer_l2:
+ self.set_outer_l2_fields(outer_l2)
+ if outer_l3v4:
+ self.set_outer_l3v4_fields(outer_l3v4)
+ if outer_l3v6:
+ self.set_outer_l3v6_fields(outer_l3v6)
+ if outer_l4:
+ self.set_outer_l4_fields(outer_l4)
+ self.trex_vm = STLScVmRaw(self.vm_flow_vars)
+
+ def generate_packets(self):
+ """ generate packets from trex TG """
+ base_pkt = self.base_pkt
+ size = self.fsize - 4
+ pad = max(0, size - len(base_pkt)) * 'x'
+ self.packets = [STLPktBuilder(pkt=base_pkt / pad,
+ vm=vm) for vm in self.vms]
+
+ def _create_single_packet(self, size=64):
+ size = size - 4
+ ether_packet = self.ether_packet
+ ip_packet = self.ip6_packet if self.ip6_packet else self.ip_packet
+ udp_packet = self.udp_packet
+ if self.qinq:
+ qinq_packet = self.qinq_packet
+ base_pkt = ether_packet / qinq_packet / ip_packet / udp_packet
+ else:
+ base_pkt = ether_packet / ip_packet / udp_packet
+ pad = max(0, size - len(base_pkt)) * 'x'
+ packet = STLPktBuilder(pkt=base_pkt / pad, vm=self.trex_vm)
+ return packet
+
+ def _create_single_stream(self, packet_size, pps, isg=0):
+ packet = self._create_single_packet(packet_size)
+ if self.pg_id:
+ self.pg_id += 1
+ stl_flow = STLFlowLatencyStats(pg_id=self.pg_id)
+ stream = STLStream(isg=isg, packet=packet, mode=STLTXCont(pps=pps),
+ flow_stats=stl_flow)
+ else:
+ stream = STLStream(isg=isg, packet=packet, mode=STLTXCont(pps=pps))
+ return stream
+
+ def _generate_streams(self, packet_size, pps):
+ self.streams.append(self._create_single_stream(packet_size, pps))
+
+ def _generate_profile(self):
+ self.profile = STLProfile(self.streams)
+
+ @classmethod
+ def _get_start_end_ipv6(cls, start_ip, end_ip):
+ try:
+ ip1 = socket.inet_pton(socket.AF_INET6, start_ip)
+ ip2 = socket.inet_pton(socket.AF_INET6, end_ip)
+ hi1, lo1 = struct.unpack('!QQ', ip1)
+ hi2, lo2 = struct.unpack('!QQ', ip2)
+ if ((hi1 << 64) | lo1) > ((hi2 << 64) | lo2):
+ raise SystemExit("IPv6: start_ip is greater then end_ip")
+ max_p1 = abs(int(lo1) - int(lo2))
+ base_p1 = lo1
+ except Exception as ex_error:
+ raise SystemExit(ex_error)
+ else:
+ return base_p1, max_p1 + base_p1
+
+ @classmethod
+ def _get_random_value(cls, min_port, max_port):
+ cryptogen = SystemRandom()
+ return cryptogen.randrange(min_port, max_port)
diff --git a/yardstick/network_services/vnf_generic/vnf/tg_ping.py b/yardstick/network_services/vnf_generic/vnf/tg_ping.py
new file mode 100644
index 000000000..2844a5c01
--- /dev/null
+++ b/yardstick/network_services/vnf_generic/vnf/tg_ping.py
@@ -0,0 +1,167 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" PING acts as traffic generation and vnf definitions based on IETS Spec """
+
+from __future__ import absolute_import
+from __future__ import print_function
+import logging
+import multiprocessing
+import re
+import time
+import os
+
+from yardstick import ssh
+from yardstick.network_services.vnf_generic.vnf.base import GenericTrafficGen
+from yardstick.network_services.utils import provision_tool
+
+LOG = logging.getLogger(__name__)
+
+
+class PingParser(object):
+ """ Class providing file-like API for talking with SSH connection """
+
+ def __init__(self, q_out):
+ self.queue = q_out
+ self.closed = False
+
+ def write(self, chunk):
+ """ 64 bytes from 10.102.22.93: icmp_seq=1 ttl=64 time=0.296 ms """
+ match = re.search(r"icmp_seq=(\d+).*time=([0-9.]+)", chunk)
+ LOG.debug("Parser called on %s", chunk)
+ if match:
+ # IMPORTANT: in order for the data to be properly taken
+ # in by InfluxDB, it needs to be converted to numeric types
+ self.queue.put({"packets_received": float(match.group(1)),
+ "rtt": float(match.group(2))})
+
+ def close(self):
+ ''' close the ssh connection '''
+ pass
+
+ def clear(self):
+ ''' clear queue till Empty '''
+ while self.queue.qsize() > 0:
+ self.queue.get()
+
+
+class PingTrafficGen(GenericTrafficGen):
+ """
+ This traffic generator can ping a single IP with pingsize
+ and target given in traffic profile
+ """
+
+ def __init__(self, vnfd):
+ super(PingTrafficGen, self).__init__(vnfd)
+ self._result = {}
+ self._parser = None
+ self._queue = None
+ self._traffic_process = None
+
+ mgmt_interface = vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ LOG.debug("Connecting to %s", mgmt_interface["ip"])
