aboutsummaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
Diffstat (limited to 'docs')
-rw-r--r--docs/configguide/index.rst1
-rw-r--r--[-rwxr-xr-x]docs/configguide/installation.rst184
-rw-r--r--docs/configguide/trafficgen.rst13
-rw-r--r--docs/configguide/upgrade.rst189
-rw-r--r--[-rwxr-xr-x]docs/design/index.rst0
-rw-r--r--[-rwxr-xr-x]docs/design/vswitchperf_design.rst9
-rw-r--r--[-rwxr-xr-x]docs/index.rst4
-rw-r--r--[-rwxr-xr-x]docs/msc/factory_and_loader.msc0
-rw-r--r--[-rwxr-xr-x]docs/msc/traffic_controller.msc0
-rw-r--r--[-rwxr-xr-x]docs/msc/vsperf.msc0
-rw-r--r--[-rwxr-xr-x]docs/requirements/ietf_draft/draft-ietf-bmwg-vswitch-opnfv-01.xml0
-rw-r--r--[-rwxr-xr-x]docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-00.xml0
-rw-r--r--[-rwxr-xr-x]docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-01.xml0
-rw-r--r--[-rwxr-xr-x]docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-02.xml0
-rw-r--r--[-rwxr-xr-x]docs/requirements/vm2vm_alternative_benchmark.pngbin104244 -> 104244 bytes
-rw-r--r--[-rwxr-xr-x]docs/requirements/vm2vm_benchmark.pngbin80797 -> 80797 bytes
-rw-r--r--[-rwxr-xr-x]docs/requirements/vm2vm_hypervisor_benchmark.pngbin122975 -> 122975 bytes
-rw-r--r--[-rwxr-xr-x]docs/requirements/vm2vm_virtual_interface_benchmark.pngbin99544 -> 99544 bytes
-rw-r--r--[-rwxr-xr-x]docs/userguide/integration.rst0
-rw-r--r--[-rwxr-xr-x]docs/userguide/testusage.rst0
-rw-r--r--[-rwxr-xr-x]docs/userguide/yardstick.rst0
21 files changed, 336 insertions, 64 deletions
diff --git a/docs/configguide/index.rst b/docs/configguide/index.rst
index c9bdccf7..b4c8575e 100644
--- a/docs/configguide/index.rst
+++ b/docs/configguide/index.rst
@@ -11,4 +11,5 @@ VSPERF Installation Guide
:maxdepth: 3
installation.rst
+ upgrade.rst
trafficgen.rst
diff --git a/docs/configguide/installation.rst b/docs/configguide/installation.rst
index 5010aefd..ed414a8b 100755..100644
--- a/docs/configguide/installation.rst
+++ b/docs/configguide/installation.rst
@@ -6,10 +6,43 @@
Installing vswitchperf
======================
+Downloading vswitchperf
+-----------------------
+
+The vswitchperf can be downloaded from its official git repository, which is
+hosted by OPNFV. It is necessary to install a ``git`` at your DUT before downloading
+vswitchperf. Installation of ``git`` is specific to the packaging system used by
+Linux OS installed at DUT.
+
+Example of installation of GIT package and its dependencies:
+
+* in case of OS based on RedHat Linux:
+
+ .. code:: bash
+
+ sudo yum install git
+
+
+* in case of Ubuntu or Debian:
+
+ .. code:: bash
+
+ sudo apt-get install git
+
+After the ``git`` is successfully installed at DUT, then vswitchperf can be downloaded
+as follows:
+
+.. code:: bash
+
+ git clone http://git.opnfv.org/vswitchperf
+
+The last command will create a directory ``vswitchperf`` with a local copy of vswitchperf
+repository.
+
Supported Operating Systems
---------------------------
-* CentOS 7
+* CentOS 7.3
* Fedora 20
* Fedora 21
* Fedora 22
@@ -21,72 +54,94 @@ Supported Operating Systems
Supported vSwitches
-------------------
+
The vSwitch must support Open Flow 1.3 or greater.
-* OVS (built from source).
-* OVS with DPDK (built from source).
+* Open vSwitch
+* Open vSwitch with DPDK support
+* TestPMD application from DPDK (supports p2p and pvp scenarios)
Supported Hypervisors
---------------------
-* Qemu version 2.3 or greater.
