diff options
Diffstat (limited to 'docs/release')
27 files changed, 902 insertions, 0 deletions
diff --git a/docs/release/installation/img/addnodes.png b/docs/release/installation/img/addnodes.png Binary files differnew file mode 100644 index 000000000..b62405692 --- /dev/null +++ b/docs/release/installation/img/addnodes.png diff --git a/docs/release/installation/img/compute.png b/docs/release/installation/img/compute.png Binary files differnew file mode 100644 index 000000000..fc1cf0f22 --- /dev/null +++ b/docs/release/installation/img/compute.png diff --git a/docs/release/installation/img/computelist.png b/docs/release/installation/img/computelist.png Binary files differnew file mode 100644 index 000000000..474196536 --- /dev/null +++ b/docs/release/installation/img/computelist.png diff --git a/docs/release/installation/img/fuelconsole1.png b/docs/release/installation/img/fuelconsole1.png Binary files differnew file mode 100644 index 000000000..61703cab1 --- /dev/null +++ b/docs/release/installation/img/fuelconsole1.png diff --git a/docs/release/installation/img/fuelmenu1.png b/docs/release/installation/img/fuelmenu1.png Binary files differnew file mode 100644 index 000000000..4b5097ff4 --- /dev/null +++ b/docs/release/installation/img/fuelmenu1.png diff --git a/docs/release/installation/img/fuelmenu2.png b/docs/release/installation/img/fuelmenu2.png Binary files differnew file mode 100644 index 000000000..42cd75f62 --- /dev/null +++ b/docs/release/installation/img/fuelmenu2.png diff --git a/docs/release/installation/img/fuelmenu3.png b/docs/release/installation/img/fuelmenu3.png Binary files differnew file mode 100644 index 000000000..174cb5004 --- /dev/null +++ b/docs/release/installation/img/fuelmenu3.png diff --git a/docs/release/installation/img/fuelmenu4.png b/docs/release/installation/img/fuelmenu4.png Binary files differnew file mode 100644 index 000000000..0e218fca7 --- /dev/null +++ b/docs/release/installation/img/fuelmenu4.png diff --git a/docs/release/installation/img/fuelmenu5.png b/docs/release/installation/img/fuelmenu5.png Binary files differnew file mode 100644 index 000000000..b1063d576 --- /dev/null +++ b/docs/release/installation/img/fuelmenu5.png diff --git a/docs/release/installation/img/fuelmenu6.png b/docs/release/installation/img/fuelmenu6.png Binary files differnew file mode 100644 index 000000000..16d641e9f --- /dev/null +++ b/docs/release/installation/img/fuelmenu6.png diff --git a/docs/release/installation/img/grub-1.png b/docs/release/installation/img/grub-1.png Binary files differnew file mode 100644 index 000000000..113178948 --- /dev/null +++ b/docs/release/installation/img/grub-1.png diff --git a/docs/release/installation/img/health.png b/docs/release/installation/img/health.png Binary files differnew file mode 100644 index 000000000..57bd8cf70 --- /dev/null +++ b/docs/release/installation/img/health.png diff --git a/docs/release/installation/img/interfaceconf.png b/docs/release/installation/img/interfaceconf.png Binary files differnew file mode 100644 index 000000000..e00b03f03 --- /dev/null +++ b/docs/release/installation/img/interfaceconf.png diff --git a/docs/release/installation/img/interfaces.png b/docs/release/installation/img/interfaces.png Binary files differnew file mode 100644 index 000000000..291e434f6 --- /dev/null +++ b/docs/release/installation/img/interfaces.png diff --git a/docs/release/installation/img/network.png b/docs/release/installation/img/network.png Binary files differnew file mode 100644 index 000000000..7bef05064 --- /dev/null +++ b/docs/release/installation/img/network.png diff --git a/docs/release/installation/img/neutronl3.png b/docs/release/installation/img/neutronl3.png Binary files differnew file mode 100644 index 000000000..36291ef87 --- /dev/null +++ b/docs/release/installation/img/neutronl3.png diff --git a/docs/release/installation/img/newenv.png b/docs/release/installation/img/newenv.png Binary files differnew file mode 100644 index 000000000..d6bc2827f --- /dev/null +++ b/docs/release/installation/img/newenv.png diff --git a/docs/release/installation/img/nodes.png b/docs/release/installation/img/nodes.png Binary files differnew file mode 100644 index 000000000..771e4813d --- /dev/null +++ b/docs/release/installation/img/nodes.png diff --git a/docs/release/installation/img/offloadingmodes.png b/docs/release/installation/img/offloadingmodes.png Binary files differnew file mode 100644 index 000000000..5b3cb17bc --- /dev/null +++ b/docs/release/installation/img/offloadingmodes.png diff --git a/docs/release/installation/img/other.png b/docs/release/installation/img/other.png Binary files differnew file mode 100644 index 000000000..c088488dc --- /dev/null +++ b/docs/release/installation/img/other.png diff --git a/docs/release/installation/img/plugin_install.png b/docs/release/installation/img/plugin_install.png Binary files differnew file mode 100644 index 000000000..ff50633ed --- /dev/null +++ b/docs/release/installation/img/plugin_install.png diff --git a/docs/release/installation/img/plugins.png b/docs/release/installation/img/plugins.png Binary files differnew file mode 100644 index 000000000..8f7ea596f --- /dev/null +++ b/docs/release/installation/img/plugins.png diff --git a/docs/release/installation/img/verifynet.png b/docs/release/installation/img/verifynet.png Binary files differnew file mode 100644 index 000000000..e675562c0 --- /dev/null +++ b/docs/release/installation/img/verifynet.png diff --git a/docs/release/installation/index.rst b/docs/release/installation/index.rst new file mode 100644 index 000000000..cc45cb3fa --- /dev/null +++ b/docs/release/installation/index.rst @@ -0,0 +1,15 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) Open Platform for NFV Project, Inc. and its contributors + +.. _fuel-release-installation-label: + +**************************************** +Installation instruction for Fuel\@OPNFV +**************************************** + +.. toctree:: + :numbered: + :maxdepth: 2 + + installation.instruction.rst diff --git a/docs/release/installation/installation.instruction.rst b/docs/release/installation/installation.instruction.rst new file mode 100644 index 000000000..bec26ae15 --- /dev/null +++ b/docs/release/installation/installation.instruction.rst @@ -0,0 +1,649 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) Open Platform for NFV Project, Inc. and its contributors + +======== +Abstract +======== + +This document describes how to install the Danube release of +OPNFV when using Fuel as a deployment tool, covering its usage, +limitations, dependencies and required system resources. + +============ +Introduction +============ + +This document provides guidelines on how to install and +configure the Danube release of OPNFV when using Fuel as a +deployment tool, including required software and hardware configurations. + +Although the available installation options give a high degree of +freedom in how the system is set-up, including architecture, services +and features, etc., said permutations may not provide an OPNFV +compliant reference architecture. This instruction provides a +step-by-step guide that results in an OPNFV Danube compliant +deployment. + +The audience of this document is assumed to have good knowledge in +networking and Unix/Linux administration. + +======= +Preface +======= + +Before starting the installation of the Danube release of +OPNFV, using Fuel as a deployment tool, some planning must be +done. + +Retrieving the ISO image +======================== + +First of all, the Fuel deployment ISO image needs to be retrieved, the +Fuel .iso image of the Danube release can be found at `OPNFV Downloads <https://www.opnfv.org/software/download>`_. + +Building the ISO image +====================== + +Alternatively, you may build the Fuel .iso from source by cloning the +opnfv/fuel git repository. To retrieve the repository for the Danube +release use the following command: + +.. code-block:: bash + + $ git clone https://gerrit.opnfv.org/gerrit/fuel + +Check-out the Danube release tag to set the HEAD to the +baseline required to replicate the Danube release: + +.. code-block:: bash + + $ git checkout danube.1.0 + +Go to the fuel directory and build the .iso: + +.. code-block:: bash + + $ cd fuel/build; make all + +For more information on how to build, please see :ref:`Build instruction for Fuel\@OPNFV <fuel-development-overview-build-label>` + +Other