+
+ self.connection = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ self.connection.wait()
+
+ def _bind_device_kernel(self, connection):
+ dpdk_nic_bind = \
+ provision_tool(self.connection,
+ os.path.join(self.bin_path, "dpdk_nic_bind.py"))
+
+ drivers = {intf["virtual-interface"]["vpci"]:
+ intf["virtual-interface"]["driver"]
+ for intf in self.vnfd["vdu"][0]["external-interface"]}
+
+ commands = \
+ ['"{0}" --force -b "{1}" "{2}"'.format(dpdk_nic_bind, value, key)
+ for key, value in drivers.items()]
+ for command in commands:
+ connection.execute(command)
+
+ for index, out in enumerate(self.vnfd["vdu"][0]["external-interface"]):
+ vpci = out["virtual-interface"]["vpci"]
+ net = "find /sys/class/net -lname '*{}*' -printf '%f'".format(vpci)
+ out = connection.execute(net)[1]
+ ifname = out.split('/')[-1].strip('\n')
+ self.vnfd["vdu"][0]["external-interface"][index][
+ "virtual-interface"]["local_iface_name"] = ifname
+
+ def scale(self, flavor=""):
+ ''' scale vnfbased on flavor input '''
+ super(PingTrafficGen, self).scale(flavor)
+
+ def instantiate(self, scenario_cfg, context_cfg):
+ self._result = {"packets_received": 0, "rtt": 0}
+ self._bind_device_kernel(self.connection)
+
+ def run_traffic(self, traffic_profile):
+ self._queue = multiprocessing.Queue()
+ self._parser = PingParser(self._queue)
+ self._traffic_process = \
+ multiprocessing.Process(target=self._traffic_runner,
+ args=(traffic_profile, self._parser))
+ self._traffic_process.start()
+ # Wait for traffic process to start
+ time.sleep(4)
+ return self._traffic_process.is_alive()
+
+ def listen_traffic(self, traffic_profile):
+ """ Not needed for ping
+
+ :param traffic_profile:
+ :return:
+ """
+ pass
+
+ def _traffic_runner(self, traffic_profile, filewrapper):
+
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ self.connection = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ self.connection.wait()
+ external_interface = self.vnfd["vdu"][0]["external-interface"]
+ virtual_interface = external_interface[0]["virtual-interface"]
+ target_ip = virtual_interface["dst_ip"].split('/')[0]
+ local_ip = virtual_interface["local_ip"].split('/')[0]
+ local_if_name = \
+ virtual_interface["local_iface_name"].split('/')[0]
+ packet_size = traffic_profile.params["traffic_profile"]["frame_size"]
+
+ run_cmd = []
+
+ run_cmd.append("ip addr flush %s" % local_if_name)
+ run_cmd.append("ip addr add %s/24 dev %s" % (local_ip, local_if_name))
+ run_cmd.append("ip link set %s up" % local_if_name)
+
+ for cmd in run_cmd:
+ self.connection.execute(cmd)
+
+ ping_cmd = ("ping -s %s %s" % (packet_size, target_ip))
+ self.connection.run(ping_cmd, stdout=filewrapper,
+ keep_stdin_open=True, pty=True)
+
+ def collect_kpi(self):
+ if not self._queue.empty():
+ kpi = self._queue.get()
+ self._result.update(kpi)
+ return self._result
+
+ def terminate(self):
+ if self._traffic_process is not None:
+ self._traffic_process.terminate()
diff --git a/yardstick/network_services/vnf_generic/vnf/tg_rfc2544_trex.py b/yardstick/network_services/vnf_generic/vnf/tg_rfc2544_trex.py
new file mode 100644
index 000000000..37c1a7345
--- /dev/null
+++ b/yardstick/network_services/vnf_generic/vnf/tg_rfc2544_trex.py
@@ -0,0 +1,285 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" Trex traffic generation definitions which implements rfc2544 """
+
+from __future__ import absolute_import
+from __future__ import print_function
+import multiprocessing
+import time
+import logging
+import os
+import yaml
+
+from yardstick import ssh
+from yardstick.network_services.vnf_generic.vnf.base import GenericTrafficGen
+from yardstick.network_services.utils import get_nsb_option
+from stl.trex_stl_lib.trex_stl_client import STLClient
+from stl.trex_stl_lib.trex_stl_client import LoggerApi
+from stl.trex_stl_lib.trex_stl_exceptions import STLError
+
+LOGGING = logging.getLogger(__name__)
+
+DURATION = 30
+WAIT_TIME = 3
+TREX_SYNC_PORT = 4500
+TREX_ASYNC_PORT = 4501
+
+
+class TrexTrafficGenRFC(GenericTrafficGen):
+ """
+ This class handles mapping traffic profile and generating
+ traffic for rfc2544 testcase.
