aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorRichard Elias <richardx.elias@intel.com>2018-01-08 10:05:01 +0000
committerRichard Elias <richardx.elias@intel.com>2018-01-18 10:23:41 +0000
commitec24483038a42432291d2ac332f772050d132c60 (patch)
tree3ee3f9d5a6fd71326f43adc5d2e1d8219e4afe49
parent9e4cea295062af44c57db6d1e40fc74e529b2868 (diff)
documentation: Traffic Capture methods
Created new chapter on Traffic Capture and added short descriptions and explanation for each of the three methods currently supported by VSPERF. Subchapters include Traffic Capture in the VM, Traffic for testing NICs with Hardware acceleration and Traffic Capture on the Trraffic Generator. JIRA: VSPERF-556 Change-Id: I280c54aa73961e0bbb61b40e8fe476bd3e92ff7d Signed-off-by: Richard Elias <richardx.elias@intel.com> Reviewed-by: Martin Klozik <martinx.klozik@intel.com> Reviewed-by: Al Morton <acmorton@att.com> Reviewed-by: Christian Trautman <ctrautma@redhat.com> Reviewed-by: Sridhar Rao <sridhar.rao@spirent.com> Reviewed-by: Trevor Cooper <trevor.cooper@intel.com>
-rw-r--r--docs/testing/user/userguide/index.rst1
-rw-r--r--docs/testing/user/userguide/trafficcapture.rst297
2 files changed, 298 insertions, 0 deletions
diff --git a/docs/testing/user/userguide/index.rst b/docs/testing/user/userguide/index.rst
index 64d91657..350fbe54 100644
--- a/docs/testing/user/userguide/index.rst
+++ b/docs/testing/user/userguide/index.rst
@@ -16,5 +16,6 @@ VSPERF Test Guide
./testusage.rst
./teststeps.rst
./integration.rst
+ ./trafficcapture.rst
./yardstick.rst
./testlist.rst
diff --git a/docs/testing/user/userguide/trafficcapture.rst b/docs/testing/user/userguide/trafficcapture.rst
new file mode 100644
index 00000000..fa09bfed
--- /dev/null
+++ b/docs/testing/user/userguide/trafficcapture.rst
@@ -0,0 +1,297 @@
+Traffic Capture
+---------------
+
+Tha ability to capture traffic at multiple points of the system is crucial to
+many of the functional tests. It allows the verification of functionality for
+both the vSwitch and the NICs using hardware acceleration for packet
+manipulation and modification.
+
+There are three different methods of traffic capture supported by VSPERF.
+Detailed descriptions of these methods as well as their pros and cons can be
+found in the following chapters.
+
+Traffic Capture inside of a VM
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+This method uses the standard PVP scenario, in which vSwitch first processes
+and modifies the packet before forwarding it to the VM. Inside of the VM we
+capture the traffic using **tcpdump** or a similiar technique. The capture
+information is the used to verify the expected modifications to the packet done
+by vSwitch.
+
+.. code-block:: console
+
+ _
+ +--------------------------------------------------+ |
+ | | |
+ | +------------------------------------------+ | |
+ | | Traffic capture and Packet Forwarding | | |
+ | +------------------------------------------+ | |
+ | ^ : | |
+ | | | | | Guest
+ | : v | |
+ | +---------------+ +---------------+ | |
+ | | logical port 0| | logical port 1| | |
+ +---+---------------+----------+---------------+---+ _|
+ ^ :
+ | |
+ : v _
+ +---+---------------+----------+---------------+---+ |
+ | | logical port 0| | logical port 1| | |
+ | +---------------+ +---------------+ | |
+ | ^ : | |
+ | | | | | Host
+ | : v | |
+ | +--------------+ +--------------+ | |
+ | | phy port | vSwitch | phy port | | |
+ +---+--------------+------------+--------------+---+ _|
+ ^ :
+ | |
+ : v
+ +--------------------------------------------------+
+ | |
+ | traffic generator |
+ | |
+ +--------------------------------------------------+
+
+PROS:
+
+- supports testing with all traffic generators
+- easy to use and implement into test
+- allows testing hardware offloading on the ingress side
+
+CONS:
+
+- does not allow testing hardware offloading on the egress side
+
+An example of Traffic Capture in VM test:
+
+.. code-block:: python
+
+ # Capture Example 1 - Traffic capture inside VM (PVP scenario)
+ # This TestCase will modify VLAN ID set by the traffic generator to the new value.
+ # Correct VLAN ID settings is verified by inspection of captured frames.