preparations +================== + +Next, familiarize yourself with Fuel by reading the following documents: + +- `Fuel Installation Guide <http://docs.openstack.org/developer/fuel-docs/userdocs/fuel-install-guide.html>`_ + +- `Fuel User Guide <http://docs.openstack.org/developer/fuel-docs/userdocs/fuel-user-guide.html>`_ + +- `Fuel Developer Guide <http://docs.openstack.org/developer/fuel-docs/devdocs/develop.html>`_ + +- `Fuel Plugin Developers Guide <http://docs.openstack.org/developer/fuel-docs/plugindocs/fuel-plugin-sdk-guide.html>`_ + +Prior to installation, a number of deployment specific parameters must be collected, those are: + +#. Provider sub-net and gateway information + +#. Provider VLAN information + +#. Provider DNS addresses + +#. Provider NTP addresses + +#. Network overlay you plan to deploy (VLAN, VXLAN, FLAT) + +#. How many nodes and what roles you want to deploy (Controllers, Storage, Computes) + +#. Monitoring options you want to deploy (Ceilometer, Syslog, etc.). + +#. Other options not covered in the document are available in the links above + + +This information will be needed for the configuration procedures +provided in this document. + +===================== +Hardware requirements +===================== + +The following minimum hardware requirements must be met for the +installation of Danube using Fuel: + ++--------------------+------------------------------------------------------+ +| **HW Aspect** | **Requirement** | +| | | ++====================+======================================================+ +| **# of nodes** | Minimum 5 (3 for non redundant deployment): | +| | | +| | - 1 Fuel deployment master (may be virtualized) | +| | | +| | - 3(1) Controllers (1 colocated mongo/ceilometer | +| | role, 2 Ceph-OSD roles) | +| | | +| | - 1 Compute (1 co-located Ceph-OSD role) | +| | | ++--------------------+------------------------------------------------------+ +| **CPU** | Minimum 1 socket x86_AMD64 with Virtualization | +| | support | ++--------------------+------------------------------------------------------+ +| **RAM** | Minimum 16GB/server (Depending on VNF work load) | +| | | ++--------------------+------------------------------------------------------+ +| **Disk** | Minimum 256GB 10kRPM spinning disks | +| | | ++--------------------+------------------------------------------------------+ +| **Networks** | 4 Tagged VLANs (PUBLIC, MGMT, STORAGE, PRIVATE) | +| | | +| | 1 Un-Tagged VLAN for PXE Boot - ADMIN Network | +| | | +| | Note: These can be allocated to a single NIC - | +| | or spread out over multiple NICs as your hardware | +| | supports. | ++--------------------+------------------------------------------------------+ + +=============================== +Help with Hardware Requirements +=============================== + +Calculate hardware requirements: + +For information on compatible hardware types available for use, please see `Fuel OpenStack Hardware Compatibility List <https://www.mirantis.com/software/hardware-compatibility/>`_. + +When choosing the hardware on which you will deploy your OpenStack +environment, you should think about: + +- CPU -- Consider the number of virtual machines that you plan to deploy in your cloud environment and the CPU per virtual machine. + +- Memory -- Depends on the amount of RAM assigned per virtual machine and the controller node. + +- Storage -- Depends on the local drive space per virtual machine, remote volumes that can be attached to a virtual machine, and object storage. + +- Networking -- Depends on the Choose Network Topology, the network bandwidth per virtual machine, and network storage. + +================================================ +Top of the rack (TOR) Configuration requirements +================================================ + +The switching infrastructure provides connectivity for the OPNFV +infrastructure operations, tenant networks (East/West) and provider +connectivity (North/South); it also provides needed connectivity for +the Storage Area Network (SAN). +To avoid traffic congestion, it is strongly suggested that three +physically separated networks are used, that is: 1 physical network +for administration and control, one physical network