summaryrefslogtreecommitdiffstats
path: root/kernel/drivers/thermal/cpu_cooling.c
diff options
context:
space:
mode:
authorYunhong Jiang <yunhong.jiang@intel.com>2015-08-04 12:17:53 -0700
committerYunhong Jiang <yunhong.jiang@intel.com>2015-08-04 15:44:42 -0700
commit9ca8dbcc65cfc63d6f5ef3312a33184e1d726e00 (patch)
tree1c9cafbcd35f783a87880a10f85d1a060db1a563 /kernel/drivers/thermal/cpu_cooling.c
parent98260f3884f4a202f9ca5eabed40b1354c489b29 (diff)
Add the rt linux 4.1.3-rt3 as base
Import the rt linux 4.1.3-rt3 as OPNFV kvm base. It's from git://git.kernel.org/pub/scm/linux/kernel/git/rt/linux-rt-devel.git linux-4.1.y-rt and the base is: commit 0917f823c59692d751951bf5ea699a2d1e2f26a2 Author: Sebastian Andrzej Siewior <bigeasy@linutronix.de> Date: Sat Jul 25 12:13:34 2015 +0200 Prepare v4.1.3-rt3 Signed-off-by: Sebastian Andrzej Siewior <bigeasy@linutronix.de> We lose all the git history this way and it's not good. We should apply another opnfv project repo in future. Change-Id: I87543d81c9df70d99c5001fbdf646b202c19f423 Signed-off-by: Yunhong Jiang <yunhong.jiang@intel.com>
Diffstat (limited to 'kernel/drivers/thermal/cpu_cooling.c')
-rw-r--r--kernel/drivers/thermal/cpu_cooling.c481
1 files changed, 481 insertions, 0 deletions
diff --git a/kernel/drivers/thermal/cpu_cooling.c b/kernel/drivers/thermal/cpu_cooling.c
new file mode 100644
index 000000000..f65f0d109
--- /dev/null
+++ b/kernel/drivers/thermal/cpu_cooling.c
@@ -0,0 +1,481 @@
+/*
+ * linux/drivers/thermal/cpu_cooling.c
+ *
+ * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
+ * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
+ *
+ * Copyright (C) 2014 Viresh Kumar <viresh.kumar@linaro.org>
+ *
+ * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+ * This program is free software; you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License as published by
+ * the Free Software Foundation; version 2 of the License.
+ *
+ * This program is distributed in the hope that it will be useful, but
+ * WITHOUT ANY WARRANTY; without even the implied warranty of
+ * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
+ * General Public License for more details.
+ *
+ * You should have received a copy of the GNU General Public License along
+ * with this program; if not, write to the Free Software Foundation, Inc.,
+ * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
+ *
+ * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+ */
+#include <linux/module.h>
+#include <linux/thermal.h>
+#include <linux/cpufreq.h>
+#include <linux/err.h>
+#include <linux/slab.h>
+#include <linux/cpu.h>
+#include <linux/cpu_cooling.h>
+
+/*
+ * Cooling state <-> CPUFreq frequency
+ *
+ * Cooling states are translated to frequencies throughout this driver and this
+ * is the relation between them.
+ *
+ * Highest cooling state corresponds to lowest possible frequency.
+ *
+ * i.e.
+ * level 0 --> 1st Max Freq
+ * level 1 --> 2nd Max Freq
+ * ...
+ */
+
+/**
+ * struct cpufreq_cooling_device - data for cooling device with cpufreq
+ * @id: unique integer value corresponding to each cpufreq_cooling_device
+ * registered.
+ * @cool_dev: thermal_cooling_device pointer to keep track of the
+ * registered cooling device.
+ * @cpufreq_state: integer value representing the current state of cpufreq
+ * cooling devices.
+ * @cpufreq_val: integer value representing the absolute value of the clipped
+ * frequency.
+ * @max_level: maximum cooling level. One less than total number of valid
+ * cpufreq frequencies.
+ * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device.
+ * @node: list_head to link all cpufreq_cooling_device together.
+ *
+ * This structure is required for keeping information of each registered
+ * cpufreq_cooling_device.
+ */
+struct cpufreq_cooling_device {
+ int id;
+ struct thermal_cooling_device *cool_dev;
+ unsigned int cpufreq_state;
+ unsigned int cpufreq_val;
+ unsigned int max_level;
+ unsigned int *freq_table; /* In descending order */
+ struct cpumask allowed_cpus;
+ struct list_head node;
+};
+static DEFINE_IDR(cpufreq_idr);
+static DEFINE_MUTEX(cooling_cpufreq_lock);
+
+static LIST_HEAD(cpufreq_dev_list);
+
+/**
+ * get_idr - function to get a unique id.
+ * @idr: struct idr * handle used to create a id.
+ * @id: int * value generated by this function.
+ *
+ * This function will populate @id with an unique
+ * id, using the idr API.
+ *
+ * Return: 0 on success, an error code on failure.
+ */
+static int get_idr(struct idr *idr, int *id)
+{
+ int ret;
+
+ mutex_lock(&cooling_cpufreq_lock);
+ ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL);
+ mutex_unlock(&cooling_cpufreq_lock);
+ if (unlikely(ret < 0))
+ return ret;
+ *id = ret;
+
+ return 0;
+}
+
+/**
+ * release_idr - function to free the unique id.
+ * @idr: struct idr * handle used for creating the id.
+ * @id: int value representing the unique id.
+ */
+static void release_idr(struct idr *idr, int id)
+{
+ mutex_lock(&cooling_cpufreq_lock);
+ idr_remove(idr, id);
+ mutex_unlock(&cooling_cpufreq_lock);
+}
+
+/* Below code defines functions to be used for cpufreq as cooling device */
+
+/**
+ * get_level: Find the level for a particular frequency
+ * @cpufreq_dev: cpufreq_dev for which the property is required
+ * @freq: Frequency
+ *
+ * Return: level on success, THERMAL_CSTATE_INVALID on error.
+ */
+static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_dev,
+ unsigned int freq)
+{
+ unsigned long level;
+
+ for (level = 0; level <= cpufreq_dev->max_level; level++) {
+ if (freq == cpufreq_dev->freq_table[level])
+ return level;
+
+ if (freq > cpufreq_dev->freq_table[level])
+ break;
+ }
+
+ return THERMAL_CSTATE_INVALID;
+}
+
+/**
+ * cpufreq_cooling_get_level - for a given cpu, return the cooling level.
+ * @cpu: cpu for which the level is required
+ * @freq: the frequency of interest
+ *
+ * This function will match the cooling level corresponding to the
+ * requested @freq and return it.
+ *
+ * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
+ * otherwise.
+ */
+unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
+{
+ struct cpufreq_cooling_device *cpufreq_dev;
+
+ mutex_lock(&cooling_cpufreq_lock);
+ list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+ if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
+ mutex_unlock(&cooling_cpufreq_lock);
+ return get_level(cpufreq_dev, freq);
+ }
+ }
+ mutex_unlock(&cooling_cpufreq_lock);
+
+ pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
+ return THERMAL_CSTATE_INVALID;
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
+
+/**
+ * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
+ * @nb: struct notifier_block * with callback info.
+ * @event: value showing cpufreq event for which this function invoked.
+ * @data: callback-specific data
+ *
+ * Callback to hijack the notification on cpufreq policy transition.
+ * Every time there is a change in policy, we will intercept and
+ * update the cpufreq policy with thermal constraints.
