summaryrefslogtreecommitdiffstats
path: root/docs/testing
diff options
context:
space:
mode:
Diffstat (limited to 'docs/testing')
-rw-r--r--docs/testing/developer/devguide/results/results.rst42
1 files changed, 16 insertions, 26 deletions
diff --git a/docs/testing/developer/devguide/results/results.rst b/docs/testing/developer/devguide/results/results.rst
index df9c52cb..0a0ab75d 100644
--- a/docs/testing/developer/devguide/results/results.rst
+++ b/docs/testing/developer/devguide/results/results.rst
@@ -7,32 +7,22 @@ OPNFV Test Results
VSPERF CI jobs are run daily and sample results can be found at
https://wiki.opnfv.org/display/vsperf/Vsperf+Results
-The following example maps the results in the test dashboard to the appropriate
-test case in the VSPERF Framework and specifies the metric the vertical/Y axis
-is plotting. **Please note**, the presence of dpdk within a test name signifies
-that the vswitch under test was OVS with DPDK, while its absence indicates that
-the vswitch under test was stock OVS.
+Testcase names shown in the dashboard are combination of orignal testcase
+name from VSPERF framework and indication of used vswitch.
-===================== ===================== ================== ===============
- Dashboard Test Framework Test Metric Guest Interface
-===================== ===================== ================== ===============
-tput_ovsdpdk phy2phy_tput Throughput (FPS) N/A
-tput_ovs phy2phy_tput Throughput (FPS) N/A
-b2b_ovsdpdk back2back Back-to-back value N/A
-b2b_ovs back2back Back-to-back value N/A
-tput_mod_vlan_ovs phy2phy_tput_mod_vlan Throughput (FPS) N/A
-tput_mod_vlan_ovsdpdk phy2phy_tput_mod_vlan Throughput (FPS) N/A
-scalability_ovs phy2phy_scalability Throughput (FPS) N/A
-scalability_ovsdpdk phy2phy_scalability Throughput (FPS) N/A
-pvp_tput_ovsdpdkuser pvp_tput Throughput (FPS) vhost-user
-pvp_tput_ovsvirtio pvp_tput Throughput (FPS) virtio-net
-pvp_b2b_ovsdpdkuser pvp_back2back Back-to-back value vhost-user
-pvp_b2b_ovsvirtio pvp_back2back Back-to-back value virtio-net
-pvvp_tput_ovsdpdkuser pvvp_tput Throughput (FPS) vhost-user
-pvvp_tput_ovsvirtio pvvp_tput Throughput (FPS) virtio-net
-pvvp_b2b_ovsdpdkuser pvvp_back2back Throughput (FPS) vhost-user
-pvvp_b2b_ovsvirtio pvvp_back2back Throughput (FPS) virtio-net
-===================== ===================== ================== ===============
+ Example:
-The loopback application in the VNF was used for PVP and PVVP scenarios was DPDK
+ Testcase ``phy2phy_tput`` is executed for three vSwitch types: ``OvsDpdkVhost``,
+ ``OvsVanilla`` and ``VppDpdkVhost``. In this case, following testcase names
+ will be used in the dashboard: ``phy2phy_tput_ovsdpdkvhost``,
+ ``phy2phy_tput_ovsvanilla`` and ``phy2phy_tput_vppdpdkvhost``.
+
+In case of RFC2544 Throughput test, the recorded metric is FPS (frames per
+second) without packet loss. For RFC2544 Back2Back test, the recorded metric
+is back-to-back value (number of frames) without packet loss.
+
+The loopback application in the VNF used for PVP and PVVP scenarios was DPDK
testpmd.
+
+Guest interface types are ``vhost-user`` for ``OvsDpdkVhost`` and ``VppDpdkVhost``
+and ``virtio-net`` for ``OvsVanilla``.