+ {
+ Name: capture_pvp_modify_vid,
+ Deployment: pvp,
+ Description: Test and verify VLAN ID modification by Open vSwitch,
+ Parameters : {
+ VSWITCH : OvsDpdkVhost, # works also for Vanilla OVS
+ TRAFFICGEN_DURATION : 5,
+ TRAFFIC : {
+ traffic_type : rfc2544_continuous,
+ frame_rate : 100,
+ 'vlan': {
+ 'enabled': True,
+ 'id': 8,
+ 'priority': 1,
+ 'cfi': 0,
+ },
+ },
+ GUEST_LOOPBACK : ['linux_bridge'],
+ },
+ TestSteps: [
+ # replace original flows with vlan ID modification
+ ['!vswitch', 'add_flow', 'br0', {'in_port': '1', 'actions': ['mod_vlan_vid:4','output:3']}],
+ ['!vswitch', 'add_flow', 'br0', {'in_port': '2', 'actions': ['mod_vlan_vid:4','output:4']}],
+ ['vswitch', 'dump_flows', 'br0'],
+ # verify that received frames have modified vlan ID
+ ['VNF0', 'execute_and_wait', 'tcpdump -i eth0 -c 5 -w dump.pcap vlan 4 &'],
+ ['trafficgen', 'send_traffic',{}],
+ ['!VNF0', 'execute_and_wait', 'tcpdump -qer dump.pcap vlan 4 2>/dev/null | wc -l','|^(\d+)$'],
+ ['tools', 'assert', '#STEP[-1][0] == 5'],
+ ],
+ },
+
+Traffic Capture for testing NICs with HW offloading/acceleration
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+The NIC with hardware acceleration/offloading is inserted as an additional card
+into the server. Two ports on this card are then connected together using
+a patch cable as shown in the diagram. Only a single port of the tested NIC is
+setup with DPDK acceleration, while the other is handled by the Linux Ip stack
+allowing for traffic capture. The two NICs are then connected by vSwitch so the
+original card can forward the processed packets to the traffic generator. The
+ports handled by Linux IP stack allow for capturing packets, which are then
+analyzed for changes done by both the vSwitch and the NIC with hardware
+acceleration.
+
+.. code-block:: console
+
+ _
+ +------------------------------------------------+ |
+ | | |
+ | +----------------------------------------+ | |
+ | | vSwitch | | |
+ | | +----------------------------------+ | | |
+ | | | | | | |
+ | | | +------------------+ | | | |
+ | | | | | v | | |
+ | +----------------------------------------+ | | Device under Test
+ | ^ | ^ | | |
+ | | | | | | |
+ | | v | v | |
+ | +--------------+ +--------------+ | |
+ | | | | NIC w HW acc | | |
+ | | phy ports | | phy ports | | |
+ +---+--------------+----------+--------------+---+ _|
+ ^ : ^ :
+ | | | |
+ | | +-------+
+ : v Patch Cable
+ +------------------------------------------------+
+ | |
+ | traffic generator |
+ | |
+ +------------------------------------------------+
+
+PROS:
+
+- allows testing hardware offloading on both the ingress and egress side
+- supports testing with all traffic generators
+- relatively easy to use and implement into tests
+
+CONS:
+
+- a more complex setup with two cards
+- if the tested card only has one port, an additional card is needed
+
+An example of Traffic Capture for testing NICs with HW offloading test:
+
+.. code-block:: python
+
+ # Capture Example 2 - Setup with 2 NICs, where traffic is captured after it is
+ # processed by NIC under the test (2nd NIC). See documentation for further details.
+ # This TestCase will strip VLAN headers from traffic sent by the traffic generator.
+ # The removal of VLAN headers is verified by inspection of captured frames.
+ #
+ # NOTE: This setup expects a DUT with two NICs with two ports each. First NIC is
+ # connected to the traffic generator (standard VSPERF setup). Ports of a second NIC
+ # are interconnected by a patch cable. PCI addresses of all four ports have to be
+ # properly configured in the WHITELIST_NICS parameter.
