diff options
author | louie.long <longyu805@163.com> | 2018-01-18 11:46:21 +0800 |
---|---|---|
committer | Alexandru Avadanii <Alexandru.Avadanii@enea.com> | 2018-01-22 15:56:28 +0000 |
commit | b40fd8dbab5a9b349140b2400fda59653103e36e (patch) | |
tree | 39f0ae3dfb31c0a529b96bef4a67ab9a1b01879d | |
parent | 70fe6ed0f6ecadc54ac1d17f194178a07e911348 (diff) |
update BII pod1 PDF for Euphrates install
- add licenses in all PDF file
- add jumphost bridge in idf-pod1.yaml
- add network info in idf-pod1.yaml
- use eyaml decrypt IPMI user/passwd
- update node network&node name in pod1.yaml
Change-Id: Ia239d5d1ac261cc8b6e35dee6af8292b60884f0b
Signed-off-by: louie.long <longyu805@163.com>
-rw-r--r-- | labs/bii/idf-pod1.yaml | 64 | ||||
-rw-r--r-- | labs/bii/pod1.yaml | 296 |
2 files changed, 240 insertions, 120 deletions
diff --git a/labs/bii/idf-pod1.yaml b/labs/bii/idf-pod1.yaml index 8c358a9c..187f42ce 100644 --- a/labs/bii/idf-pod1.yaml +++ b/labs/bii/idf-pod1.yaml @@ -1,33 +1,71 @@ +############################################################################## +# Copyright (c) 2018 BII-CFIEC and others. +# All rights reserved. This program and the accompanying materials +# are made available under the terms of the Apache License, Version 2.0 +# which accompanies this distribution, and is available at +# http://www.apache.org/licenses/LICENSE-2.0 +############################################################################## --- ### This is a BII POD1 Installer descriptor file ### idf: version: 0.1 net_config: + oob: # IPMI management network + interface: 0 + ip-range: 192.168.20.200-192.168.20.205 + vlan: native admin: interface: 0 - vlan: 0 + vlan: native network: 10.20.0.0 mask: 24 - gateway: 10.20.0.1 - dns: 10.20.0.1 mgmt: - interface: 0 - vlan: 102 - network: 192.168.102.0 - mask: 24 - storage: - interface: 0 + interface: 2 vlan: 101 network: 192.168.101.0 mask: 24 private: - interface: 0 - vlan: 103 - network: 192.168.103.0 + interface: 3 + vlan: 102 + network: 192.168.102.0 mask: 24 public: interface: 1 - vlan: 0 + vlan: native network: 192.168.20.0 mask: 24 + gateway: 192.168.20.1 + dns: + - 114.114.114.114 + - 8.8.8.8 + fuel: + jumphost: + bridges: + admin: 'br-pxe' + mgmt: 'br-ctl' + private: ~ + public: ~ + network: + node: + # Ordered-list, index should be in sync with node index in PDF + - interfaces: &interfaces + # Ordered-list, index should be in sync with interface index in PDF + - 'eno1' + - 'eno2' + - 'eno3' + - 'eno4' + busaddr: &busaddr + # Bus-info reported by `ethtool -i ethX` + - '0000:01:00.0' + - '0000:01:00.1' + - '0000:02:00.0' + - '0000:02:00.1' + - interfaces: *interfaces + busaddr: *busaddr + - interfaces: *interfaces + busaddr: *busaddr + - interfaces: *interfaces + busaddr: *busaddr + - interfaces: *interfaces + busaddr: *busaddr diff --git a/labs/bii/pod1.yaml b/labs/bii/pod1.yaml index 117721b6..44eedc37 100644 --- a/labs/bii/pod1.yaml +++ b/labs/bii/pod1.yaml @@ -1,7 +1,15 @@ -### This is a BII POD1 descriptor file ### +############################################################################## +# Copyright (c) 2018 BII-CFIEC and others. +# All rights reserved. This program and the accompanying materials +# are made available under the terms of the Apache License, Version 2.0 +# which accompanies this distribution, and is available at +# http://www.apache.org/licenses/LICENSE-2.0 +############################################################################## --- +### This is a BII POD1 descriptor file ### + details: - pod_owner: ylong@BII + pod_owner: ylong contact: ylong@biigroup.cn, zjtang@biigroup.cn lab: BII Pharos LAB location: BDA, Beijing, China @@ -11,158 +19,232 @@ details: jumphost: name: fuel node: - type: baremetal # can be virtual or baremetal + type: baremetal vendor: Dell Inc. model: powerEdge 720 arch: x86_64 cpus: 2 - cpu_cflags: haswell # add values based on CFLAGS in GCC - cores: 8 # physical cores, not including hyper-threads + cpu_cflags: haswell + cores: 4 memory: 16G - disks: # disk list - - name: 'disk1' # first disk - disk_capacity: 300G # volume - disk_type: hdd # several disk types possible - disk_interface: sas # several interface types possible - disk_rotation: 15000 # define rotation speed of disk - - name: 'disk2' # second disk - disk_capacity: 300G - disk_type: hdd - disk_interface: sas - disk_rotation: 15000 - - name: 'disk3' # third disk - disk_capacity: 300G - disk_type: hdd - disk_interface: sas - disk_rotation: 15000 - - name: 'disk4' # fourth disk - disk_capacity: 300G + disks: + - name: 'disk1' + disk_capacity: 1100G disk_type: hdd disk_interface: sas disk_rotation: 15000 - - name: 'disk5' # fifth disk - disk_capacity: 300G - disk_type: hdd - disk_interface: sas - disk_rotation: 15000 - os: centos-7.3 # operation system installed + os: ubuntu-16.04 remote_params: &remote_params type: ipmi versions: - 2.0 - user: - pass: + user: > + ENC[PKCS7,MIIBeQYJKoZIhvcNAQcDoIIBajCCAWYCAQAxggEhMIIBHQIBADAFMAACAQEw + DQYJKoZIhvcNAQEBBQAEggEAUnK7YuVSij4ALxIM+562DzeMEk0TaCoAOAcq + vHfnXEGI6IVpLtA/5d8y+tcmy82azpcNAIRvIGT08iEPwxo/Sa8MIIB1QFd5 + mC2I+pMhbowXmCUlU3m7gxDvsOYVkUYfxswtQoKUFSnG2mAZQA8L2Vpfbc2V + fWOOQlsNuJ4g7eN22bpODUDi5XzdFuBNUhRYNGQwGre4OUM6Qb+5QyXN8hKA + rHo7bI+36WWQSTdZHKXr9sJviQsWqAYXDRNIthdUbb8FlkAUdtV65eUB36hB + 7KEjbjK8aMpsQIIOjCmc/LONIFzkrKC2nGWP83iG++aWnoXW+hHSO9bGhfrt + 41I3JjA8BgkqhkiG9w0BBwEwHQYJYIZIAWUDBAEqBBC+t7WDS6WRtLT3UTTx + wXGCgBBrhvF5qjnbDl55TN2fhb2k] + pass: > + ENC[PKCS7,MIIBeQYJKoZIhvcNAQcDoIIBajCCAWYCAQAxggEhMIIBHQIBADAFMAACAQEw + DQYJKoZIhvcNAQEBBQAEggEAtsyAgyyRp3U3uMkyG0tHSW0e1y7Qq3LCpIRs + E0K6745xTmVPMLzbL+8OpgBIieLFukZnWNoLtdoEfZlYbw4En5DSMpkkmWgi + 35329Bs2eIU4lNUtjFi6UvHMB+j+gvVpObRgn1EfC2ngbgognw94+aA2LBiZ + oWKIk7iRmtLTguZLd72mdV+a/Ukk7lMeYz4OF4c4myMZzk4c1F9L3VLYux0+ + xcbZw/WRZHgYg1YHONX2WNHTf91cyd282BG7rLNaY4mO7XWU9mpmqeWHjJ7N + fpwPEfwt8dJq2b+p0o1FDRyAEF375AmMfwqupDk33fecFj6elr4EMzeusrFh + RiV9wjA8BgkqhkiG9w0BBwEwHQYJYIZIAWUDBAEqBBABjHF90Ke9WX+NZGzZ + MUPLgBDJhm3lONPvX22d5DFMpoXy] remote_management: <<: *remote_params - address: 192.168.20.200 + address: 192.168.20.200/24 mac_address: "44:A8:42:1A:68:78" - interfaces: # physical interface list - - mac_address: "44:a8:42:15:10:03" - address: 10.20.0.2 - name: 'nic1' - - mac_address: "44:a8:42:15:10:04" - address: 192.168.20.5 - name: 'nic2' -################################################### + interfaces: + - name: 'nic1' + address: 10.10.0.2/24 + mac_address: "44:a8:42:15:10:03" + vlan: native + - name: 'nic2' + address: 192.168.20.5/24 + mac_address: "44:a8:42:15:10:04" + vlan: native + - name: 'nic3' + address: 192.168.101.2/24 + mac_address: "44:a8:42:15:10:05" + vlan: 101 + - name: 'nic4' + mac_address: "44:a8:42:15:10:06" nodes: - - name: compute1 + - name: pod1-ctl01 node: &nodeparas type: baremetal vendor: Dell Inc. model: powerEdge 720 arch: x86_64 cpus: 2 - cpu_cflags: haswell # add values based on CFLAGS in GCC - cores: 8 # physical cores, not including hyper-threads + cpu_cflags: haswell + cores: 4 memory: 32G - disks: &disks_A # disk list - - name: 'disk1' # first disk - disk_capacity: 128G # volume - disk_type: ssd # several disk types possible - disk_interface: sas # several interface types possible - disk_rotation: 15000 # define rotation speed of disk - - name: 'disk2' # second disk - disk_capacity: 600G - disk_type: hdd - disk_interface: sas - disk_rotation: 15000 - - name: 'disk3' # third disk - disk_capacity: 600G - disk_type: hdd - disk_interface: sas - disk_rotation: 15000 - - name: 'disk4' # fourth disk - disk_capacity: 600G - disk_type: hdd + disks: &disks_A + - name: 'disk1' + disk_capacity: 128G + disk_type: ssd disk_interface: sas disk_rotation: 15000 - - name: 'disk5' # fifth disk - disk_capacity: 600G + - name: 'disk2' + disk_capacity: 2400G disk_type: hdd disk_interface: sas disk_rotation: 15000 remote_management: <<: *remote_params - address: 192.168.20.201 - mac_address: "44:A8:42:1A:70:BE" - interfaces: # physical interface list - - mac_address: "44:a8:42:14:ee:64" - address: 10.20.0.4 - name: 'nic1' - ######################################## - - name: compute2 + address: 192.168.20.203/24 + mac_address: "44:A8:42:1A:49:A5" + interfaces: + - name: 'nic1' + speed: 1gb + features: '' + address: 10.20.0.16/24 + mac_address: "44:a8:42:14:cd:0d" + vlan: native + - name: 'nic2' + speed: 1gb + features: '' + address: 192.168.20.16/24 + mac_address: "44:a8:42:14:cd:0e" + vlan: native + - name: 'nic3' + speed: 1gb + features: '' + address: 192.168.101.16/24 + mac_address: "44:a8:42:14:cd:0f" + vlan: 101 + - name: 'nic4' + speed: 1gb + features: '' + mac_address: "44:a8:42:14:cd:10" + - name: pod1-ctl02 node: *nodeparas disks: *disks_A remote_management: <<: *remote_params - address: 192.168.20.202 - mac_address: "44:A8:42:1A:76:26" + address: 192.168.20.204/24 + mac_address: "44:A8:42:1A:76:2C" interfaces: - - mac_address: "44:a8:42:14:cb:31" - address: 10.20.0.5 - name: 'nic1' - ######################################## - - name: controller1 + - name: 'nic1' + speed: 1gb + features: '' + address: 