+ """
+
+ def __init__(self, vnfd):
+ super(TrexTrafficGenRFC, self).__init__(vnfd)
+ self._result = {}
+ self._terminated = multiprocessing.Value('i', 0)
+ self._queue = multiprocessing.Queue()
+ self._terminated = multiprocessing.Value('i', 0)
+ self._traffic_process = None
+ self._vpci_ascending = None
+ self.tc_file_name = None
+ self.client = None
+ self.my_ports = None
+
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ self.connection = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ self.connection.wait()
+
+ @classmethod
+ def _split_mac_address_into_list(cls, mac):
+ octets = mac.split(':')
+ for i, elem in enumerate(octets):
+ octets[i] = "0x" + str(elem)
+ return octets
+
+ def _generate_trex_cfg(self, vnfd):
+ """
+
+ :param vnfd: vnfd.yaml
+ :return: trex_cfg.yaml file
+ """
+ trex_cfg = dict(
+ port_limit=0,
+ version='2',
+ interfaces=[],
+ port_info=list(dict(
+ ))
+ )
+ trex_cfg["port_limit"] = len(vnfd["vdu"][0]["external-interface"])
+ trex_cfg["version"] = '2'
+
+ cfg_file = []
+ vpci = []
+ port = {}
+
+ ext_intf = vnfd["vdu"][0]["external-interface"]
+ for interface in ext_intf:
+ virt_intf = interface["virtual-interface"]
+ vpci.append(virt_intf["vpci"])
+
+ port["src_mac"] = \
+ self._split_mac_address_into_list(virt_intf["local_mac"])
+
+ time.sleep(WAIT_TIME)
+ port["dest_mac"] = \
+ self._split_mac_address_into_list(virt_intf["dst_mac"])
+ if virt_intf["dst_mac"]:
+ trex_cfg["port_info"].append(port.copy())
+
+ trex_cfg["interfaces"] = vpci
+ cfg_file.append(trex_cfg)
+
+ with open('/tmp/trex_cfg.yaml', 'w') as outfile:
+ outfile.write(yaml.safe_dump(cfg_file, default_flow_style=False))
+ self.connection.put('/tmp/trex_cfg.yaml', '/etc')
+
+ self._vpci_ascending = sorted(vpci)
+
+ def scale(self, flavor=""):
+ ''' scale vnfbased on flavor input '''
+ super(TrexTrafficGenRFC, self).scale(flavor)
+
+ def instantiate(self, scenario_cfg, context_cfg):
+ self._generate_trex_cfg(self.vnfd)
+ self.tc_file_name = '{0}.yaml'.format(scenario_cfg['tc'])
+ trex = os.path.join(self.bin_path, "trex")
+ err, _, _ = \
+ self.connection.execute("ls {} >/dev/null 2>&1".format(trex))
+ if err != 0:
+ self.connection.put(trex, trex, True)
+
+ LOGGING.debug("Starting TRex server...")
+ _tg_server = \
+ multiprocessing.Process(target=self._start_server)
+ _tg_server.start()
+ while True:
+ LOGGING.info("Waiting for TG Server to start.. ")
+ time.sleep(WAIT_TIME)
+
+ status = \
+ self.connection.execute("lsof -i:%s" % TREX_SYNC_PORT)[0]
+ if status == 0:
+ LOGGING.info("TG server is up and running.")
+ return _tg_server.exitcode
+ if not _tg_server.is_alive():
+ raise RuntimeError("Traffic Generator process died.")
+
+ def listen_traffic(self, traffic_profile):
+ pass
+
+ def _get_logical_if_name(self, vpci):
+ ext_intf = self.vnfd["vdu"][0]["external-interface"]
+ for interface in range(len(self.vnfd["vdu"][0]["external-interface"])):
+ virtual_intf = ext_intf[interface]["virtual-interface"]
+ if virtual_intf["vpci"] == vpci:
+ return ext_intf[interface]["name"]
+
+ def run_traffic(self, traffic_profile,
+ client_started=multiprocessing.Value('i', 0)):
+
+ self._traffic_process = \
+ multiprocessing.Process(target=self._traffic_runner,
+ args=(traffic_profile, self._queue,
+ client_started, self._terminated))
+ self._traffic_process.start()
+ # Wait for traffic process to start
+ while client_started.value == 0:
+ time.sleep(1)
+
+ return self._traffic_process.is_alive()
+
+ def _start_server(self):
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ _server = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ _server.wait()
+
+ _server.execute("fuser -n tcp %s %s -k > /dev/null 2>&1" %
+ (TREX_SYNC_PORT, TREX_ASYNC_PORT))
+ _server.execute("pkill -9 rex > /dev/null 2>&1")
+
+ trex_path = os.path.join(self.bin_path, "trex/scripts")
+ path = get_nsb_option("trex_path", trex_path)
+ trex_cmd = "cd " + path + "; sudo ./t-rex-64 -i > /dev/null 2>&1"
+
+ _server.execute(trex_cmd)
+
+ def _connect_client(self, client=None):
+ if client is None:
+ client = STLClient(username=self.vnfd["mgmt-interface"]["user"],
+ server=self.vnfd["mgmt-interface"]["ip"],
+ verbose_level=LoggerApi.VERBOSE_QUIET)
+ for idx in range(6):
+ try:
+ client.connect()
+ break
+ except STLError:
+ LOGGING.info("Unable to connect to Trex. Attempt %s", idx)
+ time.sleep(WAIT_TIME)
+ return client
+
+ @classmethod
+ def _get_rfc_tolerance(cls, tc_yaml):
+ tolerance = '0.8 - 1.0'
+ if 'tc_options' in tc_yaml['scenarios'][0]:
+ tc_options = tc_yaml['scenarios'][0]['tc_options']
+ if 'rfc2544' in tc_options:
+ tolerance = \
+ tc_options['rfc2544'].get('allowed_drop_rate', '0.8 - 1.0')
+
+ tolerance = tolerance.split('-')
+ min_tol = float(tolerance[0])
+ if len(tolerance) == 2:
+ max_tol = float(tolerance[1])
+ else:
+ max_tol = float(tolerance[0])
+
+ return [min_tol, max_tol]
+
+ def _traffic_runner(self, traffic_profile, queue,
+ client_started, terminated):
+ LOGGING.info("Starting TRex client...")
