diff options
author | Emma Foley <emma.l.foley@intel.com> | 2018-10-03 13:54:09 +0100 |
---|---|---|
committer | Emma Foley <emma.l.foley@intel.com> | 2018-10-30 19:27:39 +0000 |
commit | 28e64c520fc2a52c1d3eb736f88ad4608b87c142 (patch) | |
tree | 123c384236fbd86a28e376957097417e2a7f1605 /docs/testing | |
parent | 5456b070a8e05cd49d5626b002f6eeee71bcd67d (diff) |
[docs] Fix docs {un,}indent warnings in Testcase definitions
Mostly, the issues were with un/indentation.
This has been fixed, and `tox -e docs` now issues less warnings.
JIRA: YARDSTICK-1416
Change-Id: Ie58a8dba42e9868357e1dce414cb1a01af8ad1f4
Signed-off-by: Emma Foley <emma.l.foley@intel.com>
Diffstat (limited to 'docs/testing')
16 files changed, 148 insertions, 106 deletions
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc010.rst b/docs/testing/user/userguide/opnfv_yardstick_tc010.rst index 202307de6..19cc80e30 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc010.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc010.rst @@ -34,6 +34,7 @@ Yardstick Test Case Description TC010 | | | | | Lmbench is a suite of operating system microbenchmarks. This | | | test uses lat_mem_rd tool from that suite including: | +| | | | | * Context switching | | | * Networking: connection establishment, pipe, TCP, UDP, and | | | RPC hot potato | @@ -55,7 +56,7 @@ Yardstick Test Case Description TC010 | | The benchmark runs as two nested loops. The outer loop is | | | the stride size. The inner loop is the array size. For each | | | array size, the benchmark creates a ring of pointers that | -| | point backward one stride.Traversing the array is done by: | +| | point backward one stride. Traversing the array is done by:: | | | | | | p = (char **)*p; | | | | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc011.rst b/docs/testing/user/userguide/opnfv_yardstick_tc011.rst index 48bdef497..cbb1db91f 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc011.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc011.rst @@ -60,14 +60,14 @@ Yardstick Test Case Description TC011 | | | | | * options: | | | protocol: udp # The protocol used by iperf3 tools | -| | bandwidth: 20m # It will send the given number of packets | -| | without pausing | +| | # Send the given number of packets without pausing: | +| | bandwidth: 20m | | | * runner: | | | duration: 30 # Total test duration 30 seconds. | | | | | | * SLA (optional): | | | jitter: 10 (ms) # The maximum amount of jitter that is | -| | accepted. | +| | accepted. | | | | +--------------+--------------------------------------------------------------+ |applicability | Test can be configured with different: | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc012.rst b/docs/testing/user/userguide/opnfv_yardstick_tc012.rst index b56e829f5..2502f5d94 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc012.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc012.rst @@ -34,6 +34,7 @@ Yardstick Test Case Description TC012 | | | | | LMbench is a suite of operating system microbenchmarks. | | | This test uses bw_mem tool from that suite including: | +| | | | | * Cached file read | | | * Memory copy (bcopy) | | | * Memory read | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc019.rst b/docs/testing/user/userguide/opnfv_yardstick_tc019.rst index 8d79e011a..d27b201c5 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc019.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc019.rst @@ -43,20 +43,24 @@ Yardstick Test Case Description TC019 | | | +--------------+--------------------------------------------------------------+ |monitors | In this test case, two kinds of monitor are needed: | +| | | | | 1. the "openstack-cmd" monitor constantly request a specific | | | Openstack command, which needs two parameters: | -| | 1) monitor_type: which is used for finding the monitor class | -| | and related scritps. It should be always set to | -| | "openstack-cmd" for this monitor. | -| | 2) command_name: which is the command name used for request | +| | | +| | 1. monitor_type: which is used for finding the monitor | +| | class and related scritps. It should be always set to | +| | "openstack-cmd" for this monitor. | +| | 2. command_name: which is the command name used for | +| | request | | | | | | 2. the "process" monitor check whether a