diff options
author | Trevor Cooper <trevor.cooper@intel.com> | 2016-01-15 20:54:43 +0000 |
---|---|---|
committer | Gerrit Code Review <gerrit@172.30.200.206> | 2016-01-15 20:54:43 +0000 |
commit | e6a7d12173d9304ec81584b224ccc2ae5dc51985 (patch) | |
tree | 82e3f858600ad879cda080b7b1914d714131fd7f /docs | |
parent | 2f8e06b062f14c60e184f71c31b2739ccf83140e (diff) | |
parent | e078f4e147ac02a867259b854007c605266fe629 (diff) |
Merge "Updated Dell OPNFV Testlab doc"
Diffstat (limited to 'docs')
-rw-r--r-- | docs/images/Dell_POD1.jpg | bin | 185357 -> 0 bytes | |||
-rw-r--r-- | docs/images/Dell_POD2.jpg | bin | 195042 -> 0 bytes | |||
-rw-r--r-- | docs/labs/Dell.rst | 734 | ||||
-rw-r--r-- | docs/labs/images/Dell_Overview.jpg (renamed from docs/images/Dell_Overview.jpg) | bin | 62317 -> 62317 bytes | |||
-rw-r--r-- | docs/labs/images/Dell_POD1.jpg | bin | 0 -> 189478 bytes | |||
-rw-r--r-- | docs/labs/images/Dell_POD2.jpg | bin | 0 -> 194546 bytes |
6 files changed, 378 insertions, 356 deletions
diff --git a/docs/images/Dell_POD1.jpg b/docs/images/Dell_POD1.jpg Binary files differdeleted file mode 100644 index 42e4b49e..00000000 --- a/docs/images/Dell_POD1.jpg +++ /dev/null diff --git a/docs/images/Dell_POD2.jpg b/docs/images/Dell_POD2.jpg Binary files differdeleted file mode 100644 index 4d4b92cf..00000000 --- a/docs/images/Dell_POD2.jpg +++ /dev/null diff --git a/docs/labs/Dell.rst b/docs/labs/Dell.rst index 44d453a9..c0c47506 100644 --- a/docs/labs/Dell.rst +++ b/docs/labs/Dell.rst @@ -1,356 +1,378 @@ -Dell OPNFV Testlab -================================================== - -Overview ------------------- - -Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project. - -The Dell Testlab consists of 2 PODs - * POD1 for Fuel - * POD2 for Foreman - -.. image:: images/Dell_Overview.jpg - :alt: Dell OPNFV Testlab Overview - -Each of the 2 PODs consists of 6 servers that consist of - * 1 Jump Server - * 3 Servers for Control Nodes - * 2 Servers for Compute Nodes - - -Hardware details ------------------ - - -**POD1-Fuel** - -The specifications for the servers within POD1 can be found below: - -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -| Hostname | Model | Memory | Storage | Processor | Socket | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Fuel Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node2 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node3 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node4 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node5 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node6 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ - -The specifications for the Network Interfaces of servers within POD1 can be seen below: - -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -| Hostname | NIC Model | Ports| MAC | BW | Roles | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ -|Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public | -| | +------+-------------------+-------+----------------------------------+ -| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage | -| +----------------------------------------------+------+-------------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused | -| | +------+-------------------+-------+----------------------------------+ -| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused | -+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+ - - - -**POD2-Foreman** - -The specifications for the servers within POD2 can be found below: -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -| Hostname | Model | Memory | Storage | Processor | Socket | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Foreman Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node7 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node8 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node9 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node11 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ -|Node12 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 | -+---------------------+---------------------+----------------+--------------+---------------------+------------+ - - -The specifications for the Network Interfaces of the servers within POD2 can be seen below: -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -| Hostname | NIC Model | Ports| MAC | BW | Roles | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:1D| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:20| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:21| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:23| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:CF| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:D2| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:D3| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:D5| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:D7| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:DA| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:DC| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:DF| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:E0| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:E2| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:E4| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:E7| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:E9| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B4:EC| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:ED| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B4:EF| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B4:F1| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:F3| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:03| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:06| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:07| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:09| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B5:0B| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B5:0D| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ -|Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:10| 10G | Foreman Admin | -| | +------+-----------------+-------+----------------------------------+ -| | | em2 |A4:1F:72:11:B5:13| 10G | Foreman Private/ Storage | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:14| 10G | Public | -| | +------+-----------------+-------+----------------------------------+ -| | | p3p2 |A4:1F:72:11:B5:16| 10G | Unused | -| +----------------------------------------------+------+-----------------+-------+----------------------------------+ -| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused | -| | +------+-----------------+-------+----------------------------------+ -| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused | -+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+ - - - - - - -Software ---------- - -The Jump servers in the Testlab are pre-provisioned with the following software: - - * Fuel-Jump Server: - 1. OS: Ubuntu 14.04 - 2. Preprovisoned softwares: KVM, VNC server - - - * Foreman-Jump Server: - 1. OS: Provisioned with CentOS7 - - - - - -Networks ----------- - - -**POD1-Foreman Diagram** - -.. image:: images/Dell_POD1.jpg - :alt: Dell POD1 Networking - - - - -**POD2-Foreman Diagram** - -.. image:: images/Dell_POD2.jpg - :alt: Dell POD2 Networking - - - - -**Subnet allocations** - -+-------------------+----------------+-------------------+---------------+----------+ -| Network name | Address | Mask | Gateway | VLAN id | -+-------------------+----------------+-------------------+---------------+----------+ -| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -| Public | 172.18.0.0 | 255.255.255.0 | 172.18.0.