for tenant private +and public networks, and one physical network for SAN. +The switching connectivity can (but does not need to) be fully redundant, +in such case it comprises a redundant 10GE switch pair for each of the +three physically separated networks. + +The physical TOR switches are **not** automatically configured from +the Fuel OPNFV reference platform. All the networks involved in the OPNFV +infrastructure as well as the provider networks and the private tenant +VLANs needs to be manually configured. + +Manual configuration of the Danube hardware platform should +be carried out according to the `OPNFV Pharos Specification +<https://wiki.opnfv.org/display/pharos/Pharos+Specification>`_. + +========================================== +OPNFV Software installation and deployment +========================================== + +This section describes the installation of the OPNFV installation +server (Fuel master) as well as the deployment of the full OPNFV +reference platform stack across a server cluster. + +Install Fuel master +=================== + +#. Mount the Danube Fuel ISO file/media as a boot device to the jump host server. + +#. Reboot the jump host to establish the Fuel server. + + - The system now boots from the ISO image. + + - Select "Fuel Install (Static IP)" (See figure below) + + - Press [Enter]. + + .. figure:: img/grub-1.png + +#. Wait until the Fuel setup screen is shown (Note: This can take up to 30 minutes). + +#. In the "Fuel User" section - Confirm/change the default password (See figure below) + + - Enter "admin" in the Fuel password input + + - Enter "admin" in the Confirm password input + + - Select "Check" and press [Enter] + + .. figure:: img/fuelmenu1.png + +#. In the "Network Setup" section - Configure DHCP/Static IP information for your FUEL node - For example, ETH0 is 10.20.0.2/24 for FUEL booting and ETH1 is DHCP in your corporate/lab network (see figure below). + + - Configure eth1 or other network interfaces here as well (if you have them present on your FUEL server). + + .. figure:: img/fuelmenu2.png + +#. In the "PXE Setup" section (see figure below) - Change the following fields to appropriate values (example below): + + - DHCP Pool Start 10.20.0.4 + + - DHCP Pool End 10.20.0.254 + + - DHCP Pool Gateway 10.20.0.2 (IP address of Fuel node) + + .. figure:: img/fuelmenu3.png + +#. In the "DNS & Hostname" section (see figure below) - Change the following fields to appropriate values: + + - Hostname + + - Domain + + - Search Domain + + - External DNS + + - Hostname to test DNS + + - Select <Check> and press [Enter] + + .. figure:: img/fuelmenu4.png + + +#. OPTION TO ENABLE PROXY SUPPORT - In the "Bootstrap Image" section (see figure below), edit the following fields to define a proxy. (**NOTE:** cannot be used in tandem with local repository support) + + - Navigate to "HTTP proxy" and enter your http proxy address + + - Select <Check> and press [Enter] + + .. figure:: img/fuelmenu5.png + +#. In the "Time Sync" section (see figure below) - Change the following fields to appropriate values: + + - NTP Server 1 <Customer NTP server 1> + + - NTP Server 2 <Customer NTP server 2> + + - NTP Server 3 <Customer NTP server 3> + + .. figure:: img/fuelmenu6.png + +#. Start the installation. + + - Select Quit Setup and press Save and Quit. + + - The installation will now start, wait until the login screen is shown. + +Boot the Node Servers +===================== + +After the Fuel Master node has rebooted from the above steps and is at +the login prompt, you should boot the Node Servers (Your +Compute/Control/Storage blades, nested or real) with a PXE booting +scheme so that the FUEL Master can pick them up for control. + +#. Enable PXE booting + + - For every controller and compute server: enable PXE Booting as the first boot device in the BIOS boot order menu, and hard disk as the second boot device in the same menu. + +#. Reboot all the control and compute blades. + +#. Wait for the availability of nodes showing up in the Fuel GUI. + + - Connect to the FUEL UI via the URL provided in the Console (default: https://10.20.0.2:8443) + + - Wait until all nodes are displayed in top right corner of the Fuel GUI: Total nodes and Unallocated nodes (see figure below). + + .. figure:: img/nodes.png + +Install additional Plugins/Features on the FUEL node +==================================================== + +#. SSH to your FUEL node (e.g. root@10.20.0.2 pwd: r00tme) + +#. Select wanted plugins/features from the /opt/opnfv/ directory. + +#. Install the wanted plugin with the command + + .. code-block:: bash + + $ fuel plugins --install /opt/opnfv/<plugin-name>-<version>.