diff options
Diffstat (limited to 'docs/testing/user/userguide/testusage.rst')
-rw-r--r-- | docs/testing/user/userguide/testusage.rst | 809 |
1 files changed, 809 insertions, 0 deletions
diff --git a/docs/testing/user/userguide/testusage.rst b/docs/testing/user/userguide/testusage.rst new file mode 100644 index 00000000..0055164e --- /dev/null +++ b/docs/testing/user/userguide/testusage.rst @@ -0,0 +1,809 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, Intel Corporation, AT&T and others. + +vSwitchPerf test suites userguide +--------------------------------- + +General +^^^^^^^ + +VSPERF requires a traffic generators to run tests, automated traffic gen +support in VSPERF includes: + +- IXIA traffic generator (IxNetwork hardware) and a machine that runs the IXIA + client software. +- Spirent traffic generator (TestCenter hardware chassis or TestCenter virtual + in a VM) and a VM to run the Spirent Virtual Deployment Service image, + formerly known as "Spirent LabServer". +- Xena Network traffic generator (Xena hardware chassis) that houses the Xena + Traffic generator modules. +- Moongen software traffic generator. Requires a separate machine running + moongen to execute packet generation. + +If you want to use another traffic generator, please select the :ref:`trafficgen-dummy` +generator. + +VSPERF Installation +^^^^^^^^^^^^^^^^^^^ + +To see the supported Operating Systems, vSwitches and system requirements, +please follow the `installation instructions <vsperf-installation>`. + +Traffic Generator Setup +^^^^^^^^^^^^^^^^^^^^^^^ + +Follow the `Traffic generator instructions <trafficgen-installation>` to +install and configure a suitable traffic generator. + +Cloning and building src dependencies +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +In order to run VSPERF, you will need to download DPDK and OVS. You can +do this manually and build them in a preferred location, OR you could +use vswitchperf/src. The vswitchperf/src directory contains makefiles +that will allow you to clone and build the libraries that VSPERF depends +on, such as DPDK and OVS. To clone and build simply: + +.. code-block:: console + + $ cd src + $ make + +VSPERF can be used with stock OVS (without DPDK support). When build +is finished, the libraries are stored in src_vanilla directory. + +The 'make' builds all options in src: + +* Vanilla OVS +* OVS with vhost_user as the guest access method (with DPDK support) + +The vhost_user build will reside in src/ovs/ +The Vanilla OVS build will reside in vswitchperf/src_vanilla + +To delete a src subdirectory and its contents to allow you to re-clone simply +use: + +.. code-block:: console + + $ make clobber + +Configure the ``./conf/10_custom.conf`` file +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +The ``10_custom.conf`` file is the configuration file that overrides +default configurations in all the other configuration files in ``./conf`` +The supplied ``10_custom.conf`` file **MUST** be modified, as it contains +configuration items for which there are no reasonable default values. + +The configuration items that can be added is not limited to the initial +contents. Any configuration item mentioned in any .conf file in +``./conf`` directory can be added and that item will be overridden by +the custom configuration value. + +Further details about configuration files evaluation and special behaviour +of options with ``GUEST_`` prefix could be found at :ref:`design document +<design-configuration>`. + +Using a custom settings file +^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +If your ``10_custom.conf`` doesn't reside in the ``./conf`` directory +of if you want to use an alternative configuration file, the file can +be passed to ``vsperf`` via the ``--conf-file`` argument. + +.. code-block:: console + + $ ./vsperf --conf-file <path_to_custom_conf> ... + +Note that configuration passed in via the environment (``--load-env``) +or via another command line argument will override both the default and +your custom configuration files. This "priority hierarchy" can be +described like so (1 = max priority): + +1. Testcase definition section ``Parameters`` +2. Command line arguments +3. Environment variables +4. Configuration file(s) + +Further details about configuration files evaluation and special behaviour +of options with ``GUEST_`` prefix could be found at :ref:`design