+* Qemu version 2.3 or greater (version 2.5.0 is recommended)
-Available VNFs
+Supported VNFs
--------------
-A simple VNF that forwards traffic through a VM, using:
+
+In theory, it is possible to use any VNF image, which is compatible
+with supported hypervisor. However such VNF must ensure, that appropriate
+number of network interfaces is configured and that traffic is properly
+forwarded among them. For new vswitchperf users it is recommended to start
+with official vloop-vnf_ image, which is maintained by vswitchperf community.
+
+.. _vloop-vnf:
+
+vloop-vnf
+=========
+
+The official VM image is called vloop-vnf and it is available for free download
+from OPNFV artifactory. This image is based on Linux Ubuntu distribution and it
+supports following applications for traffic forwarding:
* DPDK testpmd
* Linux Bridge
* Custom l2fwd module
-The official VM image is called vloop-vnf and it is available for free
-download at OPNFV website.
+The vloop-vnf can be downloaded to DUT, for example by ``wget``:
+
+ .. code:: bash
+
+ wget http://artifacts.opnfv.org/vswitchperf/vnf/vloop-vnf-ubuntu-14.04_20160823.qcow2
-vloop-vnf changelog:
-====================
+**NOTE:** In case that ``wget`` is not installed at your DUT, you could install it at RPM
+based system by ``sudo yum install wget`` or at DEB based system by ``sudo apt-get install
+wget``.
-* `vloop-vnf-ubuntu-14.04_20160823`_
+Changelog of vloop-vnf:
- * ethtool installed
- * only 1 NIC is configured by default to speed up boot with 1 NIC setup
- * security updates applied
+ * `vloop-vnf-ubuntu-14.04_20160823`_
-* `vloop-vnf-ubuntu-14.04_20160804`_
+ * ethtool installed
+ * only 1 NIC is configured by default to speed up boot with 1 NIC setup
+ * security updates applied
- * Linux kernel 4.4.0 installed
- * libnuma-dev installed
- * security updates applied
+ * `vloop-vnf-ubuntu-14.04_20160804`_
-* `vloop-vnf-ubuntu-14.04_20160303`_
+ * Linux kernel 4.4.0 installed
+ * libnuma-dev installed
+ * security updates applied
- * snmpd service is disabled by default to avoid error messages during VM boot
- * security updates applied
+ * `vloop-vnf-ubuntu-14.04_20160303`_
-* `vloop-vnf-ubuntu-14.04_20151216`_
+ * snmpd service is disabled by default to avoid error messages during VM boot
+ * security updates applied
- * version with development tools required for build of DPDK and l2fwd
+ * `vloop-vnf-ubuntu-14.04_20151216`_
-Other Requirements
-------------------
-The test suite requires Python 3.3 and relies on a number of other
-packages. These need to be installed for the test suite to function.
+ * version with development tools required for build of DPDK and l2fwd
+
+Installation
+------------
+
+The test suite requires Python 3.3 or newer and relies on a number of other
+system and python packages. These need to be installed for the test suite
+to function.
Installation of required packages, preparation of Python 3 virtual
environment and compilation of OVS, DPDK and QEMU is performed by
script **systems/build_base_machine.sh**. It should be executed under
user account, which will be used for vsperf execution.
-**Please Note**: Password-less sudo access must be configured for given
+**NOTE:** Password-less sudo access must be configured for given
user account before script is executed.
-Execution of installation script:
-
.. code:: bash
$ cd systems
$ ./build_base_machine.sh
-**Please Note**: you don't need to go into any of the systems subdirectories,
+**NOTE:** you don't need to go into any of the systems subdirectories,
simply run the top level **build_base_machine.sh**, your OS will be detected
automatically.
@@ -96,52 +151,65 @@ In case of CentOS 7 or RHEL it will install Python 3.3 from an additional
repository provided by Software Collections (`a link`_). Installation script
will also use `virtualenv`_ to create a vsperf virtual environment, which is
isolated from the default Python environment. This environment will reside in a
-directory called **vsperfenv** in $HOME.
+directory called **vsperfenv** in $HOME. It will ensure, that system wide Python
+installation is not modified or broken by VSPERF installation. The complete list
+of Python packages installed inside virtualenv can be found at file
+``requirements.txt``, which is located at vswitchperf repository.