<arch>.rpm + + Expected output (see figure below): + + .. code-block:: bash + + Plugin ....... was successfully installed. + + .. figure:: img/plugin_install.png + +Create an OpenStack Environment +=============================== + +#. Connect to Fuel WEB UI with a browser (default: https://10.20.0.2:8443) (login: admin/admin) + +#. Create and name a new OpenStack environment, to be installed. + + .. figure:: img/newenv.png + +#. Select "<Mitaka on Ubuntu 14.04>" and press <Next> + +#. Select "compute virtulization method". + + - Select "QEMU-KVM as hypervisor" and press <Next> + +#. Select "network mode". + + - Select "Neutron with ML2 plugin" + + - Select "Neutron with tunneling segmentation" (Required when using the ODL or ONOS plugins) + + - Press <Next> + +#. Select "Storage Back-ends". + + - Select "Ceph for block storage" and press <Next> + +#. Select "additional services" you wish to install. + + - Check option "Install Ceilometer and Aodh" and press <Next> + +#. Create the new environment. + + - Click <Create> Button + +Configure the network environment +================================= + +#. Open the environment you previously created. + +#. Open the networks tab and select the "default" Node Networks group to on the left pane (see figure below). + + .. figure:: img/network.png + +#. Update the Public network configuration and change the following fields to appropriate values: + + - CIDR to <CIDR for Public IP Addresses> + + - IP Range Start to <Public IP Address start> + + - IP Range End to <Public IP Address end> + + - Gateway to <Gateway for Public IP Addresses> + + - Check <VLAN tagging>. + + - Set appropriate VLAN id. + +#. Update the Storage Network Configuration + + - Set CIDR to appropriate value (default 192.168.1.0/24) + + - Set IP Range Start to appropriate value (default 192.168.1.1) + + - Set IP Range End to appropriate value (default 192.168.1.254) + + - Set vlan to appropriate value (default 102) + +#. Update the Management network configuration. + + - Set CIDR to appropriate value (default 192.168.0.0/24) + + - Set IP Range Start to appropriate value (default 192.168.0.1) + + - Set IP Range End to appropriate value (default 192.168.0.254) + + - Check <VLAN tagging>. + + - Set appropriate VLAN id. (default 101) + +#. Update the Private Network Information + + - Set CIDR to appropriate value (default 192.168.2.0/24 + + - Set IP Range Start to appropriate value (default 192.168.2.1) + + - Set IP Range End to appropriate value (default 192.168.2.254) + + - Check <VLAN tagging>. + + - Set appropriate VLAN tag (default 103) + +#. Select the "Neutron L3" Node Networks group on the left pane. + + .. figure:: img/neutronl3.png + +#. Update the Floating Network configuration. + + - Set the Floating IP range start (default 172.16.0.130) + + - Set the Floating IP range end (default 172.16.0.254) + + - Set the Floating network name (default admin_floating_net) + +#. Update the Internal Network configuration. + + - Set Internal network CIDR to an appropriate value (default 192.168.111.0/24) + + - Set Internal network gateway to an appropriate value + + - Set the Internal network name (default admin_internal_net) + +#. Update the Guest OS DNS servers. + + - Set Guest OS DNS Server values appropriately + +#. Save Settings. + +#. Select the "Other" Node Networks group on the left pane (see figure below). + + .. figure:: img/other.png + +#. Update the Public network assignment. + + - Check the box for "Assign public network to all nodes" (Required by OpenDaylight) + +#. Update Host OS DNS Servers. + + - Provide the DNS server settings + +#. Update Host OS NTP Servers. + + - Provide the NTP server settings + +Select Hypervisor type +====================== + +#. In the FUEL UI of your