process is running | | | on a specific node, which needs three parameters: | -| | 1) monitor_type: which used for finding the monitor class | -| | and related scritps. It should be always set to "process" | -| | for this monitor. | -| | 2) process_name: which is the process name for monitor | -| | 3) host: which is the name of the node runing the process | +| | | +| | 1. monitor_type: which used for finding the monitor class | +| | and related scritps. It should be always set to | +| | "process" for this monitor. | +| | 2. process_name: which is the process name for monitor | +| | 3. host: which is the name of the node runing the process | | | | | | e.g. | | | monitor1: | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc025.rst b/docs/testing/user/userguide/opnfv_yardstick_tc025.rst index 0e2e9a5f8..f3f9ea6bf 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc025.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc025.rst @@ -39,12 +39,15 @@ Yardstick Test Case Description TC025 | | | +--------------+--------------------------------------------------------------+ |monitors | In this test case, one kind of monitor are needed: | +| | | | | 1. the "openstack-cmd" monitor constantly request a specific | | | Openstack command, which needs two parameters | -| | 1) monitor_type: which is used for finding the monitor class | -| | and related scritps. It should be always set to | -| | "openstack-cmd" for this monitor. | -| | 2) command_name: which is the command name used for request | +| | | +| | 1) monitor_type: which is used for finding the monitor | +| | class and related scripts. It should be always set to | +| | "openstack-cmd" for this monitor. | +| | 2) command_name: which is the command name used for | +| | request | | | | | | There are four instance of the "openstack-cmd" monitor: | | | monitor1: | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst index 82a491b72..7d01cb99a 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst @@ -35,18 +35,18 @@ Yardstick Test Case Description TC050 | | 3) interface: the network interface to be turned off. | | | | | | The interface to be closed by the attacker can be set by the | -| | variable of "{{ interface_name }}" | +| | variable of "{{ interface_name }}":: | | | | -| | attackers: | -| | - | -| | fault_type: "general-attacker" | -| | host: {{ attack_host }} | -| | key: "close-br-public" | -| | attack_key: "close-interface" | -| | action_parameter: | -| | interface: {{ interface_name }} | -| | rollback_parameter: | -| | interface: {{ interface_name }} | +| | attackers: | +| | - | +| | fault_type: "general-attacker" | +| | host: {{ attack_host }} | +| | key: "close-br-public" | +| | attack_key: "close-interface" | +| | action_parameter: | +| | interface: {{ interface_name }} | +| | rollback_parameter: | +| | interface: {{ interface_name }} | | | | +--------------+--------------------------------------------------------------+ |monitors | In this test case, the monitor named "openstack-cmd" is | @@ -56,19 +56,20 @@ Yardstick Test Case Description TC050 | | "openstack-cmd" for this monitor. | | | 2) command_name: which is the command name used for request | | | | -| | There are four instance of the "openstack-cmd" monitor: | -| | monitor1: | -| | - monitor_type: "openstack-cmd" | -| | - command_name: "nova image-list" | -| | monitor2: | -| | - monitor_type: "openstack-cmd" | -| | - command_name: "neutron router-list" | -| | monitor3: | -| | - monitor_type: "openstack-cmd" | -| | - command_name: "heat stack-list" | -| | monitor4: | -| | - monitor_type: "openstack-cmd" | -| | - command_name: "cinder list" | +| | There are four instance of the "openstack-cmd" monitor:: | +| | | +| | monitor1: | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "nova image-list" | +| | monitor2: | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "neutron router-list" | +| | monitor3: | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "heat stack-list" | +| | monitor4: | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "cinder list" | +--------------+--------------------------------------------------------------+ |metrics | In this test case, there is one metric: | | | 1)service_outage_time: which indicates the maximum outage | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc052.rst b/docs/testing/user/userguide/opnfv_yardstick_tc052.rst index 9514b6819..7f2be6e7d 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc052.