-**Please Note**: For RHEL 7.3 Enterprise OVS Vanilla is not built from upstream
-source due to kernel incompatibilities. Please see the instructions in the
-vswitchperf_design document for details on configuring OVS Vanilla for binary
-package usage.
+**NOTE:** For RHEL 7.3 Enterprise and CentOS 7.3 OVS Vanilla is not
+built from upstream source due to kernel incompatibilities. Please see the
+instructions in the vswitchperf_design document for details on configuring
+OVS Vanilla for binary package usage.
+
+Using vswitchperf
+-----------------
You will need to activate the virtual environment every time you start a
new shell session. Its activation is specific to your OS:
-CentOS 7 and RHEL
-=================
+* CentOS 7 and RHEL
-.. code:: bash
+ .. code:: bash
- $ scl enable python33 bash
- $ cd $HOME/vsperfenv
- $ source bin/activate
+ $ scl enable python33 bash
+ $ source $HOME/vsperfenv/bin/activate
-Fedora and Ubuntu
-=================
+* Fedora and Ubuntu
-.. code:: bash
+ .. code:: bash
- $ cd $HOME/vsperfenv
- $ source bin/activate
+ $ source $HOME/vsperfenv/bin/activate
+
+After the virtual environment is configued, then VSPERF can be used.
+For example:
+
+ .. code:: bash
+
+ (vsperfenv) $ cd vswitchperf
+ (vsperfenv) $ ./vsperf --help
Gotcha
-^^^^^^
+======
+
+In case you will see following error during environment activation:
+
.. code:: bash
- $ source bin/activate
+ $ source $HOME/vsperfenv/bin/activate
Badly placed ()'s.
-Check what type of shell you are using
+then check what type of shell you are using:
.. code:: bash
- echo $shell
+ $ echo $SHELL
/bin/tcsh
See what scripts are available in $HOME/vsperfenv/bin
.. code:: bash
- $ ls bin/
+ $ ls $HOME/vsperfenv/bin/
activate activate.csh activate.fish activate_this.py
source the appropriate script
@@ -195,11 +263,11 @@ your configuration in the ``02_vswitch.conf`` file.
'dpdk-socket-mem' : '1024,1024',
}
-Note: Option VSWITCHD_DPDK_ARGS is used for vswitchd, which supports --dpdk
-parameter. In recent vswitchd versions, option VSWITCHD_DPDK_CONFIG will be
-used to configure vswitchd via ovs-vsctl calls.
+**NOTE:** Option ``VSWITCHD_DPDK_ARGS`` is used for vswitchd, which supports ``--dpdk``
+parameter. In recent vswitchd versions, option ``VSWITCHD_DPDK_CONFIG`` is
+used to configure vswitchd via ``ovs-vsctl`` calls.
-With the --socket-mem argument set to use 1 hugepage on the specified sockets as
+With the ``--socket-mem`` argument set to use 1 hugepage on the specified sockets as
seen above, the configuration will need 10 hugepages total to run all tests
within vsperf if the pagesize is set correctly to 1GB.
@@ -207,7 +275,7 @@ VSPerf will verify hugepage amounts are free before executing test
environments. In case of hugepage amounts not being free, test initialization
will fail and testing will stop.
-**Please Note**: In some instances on a test failure dpdk resources may not
+**NOTE:** In some instances on a test failure dpdk resources may not
release hugepages used in dpdk configuration. It is recommended to configure a
few extra hugepages to prevent a false detection by VSPerf that not enough free
hugepages are available to execute the test environment. Normally dpdk would use
@@ -227,6 +295,6 @@ You can review your hugepage amounts by executing the following command
cat /proc/meminfo | grep Huge
If no hugepages are available vsperf will try to automatically allocate some.
-Allocation is controlled by HUGEPAGE_RAM_ALLOCATION configuration parameter in
+Allocation is controlled by ``HUGEPAGE_RAM_ALLOCATION`` configuration parameter in
``02_vswitch.conf`` file. Default is 2GB, resulting in either 2 1GB hugepages
or 1024 2MB hugepages.
diff --git a/docs/configguide/trafficgen.rst b/docs/configguide/trafficgen.rst
index 5190bc8e..b66a1787 100644
--- a/docs/configguide/trafficgen.rst
+++ b/docs/configguide/trafficgen.rst
@@ -516,6 +516,19 @@ Each value modifies the behavior of rfc 2544 throughput testing. Refer to your
Xena documentation to understand the behavior changes in modifying these
values.