document +<design-configuration>`. + +.. _overriding-parameters-documentation: + +Overriding values defined in configuration files +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +The configuration items can be overridden by command line argument +``--test-params``. In this case, the configuration items and +their values should be passed in form of ``item=value`` and separated +by semicolon. + +Example: + +.. code:: console + + $ ./vsperf --test-params "TRAFFICGEN_DURATION=10;TRAFFICGEN_PKT_SIZES=(128,);" \ + "GUEST_LOOPBACK=['testpmd','l2fwd']" pvvp_tput + +The second option is to override configuration items by ``Parameters`` section +of the test case definition. The configuration items can be added into ``Parameters`` +dictionary with their new values. These values will override values defined in +configuration files or specified by ``--test-params`` command line argument. + +Example: + +.. code:: python + + "Parameters" : {'TRAFFICGEN_PKT_SIZES' : (128,), + 'TRAFFICGEN_DURATION' : 10, + 'GUEST_LOOPBACK' : ['testpmd','l2fwd'], + } + +**NOTE:** In both cases, configuration item names and their values must be specified +in the same form as they are defined inside configuration files. Parameter names +must be specified in uppercase and data types of original and new value must match. +Python syntax rules related to data types and structures must be followed. +For example, parameter ``TRAFFICGEN_PKT_SIZES`` above is defined as a tuple +with a single value ``128``. In this case trailing comma is mandatory, otherwise +value can be wrongly interpreted as a number instead of a tuple and vsperf +execution would fail. Please check configuration files for default values and their +types and use them as a basis for any customized values. In case of any doubt, please +check official python documentation related to data structures like tuples, lists +and dictionaries. + +**NOTE:** Vsperf execution will terminate with runtime error in case, that unknown +parameter name is passed via ``--test-params`` CLI argument or defined in ``Parameters`` +section of test case definition. It is also forbidden to redefine a value of +``TEST_PARAMS`` configuration item via CLI or ``Parameters`` section. + +vloop_vnf +^^^^^^^^^ + +VSPERF uses a VM image called vloop_vnf for looping traffic in the deployment +scenarios involving VMs. The image can be downloaded from +`<http://artifacts.opnfv.org/>`__. + +Please see the installation instructions for information on :ref:`vloop-vnf` +images. + +.. _l2fwd-module: + +l2fwd Kernel Module +^^^^^^^^^^^^^^^^^^^ + +A Kernel Module that provides OSI Layer 2 Ipv4 termination or forwarding with +support for Destination Network Address Translation (DNAT) for both the MAC and +IP addresses. l2fwd can be found in <vswitchperf_dir>/src/l2fwd + +Executing tests +^^^^^^^^^^^^^^^ + +All examples inside these docs assume, that user is inside the VSPERF +directory. VSPERF can be executed from any directory. + +Before running any tests make sure you have root permissions by adding +the following line to /etc/sudoers: + +.. code-block:: console + + username ALL=(ALL) NOPASSWD: ALL + +username in the example above should be replaced with a real username. + +To list the available tests: + +.. code-block:: console + + $ ./vsperf --list + +To run a single test: + +.. code-block:: console + + $ ./vsperf $TESTNAME + +Where $TESTNAME is the name of the vsperf test you would like to run. + +To run a group of tests, for example all tests with a name containing +'RFC2544': + +.. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf --tests="RFC2544" + +To run all tests: + +.. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf + +Some tests allow for configurable parameters, including test duration +(in seconds) as well as packet sizes (in bytes). + +.. code:: bash + + $ ./vsperf --conf-file user_settings.py \ + --tests RFC2544Tput \ + --test-params "TRAFFICGEN_DURATION=10;TRAFFICGEN_PKT_SIZES=(128,)" + +For all available options, check out the help dialog: + +.. code-block:: console + + $ ./vsperf --help + +Executing Vanilla OVS tests +^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +1. If needed, recompile src for all OVS variants + + .. code-block:: console + + $ cd src + $ make distclean + $ make + +2. Update your ``10_custom.conf`` file to use Vanilla OVS: + + .. code-block:: python + + VSWITCH = 'OvsVanilla' + +3. Run test: + + .. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf> + + Please note if you don't want to configure Vanilla OVS through the + configuration file, you can pass it as a CLI argument. + + .. code-block:: console + + $ ./vsperf --vswitch OvsVanilla + + +Executing tests with VMs +^^^^^^^^^^^^^^^^^^^^^^^^ + +To run tests using vhost-user as guest access method: + +1. Set VHOST_METHOD and VNF of your settings file to: + + .. code-block:: python + + VSWITCH = 'OvsDpdkVhost' + VNF = 'QemuDpdkVhost' + +2. If needed, recompile src for all OVS variants + + .. code-block:: console + + $ cd src + $ make distclean + $ make + +3. Run test: + + .. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf + +Executing tests with VMs using Vanilla OVS +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +To run tests using Vanilla OVS: + +1. Set the following variables: + + .. code-block:: python + + VSWITCH = 'OvsVanilla' + VNF = 'QemuVirtioNet' + + VANILLA_TGEN_PORT1_IP = n.n.n.n + VANILLA_TGEN_PORT1_MAC = nn:nn:nn:nn:nn:nn + + VANILLA_TGEN_PORT2_IP = n.n.n.n + VANILLA_TGEN_PORT2_MAC = nn:nn:nn:nn:nn:nn + + VANILLA_BRIDGE_IP = n.n.n.n + + or use ``--test-params`` option + + .. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf \ + --test-params "VANILLA_TGEN_PORT1_IP=n.n.n.n;" \ + "VANILLA_TGEN_PORT1_MAC=nn:nn:nn:nn:nn:nn;" \ + "VANILLA_TGEN_PORT2_IP=n.n.n.n;" \ + "VANILLA_TGEN_PORT2_MAC=nn:nn:nn:nn:nn:nn" + +2. If needed, recompile src for all OVS variants + + .. code-block:: console + + $ cd src + $ make distclean + $ make + +3. Run test: + + .. code-block:: console + + $ ./vsperf --conf-file<path_to_custom_conf>/10_custom.conf + +.. _vfio-pci: + +Using vfio_pci with DPDK +^^^^^^^^^^^^^^^^^^^^^^^^^ + +To use vfio with DPDK instead of igb_uio add into your custom configuration +file the following parameter: + +.. code-block:: python + + PATHS['dpdk']['src']['modules'] = ['uio', 'vfio-pci'] + + +**NOTE:** In case, that DPDK is installed from binary package, then please +set ``PATHS['dpdk']['bin']['modules']`` instead. + +**NOTE:** Please ensure that Intel VT-d is enabled in BIOS. + +**NOTE:** Please ensure your boot/grub parameters include +the following: + +.. code-block:: console + + iommu=pt intel_iommu=on + +To check that IOMMU is enabled on your platform: + +.. code-block:: console + + $ dmesg | grep IOMMU + [ 0.000000] Intel-IOMMU: enabled + [ 0.139882] dmar: IOMMU 0: reg_base_addr fbffe000 ver 1:0 cap d2078c106f0466 ecap f020de + [ 0.139888] dmar: IOMMU 1: reg_base_addr ebffc000 ver 1:0 cap d2078c106f0466 ecap f020de + [ 0.139893] IOAPIC id 2 under DRHD base 0xfbffe000 IOMMU 0 + [ 0.139894] IOAPIC id 0 under DRHD base 0xebffc000 IOMMU 1 + [ 0.139895] IOAPIC id 1 under DRHD base 0xebffc000 IOMMU 1 + [ 3.335744] IOMMU: dmar0 using Queued invalidation + [ 3.335746] IOMMU: dmar1 using Queued invalidation + .... + +.. _SRIOV-support: + +Using SRIOV support +^^^^^^^^^^^^^^^^^^^ + +To use virtual functions of NIC with SRIOV support, use extended form +of NIC PCI slot definition: + +.. code-block:: python + + WHITELIST_NICS = ['0000:05:00.0|vf0', '0000:05:00.1|vf3'] + +Where 'vf' is an indication of virtual function usage and following +number defines a VF to be used. In case that VF usage is detected, +then vswitchperf will enable SRIOV support for given card and it will +detect PCI slot numbers of selected VFs. + +So in example above, one VF will be configured for NIC '0000:05:00.0' +and four VFs will be configured for NIC '0000:05:00.1'. Vswitchperf +will detect PCI addresses of selected VFs and it will use them during +test execution. + +At the end of vswitchperf execution, SRIOV support will be disabled. + +SRIOV support is generic and it can be used in different testing scenarios. +For example: + +* vSwitch tests with DPDK or without DPDK support to verify impact + of VF usage on vSwitch performance +* tests without vSwitch, where traffic is forwared directly + between VF interfaces by packet forwarder (e.g. testpmd application) +* tests without vSwitch, where VM accesses VF interfaces directly + by PCI-passthrough_ to measure raw VM throughput performance. + +.. _PCI-passthrough: + +Using QEMU with PCI passthrough support +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Raw virtual machine throughput performance can be measured by execution of PVP +test with direct access to NICs by PCI passthrough. To execute VM with direct +access to PCI devices, enable vfio-pci_. In order to use virtual functions, +SRIOV-support_ must be enabled. + +Execution of test with PCI passthrough with vswitch disabled: + +.. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf \ + --vswitch none --vnf QemuPciPassthrough pvp_tput + +Any of supported guest-loopback-application_ can be used inside VM with +PCI passthrough support. + +Note: Qemu with PCI passthrough support can be used only with PVP test +deployment. + +.. _guest-loopback-application: + +Selection of loopback application for tests with VMs +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +To select the loopback applications which will forward packets inside VMs, +the following parameter should be configured: + +.. code-block:: python + + GUEST_LOOPBACK = ['testpmd'] + +or use ``--test-params`` CLI argument: + +.. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf \ + --test-params "GUEST_LOOPBACK=['testpmd']" + +Supported loopback applications are: + +.. code-block:: console + + 'testpmd' - testpmd from dpdk will be built and used + 'l2fwd' - l2fwd module provided by Huawei will be built and used + 'linux_bridge' - linux bridge will be configured + 'buildin' - nothing will be configured by vsperf; VM image must + ensure traffic forwarding between its interfaces + +Guest loopback application must be configured, otherwise traffic +will not be forwarded by VM and testcases with VM related deployments +will fail. Guest loopback application is set to 'testpmd' by default. + +**NOTE:** In case that only 1 or more than 2 NICs are configured for VM, +then 'testpmd' should be used. As it is able to forward traffic between +multiple VM NIC pairs. + +**NOTE:** In case of linux_bridge, all guest NICs are connected to the same +bridge inside the guest. + +Mergable Buffers Options with QEMU +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Mergable buffers can be disabled with VSPerf within QEMU. This option can +increase performance significantly when not using jumbo frame sized packets. +By default VSPerf disables mergable buffers. If you wish to enable it you +can modify the setting in the a custom conf file. + +.. code-block:: python + + GUEST_NIC_MERGE_BUFFERS_DISABLE = [False] + +Then execute using the custom conf file. + +.. code-block:: console + + $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf + +Alternatively you can just pass the param during execution. + +.. code-block:: console + + $ ./vsperf --test-params "GUEST_NIC_MERGE_BUFFERS_DISABLE=[False]" + + +Selection of dpdk binding driver for tests with VMs +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +To select dpdk binding driver, which will specify which driver the vm NICs will +use for dpdk bind, the following configuration parameter should be configured: + +.. code-block:: console + + GUEST_DPDK_BIND_DRIVER = ['igb_uio_from_src'] + +The supported dpdk guest bind drivers are: + +.. code-block:: console + + 'uio_pci_generic' - Use uio_pci_generic driver + 'igb_uio_from_src' - Build and use the igb_uio driver from the dpdk src + files + 'vfio_no_iommu' - Use vfio with no iommu option. This requires custom + guest images that support this option. The default + vloop image does not support this driver. + +Note: uio_pci_generic does not support sr-iov testcases with guests attached. +This is because uio_pci_generic only supports legacy interrupts. In case +uio_pci_generic is selected with the vnf as QemuPciPassthrough it will be +modified to use igb_uio_from_src instead. + +Note: vfio_no_iommu requires kernels equal to or greater than 4.5 and dpdk +16.04 or greater. Using this option will also taint the kernel. + +Please refer to the dpdk documents at http://dpdk.org/doc/guides for more +information on these drivers. + +Multi-Queue Configuration +^^^^^^^^^^^^^^^^^^^^^^^^^ + +VSPerf currently supports multi-queue with the following limitations: + +1. Requires QEMU 2.5 or greater and any OVS version higher than 2.5. The + default upstream package versions installed by VSPerf satisfies this + requirement. + +2. Guest image must have ethtool utility installed if using l2fwd or linux + bridge inside guest for loopback. + +3. If using OVS versions 2.5.0 or less enable old style multi-queue as shown + in the ''02_vswitch.conf'' file. + + .. code-block:: python + + OVS_OLD_STYLE_MQ = True + +To enable multi-queue for dpdk modify the ''02_vswitch.conf'' file. + +.. code-block:: python + + VSWITCH_DPDK_MULTI_QUEUES = 2 + +**NOTE:** you should consider using the switch affinity to set a pmd cpu mask +that can optimize your performance. Consider the numa of the NIC in use if this +applies by checking /sys/class/net/<eth_name>/device/numa_node and setting an +appropriate mask to create PMD threads on the same numa node. + +When multi-queue is enabled, each dpdk or dpdkvhostuser port that is created +on the switch will set the option for multiple queues. If old style multi queue +has been enabled a global option for multi queue will be used instead of the +port by port option. + +To enable multi-queue on the guest modify the ''04_vnf.conf'' file. + +.. code-block:: python + + GUEST_NIC_QUEUES = [2] + +Enabling multi-queue at the guest will add multiple queues to each NIC port when +qemu launches the guest. + +In case of Vanilla OVS, multi-queue is enabled on the tuntap ports and nic +queues will be enabled inside the guest with ethtool. Simply enabling the +multi-queue on the guest is sufficient for Vanilla OVS multi-queue. + +Testpmd should be configured to take advantage of multi-queue on the guest if +using DPDKVhostUser. This can be done by modifying the ''04_vnf.conf'' file. + +.. code-block:: python + + GUEST_TESTPMD_PARAMS = ['-l 0,1,2,3,4 -n 4 --socket-mem 512 -- ' + '--burst=64 -i --txqflags=0xf00 ' + '--nb-cores=4 --rxq=2 --txq=2 ' + '--disable-hw-vlan'] + +**NOTE:** The guest SMP cores must be configured to allow for testpmd to use the +optimal number of cores to take advantage of the multiple guest queues. + +In case of using Vanilla OVS and qemu virtio-net you can increase performance +by binding vhost-net threads to cpus. This can be done by enabling the affinity +in the ''04_vnf.conf'' file. This can be done to non multi-queue enabled +configurations as well as there will be 2 vhost-net threads. + +.. code-block:: python + + VSWITCH_VHOST_NET_AFFINITIZATION = True + + VSWITCH_VHOST_CPU_MAP = [4,5,8,11] + +**NOTE:** This method of binding would require a custom script in a real +environment. + +**NOTE:** For optimal performance guest SMPs and/or vhost-net threads should be +on the same numa as the NIC in use if possible/applicable. Testpmd should be +assigned at least (nb_cores +1) total cores with the cpu mask. + +Executing Packet Forwarding tests +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +To select the applications which will forward packets, +the following parameters should be configured: + +.. code-block:: python + + VSWITCH = 'none' + PKTFWD = 'TestPMD' + +or use ``--vswitch`` and ``--fwdapp`` CLI arguments: + +.. code-block:: console + + $ ./vsperf phy2phy_cont --conf-file user_settings.py \ + --vswitch none \ + --fwdapp TestPMD + +Supported Packet Forwarding applications are: + +.. code-block:: console + + 'testpmd' - testpmd from dpdk + + +1. Update your ''10_custom.conf'' file to use the appropriate variables + for selected Packet Forwarder: + + .. code-block:: python + + # testpmd configuration + TESTPMD_ARGS = [] + # packet forwarding mode supported by testpmd; Please see DPDK documentation + # for comprehensive list of modes supported by your version. + # e.g. io|mac|mac_retry|macswap|flowgen|rxonly|txonly|csum|icmpecho|... + # Note: Option "mac_retry" has been changed to "mac retry" since DPDK v16.07 + TESTPMD_FWD_MODE = 'csum' + # checksum calculation layer: ip|udp|tcp|sctp|outer-ip + TESTPMD_CSUM_LAYER = 'ip' + # checksum calculation place: hw (hardware) | sw (software) + TESTPMD_CSUM_CALC = 'sw' + # recognize tunnel headers: on|off + TESTPMD_CSUM_PARSE_TUNNEL = 'off' + +2. Run test: + + .. code-block:: console + + $ ./vsperf phy2phy_tput --conf-file <path_to_settings_py> + +Executing Packet Forwarding tests with one guest +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +TestPMD with DPDK 16.11 or greater can be used to forward packets as a switch to a single guest using TestPMD vdev +option. To set this configuration the following parameters should be used. + + .. code-block:: python + + VSWITCH = 'none' + PKTFWD = 'TestPMD' + +or use ``--vswitch`` and ``--fwdapp`` CLI arguments: + + .. code-block:: console + + $ ./vsperf pvp_tput --conf-file user_settings.py \ + --vswitch none \ + --fwdapp TestPMD + +Guest forwarding application only supports TestPMD in this