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc052.rst @@ -65,15 +65,16 @@ Yardstick Test Case Description TC052 | | | | | In this case, the "operation" adds a flavor and the "result | | | checker" checks whether ths flavor is created. Their | -| | parameters show as follows: | -| | operation: | -| | -operation_type: "nova-create-flavor" | -| | -action_parameter: | -| | flavorconfig: "test-001 test-001 100 1 1" | -| | result checker: | -| | -checker_type: "check-flavor" | -| | -expectedValue: "test-001" | -| | -condition: "in" | +| | parameters show as follows:: | +| | | +| | operation: | +| | -operation_type: "nova-create-flavor" | +| | -action_parameter: | +| | flavorconfig: "test-001 test-001 100 1 1" | +| | result checker: | +| | -checker_type: "check-flavor" | +| | -expectedValue: "test-001" | +| | -condition: "in" | +--------------+--------------------------------------------------------------+ |metrics | In this test case, there is one metric: | | | 1)service_outage_time: which indicates the maximum outage | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc055.rst b/docs/testing/user/userguide/opnfv_yardstick_tc055.rst index c861ca90c..25703d3fb 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc055.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc055.rst @@ -7,7 +7,7 @@ Yardstick Test Case Description TC055 ************************************* -.. _/proc/cpuinfo: http://www.linfo.org/proc_cpuinfo.html +.. _`/proc/cpuinfo`: http://www.linfo.org/proc_cpuinfo.html +-----------------------------------------------------------------------------+ |Compute Capacity | @@ -41,7 +41,7 @@ Yardstick Test Case Description TC055 | | capacity output. | | | | +--------------+--------------------------------------------------------------+ -|references | /proc/cpuinfo_ | +|references | `/proc/cpuinfo`_ | | | | | | ETSI-NFV-TST001 | | | | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc057.rst b/docs/testing/user/userguide/opnfv_yardstick_tc057.rst index 1bb43c9e7..245a58e08 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc057.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc057.rst @@ -49,12 +49,15 @@ Yardstick Test Case Description TC057 | | -host: node1 | +--------------+--------------------------------------------------------------+ |monitors | In this test case, a kind of monitor is needed: | +| | | | | 1. the "openstack-cmd" monitor constantly request a specific | | | Openstack command, which needs two parameters: | -| | 1) monitor_type: which is used for finding the monitor class | -| | and related scripts. It should be always set to | -| | "openstack-cmd" for this monitor. | -| | 2) command_name: which is the command name used for request | +| | | +| | 1. monitor_type: which is used for finding the monitor | +| | class and related scripts. It should be always set to | +| | "openstack-cmd" for this monitor. | +| | 2. command_name: which is the command name used for | +| | request | | | | | | In this case, the command_name of monitor1 should be | | | services that are managed by the cluster manager. | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc063.rst b/docs/testing/user/userguide/opnfv_yardstick_tc063.rst index a77653aa5..7b8ee06c7 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc063.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc063.rst @@ -58,6 +58,7 @@ Yardstick Test Case Description TC063 | | * count: 15 - how many times to stat disk utilization | | | type: int | | | unit: na | +| | | | | There are default values for each above-mentioned option. | | | Run in background with other test cases. | | | | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc069.rst b/docs/testing/user/userguide/opnfv_yardstick_tc069.rst index af0e64fbf..2d61438a8 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc069.