Age | Commit message (Collapse) | Author | Files | Lines |
|
Heat caching somehow messes our tests so we disable it before the tests
start.
For instance, if we do:
1. create example-net with NET_ID1
2. create VNFD1 with example-net
3. delete VNFD1
4. delete NET_ID1
5. create example-net with NET_ID2
6. create VNFD2 with example-net
heat has NET_ID1 cached as the id of example-net and tries to use that
instead of NET_ID2 to create VNFD2. This off course leads to a crash
since NET_ID1 does not exist anymore.
In the future we should investigate further why heat cache does not play
well for us (probably bc of tacker).
Change-Id: Iac07d78641e2d1ff0c2d67e46752d551833f19fd
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
|
|
Sometimes test sfc_one is failing because the firewall is not started when
the test begins. Waiting some seconds after starting the process corrects the
problem
Change-Id: Iebef292fa66338c3e27a325333cc5f1993facac5
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
Added vnfd_delete in the cleanup library
Change-Id: Iaa3e9ecb33a15bf882585786271fef206a54ffa0
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
Change-Id: I3cbbcd17182bf6f1f6558cb199577d989ac62ae6
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
Change-Id: Ie7b2a63c301819a79768d1b286ee00693cd1129b
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
We want to double check if the CI is using the correct tacker plugin
version
Change-Id: Ib6082014988daee316553d980c5e7f88d316fe8c
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
Change-Id: I1facd54b11ef6a090e39dd5977eb5cf7183147af
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
ODL does not clean all resources properly after tacker deletions, so we
add this as a post processing step
Change-Id: Ic485ee32b195f72235922ebe613af6c010cb57db
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
After further investigation we found out that the classifier is deployed in all
computes. When deploying several tests, ODL starts to function very slowly and
sometimes the classifier takes a long time to be deployed in one compute. That
tricked us and made us think that it was not deployed everywhere
Change-Id: I474a05f77a6342be741d14ffbdb674ef7f970908
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
If the first testcase throws an exception, the rest were not being
executed
Change-Id: I5fdc521da840ffdbc7a0bde120d7bfe7907b881c
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
We have to make sure that we source the correct credentials in the CI
Change-Id: I4d988943588bbc99a3118cb89eabfea37c41daf6
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
We need to call delete.sh after each test is run. The script is
implemented as a python module and called inside run_tests.py
Change-Id: I23a794be522b4713a44cc1d56587e0aadc6f1210
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
JIRA: SFC-88
Not a blocking bug but when the classifier is implemented in several computes,
we loop all computes. By the time the second compute is inspected, more than
10 seconds passed and thus, the classification rules are already there.
first_RSP should not be evaluated and rsps must be restarted
Change-Id: I70858d6b423eebd8088a79aebebb4950f031878d
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
JIRA: SFC-87
Due to ODL bugs, some topologies do not work
Change-Id: Ia2fcfe5948c308ce2348b52c01aa3ce58ac318d6
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
|
|
We copied the create_secgroup_rule function from
functest.openstack_utils and removed the logger.exception("Security
group exists") line.
This is very ugly and we should investigate an upstream fix after D
release.
Change-Id: I1674a77ebc3b3e3132b2b9e1f16a84106b2350eb
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
If both SFs are in one host, the classification rules are not implemented
in all the hosts
Change-Id: Ifea131a86f49d33fdc6110a13d5fdc6c2796f7fa
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
In the test case with only one chain the wait_classification function was not
working
Change-Id: I4cff1e61130b6fc68d736108a0da048909dad750
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
Client and server were not being created based on the topology shuffler and
thus the topology was not followed
Change-Id: I1d7228d2d75e4ecf57ff8eb1c4226b963b2b9dd4
Signed-off-by: “Manuel Buil” <mbuil@suse.com>
|
|
The second test case can also benefit from installer adapters
Change-Id: Ie2ce8c9112582fa39428e5410f1c7ae6274161ea
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
symmetric test case doe snot work in multicompute env. We want to avoid that it
is executed in CI because it will always fail in the Danube release
Change-Id: I2a12d9aea31df37c689d96ae7eb323339b8ffb89
Signed-off-by: Manuel Buil <mbuil@suse.com>
|
|
Labels serve as anchors/ refs when referenced from other documents
This patch adds labels to docs/*/*/index.rst
Change-Id: I22964ee60952047ca20d8d4c54db790b9c01ee5a
Signed-off-by: ShubhamRathi <shubhamiiitbackup@gmail.com>
|
|
SFTP does not expand ~ to $HOME dir
Change-Id: I2d710c577986152a5cc703ca3668ae7b7767a07e
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
|
|
Due to JIRA SFC-86, this test is not working (althouth it will pass with a
topology where all the VMs are deployed in a single compute node).
