summaryrefslogtreecommitdiffstats
path: root/docs/userguides
diff options
context:
space:
mode:
authorMaryam Tahhan <maryam.tahhan@intel.com>2016-01-25 10:58:47 +0000
committerMaryam Tahhan <maryam.tahhan@intel.com>2016-01-25 16:41:08 +0000
commit276d16fd75a717e5f5004e117cb9d3b18fd37363 (patch)
tree98381c5cd8cc76f67a04c38f67da01aaf8b9bf09 /docs/userguides
parentcdda1e1aaaae6c22a592980cabd6f301d661f737 (diff)
docs: updates and final fixes
Migrate the installation guide for vsperf to a configguide directory, update the links to the installation guide. Re-add top level index.rst and remove the all directory. Update release documentation with vsperf Rel B support. Change-Id: Ib643b9d3581d8109b85c377027c8cc6be4b797fc Signed-off-by: Maryam Tahhan <maryam.tahhan@intel.com> Reviewed-by: Martin Klozik <martinx.klozik@intel.com> Reviewed-by: Radek Zetik <radekx.zetik@intel.com> Reviewed-by: Dino Simeon Madarang <dino.simeonx.madarang@intel.com> Reviewed-by: Brian Castelli <brian.castelli@spirent.com>
Diffstat (limited to 'docs/userguides')
-rw-r--r--docs/userguides/TCLServerProperties.pngbin11667 -> 0 bytes
-rw-r--r--docs/userguides/index.rst11
-rwxr-xr-xdocs/userguides/installation.rst76
-rwxr-xr-xdocs/userguides/quickstart.rst371
-rw-r--r--docs/userguides/trafficgen.rst218
5 files changed, 0 insertions, 676 deletions
diff --git a/docs/userguides/TCLServerProperties.png b/docs/userguides/TCLServerProperties.png
deleted file mode 100644
index 682de7c5..00000000
--- a/docs/userguides/TCLServerProperties.png
+++ /dev/null
Binary files differ
diff --git a/docs/userguides/index.rst b/docs/userguides/index.rst
deleted file mode 100644
index c796e6c3..00000000
--- a/docs/userguides/index.rst
+++ /dev/null
@@ -1,11 +0,0 @@
-******************************
-VSPERF Guides and Installation
-******************************
-
-.. toctree::
- :numbered:
- :maxdepth: 3
-
- quickstart.rst
- installation.rst
- trafficgen.rst
diff --git a/docs/userguides/installation.rst b/docs/userguides/installation.rst
deleted file mode 100755
index abd09cb4..00000000
--- a/docs/userguides/installation.rst
+++ /dev/null
@@ -1,76 +0,0 @@
-======================
-Installing vswitchperf
-======================
-
-The test suite requires Python 3.3 and relies on a number of other
-packages. These need to be installed for the test suite to function.
-
-Installation of required packages, preparation of Python 3 virtual
-environment and compilation of OVS, DPDK and QEMU is performed by
-script **systems/build_base_machine.sh**. It should be executed under
-user account, which will be used for vsperf execution.
-
-Please Note: Password-less sudo access must be configured for given
-user account before script is executed.
-
-Execution of installation script:
-
-.. code:: bash
-
- $ cd systems
- $ ./build_base_machine.sh
-
-Please note: you don't need to go into any of the systems subdirectories,
-simply run the top level **build_base_machine.sh**, your OS will be detected
-automatically.
-
-Currently supported operating systems are:
-
- - CentOS 7
- - Fedora 20
- - Fedora 21
- - Fedora 22
- - Ubuntu 14.04
-
-Script **build_base_machine.sh** will install all the vsperf dependencies
-in terms of system packages, Python 3.x and required Python modules.
-In case of CentOS 7 it will install Python 3.3 from an additional repository
-provided by Software Collections (`a link`_). Installation script will also
-use `virtualenv`_ to create a vsperf virtual environment, which is isolated
-from the default Python environment. This environment will reside
-in a directory called **vsperfenv** in $HOME.
