aboutsummaryrefslogtreecommitdiffstats
path: root/mcp/reclass/classes/cluster/all-mcp-ocata-common/opnfv
AgeCommit message (Collapse)AuthorFilesLines
2017-09-25Fix or silence all yamllint warningsAlexandru Avadanii2-2/+4
Change-Id: Iface28ab770beee00374afb902ef4f9c983538f5 Signed-off-by: Alexandru Avadanii <Alexandru.Avadanii@enea.com>
2017-09-23reclass: Drop MaaS public IP and interfaceAlexandru Avadanii1-3/+2
MaaS node does not need to be exposed to the public network; instead the management IP should be enough to access the MaaS dashboard. So, drop 'infra_maas_node01_external_address' reclass param, together with its OPNFV PDF param, 'opnfv_infra_maas_node01_external_address'. This allows us to move compute public IPs back to .{2,3} instead of .{101,102}, where we moved them during 'pod_config.yml' addition. While at it, fix a minor duplicate 'name' param for 'br-mgmt' bridge on kvm nodes. Change-Id: Ie9fcf5924d7aa37b666f42c968687d73b51a8278 Signed-off-by: Alexandru Avadanii <Alexandru.Avadanii@enea.com>
2017-09-23reclass: pod_config: Revert MaaS IPs to .3Alexandru Avadanii1-3/+3
PDF compatible reclass support moved the MaaS IPs from .2 to .3. However, the runtime template was not updated accordingly, leading to mismatches between IP addresses. Until all scenarios support pod_config, we can't apply the IP change correctly, so revert it. Change-Id: I34e42ec06dd9fd4f69bd7c91dbe068a4f83b3e62 Signed-off-by: Alexandru Avadanii <Alexandru.Avadanii@enea.com>
2017-09-21Pod Descriptor File compatible reclass structureGuillermo Herrero3-5/+99
Implementation for baremetal-mcp-ocata-ovs-ha scenario JIRA: FUEL-275 Change-Id: Id6ab5697f993ac9faa019c3c10ba4ed4b7b6db01 Signed-off-by: Guillermo Herrero <guillermo.herrero@enea.com>
2017-09-12reclass, states: Parametrize runtime configurationAlexandru Avadanii3-0/+12
mcpcontrol virsh network, as well as MaaS PXE network are installer specific, and not POD specific. Therefore, these should be easily parametrized without the PDF, using only installer inputs (e.g. env vars passed via Jenkins). - add new <all-mcp-ocata-common.opnfv.runtime> reclass class; - parametrize at runtime new reclass class based on global vars; - factor out MaaS deploy address / config using new mechanism; - parametrize at runtime virsh network definitions based on template; - add new "maas.pxe_route" sls for configuring routing on cfg01; - replace env vars with the new sls in "maas" state; NOTE: baremetal parametrization will be handled later. Change-Id: Ifd61143d818fb088b3f4395388ba769bbc49156e Signed-off-by: Alexandru Avadanii <Alexandru.Avadanii@enea.com>