diff options
-rw-r--r-- | docs/configguide/configguide.rst | 5 | ||||
-rw-r--r-- | docs/images/Dell_POD1.jpg | bin | 185357 -> 0 bytes | |||
-rw-r--r-- | docs/images/Dell_POD2.jpg | bin | 195042 -> 0 bytes | |||
-rw-r--r-- | docs/images/ZTE-POD.jpg | bin | 0 -> 369826 bytes | |||
-rw-r--r-- | docs/labs/Dell.rst | 734 | ||||
-rw-r--r-- | docs/labs/ZTE.rst | 241 | ||||
-rw-r--r-- | docs/labs/images/Dell_Overview.jpg (renamed from docs/images/Dell_Overview.jpg) | bin | 62317 -> 62317 bytes | |||
-rw-r--r-- | docs/labs/images/Dell_POD1.jpg | bin | 0 -> 189478 bytes | |||
-rw-r--r-- | docs/labs/images/Dell_POD2.jpg | bin | 0 -> 194546 bytes | |||
-rw-r--r-- | docs/labs/images/ZTE_Overview.jpg | bin | 0 -> 1800970 bytes | |||
-rw-r--r-- | docs/pharos-spec.rst | 1 | ||||
-rw-r--r-- | docs/pharos.rst | 7 | ||||
-rw-r--r-- | docs/specification/hardwarespec.rst | 44 | ||||
-rw-r--r-- | docs/specification/index.rst | 19 | ||||
-rw-r--r-- | docs/specification/jumpserverinstall.rst | 83 | ||||
-rw-r--r-- | docs/specification/networkconfig.rst | 74 | ||||
-rw-r--r-- | docs/specification/objectives.rst | 20 | ||||
-rw-r--r-- | docs/specification/remoteaccess.rst | 58 |
18 files changed, 928 insertions, 358 deletions
diff --git a/docs/configguide/configguide.rst b/docs/configguide/configguide.rst new file mode 100644 index 00000000..92d23b72 --- /dev/null +++ b/docs/configguide/configguide.rst @@ -0,0 +1,5 @@ +Pharos Lab Configuration requirements +===================================== + +Add an overview for the Pharos configuration guide here. This should be informative regarding the tasks +and expectations when configuring a lab to be pharos compliant and refer to the relevant pharos docs published from the project. diff --git a/docs/images/Dell_POD1.jpg b/docs/images/Dell_POD1.jpg Binary files differdeleted file mode 100644 index 42e4b49e..00000000 --- a/docs/images/Dell_POD1.jpg +++ /dev/null diff --git a/docs/images/Dell_POD2.jpg b/docs/images/Dell_POD2.jpg Binary files differdeleted file mode 100644 index 4d4b92cf..00000000 --- a/docs/images/Dell_POD2.jpg +++ /dev/null diff --git a/docs/images/ZTE-POD.jpg b/docs/images/ZTE-POD.jpg Binary files differnew file mode 100644 index 00000000..23907f9d --- /dev/null +++ b/docs/images/ZTE-POD.jpg diff --git a/docs/labs/Dell.rst b/docs/labs/Dell.rst index 44d453a9..c0c47506 100644 --- a/docs/labs/Dell.rst +++ b/docs/labs/Dell.rst @@ -1,356 +1,378 @@ -Dell OPNFV Testlab -================================================== - -Overview ------------------- - -Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project. - -The Dell Testlab consists of 2 PODs - * POD1 for Fuel - * POD2 for Foreman - -.. image:: images/Dell_Overview.jpg - :alt: Dell OPNFV Testlab Overview - -Each of the 2 PODs consists of 6 servers that consist of - * 1 Jump Server - * 3 Servers for Control Nodes - * 2 Servers for Compute Nodes - - -Hardware details ------------------ - - -**POD1-Fuel** - -The specifications for the servers within POD1 can be found below: - -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -| Hostname | Model | Memory | Storage | Processor | Socket | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Fuel Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node2 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node3 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node4 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node5 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node6 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ - -The specifications for the Network Interfaces of servers within POD1 can be seen below: - -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -| Hostname | NIC Model | Ports| MAC | BW | Roles | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ - - - -**POD2-Foreman** - -The specifications for the servers within POD2 can be found below: -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -| Hostname | Model | Memory | Storage | Processor | Socket | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Foreman Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node7 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node8 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node9 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node11 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node12 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ - - -The specifications for the Network Interfaces of the servers within POD2 can be seen below: -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -| Hostname | NIC Model | Ports| MAC | BW | Roles | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:1D| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:20| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:21| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:23| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:CF| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:D2| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:D3| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:D5| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:D7| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:DA| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:DC| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:DF| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:E0| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:E2| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:E4| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:E7| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:E9| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:EC| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:ED| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:EF| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B4:F1| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:F3| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:03| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:06| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:07| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:09| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B5:0B| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B5:0D| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:10| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:13| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:14| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:16| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ - - - - - - -Software ---------- - -The Jump servers in the Testlab are pre-provisioned with the following software: - - * Fuel-Jump Server: - 1. OS: Ubuntu 14.04 - 2. Preprovisoned softwares: KVM, VNC server - - - * Foreman-Jump Server: - 1. OS: Provisioned with CentOS7 - - - - - -Networks ----------- - - -**POD1-Foreman Diagram** - -.. image:: images/Dell_POD1.jpg - :alt: Dell POD1 Networking - - - - -**POD2-Foreman Diagram** - -.. image:: images/Dell_POD2.jpg - :alt: Dell POD2 Networking - - - - -**Subnet allocations** - -+-------------------+----------------+-------------------+---------------+----------+ -| Network name | Address | Mask | Gateway | VLAN id | -+-------------------+----------------+-------------------+---------------+----------+ -| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -| Public | 172.18.0.0 | 255.255.255.0 | 172.18.0.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Admin |10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Mangement |192.168.0.0 | 255.255.255.0 |192.168.0.1 | 101 | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Storage |192.168.1.0 | 255.255.255.0 |192.168.1.1 | 102 | -+-------------------+----------------+-------------------+---------------+----------+ - - -**Lights out Network** - -**POD1** - -+----------------+-------------------------------+------------------+---------------------+---------------------+ -| Hostname | Lights-out address | MAC |Username | Password | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Fuel-Jump | 172.18.1.101 |A4:1F:72:11:B4:80 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node2 | 172.18.1.102 |A4:1F:72:11:B4:8D | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node3 | 172.18.1.103 |A4:1F:72:11:B4:9A | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node4 | 172.18.1.104 |A4:1F:72:11:B4:A7 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node5 | 172.18.1.105 |A4:1F:72:11:B4:B4 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node6 | 172.18.1.106 |A4:1F:72:11:B4:C1 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ - -**POD2** - -+----------------+-------------------------------+------------------+---------------------+---------------------+ -| Hostname | Lights-out address | MAC |Username | Password | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Foreman-Jump | 172.18.1.113 |A4:1F:72:11:B5:1C | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node7 | 172.18.1.107 |A4:1F:72:11:B4:CE | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node8 | 172.18.1.108 |A4:1F:72:11:B4:DB | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node9 | 172.18.1.109 |A4:1F:72:11:B4:E8 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node11 | 172.18.1.111 |A4:1F:72:11:B5:02 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node12 | 172.18.1.112 |A4:1F:72:11:B5:0F | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ - - - - - - - - - -Remote access infrastructure ------------------------------ - -The Dell OPNFV testlab is free to use for the OPNFV community. - -A VPN is used to provide access to the Dell Testlab. Details can be found in *Dell OPNFV-lab Access* document (Attach link) - -To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details: - * Name - * Organization - * Purpose of using the lab - - Processing the request can take 2-3 business days. - - **Accessing the Jump Server** - - The credentials for accessing the Jump servers are: - - *Fuel-Jump* - - User: opnfv - password: d3ll1234 - - *Foreman-Jump* - - User: root - password: d3ll1234 +Dell OPNFV Testlab
+==================================================
+
+Overview
+------------------
+
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
+
+
+The Dell Testlab consists of 2 PODs
+ * POD1 for Fuel
+ * POD2 for Foreman
+
+.. image:: images/Dell_Overview.jpg
+ :height: 553
+ :width: 449
+ :alt: Dell Testlab Overiew
+ :align: left
+
+Each of the 2 PODs consists of 6 servers that consist of
+ * 1 Jump Server
+ * 3 Servers for Control Nodes
+ * 2 Servers for Compute Nodes
+
+
+
+Hardware details
+-----------------
+
+All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:
+
+
+
+**POD1-Fuel**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+**POD2-Foreman**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+
+Software
+---------
+
+The Jump servers in the Testlab are pre-provisioned with the following softwares:
+
+ * Fuel-Jump Server:
+
+ 1. OS: Ubuntu 14.04
+
+
+ * Foreman-Jump Server:
+
+ 1. OS: CentOS7
+
+
+
+
+
+Networks
+----------
+
+
+
+**POD1-Fuel**
+
+.. image:: images/Dell_POD1.jpg
+ :height: 647
+ :width: 821
+ :alt: POD1-Fuel Overview
+ :align: left
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+**POD2-Foreman**
+
+.. image:: images/Dell_POD2.jpg
+ :height: 721
+ :width: 785
+ :alt: POD2-Foreman Overview
+ :align: left
+
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+
+
+
+**Subnet allocations**
+
++-------------------+----------------+-------------------+---------------+----------+
+| Network name | Address | Mask | Gateway | VLAN id |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+
+
+**Lights out Network**
+
+**POD1**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+**POD2**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+
+
+
+
+
+Remote access infrastructure
+-----------------------------
+
+The Dell OPNFV testlab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Dell Testlab.