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc069.rst @@ -41,7 +41,8 @@ Yardstick Test Case Description TC069 | | * SLA (optional): 7000 (MBps) min_bandwidth: The minimum | | | amount of memory bandwidth that is accepted. | | | * type_id: 1 - runs a specified benchmark | -| | (by an ID number): | +| | (by an ID number):: | +| | | | | 1 -- INTmark [writing] 4 -- FLOATmark [writing] | | | 2 -- INTmark [reading] 5 -- FLOATmark [reading] | | | 3 -- INTmem 6 -- FLOATmem | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc074.rst b/docs/testing/user/userguide/opnfv_yardstick_tc074.rst index d6beeaff9..8d025eecf 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc074.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc074.rst @@ -91,12 +91,15 @@ Yardstick Test Case Description TC074 | | * workload=[workload module] | | | If not specified, the default is to run all workloads. The | | | workload types are: | +| | | | | - rs: 100% Read, sequential data | | | - ws: 100% Write, sequential data | | | - rr: 100% Read, random access | | | - wr: 100% Write, random access | | | - rw: 70% Read / 30% write, random access | +| | | | | measurements. | +| | | | | * workloads={json maps} | | | This parameter supercedes the workload and calls the V2.0 | | | API in StorPerf. It allows for greater control of the | @@ -131,11 +134,13 @@ Yardstick Test Case Description TC074 | | | | | Storperf is required to be installed in the environment. | | | There are two possible methods for Storperf installation: | -| | Run container on Jump Host | -| | Run container in a VM | +| | | +| | - Run container on Jump Host | +| | - Run container in a VM | | | | | | Running StorPerf on Jump Host | | | Requirements: | +| | | | | - Docker must be installed | | | - Jump Host must have access to the OpenStack Controller | | | API | @@ -146,6 +151,7 @@ Yardstick Test Case Description TC074 | | | | | Running StorPerf in a VM | | | Requirements: | +| | | | | - VM has docker installed | | | - VM has OpenStack Controller credentials and can | | | communicate with the Controller API | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc084.rst b/docs/testing/user/userguide/opnfv_yardstick_tc084.rst index 2e7b28e25..b3d44c4bf 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc084.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc084.rst @@ -92,18 +92,19 @@ Yardstick Test Case Description TC084 +--------------+--------------------------------------------------------------+ |pre-test | To run and install SPEC CPU 2006, the following are | |conditions | required: | -| | * For SPECint 2006: Both C99 and C++98 compilers are | -| | installed in VM images; | -| | * For SPECfp 2006: All three of C99, C++98 and Fortran-95 | -| | compilers installed in VM images; | -| | * At least 4GB of disk space availabile on VM. | -| | | -| | gcc 4.8.* and g++ 4.8.* version have been tested in Ubuntu | -| | 14.04, Ubuntu 16.04 and Redhat Enterprise Linux 7.4 image. | -| | Higher gcc and g++ version may cause compiling error. | -| | | -| | For more SPEC CPU 2006 dependencies please visit | -| | (https://www.spec.org/cpu2006/Docs/techsupport.html) | +| | | +| | * For SPECint 2006: Both C99 and C++98 compilers are | +| | installed in VM images; | +| | * For SPECfp 2006: All three of C99, C++98 and Fortran-95 | +| | compilers installed in VM images; | +| | * At least 4GB of disk space availabile on VM. | +| | | +| | gcc 4.8.* and g++ 4.8.* version have been tested in Ubuntu | +| | 14.04, Ubuntu 16.04 and Redhat Enterprise Linux 7.4 image. | +| | Higher gcc and g++ version may cause compiling error. | +| | | +| | For more SPEC CPU 2006 dependencies please visit | +| | (https://www.spec.org/cpu2006/Docs/techsupport.html) | | | | +--------------+--------------------------------------------------------------+ |test sequence | description and expected result | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst index d3aed6b5b..c11252606 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst @@ -10,7 +10,7 @@ Yardstick Test Case Description TC087 +-----------------------------------------------------------------------------+ |SDN Controller resilience in non-HA configuration | | | -+==============+==============================================================+ ++--------------+--------------------------------------------------------------+ |test case id | OPNFV_YARDSTICK_TC087: SDN controller resilience in | | | non-HA configuration | | | | @@ -41,6 +41,7 @@ Yardstick Test Case Description TC087 +--------------+--------------------------------------------------------------+ |attackers | In this test case, an