Vanilla_Multi_Queue: Add vanilla ovs multi-queue functionality
Adds multi-queue for vanilla OVS using virtio-net. TunTap ports will use multi_queue parameter when ports are created/deleted if guest nic queues are enabled and vswitch is ovs vanilla. Virtio net will now add guest nic queues to qemu command line if appropriate. Reworked multi-queue documentation to reflect these changes. Adds vhost net thread affinitization which is recommended when performing vanilla ovs multi-queue. Guests will require ethtool if using l2fwd or linux bridge as the loopback application when vanilla ovs multi-queue is enabled. Modified dpdk setting in vswitch conf to be better worded for separation from vanilla ovs multi-queue. Updated release and installation doc for new vloop image that includes required ethtool utility. JIRA: VSPERF-373 Change-Id: Idb550515190b1a93390308c11f54da368f962512 Signed-off-by: Christian Trautman <ctrautma@redhat.com>
Diffstat (limited to 'docs/userguide')
-rwxr-xr-xdocs/userguide/testusage.rst51
1 files changed, 32 insertions, 19 deletions
diff --git a/docs/userguide/testusage.rst b/docs/userguide/testusage.rst
index 9eeddc27..c55b5a2c 100755
--- a/docs/userguide/testusage.rst
+++ b/docs/userguide/testusage.rst
@@ -427,30 +427,25 @@ Multi-Queue Configuration
VSPerf currently supports multi-queue with the following limitations:
- 1. Execution of pvp/pvvp tests require testpmd as the loopback if multi-queue
- is enabled at the guest.
-
- 2. Requires QemuDpdkVhostUser as the vnf.
-
- 3. Requires switch to be set to OvsDpdkVhost.
-
- 4. Requires QEMU 2.5 or greater and any OVS version higher than 2.5. The
- default upstream package versions installed by VSPerf satisfy this
+ 1. Requires QEMU 2.5 or greater and any OVS version higher than 2.5. The
+ default upstream package versions installed by VSPerf satisfies this
requirement.
- 5. If using OVS versions 2.5.0 or less enable old style multi-queue as shown in
- the ''02_vswitch.conf'' file.
+ 2. Guest image must have ethtool utility installed if using l2fwd or linux
+ bridge inside guest for loopback.
+
+ 3. If using OVS versions 2.5.0 or less enable old style multi-queue as shown
+ in the ''02_vswitch.conf'' file.
.. code-block:: console
OVS_OLD_STYLE_MQ = True
-To enable multi-queue modify the ''02_vswitch.conf'' file to enable multi-queue
-on the switch.
+To enable multi-queue for dpdk modify the ''02_vswitch.conf'' file.
.. code-block:: console
- VSWITCH_MULTI_QUEUES = 2
+ VSWITCH_DPDK_MULTI_QUEUES = 2
**NOTE:** you should consider using the switch affinity to set a pmd cpu mask
that can optimize your performance. Consider the numa of the NIC in use if this
@@ -471,8 +466,12 @@ To enable multi-queue on the guest modify the ''04_vnf.conf'' file.
Enabling multi-queue at the guest will add multiple queues to each NIC port when
qemu launches the guest.
-Testpmd should be configured to take advantage of multi-queue on the guest. This
-can be done by modifying the ''04_vnf.conf'' file.
+In case of Vanilla OVS, multi-queue is enabled on the tuntap ports and nic
+queues will be enabled inside the guest with ethtool. Simply enabling the
+multi-queue on the guest is sufficient for Vanilla OVS multi-queue.
+
+Testpmd should be configured to take advantage of multi-queue on the guest if
+using DPDKVhostUser. This can be done by modifying the ''04_vnf.conf'' file.
.. code-block:: console
@@ -485,9 +484,23 @@ can be done by modifying the ''04_vnf.conf'' file.
**NOTE:** The guest SMP cores must be configured to allow for testpmd to use the
optimal number of cores to take advantage of the multiple guest queues.
-**NOTE:** For optimal performance guest SMPs should be on the same numa as the
-NIC in use if possible/applicable. Testpmd should be assigned at least
-(nb_cores +1) total cores with the cpu mask.
+In case of using Vanilla OVS and qemu virtio-net you can increase performance
+by binding vhost-net threads to cpus. This can be done by enabling the affinity
+in the ''04_vnf.conf'' file. This can be done to non multi-queue enabled
+configurations as well as there will be 2 vhost-net threads.
+
+ .. code-block:: console
+
+ VSWITCH_VHOST_NET_AFFINITIZATION = True
+
+ VSWITCH_VHOST_CPU_MAP = [4,5,8,11]
+
+**NOTE:** This method of binding would require a custom script in a real
+environment.
+
+**NOTE:** For optimal performance guest SMPs and/or vhost-net threads should be
+on the same numa as the NIC in use if possible/applicable. Testpmd should be
+assigned at least (nb_cores +1) total cores with the cpu mask.
Executing Packet Forwarding tests
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^