diff options
Diffstat (limited to 'docs/labs/zte-sh-lab/pod-2.rst')
-rw-r--r-- | docs/labs/zte-sh-lab/pod-2.rst | 162 |
1 files changed, 162 insertions, 0 deletions
diff --git a/docs/labs/zte-sh-lab/pod-2.rst b/docs/labs/zte-sh-lab/pod-2.rst new file mode 100644 index 00000000..961aa2a0 --- /dev/null +++ b/docs/labs/zte-sh-lab/pod-2.rst @@ -0,0 +1,162 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) 2016 OPNFV. + +.. _pharos_pod: + +********************** +ZTE POD2 Specification +********************** + + +Introduction +------------ + +POD2(means ZTE-POD2) uses Fuel as the installer and performs os-odl_l2-nofeature-ha CI latest +verification. Qtip daily CI task will be migrated from POD1 to POD2. Qtip is also working on +integration with Yardstick umbrella project. + + +Additional Requirements +----------------------- + + +Server Specifications +--------------------- + +**Jump Host** + +POD2 share the same **Jump Host** in the lab. + +**Deploy Server** + +POD2 share the same **Deploy Server** with POD1. + ++-----------+--------+-------+---------------+-----------+--------+-----------+--------------------+------------------+-------+ +| | | | | | Memory | Local | 1GbE: NIC#/IP | 10GbE: NIC#/IP | | +| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | MAC/VLAN/Network | MAC/VLAN/Network | Notes | ++-----------+--------+-------+---------------+-----------+--------+-----------+--------------------+------------------+-------+ +| Jellyfish | ZTE | R5300 | 277662500093 | E5-2620x2 | 128 | 600GB SAS | IF0: | | | +| | | | | | | 4 TB HDD | 74:4a:a4:00:91:b3/ | | | +| | | | | | | | 10.20.6.1/ | | | +| | | | | | | | native vlan/PXE | | | +| | | | | | | | IF1: | | | +| | | | | | | | 74:4a:a4:00:91:b4/ | | | +| | | | | | | | 10.20.7.1/ | | | +| | | | | | | | native vlan/PXE | | | ++-----------+--------+-------+---------------+-----------+--------+-----------+--------------------+------------------+-------+ + + +**Nodes/Servers** + ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| | | | | | Memory | Local | Lights-out network | 1GbE: NIC#/IP | 10GbE: NIC#/IP | | +| Hostname | Vendor | Model | Serial Number | CPUs | (GB) | Storage | (IPMI): IP/MAC, U/P | MAC/VLAN/Network | MAC/VLAN/Network | Notes | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| node1 | ZTE | E9000 | 701763100114 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.106 | ens4f0: | ens12f0: | | +| | | | | | | | 74:4a:a4:00:cd:6f | 74:4a:a4:00:cd:72 | 74:4a:a4:00:b0:e9 | | +| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | | +| | | | | | | | | | ens12f1: | | +| | | | | | | | | | 74:4a:a4:00:b0:ea | | +| | | | | | | | | | vlan 172/ storage | | +| | | | | | | | | | ens44f0: | | +| | | | | | | | | | 74:4a:a4:00:b0:eb | | +| | | | | | | | | | vlan 1130/ private | | +| | | | | | | | | | ens44f1: | | +| | | | | | | | | | 74:4a:a4:00:b0:ec | | +| | | | | | | | | | vlan 173/ public | | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| node2 | ZTE | E9000 | 701360500105 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.107 | ens4f0: | ens12f0: | | +| | | | | | | | 74:4a:a4:00:ca:c9 | 74:4a:a4:00:ca:cc | 74:4a:a4:00:d6:a3 | | +| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | | +| | | | | | | | | | ens12f1: | | +| | | | | | | | | | 74:4a:a4:00:d6:a4 | | +| | | | | | | | | | vlan 172/ storage | | +| | | | | | | | | | ens44f0: | | +| | | | | | | | | | 74:4a:a4:00:d6:99 | | +| | | | | | | | | | vlan 1130/ private | | +| | | | | | | | | | ens44f1: | | +| | | | | | | | | | 74:4a:a4:00:d6:9a | | +| | | | | | | | | | vlan 173/ public | | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| node3 | ZTE | E9000 | 701360500026 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.108 | ens4f0: | ens12f0: | | +| | | | | | | | 74:4a:a4:00:cd:0f | 74:4a:a4:00:cd:12 | 74:4a:a4:00:d6:9d | | +| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | | +| | | | | | | | | | ens12f1: | | +| | | | | | | | | | 74:4a:a4:00:d6:9e | | +| | | | | | | | | | vlan 172/ storage | | +| | | | | | | | | | ens44f0: | | +| | | | | | | | | | 74:4a:a4:00:d3:15 | | +| | | | | | | | | | vlan 1130/ private | | +| | | | | | | | | | ens44f1: | | +| | | | | | | | | | 74:4a:a4:00:d3:16 | | +| | | | | | | | | | vlan 173/ public | | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| node4 | ZTE | E9000 | 701763100099 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.109 | ens4f0: | ens12f0: | | +| | | | | | | | 74:4a:a4:00:cf:3d | 74:4a:a4:00:cf:40 | 74:4a:a4:00:d6:a5 | | +| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | | +| | | | | | | | | | ens12f1: | | +| | | | | | | | | | 74:4a:a4:00:d6:a6 | | +| | | | | | | | | | vlan 172/ storage | | +| | | | | | | | | | ens44f0: | | +| | | | | | | | | | 74:4a:a4:00:d6:a7 | | +| | | | | | | | | | vlan 1130/ private | | +| | | | | | | | | | ens44f1: | | +| | | | | | | | | | 74:4a:a4:00:d6:a8 | | +| | | | | | | | | | vlan 173/ public | | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ +| node5 | ZTE | E9000 | 701763100018 | E5-2650x2 | 128 | 600GB*2 HDD | 192.168.1.110 | ens4f0: | ens12f0: | | +| | | | | | | | 74:4a:a4:00:ce:d1 | 74:4a:a4:00:ce:d4 | 74:4a:a4:00:d2:c3 | | +| | | | | | | | zteroot/superuser | native vlan 170/PXE | vlan 171/ management | | +| | | | | | | | | | ens12f1: | | +| | | | | | | | | | 74:4a:a4:00:d2:c4 | | +| | | | | | | | | | vlan 172/ storage | | +| | | | | | | | | | ens44f0: | | +| | | | | | | | | | 74:4a:a4:00:d2:c1 | | +| | | | | | | | | | vlan 1130/ private | | +| | | | | | | | | | ens44f1: | | +| | | | | | | | | | 74:4a:a4:00:d2:c2 | | +| | | | | | | | | | vlan 173/ public | | ++----------+--------+-------+---------------+-----------+--------+-------------+---------------------+---------------------+----------------------+-------+ + + +**Subnet allocations** + ++----------------+--------------+----------------+------------+-----------------+ +| Network name | Address | Mask | Gateway | VLAN id | ++----------------+--------------+----------------+------------+-----------------+ +| Public | 172.70.0.0 | 255.255.255.0 | 172.70.0.1 | 173 | ++----------------+--------------+----------------+------------+-----------------+ +| Fuel Admin | 10.20.7.0 | 255.255.255.0 | 10.20.7.1 | native vlan 170 | ++----------------+--------------+----------------+------------+-----------------+ +| Fuel Mangement | 192.168.71.0 | 255.255.255.0 | | 171 | ++----------------+--------------+----------------+------------+-----------------+ +| Fuel Storage | 192.168.72.0 | 255.255.255.0 | | 172 | ++----------------+--------------+----------------+------------+-----------------+ + + +VPN Users +--------- + ++--------------+--------------+--------------+--------------+--------------+ +| Name | Email | Project | Role | Notes | ++--------------+--------------+--------------+--------------+--------------+ +| | | | | | ++--------------+--------------+--------------+--------------+--------------+ + + +Firewall Rules +-------------- + ++---------------+---------+------+ +| Port(s) | Service | Note | ++---------------+---------+------+ +| 1194(OpenVPN) | Jenkins | | ++---------------+---------+------+ + + +POD Topology +------------ + +.. image:: ./images/zte_sh_pod_topology.png + :alt: POD diagram not found |