This change adds license to all .rst files under userguide. It also combines all configguide files into user guide. New reference.rst with list of links. Updated glossary, removed separate directories for apexlake and yardstick framework. Change-Id: I6532ed073905b0fa85a17e759ea7dc3c24acb91f Signed-off-by: Ana C <ana.cunha@ericsson.com> (cherry picked from commit 702eebbf78b29fb9046436dd71575b4f210f4731)
Diffstat (limited to 'docs/userguide/opnfv_yardstick_tc005.rst')
-rw-r--r--docs/userguide/opnfv_yardstick_tc005.rst77
1 files changed, 77 insertions, 0 deletions
diff --git a/docs/userguide/opnfv_yardstick_tc005.rst b/docs/userguide/opnfv_yardstick_tc005.rst
new file mode 100644
index 000000000..a181aa9f7
--- /dev/null
+++ b/docs/userguide/opnfv_yardstick_tc005.rst
@@ -0,0 +1,77 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International
+.. License.
+.. http://creativecommons.org/licenses/by/4.0
+.. (c) OPNFV, Huawei Technologies Co.,Ltd and others.
+
+*************************************
+Yardstick Test Case Description TC005
+*************************************
+
+.. _fio: http://www.bluestop.org/fio/HOWTO.txt
+
++-----------------------------------------------------------------------------+
+|Storage Performance |
+| |
++--------------+--------------------------------------------------------------+
+|test case id | OPNFV_YARDSTICK_TC005_Storage Performance |
+| | |
++--------------+--------------------------------------------------------------+
+|metric | IOPS, throughput and latency |
+| | |
++--------------+--------------------------------------------------------------+
+|test purpose | To evaluate the IaaS storage performance with regards to |
+| | IOPS, throughput and latency. |
+| | The purpose is also to be able to spot trends. Test results, |
+| | graphs and similar shall be stored for comparison reasons |
+| | and product evolution understanding between different OPNFV |
+| | versions and/or configurations. |
+| | |
++--------------+--------------------------------------------------------------+
+|configuration | file: opnfv_yardstick_tc005.yaml |
+| | |
+| | IO types: read, write, randwrite, randread, rw |
+| | IO block size: 4KB, 64KB, 1024KB, where each |
+| | runs for 30 seconds(10 for ramp time, 20 for runtime). |
+| | |
+| | For SLA minimum read/write iops is set to 100, minimum |
+| | read/write throughput is set to 400 KB/s, and maximum |
+| | read/write latency is set to 20000 usec. |
+| | |
++--------------+--------------------------------------------------------------+
+|test tool | fio |
+| | |
+| | (fio is not always part of a Linux distribution, hence it |
+| | needs to be installed. As an example see the |
+| | /yardstick/tools/ directory for how to generate a Linux |
+| | image with fio included.) |
+| | |
++--------------+--------------------------------------------------------------+
+|references | fio_ |
+| | |
+| | ETSI-NFV-TST001 |
+| | |
++--------------+--------------------------------------------------------------+
+|applicability | Test can be configured with different read/write types, IO |
+| | block size, IO depth, ramp time (runtime required for stable |
+| | results) and test duration. Default values exist. |
+| | |
++--------------+--------------------------------------------------------------+
+|pre-test | The test case image needs to be installed into Glance |
+|conditions | with fio included in it. |
+| | |
+| | No POD specific requirements have been identified. |
+| | |
++--------------+--------------------------------------------------------------+
+|test sequence | description and expected result |
+| | |
++--------------+--------------------------------------------------------------+
+|step 1 | The host is installed and fio is invoked and logs are |
+| | produced and stored. |
+| | |
+| | Result: Logs are stored. |
+| | |
++--------------+--------------------------------------------------------------+
+|test verdict | Fails only if SLA is not passed, or if there is a test case |
+| | execution problem. |
+| | |
++--------------+--------------------------------------------------------------+