+
+To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
+ * Name
+ * Email
+ * Designation
+ * Organization
+ * Purpose of using the lab
+
+ Processing the request can take 2-3 business days.
+
+*Accessing the Teslab*
+-----------------------
+
+* POD1 JumpServer
+
+ IP: 172.18.0.67
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
+
+
+* POD2 JumpServer
+
+ IP: 172.18.0.11
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
diff --git a/docs/labs/ZTE.rst b/docs/labs/ZTE.rst new file mode 100644 index 00000000..809baf27 --- /dev/null +++ b/docs/labs/ZTE.rst @@ -0,0 +1,241 @@ +ZTE OPNFV Testlab +================================================== + +Overview +------------------ + +ZTE is hosting an OPNFV testlab at Nanjing facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project. + +The ZTE Testlab consists of 1 POD + * POD for Fuel + +.. image:: images/ZTE_Overview.jpg + :alt: ZTE OPNFV Testlab Overview + +The POD consists of 8 servers that consist of + * 3 Servers for Control Nodes + * 3 Servers for Compute Nodes + * 2 Servers for spare + + +Hardware details +----------------- + + +**POD-Fuel** + +The specifications for the servers within POD can be found below: + ++------------------+------------+-----------+-----------+---------------------+--------+ +| Hostname | Model | Memory | Storage | Processor | Socket | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Fuel Jump Server | ZTE R4300 | 32 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node4 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node5 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node6 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node10 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node11 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node12 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node13 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ +| Node14 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 | ++------------------+------------+-----------+-----------+---------------------+--------+ + +The specifications for the Network Interfaces of servers within POD can be seen below: + ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| Hostname | NIC Model | Ports | MAC | BW | Roles | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Fuel Jump | 1, RTL8111/8168/8411 | enp8s0 | 98:f5:37:e1:b4:1b | 10G | mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | enp9s0 | 98:f5:37:e1:b4:1c | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Inel 82599 | enp3s0f0 | 90:e2:ba:8b:08:64 | 10G | Unused | +| | +----------+-------------------+-------+----------------------------------+ +| | | enp3s0f1 | 90:e2:ba:8b:08:65 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node10 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:18 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:19 | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:1a | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:1b | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:d8 | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:d9 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node11 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:3c | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:3d | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:3e | 10G | Storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:3f | 10G | Storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:5a:d4 | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:5a:d5 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node12 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:08 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:09 | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:0a | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:0b | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:bd | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:be | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node4 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:1c | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:1d | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:1e | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:1f | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:a2 | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:a3 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node5 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:24 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:25 | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:26 | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:27 | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:ab | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:ac | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node6 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:40 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:41 | 10G | Public | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:42 | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:43 | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:fc | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:fd | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node13 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:38 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:39 | 10G | Unused | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:3a | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:3b | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:87 | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:88 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ +|Node14 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:48 | 10G | Public | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth1 | 4c:09:b4:b1:de:49 | 10G | Unused | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:4a | 10G | storage | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth3 | 4c:09:b4:b1:de:4b | 10G | storage | +| +----------------------------------------------+----------+-------------------+-------+----------------------------------+ +| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:75 | 10G | Admin/mgmt | +| | +----------+-------------------+-------+----------------------------------+ +| | | eth5 | 4c:09:b4:b2:59:76 | 10G | Unused | ++---------------------+----------------------------------------------+----------+-------------------+-------+----------------------------------+ + + +Software +--------- + +The Jump servers in the Testlab are pre-provisioned with the following software: + + * Fuel-Jump Server: + 1. OS: CentOS + 2. Preprovisoned softwares: KVM, VNC server + + + +Networks +---------- + +**POD-Fuel Diagram** + +.. image:: images/ZTE_POD.jpg + :alt: ZTE POD Networking + +**Subnet allocations** + ++-------------------+----------------+-------------------+---------------+----------+ +| Network name | Address | Mask | Gateway | VLAN id | ++-------------------+----------------+-------------------+---------------+----------+ +| Public |172.10.0.0 | 255.255.255.0 | 172.10.0.1 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Admin |192.168.0.0 | 255.255.255.0 | 192.168.0.1 | Untagged | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Mangement |192.168.11.0 | 255.255.255.0 | | 101 | ++-------------------+----------------+-------------------+---------------+----------+ +|Fuel Storage |192.168.12.0 | 255.255.255.0 | | 102 | ++-------------------+----------------+-------------------+---------------+----------+ + + +**Lights out Network** + +**POD** + +All nodes can log in by jumpserver. + ++-----------+-------------------------+-------------------+----------+----------+ +| Hostname | Lights-out address | MAC | Username | Password | ++-----------+-------------------------+-------------------+----------+----------+ +| Fuel-Jump | 58.213.14.182:5902(ssh) | 90:e2:ba:8b:08:65 | opnfv | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node4 | 192.168.0.7 | 06:9d:69:13:5f:45 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node5 | 192.168.0.8 | 32:9b:c4:da:10:4c | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node6 | 192.168.0.6 | 46:18:c4:74:cf:40 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node10 | 192.168.0.4 | be:d0:49:d4:06:42 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node11 | 192.168.0.3 | a2:d5:c1:bb:2b:49 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node12 | 192.168.0.2 | 62:08:00:cd:4c:43 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node13 | 192.168.0.9 | 4c:09:b4:b2:59:87 | | | ++-----------+-------------------------+-------------------+----------+----------+ +| Node14 | 192.168.0.10 | 9a:90:8a:db:e1:4c | | | ++-----------+-------------------------+-------------------+----------+----------+ + + +Remote access infrastructure +----------------------------- + +The ZTE OPNFV testlab is free to use for the OPNFV community. + +A VPN is used to provide access to the ZTE Testlab. Details can be found in *ZTE OPNFV-lab Access* document (Attach link) + +To access the Testlab, please contact Zhihui Wu(wu.zhihui1@zte.com.cn) with the following details: + * Name + * Organization + * Purpose of using the lab + + Processing the request can take 2-3 business days. + + **Accessing the Jump Server** + + The credentials for accessing the Jump Server, please contact Zhihui Wu(wu.zhihui1@zte.com.cn). diff --git a/docs/images/Dell_Overview.jpg b/docs/labs/images/Dell_Overview.jpg Binary files differindex 5a288a81..5a288a81 100644 --- a/docs/images/Dell_Overview.jpg +++ b/docs/labs/images/Dell_Overview.jpg diff --git a/docs/labs/images/Dell_POD1.jpg b/docs/labs/images/Dell_POD1.jpg Binary files differnew file mode 100644 index 00000000..d88549ba --- /dev/null +++ b/docs/labs/images/Dell_POD1.jpg diff --git a/docs/labs/images/Dell_POD2.jpg b/docs/labs/images/Dell_POD2.jpg Binary files differnew file mode 100644 index 00000000..9f1af3ce --- /dev/null +++ b/docs/labs/images/Dell_POD2.jpg diff --git a/docs/labs/images/ZTE_Overview.jpg b/docs/labs/images/ZTE_Overview.jpg Binary files differnew file mode 100644 index 00000000..26eee135 --- /dev/null +++ b/docs/labs/images/ZTE_Overview.jpg diff --git a/docs/pharos-spec.rst b/docs/pharos-spec.rst index 6aa6b20d..0ee06b51 100644 --- a/docs/pharos-spec.rst +++ b/docs/pharos-spec.rst @@ -140,6 +140,7 @@ Lights-out Management: - Intel lights-out ⇒ RMM http://www.intel.com/content/www/us/en/server-management/intel-remote-management-module.html - HP lights-out ⇒ ILO http://www8.hp.com/us/en/products/servers/ilo/index.html - CISCO lights-out ⇒ UCS https://developer.cisco.com/site/ucs-dev-center/index.gsp +- Dell lights-out ⇒ IDRAC http://en.community.dell.com/techcenter/systems-management/w/wiki/3204.dell-remote-access-controller-drac-idrac Linux Foundation - VPN service for accessing Lights-Out Management (LOM) infrastructure for the UCS-M hardware diff --git a/docs/pharos.rst b/docs/pharos.rst index 59bea397..dc0bcc6a 100644 --- a/docs/pharos.rst +++ b/docs/pharos.rst @@ -37,12 +37,15 @@ A summary of all Community Hosted OPNFV test labs (existing and planned) is also | 7 | Cable Labs | | | TBD | | | | | | | | | +-----------+---------------+------------------------------------------------------+---------------------------------------------+-------------------------------------+----------------------+ -| 8 | Dell | | Wenjing Chu | TBD | Santa Clara, CA | -| | | | Wenjing_Chu@DELL.com | | | +| 8 | Dell | https://wiki.opnfv.org/dell_hosting | Wenjing Chu | Operational with PODs based on Arno | Santa Clara, CA | +| | | | Wenjing_Chu@DELL.com | outputs | | +-----------+---------------+------------------------------------------------------+---------------------------------------------+-------------------------------------+----------------------+ | 9 | Huawei | | Sean Chen | TBD | Santa Clara, CA | | | | | | | | +-----------+---------------+------------------------------------------------------+---------------------------------------------+-------------------------------------+----------------------+ +| 10 | ZTE | | Zhihui Wu | BGS Parser Yardstick | Nanjing, China | +| | | | wu.zhihui1@zte.com.cn | | | ++-----------+---------------+------------------------------------------------------+---------------------------------------------+-------------------------------------+----------------------+ diff --git a/docs/specification/hardwarespec.rst b/docs/specification/hardwarespec.rst new file mode 100644 index 00000000..a861b7dd --- /dev/null +++ b/docs/specification/hardwarespec.rst @@ -0,0 +1,44 @@ +Pharos compliant environment +---------------------------- + +A pharos compliant OPNFV test-bed provides: + +- One CentOS 7 jump server on which the virtualized Openstack/OPNFV installer runs +- In the Brahmaputra release you may select a variety of deployment toolchains to deploy from the jump server. +- 5 compute / controller nodes (`BGS <https://wiki.opnfv.org/get_started/get_started_work_environment>`_ requires 5 nodes) +- A configured network topology allowing for LOM, Admin, Public, Private, and Storage Networks +- Remote access as defined by the Jenkins slave configuration guide +http://artifacts.opnfv.org/arno.2015.1.0/docs/opnfv-jenkins-slave-connection.arno.2015.1.0.pdf + +Hardware requirements +--------------------- + +**Servers** + +CPU: + +* Intel Xeon E5-2600v2 Series +(Ivy Bridge and newer, or similar) + +Local Storage Configuration: + +Below describes the minimum for the Pharos spec, +which is designed to provide enough capacity for +a reasonably functional environment. Additional +and/or faster disks are nice to have and may +produce a better result. + +* Disks: 2 x 1TB + 1 x 100GB SSD +* The first 1TB HDD should