+ *
+ * Return: 0 (success)
+ */
+static int cpufreq_thermal_notifier(struct notifier_block *nb,
+ unsigned long event, void *data)
+{
+ struct cpufreq_policy *policy = data;
+ unsigned long max_freq = 0;
+ struct cpufreq_cooling_device *cpufreq_dev;
+
+ if (event != CPUFREQ_ADJUST)
+ return 0;
+
+ mutex_lock(&cooling_cpufreq_lock);
+ list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+ if (!cpumask_test_cpu(policy->cpu,
+ &cpufreq_dev->allowed_cpus))
+ continue;
+
+ max_freq = cpufreq_dev->cpufreq_val;
+
+ if (policy->max != max_freq)
+ cpufreq_verify_within_limits(policy, 0, max_freq);
+ }
+ mutex_unlock(&cooling_cpufreq_lock);
+
+ return 0;
+}
+
+/* cpufreq cooling device callback functions are defined below */
+
+/**
+ * cpufreq_get_max_state - callback function to get the max cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: fill this variable with the max cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * max cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
+ unsigned long *state)
+{
+ struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
+
+ *state = cpufreq_device->max_level;
+ return 0;
+}
+
+/**
+ * cpufreq_get_cur_state - callback function to get the current cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: fill this variable with the current cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
+ unsigned long *state)
+{
+ struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
+
+ *state = cpufreq_device->cpufreq_state;
+
+ return 0;
+}
+
+/**
+ * cpufreq_set_cur_state - callback function to set the current cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: set this variable to the current cooling state.
+ *
+ * Callback for the thermal cooling device to change the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
+ unsigned long state)
+{
+ struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
+ unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);
+ unsigned int clip_freq;
+
+ /* Request state should be less than max_level */
+ if (WARN_ON(state > cpufreq_device->max_level))
+ return -EINVAL;
+
+ /* Check if the old cooling action is same as new cooling action */
+ if (cpufreq_device->cpufreq_state == state)
+ return 0;
+
+ clip_freq = cpufreq_device->freq_table[state];
+ cpufreq_device->cpufreq_state = state;
+ cpufreq_device->cpufreq_val = clip_freq;
+
+ cpufreq_update_policy(cpu);
+
+ return 0;
+}
+
+/* Bind cpufreq callbacks to thermal cooling device ops */
+static struct thermal_cooling_device_ops const cpufreq_cooling_ops = {
+ .get_max_state = cpufreq_get_max_state,
+ .get_cur_state = cpufreq_get_cur_state,
+ .set_cur_state = cpufreq_set_cur_state,
+};
+
+/* Notifier for cpufreq policy change */
+static struct notifier_block thermal_cpufreq_notifier_block = {
+ .notifier_call = cpufreq_thermal_notifier,
+};
+
+static unsigned int find_next_max(struct cpufreq_frequency_table *table,
+ unsigned int prev_max)
+{
+ struct cpufreq_frequency_table *pos;
+ unsigned int max = 0;
+
+ cpufreq_for_each_valid_entry(pos, table) {
+ if (pos->frequency > max && pos->frequency < prev_max)
+ max = pos->frequency;
+ }
+
+ return max;
+}
+
+/**
+ * __cpufreq_cooling_register - helper function to create cpufreq cooling device
+ * @np: a valid struct device_node to the cooling device device tree node
+ * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ * Normally this should be same as cpufreq policy->related_cpus.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices. It also gives the opportunity to link the cooling device
+ * with a device tree node, in order to bind it via the thermal DT code.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
+ */
+static struct thermal_cooling_device *
+__cpufreq_cooling_register(struct device_node *np,
+ const struct cpumask *clip_cpus)
+{
+ struct thermal_cooling_device *cool_dev;
+ struct cpufreq_cooling_device *cpufreq_dev;
+ char dev_name[THERMAL_NAME_LENGTH];
