diff options
author | Yunhong Jiang <yunhong.jiang@intel.com> | 2015-08-04 12:17:53 -0700 |
---|---|---|
committer | Yunhong Jiang <yunhong.jiang@intel.com> | 2015-08-04 15:44:42 -0700 |
commit | 9ca8dbcc65cfc63d6f5ef3312a33184e1d726e00 (patch) | |
tree | 1c9cafbcd35f783a87880a10f85d1a060db1a563 /kernel/Documentation/hwmon/f71882fg | |
parent | 98260f3884f4a202f9ca5eabed40b1354c489b29 (diff) |
Add the rt linux 4.1.3-rt3 as base
Import the rt linux 4.1.3-rt3 as OPNFV kvm base.
It's from git://git.kernel.org/pub/scm/linux/kernel/git/rt/linux-rt-devel.git linux-4.1.y-rt and
the base is:
commit 0917f823c59692d751951bf5ea699a2d1e2f26a2
Author: Sebastian Andrzej Siewior <bigeasy@linutronix.de>
Date: Sat Jul 25 12:13:34 2015 +0200
Prepare v4.1.3-rt3
Signed-off-by: Sebastian Andrzej Siewior <bigeasy@linutronix.de>
We lose all the git history this way and it's not good. We
should apply another opnfv project repo in future.
Change-Id: I87543d81c9df70d99c5001fbdf646b202c19f423
Signed-off-by: Yunhong Jiang <yunhong.jiang@intel.com>
Diffstat (limited to 'kernel/Documentation/hwmon/f71882fg')
-rw-r--r-- | kernel/Documentation/hwmon/f71882fg | 138 |
1 files changed, 138 insertions, 0 deletions
diff --git a/kernel/Documentation/hwmon/f71882fg b/kernel/Documentation/hwmon/f71882fg new file mode 100644 index 000000000..de91c0db5 --- /dev/null +++ b/kernel/Documentation/hwmon/f71882fg @@ -0,0 +1,138 @@ +Kernel driver f71882fg +====================== + +Supported chips: + * Fintek F71808E + Prefix: 'f71808e' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Not public + * Fintek F71808A + Prefix: 'f71808a' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Not public + * Fintek F71858FG + Prefix: 'f71858fg' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + * Fintek F71862FG and F71863FG + Prefix: 'f71862fg' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + * Fintek F71869F and F71869E + Prefix: 'f71869' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + * Fintek F71869A + Prefix: 'f71869a' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Not public + * Fintek F71882FG and F71883FG + Prefix: 'f71882fg' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + * Fintek F71889FG + Prefix: 'f71889fg' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + * Fintek F71889ED + Prefix: 'f71889ed' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Should become available on the Fintek website soon + * Fintek F71889A + Prefix: 'f71889a' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Should become available on the Fintek website soon + * Fintek F8000 + Prefix: 'f8000' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Not public + * Fintek F81801U + Prefix: 'f71889fg' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Not public + Note: This is the 64-pin variant of the F71889FG, they have the + same device ID and are fully compatible as far as hardware + monitoring is concerned. + * Fintek F81865F + Prefix: 'f81865f' + Addresses scanned: none, address read from Super I/O config space + Datasheet: Available from the Fintek website + +Author: Hans de Goede <hdegoede@redhat.com> + + +Description +----------- + +Fintek F718xx/F8000 Super I/O chips include complete hardware monitoring +capabilities. They can monitor up to 9 voltages, 4 fans and 3 temperature +sensors. + +These chips also have fan controlling features, using either DC or PWM, in +three different modes (one manual, two automatic). + +The driver assumes that no more than one chip is present, which seems +reasonable. + + +Monitoring +---------- + +The Voltage, Fan and Temperature Monitoring uses the standard sysfs +interface as documented in sysfs-interface, without any exceptions. + + +Fan Control +----------- + +Both PWM (pulse-width modulation) and DC fan speed control methods are +supported. The right one to use depends on external circuitry on the +motherboard, so the driver assumes that the BIOS set the method +properly. + +Note that the lowest numbered temperature zone trip point corresponds to +to the border between the highest and one but highest temperature zones, and +vica versa. So the temperature zone trip points 1-4 (or 1-2) go from high temp +to low temp! This is how things are implemented in the IC, and the driver +mimicks this. + +There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC +voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM +mode where the actual RPM of the fan (as measured) is controlled and the speed +gets specified as 0-100% of the fan#_full_speed file. + +Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a +whole lot of a difference when modifying fan control settings. The only +important difference is that in RPM mode the 0-100% controls the fan speed +between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs +RPM mode, it will also set fan#_full_speed properly, if it does not then +fan control will not work properly, unless you set a sane fan#_full_speed +value yourself. + +Switching between these modes requires re-initializing a whole bunch of +registers, so the mode which the BIOS has set is kept. The mode is +printed when loading the driver. + +Three different fan control modes are supported; the mode number is written +to the pwm#_enable file. Note that not all modes are supported on all +chips, and some modes may only be available in RPM / PWM mode. +Writing an unsupported mode will result in an invalid parameter error. + +* 1: Manual mode + You ask for a specific PWM duty cycle / DC voltage or a specific % of + fan#_full_speed by writing to the pwm# file. This mode is only + available on the F71858FG / F8000 if the fan channel is in RPM mode. + +* 2: Normal auto mode + You can define a number of temperature/fan speed trip points, which % the + fan should run at at this temp and which temp a fan should follow using the + standard sysfs interface. The number and type of trip points is chip + depended, see which files are available in sysfs. + Fan/PWM channel 3 of the F8000 is always in this mode! + +* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode) + The fan speed is regulated to keep the temp the fan is mapped to between + temp#_auto_point2_temp and temp#_auto_point3_temp. + +All of the automatic modes require that pwm1 corresponds to fan1, pwm2 to +fan2 and pwm3 to fan3. |