diff options
author | Sridhar K. N. Rao <sridhar.rao@spirent.com> | 2018-04-04 00:03:21 +0530 |
---|---|---|
committer | Martin Klozik <martinx.klozik@intel.com> | 2018-04-11 09:11:12 +0000 |
commit | a9b7e94f1338806cb2503e782b6d7dba76bd9b4b (patch) | |
tree | 96c88cecc7e29b5d93436e4e9f6e27546bd4a851 | |
parent | ce4773f7717a8a7029ea284aca6b8afa0e94f385 (diff) |
Doc: Documentation of Additional tools configuration.
This patch adds tools.rst under docs/testing/user/configguide.
tools.rst include documentation of installing and configuring
Collectors, Loadgens and LLC-Cache Management.
Changed Interested to Interesting and updated barometer info.
Change-Id: Id8de4d25619780636d242a04304696f4093b4c07
Signed-off-by: Sridhar K. N. Rao <sridhar.rao@spirent.com>
-rw-r--r-- | docs/testing/user/configguide/index.rst | 1 | ||||
-rw-r--r-- | docs/testing/user/configguide/tools.rst | 177 | ||||
-rw-r--r-- | docs/testing/user/userguide/testusage.rst | 6 |
3 files changed, 184 insertions, 0 deletions
diff --git a/docs/testing/user/configguide/index.rst b/docs/testing/user/configguide/index.rst index 83908a97..75a2082d 100644 --- a/docs/testing/user/configguide/index.rst +++ b/docs/testing/user/configguide/index.rst @@ -48,6 +48,7 @@ VSPERF Install and Configuration ./installation.rst ./upgrade.rst ./trafficgen.rst + ./tools.rst ================= VSPERF Test Guide diff --git a/docs/testing/user/configguide/tools.rst b/docs/testing/user/configguide/tools.rst new file mode 100644 index 00000000..907e86d2 --- /dev/null +++ b/docs/testing/user/configguide/tools.rst @@ -0,0 +1,177 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) OPNFV, Intel Corporation, Spirent, AT&T and others. + +.. _additional-tools-configuration: + +============================================= +'vsperf' Additional Tools Configuration Guide +============================================= + +Overview +-------- + +VSPERF supports the following categories additional tools: + + * `Infrastructure Metrics Collectors`_ + * `Load Generators`_ + * `L3 Cache Management`_ + +Under each category, there are one or more tools supported by VSPERF. +This guide provides the details of how to install (if required) +and configure the above mentioned tools. + +.. _`Infrastructure Metrics Collectors`: + +Infrastructure Metrics Collection +--------------------------------- + +VSPERF supports following two tools for collecting and reporting the metrics: + +* pidstat +* collectd + +*pidstat* is a command in linux systems, which is used for monitoring individual +tasks currently being managed by Linux kernel. In VSPERF this command is used to +monitor *ovs-vswitchd*, *ovsdb-server* and *kvm* processes. + +*collectd* is linux application that collects, stores and transfers various system +metrics. For every category of metrics, there is a separate plugin in collectd. For +example, CPU plugin and Interface plugin provides all the cpu metrics and interface +metrics, respectively. CPU metrics may include user-time, system-time, etc., whereas +interface metrics may include received-packets, dropped-packets, etc. + +Installation +^^^^^^^^^^^^ + +No installation is required for *pidstat*, whereas, collectd has to be installed +separately. For installation of collectd, we recommend to follow the process described +in *OPNFV-Barometer* project, which can be found here `Barometer-Euphrates <http://docs.opnfv.org/en/stable-euphrates/submodules/barometer/docs/release/userguide/feature.userguide.html#building-all-barometer-upstreamed-plugins-from-scratch>`_ or the most +recent release. + +VSPERF assumes that collectd is installed and configured to send metrics over localhost. +The metrics sent should be for the following categories: CPU, Processes, Interface, +OVS, DPDK, Intel-RDT. + +Configuration +^^^^^^^^^^^^^ + +The configuration file for the collectors can be found in **conf/05_collector.conf**. +*pidstat* specific configuration includes: + +* ``PIDSTAT_MONITOR`` - processes to be monitored by pidstat +* ``PIDSTAT_OPTIONS`` - options which will be passed to pidstat command +* ``PIDSTAT_SAMPLE_INTERVAL`` - sampling interval used by pidstat to collect statistics +* ``LOG_FILE_PIDSTAT`` - prefix of pidstat's log file + +The *collectd* configuration option includes: + +* ``COLLECTD_IP`` - IP address where collectd is running +* ``COLLECTD_PORT`` - Port number over which collectd is sending the metrics +* ``COLLECTD_SECURITY_LEVEL`` - Security level for receiving metrics +* ``COLLECTD_AUTH_FILE`` - Authentication file for receiving metrics +* ``LOG_FILE_COLLECTD`` - Prefix for collectd's log file. +* ``COLLECTD_CPU_KEYS`` - Interesting metrics from CPU +* ``COLLECTD_PROCESSES_KEYS`` - Interesting metrics from processes +* ``COLLECTD_INTERFACE_KEYS`` - Interesting metrics from interface +* ``COLLECTD_OVSSTAT_KEYS`` - Interesting metrics from OVS +* ``COLLECTD_DPDKSTAT_KEYS`` - Interesting metrics from DPDK. +* ``COLLECTD_INTELRDT_KEYS`` - Interesting metrics from Intel-RDT +* ``COLLECTD_INTERFACE_XKEYS`` - Metrics to exclude from Interface +* ``COLLECTD_INTELRDT_XKEYS`` - Metrics to exclude from Intel-RDT + + +.. _`Load Generators`: + + +Load Generation +--------------- + +In VSPERF, load generation refers to creating background cpu and memory loads to +study the impact of these loads on system under test. There are two options to +create loads in VSPERF. These options are used for different use-cases. The options are: + +* stress or stress-ng +* Stressor-VMs + +*stress and stress-ng* are linux tools to stress the system in various ways. +It can stress different subsystems such as CPU and memory. *stress-ng* is the +improvised version of *stress*. StressorVMs are custom build virtual-machines +for the noisy-neighbor use-cases. + +Installation +^^^^^^^^^^^^ + +stress and stress-ng can be installed through standard linux installation process. +Information about stress-ng, including the steps for installing can be found +here: `stress-ng <https://github.com/ColinIanKing/stress-ng>`_ + +There are two options for StressorVMs - one is VMs based on stress-ng and second +is VM based on Spirent's cloudstress. VMs based on stress-ng can be found in this +`link <https://github.com/opensource-tnbt/stressng-images>`_ . Spirent's cloudstress +based VM can be downloaded from this `site <https://github.com/spirent/cloudstress>`_ + +These stressorVMs are of OSV based VMs, which are very small in size. Download +these VMs and place it in appropriate location, and this location will used in +the configuration - as mentioned below. + +Configuration +^^^^^^^^^^^^^ + +The configuration file for loadgens can be found in **conf/07_loadgen.conf**. +There are no specific configurations for stress and stress-ng commands based +load-generation. However, for StressorVMs, following configurations apply: + +* ``NN_COUNT`` - Number of stressor VMs required. +* ``NN_MEMORY`` - Comma separated memory configuration for each VM +* ``NN_SMP`` - Comma separated configuration for each VM +* ``NN_IMAGE`` - Comma separated list of Paths for each VM image +* ``NN_SHARED_DRIVE_TYPE`` - Comma separated list of shaed drive type for each VM +* ``NN_BOOT_DRIVE_TYPE`` - Comma separated list of boot drive type for each VM +* ``NN_CORE_BINDING`` - Comma separated lists of list specifying the cores associated with each VM. +* ``NN_NICS_NR`` - Comma seprated list of number of NICS for each VM +* ``NN_BASE_VNC_PORT`` - Base VNC port Index. +* ``NN_LOG_FILE`` - Name of the log file + +.. _`L3 Cache Management`: + +Last Level Cache Management +--------------------------- + +VSPERF support last-level cache management using Intel's RDT tool(s) - the +relavant ones are `Intel CAT-CMT <https://github.com/intel/intel-cmt-cat>`_ and +`Intel RMD <https://github.com/intel/rmd>`_. RMD is a linux daemon that runs on +individual hosts, and provides a REST API for control/orchestration layer to +request LLC for the VMs/Containers/Applications. RDT receives resource policy +form orchestration layer - in this case, from VSPERF - and enforce it on the host. +It achieves this enforcement via kernel interfaces such as resctrlfs and libpqos. +The resource here refer to the last-level cache. User can configure policies to +define how much of cache a CPU can get. The policy configuration is described below. + +Installation +^^^^^^^^^^^^ + +For installation of RMD tool, please install CAT-CMT first and then install RMD. +The details of installation can be found here: `Intel CAT-CMT <https://github.com/intel/intel-cmt-cat>`_ +and `Intel RMD <https://github.com/intel/rmd>`_ + +Configuration +^^^^^^^^^^^^^ + +The configuration file for cache management can be found in **conf/08_llcmanagement.conf**. + +VSPERF provides following configuration options, for user to define and enforce policies via RMD. + +* ``LLC_ALLOCATION`` - Enable or Disable LLC management. +* ``RMD_PORT`` - RMD port (port number on which API server is listening) +* ``RMD_SERVER_IP`` - IP address where RMD is running. Currently only localhost. +* ``RMD_API_VERSION`` - RMD version. Currently it is 'v1' +* ``POLICY_TYPE`` - Specify how the policy is defined - either COS or CUSTOM +* ``VSWITCH_COS`` - Class of service (CoS for Vswitch. CoS can be gold, silver-bf or bronze-shared. +* ``VNF_COS`` - Class of service for VNF +* ``PMD_COS`` - Class of service for PMD +* ``NOISEVM_COS`` - Class of service of Noisy VM. +* ``VSWITCH_CA`` - [min-cache-value, maxi-cache-value] for vswitch +* ``VNF_CA`` - [min-cache-value, max-cache-value] for VNF +* ``PMD_CA`` - [min-cache-value, max-cache-value] for PMD +* ``NOISEVM_CA`` - [min-cache-value, max-cache-value] for Noisy VM diff --git a/docs/testing/user/userguide/testusage.rst b/docs/testing/user/userguide/testusage.rst index f679566e..9b331869 100644 --- a/docs/testing/user/userguide/testusage.rst +++ b/docs/testing/user/userguide/testusage.rst @@ -216,6 +216,12 @@ A Kernel Module that provides OSI Layer 2 Ipv4 termination or forwarding with support for Destination Network Address Translation (DNAT) for both the MAC and IP addresses. l2fwd can be found in <vswitchperf_dir>/src/l2fwd +Additional Tools Setup +^^^^^^^^^^^^^^^^^^^^^^ + +Follow the `Additional tools instructions <additional-tools-configuration>` to +install and configure additional tools such as collectors and loadgens. + Executing tests ^^^^^^^^^^^^^^^ |