10.20.0.17/24 + mac_address: "44:a8:42:15:1b:e6" + vlan: native + - name: 'nic2' + speed: 1gb + features: '' + address: 192.168.20.17/24 + mac_address: "44:a8:42:15:1b:e7" + vlan: native + - name: 'nic3' + speed: 1gb + features: '' + address: 192.168.101.16/24 + mac_address: "44:a8:42:15:1b:e8" + vlan: 101 + - name: 'nic4' + speed: 1gb + features: '' + mac_address: "44:a8:42:15:1b:e9" + - name: pod1-ctl03 node: *nodeparas disks: *disks_A remote_management: <<: *remote_params - address: 192.168.20.203 - mac_address: "44:A8:42:1A:49:A5" + address: 192.168.20.205/24 + mac_address: "44:A8:42:13:D5:1B" interfaces: - - mac_address: "44:a8:42:14:cd:0d" - address: 10.20.0.6 - name: 'nic1' - - mac_address: "44:a8:42:14:cd:0e" - address: 192.168.20.12 - name: 'nic2' - ######################################## - - name: controller2 + - name: 'nic1' + speed: 1gb + features: '' + address: 10.20.0.18/24 + mac_address: "44:a8:42:14:fc:1a" + vlan: native + - name: 'nic2' + speed: 1gb + features: '' + address: 192.168.20.18/24 + mac_address: "44:a8:42:14:fc:1b" + vlan: native + - name: 'nic3' + speed: 1gb + features: '' + address: 192.168.101.18/24 + mac_address: "44:a8:42:14:fc:1c" + vlan: 101 + - name: 'nic4' + speed: 1gb + features: '' + mac_address: "44:a8:42:14:fc:1d" + - name: pod1-cmp01 node: *nodeparas disks: *disks_A remote_management: <<: *remote_params - address: 192.168.20.204 - mac_address: "44:A8:42:1A:76:2C" + address: 192.168.20.201/24 + mac_address: "44:A8:42:1A:70:BE" interfaces: - - mac_address: "44:a8:42:15:1b:e6" - address: 10.20.0.7 - name: 'nic1' - - mac_address: "44:a8:42:15:1b:e7" - address: 192.168.20.13 - name: 'nic2' - ######################################## - - name: controller3 + - name: 'nic1' + speed: 1gb + features: '' + address: 10.20.0.14/24 + mac_address: "44:a8:42:14:ee:64" + vlan: native + - name: 'nic2' + speed: 1gb + features: '' + address: 192.168.20.14/24 + mac_address: "44:a8:42:14:ee:65" + vlan: native + - name: 'nic3' + speed: 1gb + features: '' + address: 192.168.101.14/24 + mac_address: "44:a8:42:14:ee:66" + vlan: 101 + - name: 'nic4' + speed: 1gb + features: '' + mac_address: "44:a8:42:14:ee:67" + vlan: 102 + - name: pod1-cmp02 node: *nodeparas disks: *disks_A remote_management: <<: *remote_params - address: 192.168.20.205 - mac_address: "44:A8:42:13:D5:1B" + address: 192.168.20.202/24 + mac_address: "44:A8:42:1A:76:26" interfaces: - - mac_address: "44:a8:42:14:fc:1a" - address: 10.20.0.8 - name: 'nic1' - - mac_address: "44:a8:42:14:fc:1b" - address: 192.168.20.14 - name: 'nic2' + - name: 'nic1' + speed: 1gb + features: '' + address: 10.20.0.13/24 + mac_address: "44:a8:42:14:cb:31" + vlan: native + - name: 'nic2' + speed: 1gb + features: '' + address: 192.168.20.13/24 + mac_address: "44:a8:42:14:cb:32" + vlan: native + - name: 'nic3' + speed: 1gb + features: '' + address: 192.168.101.13/24 + mac_address: "44:a8:42:14:cb:33" + vlan: 101 + - name: 'nic4' + speed: 1gb + features: '' + mac_address: "44:a8:42:14:cb:34" + vlan: 102 |