attacker called “kill-process” is | | | needed. This attacker includes three parameters: | +| | | | | 1. fault_type: which is used for finding the attacker's | | | scripts. It should be set to 'kill-process' in this test | | | | @@ -58,6 +59,7 @@ Yardstick Test Case Description TC087 |monitors | This test case utilizes two monitors of type "ip-status" | | | and one monitor of type "process" to track the following | | | conditions: | +| | | | | 1. "ping_same_network_l2": monitor ICMP traffic between | | | VMs in the same Neutron network | | | | @@ -74,11 +76,13 @@ Yardstick Test Case Description TC087 | | | +--------------+--------------------------------------------------------------+ |operations | In this test case, the following operations are needed: | +| | | | | 1. "nova-create-instance-in_network": create a VM instance | | | in one of the existing Neutron network. | | | | +--------------+--------------------------------------------------------------+ |metrics | In this test case, there are two metrics: | +| | | | | 1. process_recover_time: which indicates the maximun | | | time (seconds) from the process being killed to | | | recovered | @@ -95,7 +99,9 @@ Yardstick Test Case Description TC087 | | | +--------------+--------------------------------------------------------------+ |configuration | This test case needs two configuration files: | +| | | | | 1. test case file: opnfv_yardstick_tc087.yaml | +| | | | | - Attackers: see above “attackers” discription | | | - waiting_time: which is the time (seconds) from the | | | process being killed to stoping monitors the monitors | @@ -126,7 +132,7 @@ Yardstick Test Case Description TC087 | | Neutron network. | | | | | | 2. Check connectivity from one VM to an external host on | -| | the Internet to verify SNAT functionality. +| | the Internet to verify SNAT functionality. | | | | | | Result: The monitor info will be collected. | | | | @@ -171,11 +177,14 @@ Yardstick Test Case Description TC087 |test verdict | This test fails if the SLAs are not met or if there is a | | | test case execution problem. The SLAs are define as follows | | | for this test: | +| | | | | * SDN Controller recovery | +| | | | | * process_recover_time <= 30 sec | | | | | | * no impact on data plane connectivity during SDN | | | controller failure and recovery. | +| | | | | * packet_drop == 0 | | | | +--------------+--------------------------------------------------------------+ diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc092.rst b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst index 895074a85..9c833fa23 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc092.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc092.rst @@ -43,6 +43,7 @@ Yardstick Test Case Description TC092 +--------------+--------------------------------------------------------------+ |attackers | In this test case, an attacker called “kill-process” is | | | needed. This attacker includes three parameters: | +| | | | | 1. ``fault_type``: which is used for finding the attacker's | | | scripts. It should be set to 'kill-process' in this test | | | | @@ -92,17 +93,20 @@ Yardstick Test Case Description TC092 | | | +--------------+--------------------------------------------------------------+ |configuration | This test case needs two configuration files: | -| | 1. test case file: opnfv_yardstick_tc092.yaml | -| | - Attackers: see above “attackers” discription | -| | - Monitors: see above “monitors” discription | -| | - waiting_time: which is the time (seconds) from the | -| | process being killed to stoping monitors the | -| | monitors | -| | - SLA: see above “metrics” discription | +| | 1. test case file: opnfv_yardstick_tc092.yaml | +| | | +| | - Attackers: see above “attackers” discription | +| | - Monitors: see above “monitors” discription | +| | | +| | - waiting_time: which is the time (seconds) from the | +| | process being killed to stoping monitors the | +| | monitors | | | | -| | 2. POD file: pod.yaml The POD configuration should record | -| | on pod.yaml first. the “host” item in this test case | -| | will use the node name in the pod.yaml. | +| | - SLA: see above “metrics” discription | +| | | +| | 2. POD file: pod.yaml The POD configuration should record | +| | on pod.yaml first. the “host” item in this test