-
-You will need to activate the virtual environment every time you start a
-new shell session. Its activation is specific to your OS:
-
-CentOS 7:
-
-.. code:: bash
-
- $ scl enable python33 bash
- $ cd $HOME/vsperfenv
- $ source bin/activate
-
-Fedora and Ubuntu:
-
-.. code:: bash
-
- $ cd $HOME/vsperfenv
- $ source bin/activate
-
-
---------------
-
-Working Behind a Proxy
-======================
-
-If you're behind a proxy, you'll likely want to configure this before
-running any of the above. For example:
-
- .. code:: bash
-
- export http_proxy=proxy.mycompany.com:123
- export https_proxy=proxy.mycompany.com:123
-
-.. _a link: http://www.softwarecollections.org/en/scls/rhscl/python33/
-.. _virtualenv: https://virtualenv.readthedocs.org/en/latest/
diff --git a/docs/userguides/quickstart.rst b/docs/userguides/quickstart.rst
deleted file mode 100755
index fd5c6779..00000000
--- a/docs/userguides/quickstart.rst
+++ /dev/null
@@ -1,371 +0,0 @@
-=============================
-Getting Started with 'vsperf'
-=============================
-
-Requirements
--------------
-
-VSPERF requires a traffic generators to run tests, automated traffic gen
-support in VSPERF includes:
-
-- IXIA traffic generator (IxNetwork hardware) and a machine that runs the IXIA
- client software.
-- Spirent traffic generator (TestCenter hardware chassis or TestCenter virtual
- in a VM) and a VM to run the Spirent Virtual Deployment Service image,
- formerly known as "Spirent LabServer".
-
-If you want to use another traffic generator, please select the Dummy generator
-option as shown in `Traffic generator instructions
-<http://artifacts.opnfv.org/vswitchperf/docs/userguides/trafficgen.html>`__
-
-Supported OSes include:
-
-* CentOS Linux release 7.1.1503 (Core) host.
-* Fedora 21 and 22.
-* Ubuntu 14.04
-
-vSwitch Requirements
---------------------
-
-The vSwitch must support Open Flow 1.3 or greater. VSPERF supports both:
-
-* OVS
-* OVS with DPDK
-
-VSPERF Installation
---------------------
-
-Follow the `installation instructions
-<http://artifacts.opnfv.org/vswitchperf/docs/userguides/installation.html>`__ to
-install.
-
-Traffic Generator Setup
------------------------
-Follow the `Traffic generator instructions
-<http://artifacts.opnfv.org/vswitchperf/docs/userguides/trafficgen.html>`__ to
-install and configure a suitable traffic generator.
-
-Cloning and building src dependencies
--------------------------------------
-
-In order to run VSPERF, you will need to download DPDK and OVS. You can
-do this manually and build them in a preferred location, OR you could
-use vswitchperf/src. The vswitchperf/src directory contains makefiles
-that will allow you to clone and build the libraries that VSPERF depends
-on, such as DPDK and OVS. To clone and build simply:
-
-.. code-block:: console
-
- $ cd src
- $ make
-
-VSPERF can be used with stock OVS (without DPDK support). When build
-is finished, the libraries are stored in src_vanilla directory.
-
-The 'make' builds all options in src:
-
-* Vanilla OVS
-* OVS with vhost_user as the guest access method (with DPDK support)
-* OVS with vhost_cuse s the guest access method (with DPDK support)
-
-The vhost_user build will reside in src/ovs/
-The vhost_cuse build will reside in vswitchperf/src_cuse
-The Vanilla OVS build will reside in vswitchperf/src_vanilla
-
-To delete a src subdirectory and its contents to allow you to re-clone simply
-use:
-
-.. code-block:: console
-
- $ make clobber
-
-Configure the ``./conf/10_custom.conf`` file
---------------------------------------------
-The ``10_custom.conf`` file is the configuration file that overrides
-default configurations in all the other configuration files in ``./conf``
-The supplied ``10_custom.conf`` file **MUST** be modified, as it contains
-configuration items for which there are no reasonable default values.
-
-The configuration items that can be added is not limited to the initial
-contents. Any configuration item mentioned in any .conf file in
-``./conf`` directory can be added and that item will be overridden by
-the custom configuration value.
-
-Using a custom settings file
-----------------------------
-
-If your ``10_custom.conf`` doesn't reside in the ``./conf`` directory
-of if you want to use an alternative configuration file, the file can
-be passed to ``vsperf`` via the ``--conf-file`` argument.
-
-.. code-block:: console
-
- $ ./vsperf --conf-file <path_to_custom_conf> ...
-
-Note that configuration passed in via the environment (``--load-env``)
-or via another command line argument will override both the default and
-your custom configuration files. This "priority hierarchy" can be
-described like so (1 = max priority):
-
-1. Command line arguments
-2. Environment variables
-3. Configuration file(s)
-
-vloop_vnf
----------
-vsperf uses a VM called vloop_vnf for looping traffic in the PVP and PVVP
-deployment scenarios. The image can be downloaded from
-`<http://artifacts.opnfv.org/>`__.
