1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
|
Memory mapped SJA1000 CAN controller from NXP (formerly Philips)
Required properties:
- compatible : should be "nxp,sja1000".
- reg : should specify the chip select, address offset and size required
to map the registers of the SJA1000. The size is usually 0x80.
- interrupts: property with a value describing the interrupt source
(number and sensitivity) required for the SJA1000.
Optional properties:
- reg-io-width : Specify the size (in bytes) of the IO accesses that
should be performed on the device. Valid value is 1, 2 or 4.
Default to 1 (8 bits).
- nxp,external-clock-frequency : Frequency of the external oscillator
clock in Hz. Note that the internal clock frequency used by the
SJA1000 is half of that value. If not specified, a default value
of 16000000 (16 MHz) is used.
- nxp,tx-output-mode : operation mode of the TX output control logic:
<0x0> : bi-phase output mode
<0x1> : normal output mode (default)
<0x2> : test output mode
<0x3> : clock output mode
- nxp,tx-output-config : TX output pin configuration:
<0x01> : TX0 invert
<0x02> : TX0 pull-down (default)
<0x04> : TX0 pull-up
<0x06> : TX0 push-pull
<0x08> : TX1 invert
<0x10> : TX1 pull-down
<0x20> : TX1 pull-up
<0x30> : TX1 push-pull
- nxp,clock-out-frequency : clock frequency in Hz on the CLKOUT pin.
If not specified or if the specified value is 0, the CLKOUT pin
will be disabled.
- nxp,no-comparator-bypass : Allows to disable the CAN input comparator.
For further information, please have a look to the SJA1000 data sheet.
Examples:
can@3,100 {
compatible = "nxp,sja1000";
reg = <3 0x100 0x80>;
interrupts = <2 0>;
interrupt-parent = <&mpic>;
nxp,external-clock-frequency = <16000000>;
};
|