diff options
author | Maryam Tahhan <maryam.tahhan@intel.com> | 2016-03-02 15:45:48 +0000 |
---|---|---|
committer | Maryam Tahhan <maryam.tahhan@intel.com> | 2016-03-03 14:02:14 +0000 |
commit | a8f7b9adcd4aea96fd44b201c483b7fab08ce658 (patch) | |
tree | 1d76e70575da46f4595537135ef2dcec169413f8 /docs | |
parent | 174015dfc37446ca710fe70df1398d63adb0a873 (diff) |
docs: update LTD.CPU.RFC2544.0PacketLoss
Rename and update LTD.CPU.RFC2544.0PacketLoss to
LTD.Stress.RFC2544.0PacketLoss and adding the memory
stressing app also.
JIRA: VSPERF-252
Change-Id: Ib79249f5cfeb304e03ce7f21b5c97a8030edade3
Signed-off-by: Maryam Tahhan <maryam.tahhan@intel.com>
Reviewed-by: Christian Trautman <ctrautma@redhat.com>
Diffstat (limited to 'docs')
-rw-r--r-- | docs/requirements/vswitchperf_ltd.rst | 16 |
1 files changed, 8 insertions, 8 deletions
diff --git a/docs/requirements/vswitchperf_ltd.rst b/docs/requirements/vswitchperf_ltd.rst index 19837f3f..e64de67d 100644 --- a/docs/requirements/vswitchperf_ltd.rst +++ b/docs/requirements/vswitchperf_ltd.rst @@ -2227,9 +2227,9 @@ should be required. It is expected that more will be added. .. 3.2.3.6.1 -Test ID: LTD.CPU.RFC2544.0PacketLoss +Test ID: LTD.Stress.RFC2544.0PacketLoss ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ - **Title**: RFC 2544 0% Loss Compute Test + **Title**: RFC 2544 0% Loss CPU OR Memory Stress Test **Prerequisite Test**: @@ -2238,12 +2238,12 @@ Test ID: LTD.CPU.RFC2544.0PacketLoss **Description**: The aim of this test is to understand the overall performance of the - system when a CPU intensive application is run on the same DUT as the - Virtual Switch. For each frame size, an + system when a CPU or Memory intensive application is run on the same DUT as + the Virtual Switch. For each frame size, an LTD.Throughput.RFC2544.PacketLossRatio (0% Packet Loss) test should be - performed. Throughout the entire test a CPU intensive application should - be run on all cores on the system not in use by the Virtual Switch. For - NUMA system only cores on the same NUMA node are loaded. + performed. Throughout the entire test a CPU or Memory intensive application + should be run on all cores on the system not in use by the Virtual Switch. + For NUMA system only cores on the same NUMA node are loaded. It is recommended that stress-ng be used for loading the non-Virtual Switch cores but any stress tool MAY be used. @@ -2254,7 +2254,7 @@ Test ID: LTD.CPU.RFC2544.0PacketLoss The following are the metrics collected for this test: - - CPU utilization of the cores running the Virtual Switch. + - Memory and CPU utilization of the cores running the Virtual Switch. - The number of identity of the cores allocated to the Virtual Switch. - The configuration of the stress tool (for example the command line parameters used to start it.) |