diff options
author | José Pekkarinen <jose.pekkarinen@nokia.com> | 2016-04-11 10:41:07 +0300 |
---|---|---|
committer | José Pekkarinen <jose.pekkarinen@nokia.com> | 2016-04-13 08:17:18 +0300 |
commit | e09b41010ba33a20a87472ee821fa407a5b8da36 (patch) | |
tree | d10dc367189862e7ca5c592f033dc3726e1df4e3 /kernel/include/linux/cpu_cooling.h | |
parent | f93b97fd65072de626c074dbe099a1fff05ce060 (diff) |
These changes are the raw update to linux-4.4.6-rt14. Kernel sources
are taken from kernel.org, and rt patch from the rt wiki download page.
During the rebasing, the following patch collided:
Force tick interrupt and get rid of softirq magic(I70131fb85).
Collisions have been removed because its logic was found on the
source already.
Change-Id: I7f57a4081d9deaa0d9ccfc41a6c8daccdee3b769
Signed-off-by: José Pekkarinen <jose.pekkarinen@nokia.com>
Diffstat (limited to 'kernel/include/linux/cpu_cooling.h')
-rw-r--r-- | kernel/include/linux/cpu_cooling.h | 39 |
1 files changed, 39 insertions, 0 deletions
diff --git a/kernel/include/linux/cpu_cooling.h b/kernel/include/linux/cpu_cooling.h index bd955270d..c156f5082 100644 --- a/kernel/include/linux/cpu_cooling.h +++ b/kernel/include/linux/cpu_cooling.h @@ -28,6 +28,9 @@ #include <linux/thermal.h> #include <linux/cpumask.h> +typedef int (*get_static_t)(cpumask_t *cpumask, int interval, + unsigned long voltage, u32 *power); + #ifdef CONFIG_CPU_THERMAL /** * cpufreq_cooling_register - function to create cpufreq cooling device. @@ -36,6 +39,10 @@ struct thermal_cooling_device * cpufreq_cooling_register(const struct cpumask *clip_cpus); +struct thermal_cooling_device * +cpufreq_power_cooling_register(const struct cpumask *clip_cpus, + u32 capacitance, get_static_t plat_static_func); + /** * of_cpufreq_cooling_register - create cpufreq cooling device based on DT. * @np: a valid struct device_node to the cooling device device tree node. @@ -45,6 +52,12 @@ cpufreq_cooling_register(const struct cpumask *clip_cpus); struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, const struct cpumask *clip_cpus); + +struct thermal_cooling_device * +of_cpufreq_power_cooling_register(struct device_node *np, + const struct cpumask *clip_cpus, + u32 capacitance, + get_static_t plat_static_func); #else static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, @@ -52,6 +65,15 @@ of_cpufreq_cooling_register(struct device_node *np, { return ERR_PTR(-ENOSYS); } + +static inline struct thermal_cooling_device * +of_cpufreq_power_cooling_register(struct device_node *np, + const struct cpumask *clip_cpus, + u32 capacitance, + get_static_t plat_static_func) +{ + return NULL; +} #endif /** @@ -68,11 +90,28 @@ cpufreq_cooling_register(const struct cpumask *clip_cpus) return ERR_PTR(-ENOSYS); } static inline struct thermal_cooling_device * +cpufreq_power_cooling_register(const struct cpumask *clip_cpus, + u32 capacitance, get_static_t plat_static_func) +{ + return NULL; +} + +static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, const struct cpumask *clip_cpus) { return ERR_PTR(-ENOSYS); } + +static inline struct thermal_cooling_device * +of_cpufreq_power_cooling_register(struct device_node *np, + const struct cpumask *clip_cpus, + u32 capacitance, + get_static_t plat_static_func) +{ + return NULL; +} + static inline void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) { |