+ struct cpufreq_frequency_table *pos, *table;
+ unsigned int freq, i;
+ int ret;
+
+ table = cpufreq_frequency_get_table(cpumask_first(clip_cpus));
+ if (!table) {
+ pr_debug("%s: CPUFreq table not found\n", __func__);
+ return ERR_PTR(-EPROBE_DEFER);
+ }
+
+ cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
+ if (!cpufreq_dev)
+ return ERR_PTR(-ENOMEM);
+
+ /* Find max levels */
+ cpufreq_for_each_valid_entry(pos, table)
+ cpufreq_dev->max_level++;
+
+ cpufreq_dev->freq_table = kmalloc(sizeof(*cpufreq_dev->freq_table) *
+ cpufreq_dev->max_level, GFP_KERNEL);
+ if (!cpufreq_dev->freq_table) {
+ cool_dev = ERR_PTR(-ENOMEM);
+ goto free_cdev;
+ }
+
+ /* max_level is an index, not a counter */
+ cpufreq_dev->max_level--;
+
+ cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
+
+ ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
+ if (ret) {
+ cool_dev = ERR_PTR(ret);
+ goto free_table;
+ }
+
+ snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
+ cpufreq_dev->id);
+
+ cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
+ &cpufreq_cooling_ops);
+ if (IS_ERR(cool_dev))
+ goto remove_idr;
+
+ /* Fill freq-table in descending order of frequencies */
+ for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
+ freq = find_next_max(table, freq);
+ cpufreq_dev->freq_table[i] = freq;
+
+ /* Warn for duplicate entries */
+ if (!freq)
+ pr_warn("%s: table has duplicate entries\n", __func__);
+ else
+ pr_debug("%s: freq:%u KHz\n", __func__, freq);
+ }
+
+ cpufreq_dev->cpufreq_val = cpufreq_dev->freq_table[0];
+ cpufreq_dev->cool_dev = cool_dev;
+
+ mutex_lock(&cooling_cpufreq_lock);
+
+ /* Register the notifier for first cpufreq cooling device */
+ if (list_empty(&cpufreq_dev_list))
+ cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
+ CPUFREQ_POLICY_NOTIFIER);
+ list_add(&cpufreq_dev->node, &cpufreq_dev_list);
+
+ mutex_unlock(&cooling_cpufreq_lock);
+
+ return cool_dev;
+
+remove_idr:
+ release_idr(&cpufreq_idr, cpufreq_dev->id);
+free_table:
+ kfree(cpufreq_dev->freq_table);
+free_cdev:
+ kfree(cpufreq_dev);
+
+ return cool_dev;
+}
+
+/**
+ * cpufreq_cooling_register - function to create cpufreq cooling device.
+ * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
+ */
+struct thermal_cooling_device *
+cpufreq_cooling_register(const struct cpumask *clip_cpus)
+{
+ return __cpufreq_cooling_register(NULL, clip_cpus);
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
+
+/**
+ * of_cpufreq_cooling_register - function to create cpufreq cooling device.
+ * @np: a valid struct device_node to the cooling device device tree node
+ * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices. Using this API, the cpufreq cooling device will be
+ * linked to the device tree node provided.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
+ */
+struct thermal_cooling_device *
+of_cpufreq_cooling_register(struct device_node *np,
+ const struct cpumask *clip_cpus)
+{
+ if (!np)
+ return ERR_PTR(-EINVAL);
+
+ return __cpufreq_cooling_register(np, clip_cpus);
+}
+EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
+
+/**
+ * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
+ * @cdev: thermal cooling device pointer.
+ *
+ * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
+ */
+void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
+{
+ struct cpufreq_cooling_device *cpufreq_dev;
+
+ if (!cdev)
+ return;
+
+ cpufreq_dev = cdev->devdata;
+ mutex_lock(&cooling_cpufreq_lock);
+ list_del(&cpufreq_dev->node);
+
+ /* Unregister the notifier for the last cpufreq cooling device */
+ if (list_empty(&cpufreq_dev_list))
+ cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
+ CPUFREQ_POLICY_NOTIFIER);
+ mutex_unlock(&cooling_cpufreq_lock);
+
+ thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
+ release_idr(&cpufreq_idr, cpufreq_dev->id);
+ kfree(cpufreq_dev->freq_table);
+ kfree(cpufreq_dev);
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);