Environment, click the "Settings" Tab + +#. Select "Compute" on the left side pane (see figure below) + + - Check the KVM box and press "Save settings" + + .. figure:: img/compute.png + +Enable Plugins +============== + +#. In the FUEL UI of your Environment, click the "Settings" Tab + +#. Select Other on the left side pane (see figure below) + + - Enable and configure the plugins of your choice + + .. figure:: img/plugins.png + +Allocate nodes to environment and assign functional roles +========================================================= + +#. Click on the "Nodes" Tab in the FUEL WEB UI (see figure below). + + .. figure:: img/addnodes.png + +#. Assign roles (see figure below). + + - Click on the <+Add Nodes> button + + - Check <Controller>, <Telemetry - MongoDB> and optionally an SDN Controller role (OpenDaylight controller/ONOS) in the "Assign Roles" Section. + + - Check one node which you want to act as a Controller from the bottom half of the screen + + - Click <Apply Changes>. + + - Click on the <+Add Nodes> button + + - Check the <Controller> and <Storage - Ceph OSD> roles. + + - Check the two next nodes you want to act as Controllers from the bottom half of the screen + + - Click <Apply Changes> + + - Click on <+Add Nodes> button + + - Check the <Compute> and <Storage - Ceph OSD> roles. + + - Check the Nodes you want to act as Computes from the bottom half of the screen + + - Click <Apply Changes>. + + .. figure:: img/computelist.png + +#. Configure interfaces (see figure below). + + - Check Select <All> to select all allocated nodes + + - Click <Configure Interfaces> + + - Assign interfaces (bonded) for mgmt-, admin-, private-, public- and storage networks + + - Click <Apply> + + .. figure:: img/interfaceconf.png + + +Target specific configuration +============================= + +#. Set up targets for provisioning with non-default "Offloading Modes" + + Some target nodes may require additional configuration after they are + PXE booted (bootstrapped); the most frequent changes are in defaults + for ethernet devices' "Offloading Modes" settings (e.g. some targets' + ethernet drivers may strip VLAN traffic by default). + + If your target ethernet drivers have wrong "Offloading Modes" defaults, + in "Configure interfaces" page (described above), expand affected + interface's "Offloading Modes" and [un]check the relevant settings + (see figure below): + + .. figure:: img/offloadingmodes.png + +#. Set up targets for "Verify Networks" with non-default "Offloading Modes" + + **NOTE**: Check *Reference 15* for an updated and comprehensive list of + known issues and/or limitations, including "Offloading Modes" not being + applied during "Verify Networks" step. + + Setting custom "Offloading Modes" in Fuel GUI will only apply those settings + during provisiong and **not** during "Verify Networks", so if your targets + need this change, you have to apply "Offloading Modes" settings by hand + to bootstrapped nodes. + + **E.g.**: Our driver has "rx-vlan-filter" default "on" (expected "off") on + the Openstack interface(s) "eth1", preventing VLAN traffic from passing + during "Verify Networks". + + - From Fuel master console identify target nodes admin IPs (see figure below): + + .. code-block:: bash + + $ fuel nodes + + .. figure:: img/fuelconsole1.png + + - SSH into each of the target nodes and disable "rx-vlan-filter" on the + affected physical interface(s) allocated for OpenStack traffic (eth1): + + .. code-block:: bash + + $ ssh root@10.20.0.6 ethtool -K eth1 rx-vlan-filter off + + - Repeat the step above for all affected nodes/interfaces in the POD. + +Verify Networks +=============== + +It is important that the Verify Networks action is performed as it will verify +that communicate works for the networks you have setup, as well as check that +packages needed for a successful deployment can be fetched. + +#. From the FUEL UI in your Environment, Select the Networks Tab and select "Connectivity check" on the left pane (see figure below) + + - Select <Verify Networks> + + - Continue to fix your topology (physical switch, etc) until the "Verification Succeeded" and "Your network is configured correctly" message is shown + + .. figure:: img/verifynet.png + +Deploy Your Environment +======================= + +#. Deploy the environment. + + - In the Fuel GUI, click on the "Dashboard" Tab. + + - Click on <Deploy Changes> in the "Ready to Deploy?" section + + - Examine any information notice that pops up and click <Deploy> + + Wait for your deployment to complete, you can view the "Dashboard" + Tab to see the progress and status of your deployment. + +========================= +Installation health-check +========================= + +#. Perform system health-check (see figure below) + + - Click the "Health Check" tab inside your Environment in the FUEL Web UI + + - Check <Select All> and Click <Run Tests> + + - Allow tests to run and investigate results where appropriate + + .. figure:: img/health.png + + +============= +Release Notes +============= + +Please refer to the :ref:`Release Notes <fuel-release-notes-label>` article. + +========== +References +========== + +OpenStack + +3) `OpenStack Newton Release Artifacts <http://www.openstack.org/software/newton>`_ +4) `OpenStack Documentation <http://docs.openstack.org>`_ + +OpenDaylight + +5) `OpenDaylight Artifacts <http://www.opendaylight.org/software/downloads>`_ + +Fuel + +6) `The Fuel OpenStack Project <https://wiki.openstack.org/wiki/Fuel>`_ +7) `Fuel Documentation Overview <http://docs.openstack.org/developer/fuel-docs>`_ +8) `Fuel Installation Guide <http://docs.openstack.org/developer/fuel-docs/userdocs/fuel-install-guide.html>`_ +9) `Fuel User Guide <http://docs.openstack.org/developer/fuel-docs/userdocs/fuel-user-guide.html>`_ +10) `Fuel Developer Guide <http://docs.openstack.org/developer/fuel-docs/devdocs/develop.html>`_ +11) `Fuel Plugin Developers Guide <http://docs.openstack.org/developer/fuel-docs/plugindocs/fuel-plugin-sdk-guide.html>`_ +12) `Fuel OpenStack Hardware Compatibility List <https://www.mirantis.com/software/hardware-compatibility/>`_ + diff --git a/docs/release/release-notes/index.rst b/docs/release/release-notes/index.rst new file mode 100644 index 000000000..9cdc01ef0 --- /dev/null +++ b/docs/release/release-notes/index.rst @@ -0,0 +1,15 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) Open Platform for NFV Project, Inc. and its contributors + +.. _fuel-release-notes-label: + +***************************** +Release notes for Fuel\@OPNFV +***************************** + +.. toctree:: + :numbered: + :maxdepth: 2 + + release-notes.rst diff --git a/docs/release/release-notes/release-notes.rst b/docs/release/release-notes/release-notes.rst new file mode 100644 index 000000000..465d0881a --- /dev/null +++ b/docs/release/release-notes/release-notes.rst @@ -0,0 +1,223 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) Open Platform for NFV Project, Inc. and its contributors + +======== +Abstract +======== + +This document compiles the release notes for the Danube release of +OPNFV when using Fuel as a deployment tool. + +=============== +Important Notes +=============== + +These notes provides release information for the use of Fuel as deployment +tool for the Danube release of OPNFV. + +The goal of the Danube release and this Fuel-based deployment process is +to establish a lab ready platform accelerating further development +of the OPNFV infrastructure. + +Carefully follow the installation-instructions provided in *Reference 13*. + +======= +Summary +======= + +For Danube, the typical use of Fuel as an OpenStack installer is +supplemented with OPNFV unique components such as: + +- `OpenDaylight <http://www.opendaylight.org/software>`_ +- `Service Function Chaining <https://wiki.opnfv.org/service_function_chaining>`_ +- `SDN distributed routing and VPN <https://wiki.opnfv.org/sdnvpn>`_ +- `NFV Hypervisors-KVM <https://wiki.opnfv.org/nfv-kvm>`_ +- `Open vSwitch for NFV <https://wiki.opnfv.org/ovsnfv>`_ +- `VSPERF <https://wiki.opnfv.org/characterize_vswitch_performance_for_telco_nfv_use_cases>`_ +- `Promise <https://wiki.opnfv.org/display/promise>`_ +- `Parser <https://wiki.opnfv.org/display/parser>`_ +- `Doctor <https://wiki.opnfv.org/display/doctor>`_ + +As well as OPNFV-unique configurations of the Hardware and Software stack. + +This Danube artifact provides Fuel as the deployment stage tool in the +OPNFV CI pipeline including: + +- Documentation built by Jenkins + + - overall OPNFV documentation + + - this document (release notes) + + - installation instructions + + - build-instructions + +- The Danube Fuel installer image (.iso) built by Jenkins + +- Automated deployment of Danube with running on bare metal or a nested hypervisor environment (KVM) + +- Automated validation of the Danube deployment + +============ +Release Data +============ + ++--------------------------------------+--------------------------------------+ +| **Project** | fuel | +| | | ++--------------------------------------+--------------------------------------+ +| **Repo/tag** | danube.1.0 | +| | | ++--------------------------------------+--------------------------------------+ +| **Release designation** | Danube 1.0 | +| | | ++--------------------------------------+--------------------------------------+ +| **Release date** | March 27 2017 | +| | | ++--------------------------------------+--------------------------------------+ +| **Purpose of the delivery** | Danube alignment to Released | +| | Fuel 10.0 baseline + features and | +| | bug-fixes for the following | +| | feaures: | +| | - NFV Hypervisors-KVM | +| | - Open vSwitch for NFV | +| | - OpenDaylight | +| | - SDN distributed routing and VPN | +| | - Service function chaining | +| | - Promise | +| | - Parser | +| | - Doctor | +| | - Tacker | ++--------------------------------------+--------------------------------------+ + +Version Change +============== + +Module Version Changes +---------------------- +This is the Danube 1.0 release. +It is based on following upstream versions: + +- Fuel 10.0 Base Release + +- OpenStack Newton Release + +- OpenDaylight + +Document Changes +---------------- +This is the Danube 1.0 release. +It comes with the following documentation: + +- Installation instructions + +- Build instructions + +- Release notes (This document) + +Reason for Version +================== + +Feature Additions +----------------- + +**JIRA TICKETS:** + + +Bug Corrections +--------------- + +**JIRA TICKETS:** + +`Danube 1.0 bug fixes <https://jira.opnfv.org/issues/?filter=11406>`_ + +(Also See respective Integrated feature project's bug tracking) + +Deliverables +============ + +Software Deliverables +--------------------- + +Fuel-based installer iso file found in `OPNFV Downloads <https://www.opnfv.org/software/download>`. + +Documentation Deliverables +-------------------------- + +- Installation instructions + +- Build instructions + +- Release notes(This document) + +========================================= +Known Limitations, Issues and Workarounds +========================================= + +System Limitations +================== + +- **Max number of blades:** 1 Fuel master, 3 Controllers, 20 Compute blades + +- **Min number of blades:** 1 Fuel master, 1 Controller, 1 Compute blade + +- **Storage:** Ceph is the only supported storage configuration + +- **Max number of networks:** 65k + + +Known Issues +============ + +**JIRA TICKETS:** + +`Known issues <https://jira.opnfv.org/issues/?filter=11407>`_ + +(Also See respective Integrated feature project's bug tracking) + +Workarounds +=========== + +**JIRA TICKETS:** + +`Workarounds <https://jira.opnfv.org/issues/?filter=11408>`_ + +(Also See respective Integrated feature project's bug tracking) + +============ +Test Results +============ +The Danube 1.0 release with the Fuel deployment tool has undergone QA test +runs, see separate test results. + +========== +References +========== +For more information on the OPNFV Danube 1.0 release, please see: + +OPNFV +===== + +1) `OPNFV Home Page <http://www.opnfv.org>`_ +2) `OPNFV Documentation - and Software Downloads <https://www.opnfv.org/software/download>`_ + +OpenStack +========= + +3) `OpenStack Newton Release Artifacts <http://www.openstack.org/software/newton>`_ + +4) `OpenStack Documentation <http://docs.openstack.org>`_ + +OpenDaylight +============ + +5) `OpenDaylight Artifacts <http://www.opendaylight.org/software/downloads>`_ + +Fuel +==== + +6) `The Fuel OpenStack Project <https://wiki.openstack.org/wiki/Fuel>`_ +7) `Fuel Documentation <http://docs.openstack.org/developer/fuel-docs>`_ + |