-
-.. code-block:: console
-
- $ wget http://artifacts.opnfv.org/vswitchperf/vloop-vnf-ubuntu-14.04_20151216.qcow2
-
-Alternatively you can use your own QEMU image.
-
---------------
-
-Executing tests
----------------
-
-Before running any tests make sure you have root permissions by adding
-the following line to /etc/sudoers:
-
-.. code-block:: console
-
- username ALL=(ALL) NOPASSWD: ALL
-
-username in the example above should be replaced with a real username.
-
-To list the available tests:
-
-.. code-block:: console
-
- $ ./vsperf --list
-
-To run a single test:
-
-.. code-block:: console
-
- $ ./vsperf $TESTNAME
-
-Where $TESTNAME is the name of the vsperf test you would like to run.
-
-To run a group of tests, for example all tests with a name containing
-'RFC2544':
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf --tests="RFC2544"
-
-To run all tests:
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf
-
-Some tests allow for configurable parameters, including test duration
-(in seconds) as well as packet sizes (in bytes).
-
-.. code:: bash
-
- $ ./vsperf --conf-file user_settings.py
- --tests RFC2544Tput
- --test-param "duration=10;pkt_sizes=128"
-
-For all available options, check out the help dialog:
-
-.. code-block:: console
-
- $ ./vsperf --help
-
-Executing Vanilla OVS tests
-----------------------------
-
-1. If needed, recompile src for all OVS variants
-
-.. code-block:: console
-
- $ cd src
- $ make distclean
- $ make
-
-2. Update your ''10_custom.conf'' file to use the appropriate variables
-for Vanilla OVS:
-
-.. code-block:: console
-
- VSWITCH = 'OvsVanilla'
- VSWITCH_VANILLA_PHY_PORT_NAMES = ['$PORT1', '$PORT1']
-
-Where $PORT1 and $PORT2 are the Linux interfaces you'd like to bind
-to the vswitch.
-
-3. Run test:
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>
-
-Please note if you don't want to configure Vanilla OVS through the
-configuration file, you can pass it as a CLI argument; BUT you must
-set the ports.
-
-.. code-block:: console
-
- $ ./vsperf --vswitch OvsVanilla
-
-
-Executing PVP and PVVP tests
-----------------------------
-To run tests using vhost-user as guest access method:
-
-1. Set VHOST_METHOD and VNF of your settings file to:
-
-.. code-block:: console
-
- VHOST_METHOD='user'
- VNF = 'QemuDpdkVhost'
-
-2. If needed, recompile src for all OVS variants
-
-.. code-block:: console
-
- $ cd src
- $ make distclean
- $ make
-
-3. Run test:
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf
-
-To run tests using vhost-cuse as guest access method:
-
-1. Set VHOST_METHOD and VNF of your settings file to:
-
-.. code-block:: console
-
- VHOST_METHOD='cuse'
- VNF = 'QemuDpdkVhostCuse'
-
-2. If needed, recompile src for all OVS variants
-
-.. code-block:: console
-
- $ cd src
- $ make distclean
- $ make
-
-3. Run test:
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf
-
-Executing PVP tests using Vanilla OVS
--------------------------------------
-To run tests using Vanilla OVS:
-
-1. Set the following variables:
-
-.. code-block:: console
-
- VSWITCH = 'OvsVanilla'
- VNF = 'QemuVirtioNet'
-
- VANILLA_TGEN_PORT1_IP = n.n.n.n
- VANILLA_TGEN_PORT1_MAC = nn:nn:nn:nn:nn:nn
-
- VANILLA_TGEN_PORT2_IP = n.n.n.n
- VANILLA_TGEN_PORT2_MAC = nn:nn:nn:nn:nn:nn
-
- VANILLA_BRIDGE_IP = n.n.n.n
-
- or use --test-param
-
- ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf
- --test-param "vanilla_tgen_tx_ip=n.n.n.n;
- vanilla_tgen_tx_mac=nn:nn:nn:nn:nn:nn"
-
-
-2. If needed, recompile src for all OVS variants
-
-.. code-block:: console
-
- $ cd src
- $ make distclean
- $ make
-
-3. Run test:
-
-.. code-block:: console
-
- $ ./vsperf --conf-file<path_to_custom_conf>/10_custom.conf
-
-Selection of loopback application for PVP and PVVP tests
---------------------------------------------------------
-To select loopback application, which will perform traffic forwarding
-inside VM, following configuration parameter should be configured:
-
-.. code-block:: console
-
- GUEST_LOOPBACK = ['testpmd', 'testpmd']
-
-or use --test-param
-
-.. code-block:: console
-
- $ ./vsperf --conf-file=<path_to_custom_conf>/10_custom.conf
- --test-param "guest_loopback=testpmd"
-
-Supported loopback applications are:
-
-.. code-block:: console
-
- 'testpmd' - testpmd from dpdk will be built and used
- 'l2fwd' - l2fwd module provided by Huawei will be built and used
- 'linux_bridge' - linux bridge will be configured
- 'buildin' - nothing will be configured by vsperf; VM image must
- ensure traffic forwarding between its interfaces
-
-Guest loopback application must be configured, otherwise traffic
-will not be forwarded by VM and testcases with PVP and PVVP deployments
-will fail. Guest loopback application is set to 'testpmd' by default.