+ tc_yaml = {}
+
+ with open(self.tc_file_name) as tc_file:
+ tc_yaml = yaml.load(tc_file.read())
+
+ tolerance = self._get_rfc_tolerance(tc_yaml)
+
+ # fixme: fix passing correct trex config file,
+ # instead of searching the default path
+ self.my_ports = [0, 1]
+ self.client = self._connect_client()
+ self.client.reset(ports=self.my_ports)
+ self.client.remove_all_streams(self.my_ports) # remove all streams
+ while not terminated.value:
+ traffic_profile.execute(self)
+ client_started.value = 1
+ time.sleep(DURATION)
+ self.client.stop(self.my_ports)
+ time.sleep(WAIT_TIME)
+ last_res = self.client.get_stats(self.my_ports)
+ samples = {}
+ for vpci_idx in range(len(self._vpci_ascending)):
+ name = \
+ self._get_logical_if_name(self._vpci_ascending[vpci_idx])
+ # fixme: VNFDs KPIs values needs to be mapped to TRex structure
+ if not isinstance(last_res, dict):
+ terminated.value = 1
+ last_res = {}
+
+ samples[name] = \
+ {"rx_throughput_fps":
+ float(last_res.get(vpci_idx, {}).get("rx_pps", 0.0)),
+ "tx_throughput_fps":
+ float(last_res.get(vpci_idx, {}).get("tx_pps", 0.0)),
+ "rx_throughput_mbps":
+ float(last_res.get(vpci_idx, {}).get("rx_bps", 0.0)),
+ "tx_throughput_mbps":
+ float(last_res.get(vpci_idx, {}).get("tx_bps", 0.0)),
+ "in_packets":
+ last_res.get(vpci_idx, {}).get("ipackets", 0),
+ "out_packets":
+ last_res.get(vpci_idx, {}).get("opackets", 0)}
+
+ samples = \
+ traffic_profile.get_drop_percentage(self, samples,
+ tolerance[0], tolerance[1])
+ queue.put(samples)
+ self.client.stop(self.my_ports)
+ self.client.disconnect()
+ queue.put(samples)
+
+ def collect_kpi(self):
+ if not self._queue.empty():
+ result = self._queue.get()
+ self._result.update(result)
+ LOGGING.debug("trex collect Kpis %s", self._result)
+ return self._result
+
+ def terminate(self):
+ self._terminated.value = 1 # stop Trex clinet
+
+ self.connection.execute("fuser -n tcp %s %s -k > /dev/null 2>&1" %
+ (TREX_SYNC_PORT, TREX_ASYNC_PORT))
+
+ if self._traffic_process:
+ self._traffic_process.terminate()
diff --git a/yardstick/network_services/vnf_generic/vnf/tg_trex.py b/yardstick/network_services/vnf_generic/vnf/tg_trex.py
new file mode 100644
index 000000000..2731476e0
--- /dev/null
+++ b/yardstick/network_services/vnf_generic/vnf/tg_trex.py
@@ -0,0 +1,278 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" Trex acts as traffic generation and vnf definitions based on IETS Spec """
+
+from __future__ import absolute_import
+from __future__ import print_function
+import multiprocessing
+import time
+import logging
+import os
+import yaml
+
+from yardstick import ssh
+from yardstick.network_services.vnf_generic.vnf.base import GenericTrafficGen
+from yardstick.network_services.utils import get_nsb_option
+from yardstick.network_services.utils import provision_tool
+from stl.trex_stl_lib.trex_stl_client import STLClient
+from stl.trex_stl_lib.trex_stl_client import LoggerApi
+from stl.trex_stl_lib.trex_stl_exceptions import STLError
+
+LOG = logging.getLogger(__name__)
+DURATION = 30
+TREX_SYNC_PORT = 4500
+TREX_ASYNC_PORT = 4501
+
+
+class TrexTrafficGen(GenericTrafficGen):
+ """
+ This class handles mapping traffic profile and generating
+ traffic for given testcase
+ """
+
+ def __init__(self, vnfd):
+ super(TrexTrafficGen, self).__init__(vnfd)
+ self._result = {}
+ self._queue = multiprocessing.Queue()
+ self._terminated = multiprocessing.Value('i', 0)
+ self._traffic_process = None
+ self._vpci_ascending = None
+ self.client = None
+ self.my_ports = None
+ self.client_started = multiprocessing.Value('i', 0)
+
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ self.connection = ssh.SSH(mgmt_interface["user"],
+ mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ self.connection.wait()
+
+ @classmethod
+ def _split_mac_address_into_list(cls, mac):
+ octets = mac.split(':')
+ for i, elem in enumerate(octets):
+ octets[i] = "0x" + str(elem)
+ return octets
+
+ def _generate_trex_cfg(self, vnfd):
+ """
+
+ :param vnfd: vnfd.yaml
+ :return: trex_cfg.yaml file
+ """
+ trex_cfg = dict(
+ port_limit=0,
+ version='2',
+ interfaces=[],
+ port_info=list(dict(
+ ))
+ )
+ trex_cfg["port_limit"] = len(vnfd["vdu"][0]["external-interface"])
+ trex_cfg["version"] = '2'
+
+ cfg_file = []
+ vpci = []
+ port = {}
+
+ for interface in range(len(vnfd["vdu"][0]["external-interface"])):
+ ext_intrf = vnfd["vdu"][0]["external-interface"]
+ virtual_interface = ext_intrf[interface]["virtual-interface"]