+Continuous Traffic Testing
+~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Xena continuous traffic by default does a 3 second learning preemption to allow
+the DUT to receive learning packets before a continuous test is performed. If
+a custom test case requires this learning be disabled, you can disable the option
+or modify the length of the learning by modifying the following settings.
+
+.. code-block:: console
+
+ TRAFFICGEN_XENA_CONT_PORT_LEARNING_ENABLED = False
+ TRAFFICGEN_XENA_CONT_PORT_LEARNING_DURATION = 3
+
MoonGen
-------
diff --git a/docs/configguide/upgrade.rst b/docs/configguide/upgrade.rst
new file mode 100644
index 00000000..3a970c6a
--- /dev/null
+++ b/docs/configguide/upgrade.rst
@@ -0,0 +1,189 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International License.
+.. http://creativecommons.org/licenses/by/4.0
+.. (c) OPNFV, Intel Corporation, AT&T and others.
+
+=====================
+Upgrading vswitchperf
+=====================
+
+Generic
+-------
+
+In case, that VSPERF is cloned from git repository, then it is easy to
+upgrade it to the newest stable version or to the development version.
+
+You could get a list of stable releases by ``git`` command. It is necessary
+to update local git repository first.
+
+**NOTE:** Git commands must be executed from directory, where VSPERF repository
+was cloned, e.g. ``vswitchperf``.
+
+Update of local git repository:
+
+.. code:: bash
+
+ $ git pull
+
+List of stable releases:
+
+.. code:: bash
+
+ $ git tag
+
+ brahmaputra.1.0
+ colorado.1.0
+ colorado.2.0
+ colorado.3.0
+ danube.1.0
+
+You could select which stable release should be used. For example, select ``danube.1.0``:
+
+.. code:: bash
+
+ $ git checkout danube.1.0
+
+
+Development version of VSPERF can be selected by:
+
+.. code:: bash
+
+ $ git checkout master
+
+Colorado to Danube upgrade notes
+--------------------------------
+
+Obsoleted features
+~~~~~~~~~~~~~~~~~~
+
+Support of vHost Cuse interface has been removed in Danube release. It means,
+that it is not possible to select ``QemuDpdkVhostCuse`` as a VNF anymore. Option
+``QemuDpdkVhostUser`` should be used instead. Please check you configuration files
+and definition of your testcases for any occurrence of:
+
+.. code:: python
+
+ VNF = "QemuDpdkVhostCuse"
+
+or
+
+.. code:: python
+
+ "VNF" : "QemuDpdkVhostCuse"
+
+In case that ``QemuDpdkVhostCuse`` is found, it must be modified to ``QemuDpdkVhostUser``.
+
+**NOTE:** In case that execution of VSPERF is automated by scripts (e.g. for
+CI purposes), then these scripts must be checked and updated too. It means,
+that any occurrence of:
+
+.. code:: bash
+
+ ./vsperf --vnf QemuDpdkVhostCuse
+
+must be updated to:
+
+.. code:: bash
+
+ ./vsperf --vnf QemuDpdkVhostUser
+
+Configuration
+~~~~~~~~~~~~~
+
+Several configuration changes were introduced during Danube release. The most
+important changes are discussed below.
+
+Paths to DPDK, OVS and QEMU
+===========================
+
+VSPERF uses external tools for proper testcase execution. Thus it is important
+to properly configure paths to these tools. In case that tools are installed
+by installation scripts and are located inside ``./src`` directory inside
+VSPERF home, then no changes are needed. On the other hand, if path settings
+was changed by custom configuration file, then it is required to update configuration
+accordingly. Please check your configuration files for following configuration
+options:
+
+.. code:: bash
+
+ OVS_DIR
+ OVS_DIR_VANILLA
+ OVS_DIR_USER
+ OVS_DIR_CUSE
+
+ RTE_SDK_USER
+ RTE_SDK_CUSE
+
+ QEMU_DIR
+ QEMU_DIR_USER
+ QEMU_DIR_CUSE
+ QEMU_BIN
+
+In case that any of these options is defined, then configuration must be updated.
+All paths to the tools are now stored inside ``PATHS`` dictionary. Please
+refer to the paths-documentation_ and update your configuration where necessary.