-
-Code change verification by pylint
-----------------------------------
-Every developer participating in VSPERF project should run
-pylint before his python code is submitted for review. Project
-specific configuration for pylint is available at 'pylint.rc'.
-
-Example of manual pylint invocation:
-
-.. code-block:: console
-
- $ pylint --rcfile ./pylintrc ./vsperf
-
-GOTCHAs:
---------
-
-OVS with DPDK and QEMU
-~~~~~~~~~~~~~~~~~~~~~~~
-If you encounter the following error: "before (last 100 chars):
-'-path=/dev/hugepages,share=on: unable to map backing store for
-hugepages: Cannot allocate memory\r\n\r\n" with the PVP or PVVP
-deployment scenario, check the amount of hugepages on your system:
-
-.. code-block:: console
-
- $ cat /proc/meminfo | grep HugePages
-
-
-By default the vswitchd is launched with 1Gb of memory, to change
-this, modify --socket-mem parameter in conf/02_vswitch.conf to allocate
-an appropriate amount of memory:
-
-.. code-block:: console
-
- VSWITCHD_DPDK_ARGS = ['-c', '0x4', '-n', '4', '--socket-mem 1024,0']
-
diff --git a/docs/userguides/trafficgen.rst b/docs/userguides/trafficgen.rst
deleted file mode 100644
index f510a596..00000000
--- a/docs/userguides/trafficgen.rst
+++ /dev/null
@@ -1,218 +0,0 @@
-===========================
-'vsperf' Traffic Gen Guide
-===========================
-
-Overview
----------------------
-VSPERF supports the following traffic generators:
-
- * Dummy (DEFAULT): Allows you to use your own external
- traffic generator.
- * IXIA (IxNet and IxOS)
- * Spirent TestCenter
-
-To see the list of traffic gens from the cli:
-
-.. code-block:: console
-
- $ ./vsperf --list-trafficgens
-
-This guide provides the details of how to install
-and configure the various traffic generators.
-
-Background Information
-----------------------
-The traffic default configuration can be found in
-tools/pkt_gen/trafficgen/trafficgenhelper.py, and is configured as
-follows:
-
-.. code-block:: console
-
- TRAFFIC_DEFAULTS = {
- 'l2': {
- 'framesize': 64,
- 'srcmac': '00:00:00:00:00:00',
- 'dstmac': '00:00:00:00:00:00',
- 'srcport': 3000,
- 'dstport': 3001,
- },
- 'l3': {
- 'proto': 'tcp',
- 'srcip': '1.1.1.1',
- 'dstip': '90.90.90.90',
- },
- 'vlan': {
- 'enabled': False,
- 'id': 0,
- 'priority': 0,
- 'cfi': 0,
- },
- }
-
-The framesize paramter can be overridden from the configuration
-files by adding the following to your custom configuration file
-``10_custom.conf``:
-
-.. code-block:: console
-
- TRAFFICGEN_PKT_SIZES = (64, 128,)
-
-OR from the commandline:
-
-.. code-block:: console
-
- $ ./vsperf --test-param "pkt_sizes=x,y" $TESTNAME
-
-You can also modify the traffic transmission duration and the number
-of trials run by the traffic generator by extending the example
-commandline above to:
-
-.. code-block:: console
-
- $ ./vsperf --test-param "pkt_sizes=x,y;duration=10;rfc2455_trials=3" $TESTNAME
-
-Dummy Setup
-------------
-To select the Dummy generator please add the following to your
-custom configuration file ``10_custom.conf``.