be used for OS & additional software/tool installation +* The second 1TB HDD configured for CEPH object storage +* Finally, the 100GB SSD should be used as the CEPH journal +* Performance testing requires a mix of compute nodes that have CEPH(swift+Cinder) and without CEPH storage +* Virtual ISO boot capabilities or a separate PXE boot server (DHCP/tftp or Cobbler) + +Memory: + +* 32G RAM Minimum + +Power Supply Single + +* Single power supply acceptable (redundant power not required/nice to have) diff --git a/docs/specification/index.rst b/docs/specification/index.rst new file mode 100644 index 00000000..39764efe --- /dev/null +++ b/docs/specification/index.rst @@ -0,0 +1,19 @@ +Pharos Specification +==================== + +.. toctree:: + :maxdepth: 2 + + ./objectives.rst + ./hardwarespec.rst + ./networkconfig.rst + ./jumpserverinstall.rst + ./remoteaccess.rst + +:Authors: Trevor Cooper (Intel) +:Version: 1.0 + +Indices and tables +================== + +* :ref:`search` diff --git a/docs/specification/jumpserverinstall.rst b/docs/specification/jumpserverinstall.rst new file mode 100644 index 00000000..a82c3352 --- /dev/null +++ b/docs/specification/jumpserverinstall.rst @@ -0,0 +1,83 @@ +**Jump Server Configuration:** + +(Rough Placeholder, edit me) + +**Fuel** + +1. Obtain CentOS 7 Minimal ISO and install + + ``wget http://mirrors.kernel.org/centos/7/isos/x86_64/CentOS-7-x86_64-Minimal-1503-01.iso`` + +2. Set parameters appropriate for your environment during installation + +3. Disable NetworkManager + + ``systemctl disable NetworkManager`` + +4. Configure your /etc/sysconfig/network-scripts/ifcfg-* files for your network + +5. Restart networking + + ``service network restart`` + +6. Edit /etc/resolv.conf and add a nameserver + + ``vi /etc/resolv.conf`` + +7. Install libvirt & kvm + + ``yum -y update`` + ``yum -y install kvm qemu-kvm libvirt`` + ``systemctl enable libvirtd`` + +8. Reboot: + + ``shutdown -r now`` + +9. If you wish to avoid annoying delay when use ssh to log in, disable DNS lookups: + + ``vi /etc/ssh/sshd_config`` + + Uncomment "UseDNS yes", change 'yes' to 'no'. + + Save + +10. Restart sshd + + ``systemctl restart sshd`` + +11. Install virt-install + + ``yum -y install virt-install`` + +12. Visit artifacts.opnfv.org and D/L the OPNFV Fuel ISO + +13. Create a bridge using the interface on the PXE network, for example: br0 + +14. Make a directory owned by qemu: + + ``mkdir /home/qemu; mkdir -p /home/qemu/VMs/fuel-6.0/disk`` + + ``chown -R qemu:qemu /home/qemu`` + +15. Copy the ISO to /home/qemu + + ``cd /home/qemu`` + + ``virt-install -n opnfv-2015-05-22_18-34-07-fuel -r 4096 --vcpus=4 + --cpuset=0-3 -c opnfv-2015-05-22_18-34-07.iso --os-type=linux + --os-variant=rhel6 --boot hd,cdrom --disk + path=/home/qemu/VMs/mirantis-fuel-6.0/disk/fuel-vhd0.qcow2,bus=virtio,size=50,format=qcow2 + -w bridge=br0,model=virtio --graphics vnc,listen=0.0.0.0`` + +16. Temporarily flush the firewall rules to make things easier: + + ``iptables -F`` + +17. Connect to the console of the installing VM with your favorite VNC client. + +18. Change the IP settings to match the pod, use an IP in the PXE/Admin network for the Fuel Master + +**Foreman** + +TBA diff --git a/docs/specification/networkconfig.rst b/docs/specification/networkconfig.rst new file mode 100644 index 00000000..510ea802 --- /dev/null +++ b/docs/specification/networkconfig.rst @@ -0,0 +1,74 @@ +Networking +---------- + +Test-bed network + +* 24 or 48 Port TOR Switch +* NICS - 1GE, 10GE - per server can be on-board or PCI-e +* Connectivity for each data/control network is through a separate NIC. + *This simplifies Switch Management howeverrequires more NICs on the server and also more switch ports +* Lights-out network can share with Admin/Management + +Network Interfaces + +* Option I: 4x1G Control, 2x40G Data, 48 Port Switch + + * 1 x 1G for ILMI (Lights out Management ) + * 1 x 1G for Admin/PXE boot + * 1 x 1G for control Plane connectivity + * 1 x 1G for storage + * 2 x 40G (or 10G) for data network (redundancy, NIC bonding, High bandwidth testing) + +* Option II: 1x1G Control, 2x 40G (or 10G) Data, 24 Port Switch + + * Connectivity to networks is through VLANs on the Control NIC. + * Data NIC used for VNF traffic and storage traffic segmented through VLANs + +* Option III: 2x1G Control, 2x10G Data, 2x40G Storage, 24 Port Switch + + * Data NIC used for VNF traffic + * Storage NIC used for control plane and Storage segmented through VLANs (separate host traffic from VNF) + * 1 x 1G for IPMI + * 1 x 1G for Admin/PXE boot + * 2 x 