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Admin |10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Mangement |192.168.0.0 | 255.255.255.0 |192.168.0.1 | 101 | -+-------------------+----------------+-------------------+---------------+----------+ -|Fuel Storage |192.168.1.0 | 255.255.255.0 |192.168.1.1 | 102 | -+-------------------+----------------+-------------------+---------------+----------+ - - -**Lights out Network** - -**POD1** - -+----------------+-------------------------------+------------------+---------------------+---------------------+ -| Hostname | Lights-out address | MAC |Username | Password | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Fuel-Jump | 172.18.1.101 |A4:1F:72:11:B4:80 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node2 | 172.18.1.102 |A4:1F:72:11:B4:8D | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node3 | 172.18.1.103 |A4:1F:72:11:B4:9A | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node4 | 172.18.1.104 |A4:1F:72:11:B4:A7 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node5 | 172.18.1.105 |A4:1F:72:11:B4:B4 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node6 | 172.18.1.106 |A4:1F:72:11:B4:C1 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ - -**POD2** - -+----------------+-------------------------------+------------------+---------------------+---------------------+ -| Hostname | Lights-out address | MAC |Username | Password | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Foreman-Jump | 172.18.1.113 |A4:1F:72:11:B5:1C | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node7 | 172.18.1.107 |A4:1F:72:11:B4:CE | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node8 | 172.18.1.108 |A4:1F:72:11:B4:DB | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node9 | 172.18.1.109 |A4:1F:72:11:B4:E8 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node11 | 172.18.1.111 |A4:1F:72:11:B5:02 | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ -|Node12 | 172.18.1.112 |A4:1F:72:11:B5:0F | root | calvin | -+----------------+-------------------------------+------------------+---------------------+---------------------+ - - - - - - - - - -Remote access infrastructure ------------------------------ - -The Dell OPNFV testlab is free to use for the OPNFV community. - -A VPN is used to provide access to the Dell Testlab. Details can be found in *Dell OPNFV-lab Access* document (Attach link) - -To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details: - * Name - * Organization - * Purpose of using the lab - - Processing the request can take 2-3 business days. - - **Accessing the Jump Server** - - The credentials for accessing the Jump servers are: - - *Fuel-Jump* - - User: opnfv - password: d3ll1234 - - *Foreman-Jump* - - User: root - password: d3ll1234 +Dell OPNFV Testlab
+==================================================
+
+Overview
+------------------
+
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
+
+
+The Dell Testlab consists of 2 PODs
+ * POD1 for Fuel
+ * POD2 for Foreman
+
+.. image:: images/Dell_Overview.jpg
+ :height: 553
+ :width: 449
+ :alt: Dell Testlab Overiew
+ :align: left
+
+Each of the 2 PODs consists of 6 servers that consist of
+ * 1 Jump Server
+ * 3 Servers for Control Nodes
+ * 2 Servers for Compute Nodes
+
+
+
+Hardware details
+-----------------
+
+All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:
+
+
+
+**POD1-Fuel**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+**POD2-Foreman**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+
+Software
+---------
+
+The Jump servers in the Testlab are pre-provisioned with the following softwares:
+
+ * Fuel-Jump Server:
+
+ 1. OS: Ubuntu 14.04
+
+
+ * Foreman-Jump Server:
+
+ 1. OS: CentOS7
+
+
+
+
+
+Networks
+----------
+
+
+
+**POD1-Fuel**
+
+.. image:: images/Dell_POD1.jpg
+ :height: 647
+ :width: 821
+ :alt: POD1-Fuel Overview
+ :align: left
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+**POD2-Foreman**
+
+.. image:: images/Dell_POD2.jpg
+ :height: 721
+ :width: 785
+ :alt: POD2-Foreman Overview
+ :align: left
+
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+
+
+
+**Subnet allocations**
+
++-------------------+----------------+-------------------+---------------+----------+
+| Network name | Address | Mask | Gateway | VLAN id |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+
+
+**Lights out Network**
+
+**POD1**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+**POD2**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+
+
+
+
+
+Remote access infrastructure
+-----------------------------
+
+The Dell OPNFV testlab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Dell Testlab.
+
+To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
+ * Name
+ * Email
+ * Designation
+ * Organization
+ * Purpose of using the lab
+
+ Processing the request can take 2-3 business days.
+
+*Accessing the Teslab*
+-----------------------
+
+* POD1 JumpServer
+
+ IP: 172.18.0.67
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
+
+
+* POD2 JumpServer
+
+ IP: 172.18.0.11
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
diff --git a/docs/images/Dell_Overview.jpg b/docs/labs/images/Dell_Overview.jpg Binary files differindex 5a288a81..5a288a81 100644 --- a/docs/images/Dell_Overview.jpg +++ b/docs/labs/images/Dell_Overview.jpg diff --git a/docs/labs/images/Dell_POD1.jpg b/docs/labs/images/Dell_POD1.jpg Binary files differnew file mode 100644 index 00000000..d88549ba --- /dev/null +++ b/docs/labs/images/Dell_POD1.jpg diff --git a/docs/labs/images/Dell_POD2.jpg b/docs/labs/images/Dell_POD2.jpg Binary files differnew file mode 100644 index 00000000..9f1af3ce --- /dev/null +++ b/docs/labs/images/Dell_POD2.jpg |