-
-
-.. code-block:: console
-
- TRAFFICGEN = 'Dummy'
-
-OR run ``vsperf`` with the ``--trafficgen`` argument
-
-.. code-block:: console
-
- $ ./vsperf --trafficgen Dummy $TESTNAME
-
-Where $TESTNAME is the name of the vsperf test you would like to run.
-This will setup the vSwitch and the VNF (if one is part of your test)
-print the traffic configuration and prompt you to transmit traffic
-when the setup is complete.
-
-.. code-block:: console
-
- Please send 'continuous' traffic with the following stream config:
- 30mS, 90mpps, multistream False
- and the following flow config:
- {
- "flow_type": "port",
- "l3": {
- "srcip": "1.1.1.1",
- "proto": "tcp",
- "dstip": "90.90.90.90"
- },
- "traffic_type": "continuous",
- "multistream": 0,
- "bidir": "True",
- "vlan": {
- "cfi": 0,
- "priority": 0,
- "id": 0,
- "enabled": false
- },
- "frame_rate": 90,
- "l2": {
- "dstport": 3001,
- "srcport": 3000,
- "dstmac": "00:00:00:00:00:00",
- "srcmac": "00:00:00:00:00:00",
- "framesize": 64
- }
- }
- What was the result for 'frames tx'?
-
-When your traffic gen has completed traffic transmission and provided
-the results please input these at the vsperf prompt. vsperf will try
-to verify the input:
-
-.. code-block:: console
-
- Is '$input_value' correct?
-
-Please answer with y OR n.
-
-VPSERF will ask you for:
- * Result for 'frames tx'
- * Result for 'frames rx'
- * Result for 'min latency'
- * Result for 'max latency'
- * Result for 'avg latency'
-
-Finally vsperf will print out the results for your test and generate the
-appropriate logs and csv files.
-
-
-IXIA Setup
-----------
-
-On the CentOS 7 system
-~~~~~~~~~~~~~~~~~~~~~~
-
-You need to install IxNetworkTclClient$(VER\_NUM)Linux.bin.tgz.
-
-On the IXIA client software system
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-Find the IxNetwork TCL server app (start -> All Programs -> IXIA ->
-IxNetwork -> IxNetwork\_$(VER\_NUM) -> IxNetwork TCL Server)
-
-Right click on IxNetwork TCL Server, select properties - Under shortcut tab in
-the Target dialogue box make sure there is the argument "-tclport xxxx"
-where xxxx is your port number (take note of this port number you will
-need it for the 10\_custom.conf file).
-
-.. image:: TCLServerProperties.png
-
-Hit Ok and start the TCL server application
-
-Spirent Setup
--------------
-
-Spirent installation files and instructions are available on the
-Spirent support website at:
-
-http://support.spirent.com
-
-Select a version of Spirent TestCenter software to utilize. This example
-will use Spirent TestCenter v4.57 as an example. Substitute the appropriate
-version in place of 'v4.57' in the examples, below.
-
-On the CentOS 7 System
-~~~~~~~~~~~~~~~~~~~~~~
-
-Download and install the following:
-
-Spirent TestCenter Application, v4.57 for 64-bit Linux Client
-
-Spirent Virtual Deployment Service (VDS)
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-Spirent VDS is required for both TestCenter hardware and virtual
-chassis in the vsperf environment. For installation, select the version
-that matches the Spirent TestCenter Application version. For v4.57,
-the matching VDS version is 1.0.55. Download either the ova (VMware)
-or qcow2 (QEMU) image and create a VM with it. Initialize the VM
-according to Spirent installation instructions.
-
-Using Spirent TestCenter Virtual (STCv)
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-STCv is available in both ova (VMware) and qcow2 (QEMU) formats. For
-VMware, download:
-
-Spirent TestCenter Virtual Machine for VMware, v4.57 for Hypervisor - VMware ESX.ESXi
-
-Virtual test port performance is affected by the hypervisor configuration. For
-best practice results in deploying STCv, the following is suggested:
-
-- Create a single VM with two test ports rather than two VMs with one port each
-- Set STCv in DPDK mode
-- Give STCv 2*n + 1 cores, where n = the number of ports. For vsperf, cores = 5.
-- Turning off hyperthreading and pinning these cores will improve performance
-- Give STCv 2 GB of RAM
-
-To get the highest performance and accuracy, Spirent TestCenter hardware is
-recommended. vsperf can run with either stype test ports.