+ vpci.append(virtual_interface["vpci"])
+
+ port["src_mac"] = self._split_mac_address_into_list(
+ virtual_interface["local_mac"])
+ port["dest_mac"] = self._split_mac_address_into_list(
+ virtual_interface["dst_mac"])
+
+ trex_cfg["port_info"].append(port.copy())
+
+ trex_cfg["interfaces"] = vpci
+ cfg_file.append(trex_cfg)
+
+ with open('/tmp/trex_cfg.yaml', 'w') as outfile:
+ outfile.write(yaml.safe_dump(cfg_file, default_flow_style=False))
+ self.connection.put('/tmp/trex_cfg.yaml', '/etc')
+
+ self._vpci_ascending = sorted(vpci)
+
+ @classmethod
+ def __setup_hugepages(cls, connection):
+ hugepages = \
+ connection.execute(
+ "awk '/Hugepagesize/ { print $2$3 }' < /proc/meminfo")[1]
+ hugepages = hugepages.rstrip()
+
+ memory_path = \
+ '/sys/kernel/mm/hugepages/hugepages-%s/nr_hugepages' % hugepages
+ connection.execute("awk -F: '{ print $1 }' < %s" % memory_path)
+
+ pages = 16384 if hugepages.rstrip() == "2048kB" else 16
+ connection.execute("echo %s > %s" % (pages, memory_path))
+
+ def setup_vnf_environment(self, connection):
+ ''' setup dpdk environment needed for vnf to run '''
+
+ self.__setup_hugepages(connection)
+ connection.execute("modprobe uio && modprobe igb_uio")
+
+ exit_status = connection.execute("lsmod | grep -i igb_uio")[0]
+ if exit_status == 0:
+ return
+
+ dpdk = os.path.join(self.bin_path, "dpdk-16.07")
+ dpdk_setup = \
+ provision_tool(self.connection,
+ os.path.join(self.bin_path, "nsb_setup.sh"))
+ status = connection.execute("ls {} >/dev/null 2>&1".format(dpdk))[0]
+ if status:
+ connection.execute("bash %s dpdk >/dev/null 2>&1" % dpdk_setup)
+
+ def scale(self, flavor=""):
+ ''' scale vnfbased on flavor input '''
+ super(TrexTrafficGen, self).scale(flavor)
+
+ def instantiate(self, scenario_cfg, context_cfg):
+ self._generate_trex_cfg(self.vnfd)
+ self.setup_vnf_environment(self.connection)
+
+ trex = os.path.join(self.bin_path, "trex")
+ err = \
+ self.connection.execute("ls {} >/dev/null 2>&1".format(trex))[0]
+ if err != 0:
+ LOG.info("Copying trex to destination...")
+ self.connection.put("/root/.bash_profile", "/root/.bash_profile")
+ self.connection.put(trex, trex, True)
+ ko_src = os.path.join(trex, "scripts/ko/src/")
+ self.connection.execute("cd %s && make && make install" % ko_src)
+
+ LOG.info("Starting TRex server...")
+ _tg_process = \
+ multiprocessing.Process(target=self._start_server)
+ _tg_process.start()
+ while True:
+ if not _tg_process.is_alive():
+ raise RuntimeError("Traffic Generator process died.")
+ LOG.info("Waiting for TG Server to start.. ")
+ time.sleep(1)
+ status = \
+ self.connection.execute("lsof -i:%s" % TREX_SYNC_PORT)[0]
+ if status == 0:
+ LOG.info("TG server is up and running.")
+ return _tg_process.exitcode
+
+ def listen_traffic(self, traffic_profile):
+ pass
+
+ def _get_logical_if_name(self, vpci):
+ ext_intf = self.vnfd["vdu"][0]["external-interface"]
+ for interface in range(len(self.vnfd["vdu"][0]["external-interface"])):
+ virtual_intf = ext_intf[interface]["virtual-interface"]
+ if virtual_intf["vpci"] == vpci:
+ return ext_intf[interface]["name"]
+
+ def run_traffic(self, traffic_profile):
+ self._traffic_process = \
+ multiprocessing.Process(target=self._traffic_runner,
+ args=(traffic_profile, self._queue,
+ self.client_started,
+ self._terminated))
+ self._traffic_process.start()
+ # Wait for traffic process to start
+ while self.client_started.value == 0:
+ time.sleep(1)
+
+ return self._traffic_process.is_alive()
+
+ def _start_server(self):
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ _server = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ _server.wait()
+
+ _server.execute("fuser -n tcp %s %s -k > /dev/null 2>&1" %
+ (TREX_SYNC_PORT, TREX_ASYNC_PORT))
+
+ trex_path = os.path.join(self.bin_path, "trex/scripts")
+ path = get_nsb_option("trex_path", trex_path)
+ trex_cmd = "cd " + path + "; sudo ./t-rex-64 -i > /dev/null 2>&1"
+
+ _server.execute(trex_cmd)
+
+ def _connect_client(self, client=None):
+ if client is None:
+ client = STLClient(username=self.vnfd["mgmt-interface"]["user"],
+ server=self.vnfd["mgmt-interface"]["ip"],
+ verbose_level=LoggerApi.VERBOSE_QUIET)
+ # try to connect with 5s intervals, 30s max
+ for idx in range(6):
+ try:
+ client.connect()
+ break
+ except STLError:
+ LOG.info("Unable to connect to Trex Server.. Attempt %s", idx)
+ time.sleep(5)
+ return client
+
+ def _traffic_runner(self, traffic_profile, queue,
+ client_started, terminated):
+ LOG.info("Starting TRex client...")