10G for control plane connectivity/Storage + * 2 x 40G (or 10G) for data network + +Documented configuration to include: +- Subnet, VLANs (may be constrained by existing lab setups or rules) +- IPs +- Types of NW - lights-out, public, private, admin, storage +- May be special NW requirements for performance related projects +- Default gateways + +ontroller node bridge topology overview + +.. image:: ../images/bridge1.png + +compute node bridge topology overview + +.. image:: ../images/bridge2.png + +Architecture +------------- + +** Network Diagram ** + +The Pharos architecture may be described as follow: +Figure 1: Standard Deployment Environment + +.. image:: ../images/opnfv-pharos-diagram-v01.jpg + +Figure 1: Standard Deployment Environment + +Sample Network Drawings +----------------------- + +Files for documenting lab network layout. +These were contributed as Visio VSDX format compressed as a ZIP +file. Here is a sample of what the visio looks like. + +Download the visio zip file here: +`opnfv-example-lab-diagram.vsdx.zip +<https://wiki.opnfv.org/_media/opnfv-example-lab-diagram.vsdx.zip>`_ + +.. image:: ../images/opnfv-example-lab-diagram.png diff --git a/docs/specification/objectives.rst b/docs/specification/objectives.rst new file mode 100644 index 00000000..53423882 --- /dev/null +++ b/docs/specification/objectives.rst @@ -0,0 +1,20 @@ +Objectives / Scope +------------------- + +The Pharos specification defines the OPNFV hardware environment +upon which the OPNFV Brahmaputra platform release can be deployed +on and tested. This specification defines: + +- A secure, scalable, standard and HA environment +- Supports the full Brahmaputra deployment lifecycle (this requires a bare metal environment) +- Supports functional and performance testing of the Brahmaputra release +- Provides mechanisms and procedures for secure remote access to the test environment + +Deploying Brahmaputra in a Virtualized environment is possible +and will be useful, however it does not provide a fully +featured deployment and test environment for the Brahmaputra +release of OPNFV. + +The high level architecture is outlined in the following diagram: + +.. image:: ../images/pharos-archi1.jpg diff --git a/docs/specification/remoteaccess.rst b/docs/specification/remoteaccess.rst new file mode 100644 index 00000000..e91d55e1 --- /dev/null +++ b/docs/specification/remoteaccess.rst @@ -0,0 +1,58 @@ +Remote management +------------------ + +**Remote access** + +- Remote access is required for … + + 1. Developers to access deploy/test environments (credentials to be issued per POD / user) + 2. Connection of each environment to Jenkins master hosted by Linux Foundation for automated deployment and test + +- OpenVPN is generally used for remote however community hosted labs may vary due to company security rules +- POD access rules / restrictions … + + - Refer to individual test-bed as each company may have different access rules and acceptable usage policies + +- Basic requirement is for SSH sessions to be established (initially on jump server) +- Majority of packages installed on a system (tools or applications) will be pulled from an external repo. + +Firewall rules should include + +- SSH sessions +- Jenkins sessions + +Lights-out Management: + +- Out-of-band management for power on/off/reset and bare-metal provisioning +- Access to server is through lights-out-management tool and/or a serial console +- Intel lights-out ⇒ RMM http://www.intel.com/content/www/us/en/server-management/intel-remote-management-module.html +- HP lights-out ⇒ ILO http://www8.hp.com/us/en/products/servers/ilo/index.html +- CISCO lights-out ⇒ UCS https://developer.cisco.com/site/ucs-dev-center/index.gsp + +Linux Foundation - VPN service for accessing Lights-Out +Management (LOM) infrastructure for the UCS-M hardware + +- People with admin access to LF infrastructure: + +1. amaged@cisco.com +2. cogibbs@cisco.com +3. daniel.smith@ericsson.com +4. dradez@redhat.com +5. fatih.degirmenci@ericsson.com +6. fbrockne@cisco.com +7. jonas.bjurel@ericsson.com +8. jose.lausuch@ericsson.com +9. joseph.gasparakis@intel.com +10. morgan.richomme@orange.com +11. pbandzi@cisco.com +12. phladky@cisco.com +13. stefan.k.berg@ericsson.com +14. szilard.cserey@ericsson.com +15. trozet@redhat.com + +- The people who require VPN access must have a valid +PGP key bearing a valid signature from one of these +three people. When issuing OpenVPN credentials, LF +will be sending TLS certificates and 2-factor +authentication tokens, encrypted to each recipient's PGP key. + |