diff options
author | Rex Lee <limingjiang@huawei.com> | 2018-11-05 09:16:57 +0000 |
---|---|---|
committer | Gerrit Code Review <gerrit@opnfv.org> | 2018-11-05 09:16:57 +0000 |
commit | 3418d769a4bef9ea351e765fa00ad23986738e76 (patch) | |
tree | a47a5fa0dfabe30c4ee698072b40fc3f976700d3 /docs/testing/user/userguide/opnfv_yardstick_tc087.rst | |
parent | abdfd5465473b10670a843dfabfc9f10ad2f6a96 (diff) | |
parent | 28e64c520fc2a52c1d3eb736f88ad4608b87c142 (diff) |
Merge "[docs] Fix docs {un,}indent warnings in Testcase definitions"
Diffstat (limited to 'docs/testing/user/userguide/opnfv_yardstick_tc087.rst')
-rw-r--r-- | docs/testing/user/userguide/opnfv_yardstick_tc087.rst | 13 |
1 files changed, 11 insertions, 2 deletions
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst index d3aed6b5b..c11252606 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst @@ -10,7 +10,7 @@ Yardstick Test Case Description TC087 +-----------------------------------------------------------------------------+ |SDN Controller resilience in non-HA configuration | | | -+==============+==============================================================+ ++--------------+--------------------------------------------------------------+ |test case id | OPNFV_YARDSTICK_TC087: SDN controller resilience in | | | non-HA configuration | | | | @@ -41,6 +41,7 @@ Yardstick Test Case Description TC087 +--------------+--------------------------------------------------------------+ |attackers | In this test case, an attacker called “kill-process” is | | | needed. This attacker includes three parameters: | +| | | | | 1. fault_type: which is used for finding the attacker's | | | scripts. It should be set to 'kill-process' in this test | | | | @@ -58,6 +59,7 @@ Yardstick Test Case Description TC087 |monitors | This test case utilizes two monitors of type "ip-status" | | | and one monitor of type "process" to track the following | | | conditions: | +| | | | | 1. "ping_same_network_l2": monitor ICMP traffic between | | | VMs in the same Neutron network | | | | @@ -74,11 +76,13 @@ Yardstick Test Case Description TC087 | | | +--------------+--------------------------------------------------------------+ |operations | In this test case, the following operations are needed: | +| | | | | 1. "nova-create-instance-in_network": create a VM instance | | | in one of the existing Neutron network. | | | | +--------------+--------------------------------------------------------------+ |metrics | In this test case, there are two metrics: | +| | | | | 1. process_recover_time: which indicates the maximun | | | time (seconds) from the process being killed to | | | recovered | @@ -95,7 +99,9 @@ Yardstick Test Case Description TC087 | | | +--------------+--------------------------------------------------------------+ |configuration | This test case needs two configuration files: | +| | | | | 1. test case file: opnfv_yardstick_tc087.yaml | +| | | | | - Attackers: see above “attackers” discription | | | - waiting_time: which is the time (seconds) from the | | | process being killed to stoping monitors the monitors | @@ -126,7 +132,7 @@ Yardstick Test Case Description TC087 | | Neutron network. | | | | | | 2. Check connectivity from one VM to an external host on | -| | the Internet to verify SNAT functionality. +| | the Internet to verify SNAT functionality. | | | | | | Result: The monitor info will be collected. | | | | @@ -171,11 +177,14 @@ Yardstick Test Case Description TC087 |test verdict | This test fails if the SLAs are not met or if there is a | | | test case execution problem. The SLAs are define as follows | | | for this test: | +| | | | | * SDN Controller recovery | +| | | | | * process_recover_time <= 30 sec | | | | | | * no impact on data plane connectivity during SDN | | | controller failure and recovery. | +| | | | | * packet_drop == 0 | | | | +--------------+--------------------------------------------------------------+ |