+
+ self.my_ports = [0, 1]
+ self.client = self._connect_client()
+ self.client.reset(ports=self.my_ports)
+
+ self.client.remove_all_streams(self.my_ports) # remove all streams
+
+ while not terminated.value:
+ traffic_profile.execute(self)
+ client_started.value = 1
+ last_res = self.client.get_stats(self.my_ports)
+ if not isinstance(last_res, dict): # added for mock unit test
+ terminated.value = 1
+ last_res = {}
+
+ samples = {}
+ for vpci_idx in range(len(self._vpci_ascending)):
+ name = \
+ self._get_logical_if_name(self._vpci_ascending[vpci_idx])
+ # fixme: VNFDs KPIs values needs to be mapped to TRex structure
+ xe_value = last_res.get(vpci_idx, {})
+ samples[name] = \
+ {"rx_throughput_fps": float(xe_value.get("rx_pps", 0.0)),
+ "tx_throughput_fps": float(xe_value.get("tx_pps", 0.0)),
+ "rx_throughput_mbps": float(xe_value.get("rx_bps", 0.0)),
+ "tx_throughput_mbps": float(xe_value.get("tx_bps", 0.0)),
+ "in_packets": xe_value.get("ipackets", 0),
+ "out_packets": xe_value.get("opackets", 0)}
+ queue.put(samples)
+
+ self.client.disconnect()
+ terminated.value = 0
+
+ def collect_kpi(self):
+ if not self._queue.empty():
+ self._result.update(self._queue.get())
+ LOG.debug("trex collect Kpis %s", self._result)
+ return self._result
+
+ def terminate(self):
+ self.connection.execute("fuser -n tcp %s %s -k > /dev/null 2>&1" %
+ (TREX_SYNC_PORT, TREX_ASYNC_PORT))
+ self.traffic_finished = True
+ if self._traffic_process:
+ self._traffic_process.terminate()
diff --git a/yardstick/network_services/vnf_generic/vnf/vpe_vnf.py b/yardstick/network_services/vnf_generic/vnf/vpe_vnf.py
new file mode 100644
index 000000000..8c766f01e
--- /dev/null
+++ b/yardstick/network_services/vnf_generic/vnf/vpe_vnf.py
@@ -0,0 +1,331 @@
+# Copyright (c) 2016-2017 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+""" vPE (Power Edge router) VNF model definitions based on IETS Spec """
+
+from __future__ import absolute_import
+from __future__ import print_function
+import tempfile
+import time
+import os
+import logging
+import re
+from multiprocessing import Queue
+import multiprocessing
+import ipaddress
+import six
+
+from yardstick import ssh
+from yardstick.network_services.vnf_generic.vnf.base import GenericVNF
+from yardstick.network_services.utils import provision_tool
+from yardstick.network_services.vnf_generic.vnf.base import QueueFileWrapper
+from yardstick.network_services.nfvi.resource import ResourceProfile
+
+LOG = logging.getLogger(__name__)
+VPE_PIPELINE_COMMAND = '{tool_path} -p 0x3 -f {cfg_file} -s {script}'
+CORES = ['0', '1', '2']
+WAIT_TIME = 20
+
+
+class VpeApproxVnf(GenericVNF):
+ """ This class handles vPE VNF model-driver definitions """
+
+ def __init__(self, vnfd):
+ super(VpeApproxVnf, self).__init__(vnfd)
+ self.socket = None
+ self.q_in = Queue()
+ self.q_out = Queue()
+ self.vnf_cfg = None
+ self._vnf_process = None
+ self.connection = None
+ self.resource = None
+
+ def _resource_collect_start(self):
+ self.resource.initiate_systemagent(self.bin_path)
+ self.resource.start()
+
+ def _resource_collect_stop(self):
+ self.resource.stop()
+
+ def _collect_resource_kpi(self):
+ result = {}
+
+ status = self.resource.check_if_sa_running("collectd")[0]
+ if status:
+ result = self.resource.amqp_collect_nfvi_kpi()
+
+ result = {"core": result}
+
+ return result
+
+ @classmethod
+ def __setup_hugepages(cls, connection):
+ hugepages = \
+ connection.execute(
+ "awk '/Hugepagesize/ { print $2$3 }' < /proc/meminfo")[1]
+ hugepages = hugepages.rstrip()
+
+ memory_path = \
+ '/sys/kernel/mm/hugepages/hugepages-%s/nr_hugepages' % hugepages
+ connection.execute("awk -F: '{ print $1 }' < %s" % memory_path)
+
+ pages = 16384 if hugepages.rstrip() == "2048kB" else 16
+ connection.execute("echo %s > %s" % (pages, memory_path))
+
+ def setup_vnf_environment(self, connection):
+ ''' setup dpdk environment needed for vnf to run '''
+
+ self.__setup_hugepages(connection)
+ connection.execute("modprobe uio && modprobe igb_uio")
+
+ exit_status = connection.execute("lsmod | grep -i igb_uio")[0]
+ if exit_status == 0:
