diff options
Diffstat (limited to 'docs/labs')
-rw-r--r-- | docs/labs/Dell.rst | 356 | ||||
-rw-r--r-- | docs/labs/images/spirent_vptc-public-drawing.png | bin | 0 -> 80627 bytes | |||
-rw-r--r-- | docs/labs/spirent.rst | 41 | ||||
-rw-r--r-- | docs/labs/templates/lab_details_template.rst | 71 |
4 files changed, 468 insertions, 0 deletions
diff --git a/docs/labs/Dell.rst b/docs/labs/Dell.rst new file mode 100644 index 00000000..44d453a9 --- /dev/null +++ b/docs/labs/Dell.rst @@ -0,0 +1,356 @@ +Dell OPNFV Testlab +================================================== + +Overview +------------------ + +Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project. + +The Dell Testlab consists of 2 PODs + * POD1 for Fuel + * POD2 for Foreman + +.. image:: images/Dell_Overview.jpg + :alt: Dell OPNFV Testlab Overview + +Each of the 2 PODs consists of 6 servers that consist of + * 1 Jump Server + * 3 Servers for Control Nodes + * 2 Servers for Compute Nodes + + +Hardware details +----------------- + + +**POD1-Fuel** + +The specifications for the servers within POD1 can be found below: + ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +| Hostname | Model | Memory | Storage | Processor | Socket | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Fuel Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node2 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node3 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node4 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node5 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node6 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ + +The specifications for the Network Interfaces of servers within POD1 can be seen below: + ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +| Hostname | NIC Model | Ports| MAC | BW | Roles | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ +|Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public | +| | +------+-------------------+-------+----------------------------------+ +| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage | +| +----------------------------------------------+------+-------------------+-------+----------------------------------+ +| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused | +| | +------+-------------------+-------+----------------------------------+ +| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused | ++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ + + + +**POD2-Foreman** + +The specifications for the servers within POD2 can be found below: ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +| Hostname | Model | Memory | Storage | Processor | Socket | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Foreman Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node7 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node8 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node9 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node11 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ +|Node12 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | ++---------------------+---------------------+----------------+--------------+---------------------+------------+ + + +The specifications for the Network Interfaces of the servers within POD2 can be seen below: ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +| Hostname | NIC Model | Ports| MAC | BW | Roles | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:1D| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B5:20| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:21| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B5:23| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:CF| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B4:D2| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:D3| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B4:D5| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:D7| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B4:DA| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:DC| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B4:DF| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:E0| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B4:E2| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:E4| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B4:E7| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:E9| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B4:EC| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:ED| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B4:EF| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B4:F1| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B4:F3| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:03| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B5:06| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:07| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B5:09| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B5:0B| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B5:0D| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ +|Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:10| 10G | Foreman Admin | +| | +------+-----------------+-------+----------------------------------+ +| | | em2 |A4:1F:72:11:B5:13| 10G | Foreman Private/ Storage | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:14| 10G | Public | +| | +------+-----------------+-------+----------------------------------+ +| | | p3p2 |A4:1F:72:11:B5:16| 10G | Unused | +| +----------------------------------------------+------+-----------------+-------+----------------------------------+ +| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | +| | +------+-----------------+-------+----------------------------------+ +| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | ++---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ + + + + + + +Software +--------- + +The Jump servers in the Testlab are pre-provisioned with the following software: + + * Fuel-Jump Server: + 1. OS: Ubuntu 14.04 + 2. Preprovisoned softwares: KVM, VNC server + + + * Foreman-Jump Server: + 1. OS: Provisioned with CentOS7 + + + + + +Networks +---------- + + +**POD1-Foreman Diagram** + +.. image:: images/Dell_POD1.jpg + :alt: Dell POD1 Networking + + + + +**POD2-Foreman Diagram** + +.. image:: images/Dell_POD2.jpg + :alt: Dell POD2 Networking + + + + +**Subnet allocations** + ++-------------------+----------------+-------------------+---------------+----------+ +| Network name | Address | Mask | Gateway | VLAN id | ++-------------------+----------------+-------------------+---------------+----------+ +| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +| Public | 172.18.0.0 | 255.255.255.0 | 172.18.0.1 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Admin |10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Mangement |192.168.0.0 | 255.255.255.0 |192.168.0.1 | 101 | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Storage |192.168.1.0 | 255.255.255.0 |192.168.1.1 | 102 | ++-------------------+----------------+-------------------+---------------+----------+ + + +**Lights out Network** + +**POD1** + ++----------------+-------------------------------+------------------+---------------------+---------------------+ +| Hostname | Lights-out address | MAC |Username | Password | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Fuel-Jump | 172.18.1.101 |A4:1F:72:11:B4:80 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node2 | 172.18.1.102 |A4:1F:72:11:B4:8D | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node3 | 172.18.1.103 |A4:1F:72:11:B4:9A | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node4 | 172.18.1.104 |A4:1F:72:11:B4:A7 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node5 | 172.18.1.105 |A4:1F:72:11:B4:B4 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node6 | 172.18.1.106 |A4:1F:72:11:B4:C1 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ + +**POD2** + ++----------------+-------------------------------+------------------+---------------------+---------------------+ +| Hostname | Lights-out address | MAC |Username | Password | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Foreman-Jump | 172.18.1.113 |A4:1F:72:11:B5:1C | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node7 | 172.18.1.107 |A4:1F:72:11:B4:CE | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node8 | 172.18.1.108 |A4:1F:72:11:B4:DB | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node9 | 172.18.1.109 |A4:1F:72:11:B4:E8 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node11 | 172.18.1.111 |A4:1F:72:11:B5:02 | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ +|Node12 | 172.18.1.112 |A4:1F:72:11:B5:0F | root | calvin | ++----------------+-------------------------------+------------------+---------------------+---------------------+ + + + + + + + + + +Remote access infrastructure +----------------------------- + +The Dell OPNFV testlab is free to use for the OPNFV community. + +A VPN is used to provide access to the Dell Testlab. Details can be found in *Dell OPNFV-lab Access* document (Attach link) + +To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details: + * Name + * Organization + * Purpose of using the lab + + Processing the request can take 2-3 business days. + + **Accessing the Jump Server** + + The credentials for accessing the Jump servers are: + + *Fuel-Jump* + + User: opnfv + password: d3ll1234 + + *Foreman-Jump* + + User: root + password: d3ll1234 diff --git a/docs/labs/images/spirent_vptc-public-drawing.png b/docs/labs/images/spirent_vptc-public-drawing.png Binary files differnew file mode 100644 index 00000000..174ac454 --- /dev/null +++ b/docs/labs/images/spirent_vptc-public-drawing.png diff --git a/docs/labs/spirent.rst b/docs/labs/spirent.rst new file mode 100644 index 00000000..4ec987bd --- /dev/null +++ b/docs/labs/spirent.rst @@ -0,0 +1,41 @@ +Spirent Virtual Cloud Test Lab +=============================== + +A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight, OpenStack, OPNFV projects. + +**Spirent VCT Lab** is currently working on 3 different **OpenStack** environments each one of them deployed on different hardware configuration: + + * **OpenStack Juno - 2014.2.2 release** (CentOS 7, 20 Cores, 64 GB RAM, 1 TB SATA, 40 Gbps) + * **OpenStack Juno - 2014.2.2 release** (Ubuntu 14.04, 8 cores, 32 GB RAM, 500 GB SATA, 10 Gbps) + * **OpenStack Icehouse - 2014.1.3 release** + * **OpenStack Icehouse - 2014.1.3 release** + +---- + +There are a number of different networks referenced in the VPTC Design Blueprint. + + * Public Internet – 1 g + * Private Management – 1g + * Mission Clients – 10g + * Mission Servers – 10g + +These can be added or removed as specified by the test methodology. +There are 8 x 10 gige SFP+ ports available on a typical C100MP used for Avalanche Layer 4-7 testing. +The N4U offers 2 x 40 gige QSFP+ ports with the MX-2 Spirent Test Center Layer 2-3 testing. +There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10 gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports. +Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical traffic generators at the same time. Assuming a 10 to 1 oversubscription ratio we could handle 80 community users with the current environment. +For example: + + * An 80 Gbps test would need 4 port pairs of 10 gige each and require 8 mission networks. + * Multiple clients sharing common test hardware might have dedicated management networks for their DUTs yet communicate with the APIs and Management services via a shared DMZ network protected by a firewall. + * SSL and IPSec VPN will typically be leveraged to connect networks across the untrusted Internet or other third party networks. + * Stand-alone DUT servers using STCv and AVv traffic generators could easily scale to hundreds of servers as needed. + +.. image:: iamges/spirent_vptc-public-drawing.png + +**Documentation tracking** + +Revision: _sha1_ + +Build date: _date_ + diff --git a/docs/labs/templates/lab_details_template.rst b/docs/labs/templates/lab_details_template.rst new file mode 100644 index 00000000..bcc909ad --- /dev/null +++ b/docs/labs/templates/lab_details_template.rst @@ -0,0 +1,71 @@ +Pharos Lab Details Template +============================ + +Hardware details +----------------- + +**General details** + ++----------------+------------------+----------------------+-----------------------+------------------+-----------+-------------+----------------------------------------------+---------+ +| Hostname | Node type | HW model | Storage | CPU model | # Sockets | Memory [GB] | # NIC [MAC / IP / VLAN id] | BW | ++----------------+------------------+----------------------+-----------------------+------------------+-----------+-------------+----------------------------------------------+---------+ +| galileo | network | Dell R730 | 3 x 1TB (raid 5) | IntelE5-2690 v2 | 2 | 64 | 1 # 00:ae:ff:cc:dd:12 / 192.168.22.10 / 1003 | 10 Gbps | +| | | | | | | | 2 # 00:11:22:33:44:55 / 10.7.8.10 / 1 | 1 Gbps | ++----------------+------------------+----------------------+-----------------------+--------------+-----------+-------------+-------------------------------------------+------+---------+ + +**Lights-out** + ++----------------+-------------------------------+------------------+---------------------+ +| Hostname | Lights-out address | Username | Password | +-----------------+-------------------------------+------------------+---------------------+ +| | | | | ++----------------+-------------------------------+------------------+---------------------+ + + +Software +--------- + +**OS** + + +**Pre-provisioned software** + + +Network +-------- + +**Subnet allocations** + ++--------------+-------------------+-------------------+---------------+---------+ +| Net name | Address | Mask | Gateway | VLAN id | ++--------------+-------------------+-------------------+---------------+---------+ +| | | | | | ++--------------+-------------------+-------------------+---------------+---------+ + + +**Firewall rules** + + +**Diagrams** + +.. image:: images/<lab-name>_<diagram-name>.png|.jpg + :alt: Name of the diagram + +Remote access infrastructure +----------------------------- + +**Explanations** + +**Diagrams** + +.. image:: images/<lab-name>_<diagram-name>.png|.jpg + :alt: Name of the diagram + + +Documentation tracking +----------------------- + +Revision: _sha1_ + +Build date: _date_ + |