diff options
author | Georg Kunz <georg.kunz@ericsson.com> | 2017-12-18 11:05:14 -0800 |
---|---|---|
committer | Georg Kunz <georg.kunz@ericsson.com> | 2018-03-13 10:29:04 +0100 |
commit | e0a358c21d684a0beee30c545dc5670528aceac4 (patch) | |
tree | f38ae18327d4fb019236bcf43603f3e3fde3f347 | |
parent | bbd3b027bd132568c258f02e36d9cc78c4629dfd (diff) |
Test case spec for SDN controller resilience in non-HA config
This is the test case specification for verifying the HA capabilities of
a SDN controller running in a non-HA configuration.
JIRA: HA-31
JIRA: YARDSTICK-955
Change-Id: I10f9ce4a2888092c033d2c02bf9a5a950b8b12dc
Signed-off-by: Georg Kunz <georg.kunz@ericsson.com>
-rw-r--r-- | docs/testing/user/userguide/15-list-of-tcs.rst | 1 | ||||
-rw-r--r-- | docs/testing/user/userguide/opnfv_yardstick_tc087.rst | 182 |
2 files changed, 183 insertions, 0 deletions
diff --git a/docs/testing/user/userguide/15-list-of-tcs.rst b/docs/testing/user/userguide/15-list-of-tcs.rst index 47526cdda..cb99c49cf 100644 --- a/docs/testing/user/userguide/15-list-of-tcs.rst +++ b/docs/testing/user/userguide/15-list-of-tcs.rst @@ -83,6 +83,7 @@ H A opnfv_yardstick_tc056.rst opnfv_yardstick_tc057.rst opnfv_yardstick_tc058.rst + opnfv_yardstick_tc087.rst IPv6 ---- diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc087.rst b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst new file mode 100644 index 000000000..99bfeebfc --- /dev/null +++ b/docs/testing/user/userguide/opnfv_yardstick_tc087.rst @@ -0,0 +1,182 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International +.. License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, Ericsson and others. + +************************************* +Yardstick Test Case Description TC087 +************************************* + ++-----------------------------------------------------------------------------+ +|SDN Controller resilience in non-HA configuration | +| | ++--------------+--------------------------------------------------------------+ +|test case id | OPNFV_YARDSTICK_TC087: SDN controller resilience in | +| | non-HA configuration | +| | | ++--------------+--------------------------------------------------------------+ +|test purpose | This test validates that network data plane services are | +| | highly available in the event of an SDN Controller failure, | +| | even if the SDN controller is deployed in a non-HA | +| | configuration. Specifically, the test verifies that | +| | existing data plane connectivity is not impacted, i.e. all | +| | configured network services such as DHCP, ARP, L2, | +| | L3 Security Groups should continue to operate | +| | between the existing VMs while the SDN controller is | +| | offline or rebooting. | +| | | +| | The test also validates that new network service operations | +| | (creating a new VM in the existing L2/L3 network or in a new | +| | network, etc.) are operational after the SDN controller | +| | has recovered from a failure. | +| | | ++--------------+--------------------------------------------------------------+ +|test method | This test case fails the SDN controller service running | +| | on the OpenStack controller node, then checks if already | +| | configured DHCP/ARP/L2/L3/SNAT connectivity is not | +| | impacted between VMs and the system is able to execute | +| | new virtual network operations once the SDN controller | +| | is restarted and has fully recovered | +| | | ++--------------+--------------------------------------------------------------+ +|attackers | In this test case, an attacker called “kill-process” is | +| | needed. This attacker includes three parameters: | +| | 1. fault_type: which is used for finding the attacker's | +| | scripts. It should be set to 'kill-process' in this test | +| | | +| | 2. process_name: should be set to the name of the SDN | +| | controller process | +| | | +| | 3. host: which is the name of a control node where the | +| | SDN controller process is running | +| | | +| | e.g. -fault_type: "kill-process" | +| | -process_name: "opendaylight" | +| | -host: node1 | +| | | ++--------------+--------------------------------------------------------------+ +|monitors | This test case utilizes two monitors of type "ip-status" | +| | and one monitor of type "process" to track the following | +| | conditions: | +| | 1. "ping_same_network_l2": monitor ICMP traffic between | +| | VMs in the same Neutron network | +| | | +| | 2. "ping_external_snat": monitor ICMP traffic from VMs to | +| | an external host on the Internet to verify SNAT | +| | functionality. | +| | | +| | 3. "SDN controller process monitor": a monitor checking the | +| | state of a specified SDN controller process. It measures | +| | the recovery time of the given process. | +| | | +| | Monitors of type "ip-status" use the "ping" utility to | +| | verify