case | +| | will use the node name in the pod.yaml. | | | | +--------------+--------------------------------------------------------------+ |test sequence | Description and expected result | @@ -168,11 +172,12 @@ Yardstick Test Case Description TC092 | | | +--------------+--------------------------------------------------------------+ |step 8 | Start IP connectivity monitors for the new VM: | -| | 1. Check the L2 connectivity from the existing VMs to the | -| | new VM in the Neutron network. | | | | -| | 2. Check connectivity from one VM to an external host on | -| | the Internet to verify SNAT functionality. | +| | 1. Check the L2 connectivity from the existing VMs to the | +| | new VM in the Neutron network. | +| | | +| | 2. Check connectivity from one VM to an external host on | +| | the Internet to verify SNAT functionality. | | | | | | Result: The monitor info will be collected. | | | | diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst index 31fa5d3d3..4e22e8bf3 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst @@ -43,14 +43,15 @@ Yardstick Test Case Description TC093 +--------------+--------------------------------------------------------------+ |attackers | In this test case, two attackers called “kill-process” are | | | needed. These attackers include three parameters: | -| | 1. fault_type: which is used for finding the attacker's | -| | scripts. It should be set to 'kill-process' in this test | | | | -| | 2. process_name: should be set to the name of the Vswitch | -| | process | +| | 1. fault_type: which is used for finding the attacker's | +| | scripts. It should be set to 'kill-process' in this test | | | | -| | 3. host: which is the name of the compute node where the | -| | Vswitch process is running | +| | 2. process_name: should be set to the name of the Vswitch | +| | process | +| | | +| | 3. host: which is the name of the compute node where the | +| | Vswitch process is running | | | | | | e.g. -fault_type: "kill-process" | | | -process_name: "openvswitch" | @@ -60,16 +61,17 @@ Yardstick Test Case Description TC093 |monitors | This test case utilizes two monitors of type "ip-status" | | | and one monitor of type "process" to track the following | | | conditions: | -| | 1. "ping_same_network_l2": monitor ICMP traffic between | -| | VMs in the same Neutron network | | | | -| | 2. "ping_external_snat": monitor ICMP traffic from VMs to | -| | an external host on the Internet to verify SNAT | -| | functionality. | +| | 1. "ping_same_network_l2": monitor ICMP traffic between | +| | VMs in the same Neutron network | +| | | +| | 2. "ping_external_snat": monitor ICMP traffic from VMs to | +| | an external host on the Internet to verify SNAT | +| | functionality. | | | | -| | 3. "Vswitch process monitor": a monitor checking the | -| | state of the specified Vswitch process. It measures | -| | the recovery time of the given process. | +| | 3. "Vswitch process monitor": a monitor checking the | +| | state of the specified Vswitch process. It measures | +| | the recovery time of the given process. | | | | | | Monitors of type "ip-status" use the "ping" utility to | | | verify reachability of a given target IP. | @@ -99,6 +101,7 @@ Yardstick Test Case Description TC093 +--------------+--------------------------------------------------------------+ |configuration | This test case needs two configuration files: | | | 1. test case file: opnfv_yardstick_tc093.yaml | +| | | | | - Attackers: see above “attackers” description | | | - monitor_time: which is the time (seconds) from | | | starting to stoping the monitors | @@ -173,12 +176,14 @@ Yardstick Test Case Description TC093 |test verdict | This test fails if the SLAs are not met or if there is a | | | test case execution problem. The SLAs are define as follows | | | for this test: | -| | * SDN Vswitch recovery | -| | * process_recover_time <= 30 sec | +| | * SDN Vswitch recovery | +| | | +| | * process_recover_time <= 30 sec | +| | | +| | * no impact on data plane connectivity during SDN | +| | Vswitch failure and recovery. | | | | -| | * no impact on data plane connectivity during SDN | -| | Vswitch failure and recovery. | -| | * packet_drop == 0 | +| | * packet_drop == 0 | | | | +--------------+--------------------------------------------------------------+ |