summaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
Diffstat (limited to 'docs')
-rw-r--r--docs/labs/images/orange_paris_pod1.jpgbin0 -> 353262 bytes
-rw-r--r--docs/labs/orange_paris_lab_description.rst73
-rw-r--r--docs/labs/orange_paris_pod1_description.rst127
3 files changed, 200 insertions, 0 deletions
diff --git a/docs/labs/images/orange_paris_pod1.jpg b/docs/labs/images/orange_paris_pod1.jpg
new file mode 100644
index 00000000..8e6427f5
--- /dev/null
+++ b/docs/labs/images/orange_paris_pod1.jpg
Binary files differ
diff --git a/docs/labs/orange_paris_lab_description.rst b/docs/labs/orange_paris_lab_description.rst
new file mode 100644
index 00000000..f22d90fb
--- /dev/null
+++ b/docs/labs/orange_paris_lab_description.rst
@@ -0,0 +1,73 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International License.
+.. http://creativecommons.org/licenses/by/4.0
+
+**************************
+Lab Specification Template
+**************************
+
+Introduction
+------------
+
+Orange is hosting an OPNFV test lab at Chatillon (near Paris) facility.
+The test lab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project.
+
+The Orange Paris lab consist of 1 POD
+ * POD for Fuel
+
+
+Lab Resources
+-------------
+
++----------------+----------------+----------------+----------------+----------------+----------------+----------------+
+| POD Name | Project(s) | Project Lead(s)| Email(s) | POD Role | Status | Notes |
++----------------+----------------+----------------+----------------+----------------+----------------+----------------+
+| opnfv-integ | | | | Dev/test | Active | |
++----------------+----------------+----------------+----------------+----------------+----------------+----------------+
+
+* **POD Name:** Use consistent naming / numbering to avoid confusion. Hyperlinked to POD description.
+* **POD Role:** CI stable, CI latest, Dev/test, Stand-alone, Virtual, ...
+* **Status:** Assigned, Configuring, Active, Troubleshooting, Available, ...
+
+
+Acceptable Usage Policy
+-----------------------
+
+Define lab user policies and expectations
+
+
+Remote Access Infrastructure
+----------------------------
+
+The Orange Paris OPNFV test lab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Orange Paris Testlab.
+
+To access the Testlab, please contact Auboin Cyril (cyril.auboin@orange.com) with the following details:
+ * Name
+ * Organization
+ * Purpose of using the labs
+ * Dates start / end
+
+Processing the request can take 3-4 business days.
+
+
+Remote Access Procedure
+-----------------------
+
+Define lab process for requesting access to the lab (e.g. VPN guide, how to modify BIOS settings, etc.)
+
+
+Lab Documentation
+-----------------
+
+List lab specific documents here
+
+
+Lab Topology
+------------
+
+Provide a diagram showing the network topology of lab including lights-out network. Any security sensitive details should
+not be exposed publically. The following diagram is an example only.
+
+.. image:: ./images/orange_paris_pod1.jpg
+ :alt: Lab diagram not found
diff --git a/docs/labs/orange_paris_pod1_description.rst b/docs/labs/orange_paris_pod1_description.rst
new file mode 100644
index 00000000..59dde96a
--- /dev/null
+++ b/docs/labs/orange_paris_pod1_description.rst
@@ -0,0 +1,127 @@
+.. This work is licensed under a Creative Commons Attribution 4.0 International License.
+.. http://creativecommons.org/licenses/by/4.0
+
+**************************
+POD Specification Template
+**************************
+
+Introduction
+------------
+
+Orange is hosting an OPNFV test lab at Chatillon (near Paris) facility.
+The test lab would host 4 (1 controller and 3 computes) baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project.