Change-Id: I98231d22a0b340c305ba83ee78634c83fa4dc7e7
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
Using the new functions in functest to retrieve the nova ID for a VNF instance,
it is possible to use a generic solution at the problem of getting floating
ips deterministcally to the instances
Change-Id: Ie77820b0f466dcbf8ac771f12b5aee55ef74ead5
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
|
|
run_cmd does not have enough information to determine if something should
be logged with ERROR level. For example, you might want to repeat a command
until it succeeds, and you would expect it to fail the first times, so it
would not be an error in that context.
Let's keep the debug logging only, which should be informative for
troubleshooting.
Change-Id: I72bc40e58d19188b83ad289fe7fa2b4453d5ad56
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
Also, fix some wrong parameters, and add a script to delete
the artifacts created by the test case
Change-Id: I354007e75da62c706e79c793a9e6a422a6a50bf1
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
|
|
The topology for this test is fixed for the Danube release.
When it is stable for some time, we can try changing topologies.
Change-Id: I43f06ff973c74fbaea3aa9161f7a177b3ee94791
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
The function now uses return codes instead of parsing the output of
the command. Unused options have been removed as well.
Added a default retry_timeout for the command to avoid ping hangs.
Change-Id: I8c1f0f03d8b1e3092743c8745399a08fa7df8e40
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
|
|
Right now we check the classification rules only on the first compute
node. This leads to race conditions when running the testcases on
multiple computes (ie the test fails when a rule is installed in the
first compute but not the other[s])
Change-Id: I13cf26201aae185a0a5d1220b38e061d8bd3c766
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
Add a topology where everything (endpoints, vnfs) are booted on the same
host. This is useful, as we'll have the simplest possible topology to
compare against as a baseline
Change-Id: I6248fbca0687286da49f6332e01571937b501090
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
Change-Id: Ide425e860ad219ec24765905666994390858cfdb
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
Change-Id: Ic68256410b29cf3ba39a10a92d243979ea475220
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
JIRA: SFC-53
The goal is to verify that the traffic traverses the service chain, not only
in the uplink (client --> server) direction, but also in the downlink
(client <-- server) direction, which is the part that is not currently being
covered by other test cases.
Change-Id: I198a53e5afe3da1b397cee95627834856498b674
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
JIRA: SFC-63
The test will run in a number of configurations as described in SFC-63.
We expect to get decent coverage with these 5 topologies:
1. CLIENT_VNF_SAME_HOST
2. CLIENT_SERVER_SAME_HOST
3. SERVER_VNF_SAME_HOST
4. CLIENT_SERVER_SAME_HOST_SPLIT_VNF
5. CLIENT_SERVER_DIFFERENT_HOST_SPLIT_VNF
Change-Id: Iaca75bf180c33e3d22759e4da1ca4897072f68a6
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
- Fix getting the length of available topologies
- Format a correct vnf parameter file
Change-Id: I6c3534a67b44be6fcfb09d99856e5c27bcbd2ed1
Signed-off-by: George Paraskevopoulos <geopar@intracom-telecom.com>
|
|
Change-Id: Ida31e1e7f1b638f1ba5e851cbdfd0379c0f546d4
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
|
|
|
|
|
|
Change-Id: I3dedc06f0b288684a907df14874f277449c33146
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
Change-Id: I10b82e9a48363cbe10c62d4f4f7f9b22371b06e9
Signed-off-by: Juan Vidal <juan.vidal.allende@ericsson.com>
|
|
|
|
|
|
- After talking to Sofia Wallin, we agreed that this is a
better approach for the documentation.
Change-Id: Ie3edcb11e4d7823b0d3362395a15bf73aeaaaf4b
Signed-off-by: Brady Johnson <brady.allen.johnson@ericsson.com>
|