+
+.. _paths-documentation: http://artifacts.opnfv.org/vswitchperf/docs/index.html#configuration-of-paths-dictionary
+
+Configuration change via CLI
+============================
+
+In previous releases it was possible to modify selected configuration options
+(mostly VNF specific) via command line interface, i.e. by ``--test-params``
+argument. This concept has been generalized in Danube release and it is
+possible to modify any configuration parameter via CLI or via **Parameters**
+section of the testcase definition. Old configuration options were obsoleted
+and it is required to specify configuration parameter name in the same form
+as it is defined inside configuration file, i.e. in uppercase. Please
+refer to the overriding-parameters-documentation_ for additional details.
+
+**NOTE:** In case that execution of VSPERF is automated by scripts (e.g. for
+CI purposes), then these scripts must be checked and updated too. It means,
+that any occurrence of
+
+.. code:: bash
+
+ guest_loopback
+ vanilla_tgen_port1_ip
+ vanilla_tgen_port1_mac
+ vanilla_tgen_port2_ip
+ vanilla_tgen_port2_mac
+ tunnel_type
+
+shall be changed to the uppercase form and data type of entered values must
+match to data types of original values from configuration files.
+
+In case that ``guest_nic1_name`` or ``guest_nic2_name`` is changed,
+then new dictionary ``GUEST_NICS`` must be modified accordingly.
+Please see guest-configuration_ and ``conf/04_vnf.conf`` for additional
+details.
+
+.. _overriding-parameters-documentation: http://artifacts.opnfv.org/vswitchperf/docs/index.html#overriding-values-defined-in-configuration-files
+.. _guest-configuration: http://artifacts.opnfv.org/vswitchperf/docs/index.html#configuration-of-guest-options
+
+Traffic configuration via CLI
+=============================
+
+In previous releases it was possible to modify selected attributes of generated
+traffic via command line interface. This concept has been enhanced in Danube
+release and it is now possible to modify all traffic specific options via
+CLI or by ``TRAFFIC`` dictionary in configuration file. Detailed description
+is available at configuration-of-traffic-dictionary_ section of documentation.
+
+Please check your automated scripts for VSPERF execution for following CLI
+parameters and update them according to the documentation:
+
+.. code:: bash
+
+ bidir
+ duration
+ frame_rate
+ iload
+ lossrate
+ multistream
+ pkt_sizes
+ pre-installed_flows
+ rfc2544_tests
+ stream_type
+ traffic_type
+
+.. _configuration-of-traffic-dictionary: http://artifacts.opnfv.org/vswitchperf/docs/index.html#configuration-of-traffic-dictionary
diff --git a/docs/design/index.rst b/docs/design/index.rst
index a8a076f4..a8a076f4 100755..100644
--- a/docs/design/index.rst
+++ b/docs/design/index.rst
diff --git a/docs/design/vswitchperf_design.rst b/docs/design/vswitchperf_design.rst
index 96b97631..bf82f9b8 100755..100644
--- a/docs/design/vswitchperf_design.rst
+++ b/docs/design/vswitchperf_design.rst
@@ -314,10 +314,11 @@ Detailed description of ``TRAFFIC`` dictionary items follows:
of selected transport protocol
Default value: "L4".
'pre_installed_flows'
- - Pre-installed flows is an extension of the multistream"
- feature. If multistream is disabled, then pre-installed
- flows will be ignored. It defines if stream specific flows
- will be inserted into OVS or not.
+ - Pre-installed flows is an extension of the "multistream"
+ feature. If enabled, it will implicitly insert a flow
+ for each stream. If multistream is disabled, then
+ pre-installed flows will be ignored.
+ Note: It is supported only for p2p deployment scenario.
Data type: str
Supported values:
"Yes" - flows will be inserted into OVS
diff --git a/docs/index.rst b/docs/index.rst
index 37e0c43f..bce2aa61 100755..100644
--- a/docs/index.rst
+++ b/docs/index.rst
@@ -17,7 +17,8 @@ Performance and Test group and its associated projects, as part of OPNFV
Platform and VNF level testing and validation.