+ {
+ Name: capture_p2p2p_strip_vlan_ovs,
+ Deployment: clean,
+ Description: P2P Continuous Stream,
+ Parameters : {
+ _CAPTURE_P2P2P_OVS_ACTION : 'strip_vlan',
+ TRAFFIC : {
+ bidir : False,
+ traffic_type : rfc2544_continuous,
+ frame_rate : 100,
+ 'l2': {
+ 'srcmac': ca:fe:00:00:00:00,
+ 'dstmac': 00:00:00:00:00:01
+ },
+ 'vlan': {
+ 'enabled': True,
+ 'id': 8,
+ 'priority': 1,
+ 'cfi': 0,
+ },
+ },
+ # suppress DPDK configuration, so physical interfaces are not bound to DPDK driver
+ 'WHITELIST_NICS' : [],
+ 'NICS' : [],
+ },
+ TestSteps: _CAPTURE_P2P2P_SETUP + [
+ # capture traffic after processing by NIC under the test (after possible egress HW offloading)
+ ['tools', 'exec_shell_background', 'tcpdump -i [2][device] -c 5 -w capture.pcap '
+ 'ether src [l2][srcmac]'],
+ ['trafficgen', 'send_traffic', {}],
+ ['vswitch', 'dump_flows', 'br0'],
+ ['vswitch', 'dump_flows', 'br1'],
+ # there must be 5 captured frames...
+ ['tools', 'exec_shell', 'tcpdump -r capture.pcap | wc -l', '|^(\d+)$'],
+ ['tools', 'assert', '#STEP[-1][0] == 5'],
+ # ...but no vlan headers
+ ['tools', 'exec_shell', 'tcpdump -r capture.pcap vlan | wc -l', '|^(\d+)$'],
+ ['tools', 'assert', '#STEP[-1][0] == 0'],
+ ],
+ },
+
+
+Traffic Capture on the Traffic Generator
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Using the functionality of the Traffic generator makes it possible to configure
+Traffic Capture on both it's ports. With Traffic Capture enabled, VSPERF
+instructs the Traffic Generator to automatically export captured data into
+a pcap file. The captured packets are then sent to VSPERF for analysis and
+verification, monitoring any changes done by both vSwitch and the NICs.
+
+Vsperf currently only supports this functionality with the **T-Rex** generator.
+
+.. code-block:: console
+
+ _
+ +--------------------------------------------------+ |
+ | | |
+ | +--------------------------+ | |
+ | | | | |
+ | | v | | Host
+ | +--------------+ +--------------+ | |
+ | | phy port | vSwitch | phy port | | |
+ +---+--------------+------------+--------------+---+ _|
+ ^ :
+ | |
+ : v
+ +--------------------------------------------------+
+ | |
+ | traffic generator |
+ | |
+ +--------------------------------------------------+
+
+PROS:
+
+- allows testing hardware offloading on both the ingress and egress side
+- does not require an additional NIC
+
+CONS:
+
+- currently only supported by **T-Rex** traffic generator
+
+An example Traffic Capture on the Traffic Generator test:
+
+.. code-block:: python
+
+
+ # Capture Example 3 - Traffic capture by traffic generator.
+ # This TestCase uses OVS flow to add VLAN tag with given ID into every
+ # frame send by traffic generator. Correct frame modificaiton is verified by
+ # inspection of packet capture received by T-Rex.
+ {
+ Name: capture_p2p_add_vlan_ovs_trex,
+ Deployment: clean,
+ Description: OVS: Test VLAN tag modification and verify it by traffic capture,
+ vSwitch : OvsDpdkVhost, # works also for Vanilla OVS
+ Parameters : {
+ TRAFFICGEN : Trex,
+ TRAFFICGEN_DURATION : 5,
+ TRAFFIC : {
+ traffic_type : rfc2544_continuous,
+ frame_rate : 100,
+ # enable capture of five RX frames
+ 'capture': {
+ 'enabled': True,
+ 'tx_ports' : [],
+ 'rx_ports' : [1],
+ 'count' : 5,
+ },
+ },
+ },
+ TestSteps : STEP_VSWITCH_P2P_INIT + [
+ # replace standard L2 flows by flows, which will add VLAN tag with ID 3
+ ['!vswitch', 'add_flow', 'int_br0', {'in_port': '1', 'actions': ['mod_vlan_vid:3','output:2']}],
+ ['!vswitch', 'add_flow', 'int_br0', {'in_port': '2', 'actions': ['mod_vlan_vid:3','output:1']}],
+ ['vswitch', 'dump_flows', 'int_br0'],
+ ['trafficgen', 'send_traffic', {}],
+ ['trafficgen', 'get_results'],
+ # verify that captured frames have vlan tag with ID 3
+ ['tools', 'exec_shell', 'tcpdump -qer /#STEP[-1][0][capture_rx] vlan 3 '
+ '2>/dev/null | wc -l', '|^(\d+)$'],
+ # number of received frames with expected VLAN id must match the number of captured frames
+ ['tools', 'assert', '#STEP[-1][0] == 5'],
+ ] + STEP_VSWITCH_P2P_FINIT,
+ },
+