reachability of a given target IP. | +| | | ++--------------+--------------------------------------------------------------+ +|operations | In this test case, the following operations are needed: | +| | 1. "nova-create-instance-in_network": create a VM instance | +| | in one of the existing Neutron network. | +| | | ++--------------+--------------------------------------------------------------+ +|metrics | In this test case, there are two metrics: | +| | 1. process_recover_time: which indicates the maximun | +| | time (seconds) from the process being killed to | +| | recovered | +| | | +| | 2. packet_drop: measure the packets that have been dropped | +| | by the monitors using pktgen. | +| | | ++--------------+--------------------------------------------------------------+ +|test tool | Developed by the project. Please see folder: | +| | "yardstick/benchmark/scenarios/availability/ha_tools" | +| | | ++--------------+--------------------------------------------------------------+ +|references | none | +| | | ++--------------+--------------------------------------------------------------+ +|configuration | This test case needs two configuration files: | +| | 1. test case file: opnfv_yardstick_tc087.yaml | +| | - Attackers: see above “attackers” discription | +| | - waiting_time: which is the time (seconds) from the | +| | process being killed to stoping monitors the monitors | +| | - Monitors: see above “monitors” discription | +| | - SLA: see above “metrics” discription | +| | | +| | 2. POD file: pod.yaml The POD configuration should record | +| | on pod.yaml first. the “host” item in this test case | +| | will use the node name in the pod.yaml. | +| | | ++--------------+--------------------------------------------------------------+ +|test sequence | Description and expected result | +| | | ++--------------+--------------------------------------------------------------+ +|pre-action | 1. The OpenStack cluster is set up with a single SDN | +| | controller in a non-HA configuration. | +| | | +| | 2. One or more Neutron networks are created with two or | +| | more VMs attached to each of the Neutron networks. | +| | | +| | 3. The Neutron networks are attached to a Neutron router | +| | which is attached to an external network towards the | +| | DCGW. | +| | | ++--------------+--------------------------------------------------------------+ +|step 1 | Start IP connectivity monitors: | +| | 1. Check the L2 connectivity between the VMs in the same | +| | Neutron network. | +| | | +| | 2. Check connectivity from one VM to an external host on | +| | the Internet to verify SNAT functionality. +| | | +| | Result: The monitor info will be collected. | +| | | ++--------------+--------------------------------------------------------------+ +|step 2 | Start attacker: | +| | SSH connect to the VIM node and kill the SDN controller | +| | process | +| | | +| | Result: the SDN controller service will be shutdown | +| | | ++--------------+--------------------------------------------------------------+ +|step 3 | Verify the results of the IP connectivity monitors. | +| | | +| | Result: The outage_time metric reported by the monitors | +| | is zero. | +| | | ++--------------+--------------------------------------------------------------+ +|step 4 | Restart the SDN controller. | +| | | ++--------------+--------------------------------------------------------------+ +|step 5 | Create a new VM in the existing Neutron network | +| | | ++--------------+--------------------------------------------------------------+ +|step 6 | Verify connectivity between VMs as follows: | +| | 1. Check the L2 connectivity between the previously | +| | existing VM and the newly created VM on the same | +| | Neutron network by sending ICMP messages | +| | | ++--------------+--------------------------------------------------------------+ +|step 7 | Stop IP connectivity monitors after a period of time | +| | specified by “waiting_time” | +| | | +| | Result: The monitor info will be aggregated | +| | | ++--------------+--------------------------------------------------------------+ +|step 8 | Verify the IP connectivity monitor results | +| | | +| | Result: IP connectivity monitor should not have any packet | +| | drop failures reported | +| | | ++--------------+--------------------------------------------------------------+ +|test verdict | This test fails if the SLAs are not met or if there is a | +| | test case execution problem. The SLAs are define as follows | +| | for this test: | +| | * SDN Controller recovery | +| | * process_recover_time <= 30 sec | +| | | +| | * no impact on data plane connectivity during SDN | +| | controller failure and recovery. | +| | * packet_drop == 0 | +| | | ++--------------+--------------------------------------------------------------+ + |