+ return
+
+ dpdk = os.path.join(self.bin_path, "dpdk-16.07")
+ dpdk_setup = \
+ provision_tool(self.connection,
+ os.path.join(self.bin_path, "nsb_setup.sh"))
+ status = connection.execute("ls {} >/dev/null 2>&1".format(dpdk))[0]
+ if status:
+ connection.execute("bash %s dpdk >/dev/null 2>&1" % dpdk_setup)
+
+ def _get_cpu_sibling_list(self):
+ cpu_topo = []
+ for core in CORES:
+ sys_cmd = \
+ "/sys/devices/system/cpu/cpu%s/topology/thread_siblings_list" \
+ % core
+ cpuid = \
+ self.connection.execute("awk -F: '{ print $1 }' < %s" %
+ sys_cmd)[1]
+ cpu_topo += \
+ [(idx) if idx.isdigit() else idx for idx in cpuid.split(',')]
+
+ return [cpu.strip() for cpu in cpu_topo]
+
+ def scale(self, flavor=""):
+ ''' scale vnfbased on flavor input '''
+ super(VpeApproxVnf, self).scale(flavor)
+
+ def instantiate(self, scenario_cfg, context_cfg):
+ vnf_cfg = scenario_cfg['vnf_options']['vpe']['cfg']
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+
+ self.connection = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+
+ self.connection.wait()
+
+ self.setup_vnf_environment(self.connection)
+
+ cores = self._get_cpu_sibling_list()
+ self.resource = ResourceProfile(self.vnfd, cores)
+
+ self.connection.execute("pkill vPE_vnf")
+ dpdk_nic_bind = \
+ provision_tool(self.connection,
+ os.path.join(self.bin_path, "dpdk_nic_bind.py"))
+
+ interfaces = self.vnfd["vdu"][0]['external-interface']
+ self.socket = \
+ next((0 for v in interfaces
+ if v['virtual-interface']["vpci"][5] == "0"), 1)
+
+ bound_pci = [v['virtual-interface']["vpci"] for v in interfaces]
+ for vpci in bound_pci:
+ self.connection.execute(
+ "%s --force -b igb_uio %s" % (dpdk_nic_bind, vpci))
+ queue_wrapper = \
+ QueueFileWrapper(self.q_in, self.q_out, "pipeline>")
+ self._vnf_process = multiprocessing.Process(target=self._run_vpe,
+ args=(queue_wrapper,
+ vnf_cfg,))
+ self._vnf_process.start()
+ buf = []
+ time.sleep(WAIT_TIME) # Give some time for config to load
+ while True:
+ message = ''
+ while self.q_out.qsize() > 0:
+ buf.append(self.q_out.get())
+ message = ''.join(buf)
+ if "pipeline>" in message:
+ LOG.info("VPE VNF is up and running.")
+ queue_wrapper.clear()
+ self._resource_collect_start()
+ return self._vnf_process.exitcode
+ if "PANIC" in message:
+ raise RuntimeError("Error starting vPE VNF.")
+
+ LOG.info("Waiting for VNF to start.. ")
+ time.sleep(3)
+ if not self._vnf_process.is_alive():
+ raise RuntimeError("vPE VNF process died.")
+
+ def _get_ports_gateway(self, name):
+ if 'routing_table' in self.vnfd['vdu'][0]:
+ routing_table = self.vnfd['vdu'][0]['routing_table']
+
+ for route in routing_table:
+ if name == route['if']:
+ return route['gateway']
+
+ def terminate(self):
+ self.execute_command("quit")
+ if self._vnf_process:
+ self._vnf_process.terminate()
+
+ def _run_vpe(self, filewrapper, vnf_cfg):
+ mgmt_interface = self.vnfd["mgmt-interface"]
+ ssh_port = mgmt_interface.get("ssh_port", ssh.DEFAULT_PORT)
+ self.connection = ssh.SSH(mgmt_interface["user"], mgmt_interface["ip"],
+ password=mgmt_interface["password"],
+ port=ssh_port)
+ self.connection.wait()
+ interfaces = self.vnfd["vdu"][0]['external-interface']
+ port0_ip = ipaddress.ip_interface(six.text_type(
+ "%s/%s" % (interfaces[0]["virtual-interface"]["local_ip"],
+ interfaces[0]["virtual-interface"]["netmask"])))
+ port1_ip = ipaddress.ip_interface(six.text_type(
+ "%s/%s" % (interfaces[1]["virtual-interface"]["local_ip"],
+ interfaces[1]["virtual-interface"]["netmask"])))
+ dst_port0_ip = ipaddress.ip_interface(
+ u"%s/%s" % (interfaces[0]["virtual-interface"]["dst_ip"],
+ interfaces[0]["virtual-interface"]["netmask"]))
+ dst_port1_ip = ipaddress.ip_interface(
+ u"%s/%s" % (interfaces[1]["virtual-interface"]["dst_ip"],
+ interfaces[1]["virtual-interface"]["netmask"]))
+
+ vpe_vars = {"port0_local_ip": port0_ip.ip.exploded,
+ "port0_dst_ip": dst_port0_ip.ip.exploded,
+ "port0_local_ip_hex":
+ self._ip_to_hex(port0_ip.ip.exploded),
+ "port0_prefixlen": port0_ip.network.prefixlen,
+ "port0_netmask": port0_ip.network.netmask.exploded,