+
+Version: Brahmaputra
+Installer: Fuel (with Ceph)
+
+Additional Requirements
+-----------------------
+
+Server Specifications
+---------------------
+
+**Switch**
+
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number| CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1- | JUNIPER | EX-4550 | 750-045407 | | | | 172.31.2.254 | | | 32 ports |
+| switch | | | | | | | CC:E1:7F:86:38:80 | | | |
+| | | | | | | | | | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+
+**Jump Host**
+
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number| CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1- | DELL | Proliant | CZJ40901PV | Intel Xeon | 16 GB | 300GB SAS | | IF0: 172.31.13.5 | | |
+| jump-host | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | | | |
+| | | Gen8 | |2,5Ghz 24 core| | | | | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+
+**Firewall**
+
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number| CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1- | IBM | @Server | | Intel Xeon | 4 GB | 36GB SATA | | IF0: 161.105.211.2 | | |
+| firewall | | xSerie 336 | KKTVY4M | | | 36GB SATA | | | | |
+| | | | | | | | | | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+
+**Controller Node**
+
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number| CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1-ctrl1 | HP | Proliant | CZJ40901PT | Intel Xeon | 16GB | 300GB SAS | | IF0: 9C:B6:54:95:E4:74 | | |
+| | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | Admin | | |
+| | | Gen8 | | 2,5Ghz | | | | IF1: 9C:B6:54:95:E4:75 | | |
+| | | | | 24 core | | | | 18: Public | | |
+| | | | | | | | | 1500: Storage | | |
+| | | | | | | | | 17: Management | | |
+| | | | | | | | | 1502: Private | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+
+**Compute Nodes**
+
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| | | | | | | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | |
+| Hostname | Vendor | Model | Serial Number| CPUs | Memory | storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1-node1 | DELL | R730 | 8F3J642 | Intel Xeon | 128GB | 250GB SATA | | IF0: EC:F4:BB:CB:62:9C | | |
+| | | | | E5-2603 v3 | (8x16GB) | 480GB SSD | | Admin | | |
+| | | | | 1,6Ghz | 1600Mhz | 480GB SSD | | IF1: EC:F4:BB:CB:62:9A | | |
+| | | | | 12 core | | | | 18: Public | | |
+| | | | | | | | | 1500: Storage | | |
+| | | | | | | | | 17: Management | | |
+| | | | | | | | | 1502: Private | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1-node2 | HP | Proliant | CZJ40901PS | Intel Xeon | 16GB | 300GB SAS | | IF0: 9C:B6:54:95:D4:F0 | | |
+| | | DL 360e | | E5-2430 v2.2 | | 300GB SAS | | Admin | | |
+| | | Gen8 | | 2,5Ghz | | | | IF1: 9C:B6:54:95:D4:F1 | | |
+| | | | | 24 core | | | | 18: Public | | |
+| | | | | | | | | 1500: Storage | | |
+| | | | | | | | | 17: Management | | |
+| | | | | | | | | 1502: Private | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+| pod1-node3 | DELL | R730 | FG3J642 | Intel Xeon | 128GB | 256GB SATA | | IF0: EC:F4:BB:CB:62:E4 | | |
+| | | | | E5-2603 v3 | (8x16GB) | 480GB SSD | | Admin | | |
+| | | | | 1,6Ghz | 1600Mhz | 480GB SSD | | IF1: EC:F4:BB:CB:62:E2 | | |
+| | | | | 12 core | | | | 18: Public | | |
+| | | | | | | | | 1500: Storage | | |
+| | | | | | | | | 17: Management | | |
+| | | | | | | | | 1502: Private | | |
++--------------+--------------+--------------+--------------+--------------+--------------+--------------+------------------------+------------------------+------------------------+--------------+
+
+Users
+-----
+
++------------------+-----------------------------+--------------+--------------+--------------+
+| Name | Email | Company | Role | Notes |
++------------------+-----------------------------+--------------+--------------+--------------+
+| | | | | |
++------------------+-----------------------------+--------------+--------------+--------------+
+
+Firewall Rules
+--------------
+
++--------------+--------------+--------------+
+| Port(s) | Service | Note |
++--------------+--------------+--------------+
+| 22, 43, 80 | Jenkins CI | |
++--------------+--------------+--------------+
+
+POD Topology
+------------
+
+Provide a diagram showing the network topology of the POD. Any security sensitive details should
+not be exposed publically and can be stored in the secure Pharos repo. The following diagram is an example only.
+
+.. image:: ./images/orange_paris_pod1.jpg
+ :alt: POD diagram not found