configuration. + + .. code-block:: python + + GUEST_LOOPBACK = ['testpmd'] + +For optimal performance one cpu per port +1 should be used for TestPMD. Also set additional params for packet forwarding +application to use the correct number of nb-cores. + + .. code-block:: python + + VSWITCHD_DPDK_ARGS = ['-l', '46,44,42,40,38', '-n', '4', '--socket-mem 1024,0'] + TESTPMD_ARGS = ['--nb-cores=4', '--txq=1', '--rxq=1'] + +For guest TestPMD 3 VCpus should be assigned with the following TestPMD params. + + .. code-block:: python + + GUEST_TESTPMD_PARAMS = ['-l 0,1,2 -n 4 --socket-mem 1024 -- ' + '--burst=64 -i --txqflags=0xf00 ' + '--disable-hw-vlan --nb-cores=2 --txq=1 --rxq=1'] + +Execution of TestPMD can be run with the following command line + + .. code-block:: console + + ./vsperf pvp_tput --vswitch=none --fwdapp=TestPMD --conf-file <path_to_settings_py> + +**NOTE:** To achieve the best 0% loss numbers with rfc2544 throughput testing, other tunings should be applied to host +and guest such as tuned profiles and CPU tunings to prevent possible interrupts to worker threads. + +VSPERF modes of operation +^^^^^^^^^^^^^^^^^^^^^^^^^ + +VSPERF can be run in different modes. By default it will configure vSwitch, +traffic generator and VNF. However it can be used just for configuration +and execution of traffic generator. Another option is execution of all +components except traffic generator itself. + +Mode of operation is driven by configuration parameter -m or --mode + +.. code-block:: console + + -m MODE, --mode MODE vsperf mode of operation; + Values: + "normal" - execute vSwitch, VNF and traffic generator + "trafficgen" - execute only traffic generator + "trafficgen-off" - execute vSwitch and VNF + "trafficgen-pause" - execute vSwitch and VNF but wait before traffic transmission + +In case, that VSPERF is executed in "trafficgen" mode, then configuration +of traffic generator can be modified through ``TRAFFIC`` dictionary passed to the +``--test-params`` option. It is not needed to specify all values of ``TRAFFIC`` +dictionary. It is sufficient to specify only values, which should be changed. +Detailed description of ``TRAFFIC`` dictionary can be found at +:ref:`configuration-of-traffic-dictionary`. + +Example of execution of VSPERF in "trafficgen" mode: + +.. code-block:: console + + $ ./vsperf -m trafficgen --trafficgen IxNet --conf-file vsperf.conf \ + --test-params "TRAFFIC={'traffic_type':'rfc2544_continuous','bidir':'False','framerate':60}" + +Code change verification by pylint +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Every developer participating in VSPERF project should run +pylint before his python code is submitted for review. Project +specific configuration for pylint is available at 'pylint.rc'. + +Example of manual pylint invocation: + +.. code-block:: console + + $ pylint --rcfile ./pylintrc ./vsperf + +GOTCHAs: +^^^^^^^^ + +Custom image fails to boot +~~~~~~~~~~~~~~~~~~~~~~~~~~ + +Using custom VM images may not boot within VSPerf pxp testing because of +the drive boot and shared type which could be caused by a missing scsi +driver inside the image. In case of issues you can try changing the drive +boot type to ide. + +.. code-block:: python + + GUEST_BOOT_DRIVE_TYPE = ['ide'] + GUEST_SHARED_DRIVE_TYPE = ['ide'] + +OVS with DPDK and QEMU +~~~~~~~~~~~~~~~~~~~~~~~ + +If you encounter the following error: "before (last 100 chars): +'-path=/dev/hugepages,share=on: unable to map backing store for +hugepages: Cannot allocate memory\r\n\r\n" during qemu initialization, +check the amount of hugepages on your system: + +.. code-block:: console + + $ cat /proc/meminfo | grep HugePages + + +By default the vswitchd is launched with 1Gb of memory, to change +this, modify --socket-mem parameter in conf/02_vswitch.conf to allocate +an appropriate amount of memory: + +.. code-block:: python + + VSWITCHD_DPDK_ARGS = ['-c', '0x4', '-n', '4', '--socket-mem 1024,0'] + VSWITCHD_DPDK_CONFIG = { + 'dpdk-init' : 'true', + 'dpdk-lcore-mask' : '0x4', + 'dpdk-socket-mem' : '1024,0', + } + +Note: Option VSWITCHD_DPDK_ARGS is used for vswitchd, which supports --dpdk +parameter. In recent vswitchd versions, option VSWITCHD_DPDK_CONFIG will be +used to configure vswitchd via ovs-vsctl calls. + + +More information +^^^^^^^^^^^^^^^^ + +For more information and details refer to the rest of vSwitchPerfuser documentation. + |