+ "port0_netmask_hex":
+ self._ip_to_hex(port0_ip.network.netmask.exploded),
+ "port0_local_mac":
+ interfaces[0]["virtual-interface"]["local_mac"],
+ "port0_dst_mac":
+ interfaces[0]["virtual-interface"]["dst_mac"],
+ "port0_gateway":
+ self._get_ports_gateway(interfaces[0]["name"]),
+ "port0_local_network":
+ port0_ip.network.network_address.exploded,
+ "port0_prefix": port0_ip.network.prefixlen,
+ "port1_local_ip": port1_ip.ip.exploded,
+ "port1_dst_ip": dst_port1_ip.ip.exploded,
+ "port1_local_ip_hex":
+ self._ip_to_hex(port1_ip.ip.exploded),
+ "port1_prefixlen": port1_ip.network.prefixlen,
+ "port1_netmask": port1_ip.network.netmask.exploded,
+ "port1_netmask_hex":
+ self._ip_to_hex(port1_ip.network.netmask.exploded),
+ "port1_local_mac":
+ interfaces[1]["virtual-interface"]["local_mac"],
+ "port1_dst_mac":
+ interfaces[1]["virtual-interface"]["dst_mac"],
+ "port1_gateway":
+ self._get_ports_gateway(interfaces[1]["name"]),
+ "port1_local_network":
+ port1_ip.network.network_address.exploded,
+ "port1_prefix": port1_ip.network.prefixlen,
+ "port0_local_ip6": self._get_port0localip6(),
+ "port1_local_ip6": self._get_port1localip6(),
+ "port0_prefixlen6": self._get_port0prefixlen6(),
+ "port1_prefixlen6": self._get_port1prefixlen6(),
+ "port0_gateway6": self._get_port0gateway6(),
+ "port1_gateway6": self._get_port1gateway6(),
+ "port0_dst_ip_hex6": self._get_port0localip6(),
+ "port1_dst_ip_hex6": self._get_port1localip6(),
+ "port0_dst_netmask_hex6": self._get_port0prefixlen6(),
+ "port1_dst_netmask_hex6": self._get_port1prefixlen6(),
+ "bin_path": self.bin_path,
+ "socket": self.socket}
+
+ for cfg in os.listdir(vnf_cfg):
+ vpe_config = ""
+ with open(os.path.join(vnf_cfg, cfg), 'r') as vpe_cfg:
+ vpe_config = vpe_cfg.read()
+
+ self._provide_config_file(cfg, vpe_config, vpe_vars)
+
+ LOG.info("Provision and start the vPE")
+ tool_path = provision_tool(self.connection,
+ os.path.join(self.bin_path, "vPE_vnf"))
+ cmd = VPE_PIPELINE_COMMAND.format(cfg_file="/tmp/vpe_config",
+ script="/tmp/vpe_script",
+ tool_path=tool_path)
+ self.connection.run(cmd, stdin=filewrapper, stdout=filewrapper,
+ keep_stdin_open=True, pty=True)
+
+ def _provide_config_file(self, prefix, template, args):
+ cfg, cfg_content = tempfile.mkstemp()
+ cfg = os.fdopen(cfg, "w+")
+ cfg.write(template.format(**args))
+ cfg.close()
+ cfg_file = "/tmp/%s" % prefix
+ self.connection.put(cfg_content, cfg_file)
+ return cfg_file
+
+ def execute_command(self, cmd):
+ ''' send cmd to vnf process '''
+ LOG.info("VPE command: %s", cmd)
+ output = []
+ if self.q_in:
+ self.q_in.put(cmd + "\r\n")
+ time.sleep(3)
+ while self.q_out.qsize() > 0:
+ output.append(self.q_out.get())
+ return "".join(output)
+
+ def collect_kpi(self):
+ result = self.get_stats_vpe()
+ collect_stats = self._collect_resource_kpi()
+ result["collect_stats"] = collect_stats
+ LOG.debug("vPE collet Kpis: %s", result)
+ return result
+
+ def get_stats_vpe(self):
+ ''' get vpe statistics '''
+ result = {'pkt_in_up_stream': 0, 'pkt_drop_up_stream': 0,
+ 'pkt_in_down_stream': 0, 'pkt_drop_down_stream': 0}
+ up_stat_commands = ['p 5 stats port in 0', 'p 5 stats port out 0',
+ 'p 5 stats port out 1']
+ down_stat_commands = ['p 9 stats port in 0', 'p 9 stats port out 0']
+ pattern = \
+ "Pkts in:\\s(\\d+)\\r\\n\\tPkts dropped by " \
+ "AH:\\s(\\d+)\\r\\n\\tPkts dropped by other:\\s(\\d+)"
+
+ for cmd in up_stat_commands:
+ stats = self.execute_command(cmd)
+ match = re.search(pattern, stats, re.MULTILINE)
+ if match:
+ result["pkt_in_up_stream"] = \
+ result.get("pkt_in_up_stream", 0) + int(match.group(1))
+ result["pkt_drop_up_stream"] = \
+ result.get("pkt_drop_up_stream", 0) + \
+ int(match.group(2)) + int(match.group(3))
+
+ for cmd in down_stat_commands:
+ stats = self.execute_command(cmd)
+ match = re.search(pattern, stats, re.MULTILINE)
+ if match:
+ result["pkt_in_down_stream"] = \
+ result.get("pkt_in_down_stream", 0) + int(match.group(1))
+ result["pkt_drop_down_stream"] = \
+ result.get("pkt_drop_down_stream", 0) + \
+ int(match.group(2)) + int(match.group(3))
+ return result