1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
|
===========================
'vsperf' Traffic Gen Guide
===========================
Overview
---------------------
VSPERF supports the following traffic generators:
* Dummy (DEFAULT): Allows you to use your own external
traffic generator.
* IXIA (IxNet and IxOS)
* Spirent TestCenter
To see the list of traffic gens from the cli:
.. code-block:: console
./vsperf --list-trafficgens
This guide provides the details of how to install
and configure the various traffic generators.
Background Information
----------------------
The traffic default configuration can be found in
tools/pkt_gen/trafficgen/trafficgenhelper.py, and is configured as
follows:
.. code-block:: console
TRAFFIC_DEFAULTS = {
'l2': {
'framesize': 64,
'srcmac': '00:00:00:00:00:00',
'dstmac': '00:00:00:00:00:00',
'srcport': 3000,
'dstport': 3001,
},
'l3': {
'proto': 'tcp',
'srcip': '1.1.1.1',
'dstip': '90.90.90.90',
},
'vlan': {
'enabled': False,
'id': 0,
'priority': 0,
'cfi': 0,
},
}
The framesize paramter can be overridden from the configuration
files by adding the following to your custom configuration file
``10_custom.conf``:
.. code-block:: console
TRAFFICGEN_PKT_SIZES = (64, 128,)
OR from the commandline:
.. code-block:: console
./vsperf --test-param "pkt_sizes=x,y" $TESTNAME
You can also modify the traffic transmission duration and the number
of trials run by the traffic generator by extending the example
commandline above to:
.. code-block:: console
./vsperf --test-param "pkt_sizes=x,y;duration=10;rfc2455_trials=3" $TESTNAME
Dummy Setup
------------
To select the Dummy generator please add the following to your
custom configuration file ``10_custom.conf``.
.. code-block:: console
TRAFFICGEN = 'Dummy'
OR run ``vsperf`` with the ``--trafficgen`` argument
.. code-block:: console
./vsperf --trafficgen Dummy $TESTNAME
Where $TESTNAME is the name of the vsperf test you would like to run.
This will setup the vSwitch and the VNF (if one is part of your test)
print the traffic configuration and prompt you to transmit traffic
when the setup is complete.
.. code-block:: console
Please send 'continuous' traffic with the following stream config:
30mS, 90mpps, multistream False
and the following flow config:
{
"flow_type": "port",
"l3": {
"srcip": "1.1.1.1",
"proto": "tcp",
"dstip": "90.90.90.90"
},
"traffic_type": "continuous",
"multistream": 0,
"bidir": "True",
"vlan": {
"cfi": 0,
"priority": 0,
"id": 0,
"enabled": false
},
"frame_rate": 90,
"l2": {
"dstport": 3001,
"srcport": 3000,
"dstmac": "00:00:00:00:00:00",
"srcmac": "00:00:00:00:00:00",
"framesize": 64
}
}
What was the result for 'frames tx'?
When your traffic gen has completed traffic transmission and provided
the results please input these at the vsperf prompt. vsperf will try
to verify the input:
.. code-block:: console
Is '$input_value' correct?
Please answer with y OR n.
VPSERF will ask you for:
* Result for 'frames tx'
* Result for 'frames rx'
* Result for 'min latency'
* Result for 'max latency'
* Result for 'avg latency'
Finally vsperf will print out the results for your test and generate the
appropriate logs and csv files.
IXIA Setup
----------
On the CentOS 7 system
~~~~~~~~~~~~~~~~~~~~~~
You need to install IxNetworkTclClient$(VER\_NUM)Linux.bin.tgz.
On the IXIA client software system
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Find the IxNetwork TCL server app (start -> All Programs -> IXIA ->
IxNetwork -> IxNetwork\_$(VER\_NUM) -> IxNetwork TCL Server)
Right click on IxNetwork TCL Server, select properties - Under shortcut tab in
the Target dialogue box make sure there is the argument "-tclport xxxx"
where xxxx is your port number (take note of this port number you will
need it for the 10\_custom.conf file).
.. image:: TCLServerProperties.png
Hit Ok and start the TCL server application
Spirent Setup
-------------
Spirent installation files and instructions are available on the
Spirent support website at:
http://support.spirent.com
Select a version of Spirent TestCenter software to utilize. This example
will use Spirent TestCenter v4.57 as an example. Substitute the appropriate
version in place of 'v4.57' in the examples, below.
On the CentOS 7 System
~~~~~~~~~~~~~~~~~~~~~~
Download and install the following:
Spirent TestCenter Application, v4.57 for 64-bit Linux Client
Spirent Virtual Deployment Service (VDS)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Spirent VDS is required for both TestCenter hardware and virtual
chassis in the vsperf environment. For installation, select the version
that matches the Spirent TestCenter Application version. For v4.57,
the matching VDS version is 1.0.55. Download either the ova (VMware)
or qcow2 (QEMU) image and create a VM with it. Initialize the VM
according to Spirent installation instructions.
Using Spirent TestCenter Virtual (STCv)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
STCv is available in both ova (VMware) and qcow2 (QEMU) formats. For
VMware, download:
Spirent TestCenter Virtual Machine for VMware, v4.57 for Hypervisor - VMware ESX.ESXi
Virtual test port performance is affected by the hypervisor configuration. For
best practice results in deploying STCv, the following is suggested:
- Create a single VM with two test ports rather than two VMs with one port each
- Set STCv in DPDK mode
- Give STCv 2*n + 1 cores, where n = the number of ports. For vsperf, cores = 5.
- Turning off hyperthreading and pinning these cores will improve performance
- Give STCv 2 GB of RAM
To get the highest performance and accuracy, Spirent TestCenter hardware is
recommended. vsperf can run with either stype test ports.
|