* Project Wiki: https://wiki.opnfv.org/characterize_vswitch_performance_for_telco_nfv_use_cases
-* Project Repository: https://gerrit.opnfv.org/gerrit/#/q/vswitchperf
+* Project Repository: https://git.opnfv.org/vswitchperf
+* Project Artifacts: https://artifacts.opnfv.org/vswitchperf.html
* Continuous Integration https://build.opnfv.org/ci/view/vswitchperf/
.. toctree::
@@ -34,4 +35,3 @@ Platform and VNF level testing and validation.
Indices
=======
* :ref:`search`
-
diff --git a/docs/msc/factory_and_loader.msc b/docs/msc/factory_and_loader.msc
index a744607e..a744607e 100755..100644
--- a/docs/msc/factory_and_loader.msc
+++ b/docs/msc/factory_and_loader.msc
diff --git a/docs/msc/traffic_controller.msc b/docs/msc/traffic_controller.msc
index bd66cce1..bd66cce1 100755..100644
--- a/docs/msc/traffic_controller.msc
+++ b/docs/msc/traffic_controller.msc
diff --git a/docs/msc/vsperf.msc b/docs/msc/vsperf.msc
index aec53604..aec53604 100755..100644
--- a/docs/msc/vsperf.msc
+++ b/docs/msc/vsperf.msc
diff --git a/docs/requirements/ietf_draft/draft-ietf-bmwg-vswitch-opnfv-01.xml b/docs/requirements/ietf_draft/draft-ietf-bmwg-vswitch-opnfv-01.xml
index c8a3d99b..c8a3d99b 100755..100644
--- a/docs/requirements/ietf_draft/draft-ietf-bmwg-vswitch-opnfv-01.xml
+++ b/docs/requirements/ietf_draft/draft-ietf-bmwg-vswitch-opnfv-01.xml
diff --git a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-00.xml b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-00.xml
index b5f7f833..b5f7f833 100755..100644
--- a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-00.xml
+++ b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-00.xml
diff --git a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-01.xml b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-01.xml
index a9405a77..a9405a77 100755..100644
--- a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-01.xml
+++ b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-01.xml
diff --git a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-02.xml b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-02.xml
index 9157763e..9157763e 100755..100644
--- a/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-02.xml
+++ b/docs/requirements/ietf_draft/draft-vsperf-bmwg-vswitch-opnfv-02.xml
diff --git a/docs/requirements/vm2vm_alternative_benchmark.png b/docs/requirements/vm2vm_alternative_benchmark.png
index d21334ba..d21334ba 100755..100644
--- a/docs/requirements/vm2vm_alternative_benchmark.png
+++ b/docs/requirements/vm2vm_alternative_benchmark.png
Binary files differ
diff --git a/docs/requirements/vm2vm_benchmark.png b/docs/requirements/vm2vm_benchmark.png
index 3a85e51f..3a85e51f 100755..100644
--- a/docs/requirements/vm2vm_benchmark.png
+++ b/docs/requirements/vm2vm_benchmark.png
Binary files differ
diff --git a/docs/requirements/vm2vm_hypervisor_benchmark.png b/docs/requirements/vm2vm_hypervisor_benchmark.png
index b5b76e8a..b5b76e8a 100755..100644
--- a/docs/requirements/vm2vm_hypervisor_benchmark.png
+++ b/docs/requirements/vm2vm_hypervisor_benchmark.png
Binary files differ
diff --git a/docs/requirements/vm2vm_virtual_interface_benchmark.png b/docs/requirements/vm2vm_virtual_interface_benchmark.png
index 55294af6..55294af6 100755..100644
--- a/docs/requirements/vm2vm_virtual_interface_benchmark.png
+++ b/docs/requirements/vm2vm_virtual_interface_benchmark.png
Binary files differ
diff --git a/docs/userguide/integration.rst b/docs/userguide/integration.rst
index 60ed9245..60ed9245 100755..100644
--- a/docs/userguide/integration.rst
+++ b/docs/userguide/integration.rst
diff --git a/docs/userguide/testusage.rst b/docs/userguide/testusage.rst
index 721fd635..721fd635 100755..100644
--- a/docs/userguide/testusage.rst
+++ b/docs/userguide/testusage.rst
diff --git a/docs/userguide/yardstick.rst b/docs/userguide/yardstick.rst
index c906df8e..c906df8e 100755..100644
--- a/docs/userguide/yardstick.rst
+++ b/docs/userguide/yardstick.rst