diff options
author | Linda Wang <wangwulin@huawei.com> | 2017-10-10 11:29:42 +0000 |
---|---|---|
committer | Morgan Richomme <morgan.richomme@orange.com> | 2017-10-10 15:48:20 +0200 |
commit | 79140281403a83ecfededbd1b58bf668bd4d1901 (patch) | |
tree | d0859de87cf28618ba485ac30caaa74aaa6b5281 /docs/testing/user/userguide/test_details.rst | |
parent | 9bae267d1f7bde0b433632de7166a1ff06ef4603 (diff) |
Fix the format issue of documentation
Also update the structure of functest code.
Change-Id: Id3fa012d6c3204a0a8d7e6e4ba3159c52b68c6f5
Signed-off-by: Linda Wang <wangwulin@huawei.com>
Diffstat (limited to 'docs/testing/user/userguide/test_details.rst')
-rw-r--r-- | docs/testing/user/userguide/test_details.rst | 45 |
1 files changed, 23 insertions, 22 deletions
diff --git a/docs/testing/user/userguide/test_details.rst b/docs/testing/user/userguide/test_details.rst index c9ef63d3..56cdd3b6 100644 --- a/docs/testing/user/userguide/test_details.rst +++ b/docs/testing/user/userguide/test_details.rst @@ -426,28 +426,29 @@ The Clearwater architecture is described as follows: :align: center :alt: vIMS architecture - cloudify_ims_perf - ^^^^^^^^^^^^ - This testcase extends the cloudify_ims test case. - The first part is similar but the testing part is different. - The testing part consists in automating a realistic signaling load on the vIMS - using an Ixia loader (proprietary tools) - - You need to have access to an Ixia licence server - defined in the configuration file. - - To start this test you need to have access to an Ixia licence server and have ixia image locally - - - case_name: cloudify_ims_perf - project_name: functest - criteria: 100 - blocking: false - description: '' - dependencies: - installer: '' - scenario: 'o' - run: - module: 'functest.opnfv_tests.vnf.ims.cloudify_ims_perf' - class: 'CloudifyImsPerf' + +cloudify_ims_perf +^^^^^^^^^^^^^^^^^ +This testcase extends the cloudify_ims test case. +The first part is similar but the testing part is different. +The testing part consists in automating a realistic signaling load on the vIMS +using an Ixia loader (proprietary tools) + - You need to have access to an Ixia licence server defined in the configuration + file. + +To start this test you need to have access to an Ixia licence server and have ixia image locally + - + case_name: cloudify_ims_perf + project_name: functest + criteria: 100 + blocking: false + description: '' + dependencies: + installer: '' + scenario: '' + run: + module: 'functest.opnfv_tests.vnf.ims.cloudify_ims_perf' + class: 'CloudifyImsPerf' orchestra_openims ^^^^^^^^^^^^^^^^^ |